X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21894

Well Details

Well ID: 34-055-21894
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Newbury Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: SILVER
License Status: Producing
License Date: 2006-07-27
Spud Date: 2006-11-07
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-11-16
Well Total Depth: 4081 ft
Configuration: Vertical
Latitude: 41.464370647
Longitude: -81.21234272

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-07-27 Proposed Formations:CLINTON, Issued Date:7/27/2006, Expired Date:7/27/2007 6:00:00 AM, Drilling unit acres:32.36, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-11-16 RBDMS Rec
Reached Total Depth 2006-11-16 RBDMS Rec
Completion Report Received 2007-01-16 RBDMS Rec
Construction Permit Expires 2007-07-27 RBDMS Rec
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-28 3837 3890 30

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 19990 Gal 100000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 2286 0 33
2007 JOHN D OIL & GAS COMPANY 25730 63 365
2008 JOHN D OIL & GAS COMPANY 29737 87 365
2009 JOHN D OIL & GAS COMPANY 43630 80 365
2010 JOHN D OIL & GAS COMPANY 31223 0 365
2011 JOHN D OIL & GAS COMPANY 24426 63 365
2012 JOHN D OIL & GAS COMPANY 21849 30 366
2013 JOHN D OIL & GAS COMPANY 21186 33 365
2014 JOHN D OIL & GAS COMPANY 21347 28 365
2015 JOHN D OIL & GAS COMPANY 20492 21 365
2016 DAVID OIL COMPANY LLC 3613 0 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 240 33
2007 JOHN D OIL & GAS COMPANY Brine 40 365
2008 JOHN D OIL & GAS COMPANY Brine 80 365
2009 JOHN D OIL & GAS COMPANY Brine 160 365
2010 JOHN D OIL & GAS COMPANY Brine 160 365
2011 JOHN D OIL & GAS COMPANY Brine 160 365
2012 JOHN D OIL & GAS COMPANY Brine 80 366
2013 JOHN D OIL & GAS COMPANY Brine 0 365
2014 JOHN D OIL & GAS COMPANY Brine 50 365
2015 JOHN D OIL & GAS COMPANY Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0388759232 2015-04-29 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
0915010014 2006-11-08 Drill / Deepen / Reopen No Violations Safety fence needs installed around pits. Silt fence needs installed correctly. Permit needs to be posted on site before site is cut.
0944172556 2016-02-25 UrbanProduction Wells No Violations My inspection found the well equipped with a plunger lift unit. The wooden fence around the wellhead needs repaired. The tank battery is surrounded by a wooden fence. The dike is in good repair. The tank battery consists of a low profile 100 BBL production tank and a 100 BBL brine tank. The tank are vented through a charcoal filter and into a spark arrestor. The load lines are locked and has pluges in them. The heated separator is 50 ft away from the tank battery and is surrounded by a wooden fence. The locks on both of the man doors to the tank battery and separator need replaced. The proper identification is located on the tank battery. The lease road is in stable condition. I have contacted the company about installing locks and repairing the fence.
0967666414 2013-10-21 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well and tank battery are in good repair and are surrounded by a wooden fence. The tank battery consists of a 100 BBL production tank and a 100 BBL brine tank. The tanks are vented through a charcoal filter and into spark arrestors. The heat treated separator has the proper spacing and is surrounded by a wooden fence. The proper identification is located on the tank battery. The lease road is in stable condition.
1163685523 2006-11-15 Drill / Deepen / Reopen Violations Noted Operator has reached TD. Pulling drill pipe at the time of inspection. Pit water level OK. Operator has failed to maintain silt fence around the site. Heavy rains in the forecast for the night. Operator has failed to maintain safety fence around the pits. Mike from John D Oil was called and informed of the Violations Silt fence needs repaired and installed immediately. Silt fence needs to be repaired and installed correctly and maintained until site is reclaimed. Safety fence needs to be installed and repaired, and is to remain until pits are closed.
1163774828 2006-11-17 Drill / Deepen / Reopen No Violations Dirt on the roads, rig had moved off. Safety fence still not up. Called company, asked them to get equipment on site to start cleaning roads. Informed them that drainage controls need repaired and safety fence needs put up. Company stated that they will be solidifying pits ASAP.
1165259752 2006-12-04 Drill / Deepen / Reopen No Violations Rig is off site. Pits are closed. No safety fence needed at this time. Silt fence has been repaired and is in good condition. Site has 4 inches of snow at this time.
1280914388 2006-11-16 Drill / Deepen / Reopen No Violations Silt fence not up. Safety fence not up. Operator was running 4.5 inch production pipe. Spoke to Robert Randall on site regarding silt fence and safety fence. Urban permit requirements are agreed with at the time of the presite inspection, options to the site plan need to be addressed at that time. Once the permit are set, requirements need to be followed. This site is adjacent to a State Park and a large body of water. Continued failure to follow permit condition on drill sites will result in future permits being suspended.
1288378701 2010-10-29 Production Wells No Violations Received a phone call from Mr. Silver regarding John D. Oil & Gas company being habitually late with royalty payments. Mr. Silver expressed frustration with having to contact John D. Oil and at times involve his attorney to receive royalty payments. I informed Mr. Silver that royalties are a civil matter, I would complete an inspection on the location checking for ORC 1509 compliance. Mr. Silver also voiced frustration that he had a difficult time having the company repair his driveway. Site at this time is not in compliance with HB-278. Charcoal filters and spark arrestors need installed. Board on board fencing is starting to fall apart. Hasps and locks are out of line and man doors can not be locked. Contacted company requested fencing be repaired as needed. Locks be replaced and the site needs to come into compliance with HB-278. Lease road is stable. Spacing is correct. Identification sign is posted and is correct. Wellhead is in good repair. Tank battery and dike are in good repair.
1314820010 2011-08-19 Production Wells No Violations Hatches on the tanks closed and sealed. Charcoal filter in place. Load lines locked. Identification sign posted. Man doors locked. Lease road is stable. Well is in good repair.
1464116792 2011-06-29 Production Wells No Violations Locks have been installed on man doors to the tank battery and well head. Lock has been installed on load line. Charcoal filter has been installed on low profile production tank. Dike is in good repair. Wellhead is in good repair. Lease road is stable, rock to location. Identification sign is posted at the tank battery. Hatches on the production tanks were closed and latched.
1826289251 2007-06-21 Preliminary Restoration No Violations Silt fence is up and in poor condition. Site needs seeded and mulched as soon as possible. Spoke with Mike Densmore on 06/22/07, site will be reclaimed in the next two weeks. Tank battery has been installed.
1998370350 2010-11-30 UrbanProduction Wells Violations Noted On site at the request of the landowner. Hatches on top of the tank battery are open. There is an odor of gas and oil in the area. Contacted company requested hatches to be closed and secured. Hatches were closed at the time of inspection. Latch on the man door to the wellhead has not been repaired, door is not able to be locked. Man door latch needs moved or the door needs leveled so that is can be locked. Sent Tim Reilly and e-mail regarding Notice.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1163685523 US-OH-104355 2006-11-16 Failure to comply with permit conditions
1998370350 US-OH-120285 2010-12-13 LOCKS

For data sources see[9]

References