34-081-20443

Well Details

Well ID: 34-081-20443
Loading map...
Country: United States
State: Ohio
County: Jefferson
Municipality: Salem Township
Operator Name: SAMURAI OPERATING COMPANY
Well Pad ID:
Farm/Lease Name: RED OAKS COUNTRY CLUB
License Status: Producing
License Date: 1982-10-22
Spud Date: 1983-01-11
Spud Drilling Contractor: GLEN DRLG
Final Drill Date: 1983-01-19
Well Total Depth: 4919 ft
Configuration: Vertical
Latitude: 40.384085357
Longitude: -80.85361817

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-10-22 597 AMTEX OIL & GAS INC GeoDate 10/22/82
Oil and Gas 1982-10-22 Issued Date 10/22/82 Expired Date 4/20/83 Acres 0122000 Tool Type RTF Proposed Formation ORISKANY Proposed Depth 04919 Proposed Drill Depth 04919
Original Spud 1983-01-11
Completed 1983-01-19
Reached Total Depth 1983-01-19
Completion Report Received 1983-03-10
Construction Permit Expires 1983-04-20
Change of Owner 2001-06-26 Operator changed from 597, AMTEX OIL & GAS INC to 5785, M-J OIL COMPANY INC.
Change of Owner 2008-11-21 Operator changed from 5785, M-J OIL COMPANY INC. to 8453, SAMURAI OPERATING COMPANY
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4800 4810 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 32000 Gal 11500 FRAC;32MG H2O,12M# SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 AMTEX OIL & GAS INC 1471 1355 365
1986 AMTEX OIL & GAS INC 2238 918 0
1987 AMTEX OIL & GAS INC 2059 1022 0
1988 AMTEX OIL & GAS INC 1345 937 0
1989 AMTEX OIL & GAS INC 710 321 0
1990 AMTEX OIL & GAS INC 1100 1461 365
1993 AMTEX OIL & GAS INC 693 372 245
2001 M-J OIL COMPANY INC. 1293 695 179
2002 M-J OIL COMPANY INC. 1223 986 365
2003 M-J OIL COMPANY INC. 1037 605 365
2004 M-J OIL COMPANY INC. 1153 891 156
2005 M-J OIL COMPANY INC. 1304 755 365
2006 M-J OIL COMPANY INC. 802 825 365
2007 M-J OIL COMPANY INC. 487 572 365
2008 M-J OIL COMPANY INC. 227 468 140
2009 SAMURAI OPERATING COMPANY 143 773 345
2010 SAMURAI OPERATING COMPANY 932 412 365
2011 SAMURAI OPERATING COMPANY 582 576 365
2012 SAMURAI OPERATING COMPANY 679 584 366
2013 SAMURAI OPERATING COMPANY 814 794 365
2014 SAMURAI OPERATING COMPANY 1002 555 365
2015 SAMURAI OPERATING COMPANY 946 930 333
2016 SAMURAI OPERATING COMPANY 577 762 333
2017 SAMURAI OPERATING COMPANY 602 862 358
2018 SAMURAI OPERATING COMPANY 365 810 21

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 AMTEX OIL & GAS INC Brine 5903 365
1986 AMTEX OIL & GAS INC Brine 2215 0
1987 AMTEX OIL & GAS INC Brine 2320 0
1988 AMTEX OIL & GAS INC Brine 2945 0
1989 AMTEX OIL & GAS INC Brine 2145 0
1990 AMTEX OIL & GAS INC Brine 2845 365
1993 AMTEX OIL & GAS INC Brine 2471 245
2001 M-J OIL COMPANY INC. Brine 1320 179
2002 M-J OIL COMPANY INC. Brine 1285 365
2003 M-J OIL COMPANY INC. Brine 1325 365
2004 M-J OIL COMPANY INC. Brine 2955 156
2005 M-J OIL COMPANY INC. Brine 1903 365
2006 M-J OIL COMPANY INC. Brine 1945 365
2007 M-J OIL COMPANY INC. Brine 1709 365
2008 M-J OIL COMPANY INC. Brine 1445 140
2009 SAMURAI OPERATING COMPANY Brine 1268 345
2010 SAMURAI OPERATING COMPANY Brine 1320 365
2011 SAMURAI OPERATING COMPANY Brine 1675 365
2012 SAMURAI OPERATING COMPANY Brine 2351 366
2013 SAMURAI OPERATING COMPANY Brine 1811 365
2014 SAMURAI OPERATING COMPANY Brine 728 365
2015 SAMURAI OPERATING COMPANY Brine 1260 333
2016 SAMURAI OPERATING COMPANY Brine 1650 333
2017 SAMURAI OPERATING COMPANY Brine 1525 358
2018 SAMURAI OPERATING COMPANY Brine 1494 21

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL14874 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0621029798 2002-10-31 Production Wells No Violations Routine inspection revealed no violations at this time .
0660123157 2014-08-14 Production Wells No Violations Onsite with inspector Andrew Corder. Well appears to have all necessary equipment for production including pumping unit. Tank battery contains a mechanical seperator and 2-210 bbl tanks. No violations were noted this date.
1102086625 2017-06-05 Production Wells No Violations On the date of my inspection I found the production equipment to include 2 properly identified 100 barrel tanks, a concrete brine vault, horizontal separator, a production meter box with a current chart tied into the production line by a union containing an orifice plate, 3 drips, and a domestic diaphragm meter, within an earthen dike. The wellhead is equipped with a pumping unit, rods, 2.375 inch tubing, and 4.5 inch casing. The tubing and casing valves are in the open position. A pressure gauge tied into the production line from the tubing reads 40 pounds per square inch. Production records are current.
1470926232 2016-08-11 Production Wells No Violations On the date of my inspection I found the tank battery to include 2 properly identified 100 barrel tanks, a concrete brine vault, horizontal separator, and a production meter box with a current chart, 2 drips, and a domestic diaphragm meter, within an earthen dike. Ponded water around the base of the separator with high chloride levels (Quantab >1,500 ppm). An area approximately 3 feet wide by 15 feet long has brine staining leading to the ponded water. Slow leak from the bottom valve of the tank. The well is equipped with a pumping unit, rods, 2.375 inch tubing, and 4.5 inch casing. The tubing and casing valves are in the open position. Production records end in 2014. Pictures were taken. I spoke with Jim Posey with Samurai Corp about clean-up. He indicated that he would repair or replace the leaking tank and fix remove the contaminated ground between the tank and separator.
1472478221 2016-08-29 Production Wells No Violations I am on site today to follow up on my findings from a previous inspection on 8/11/16. The operator has removed contamination surrounding the well head and placed new gravel on the area. A noticeable gas leak where the casing is tied into a 0.25 inch metal line can be heard. I notified the operator who indicated he would fix it today. Contamination within the tank berm between the tank and separator has been removed and new gravel has been placed on that area as well. The leaking area has not been repaired but the tank has been drained and is shut off from the system. The operator indicated he would repair it soon. The area immediately surrounding the horizontal separator within the tank berm is still saturated and the equipment is heavily rusted and deteriorated.
1526044749 2018-05-11 Production Wells No Violations On the day of my inspection I found this well equipped with an operating walking beam pumping unit. Well has 4.5 inch diameter casing, 1.9 inch diameter tubing, and rods. Production equipment includes two 100 barrel steel tanks, horizontal seperator, drips, domestic meter and a concrete brine vault. Vault is 18 inches from full. Gravel within containment appears to have brine staining from tank lines. Evidently a valve was recently replaced and a line was patched with a band clamp. Contamination will need cleaned up. Production records are up to date.
1530103871 2018-06-27 Production Wells No Violations On the day of my inspection I witnessed that Jim Posey was onsite with a service rig. They pulled the rods from the well and changed out the pump downhole. They were running the pump and rods back in during my inspection. Rods are laid out over plastic to keep contamination off of the ground. Jim said they will finish up and clean up today.
1604469732 2014-08-14 Production Wells No Violations
1636379325 2002-10-31 Production Wells No Violations Routine inspection revealed no violations at this time .
1836300727 2016-12-07 Production Wells No Violations On the date of my inspection I found the tank battery to include 2 properly identified 100 barrel tanks, a concrete brine vault, horizontal separator, a production meter box with a current chart tied into the production line by a union containing an orifice plate, 2 drips, and a domestic diaphragm meter, within an earthen dike. The wellhead is equipped with a pumping unit, rods, 2.375 inch tubing, and 4.5 inch casing. The tubing and casing valves are in the open position. Production records end in 2014.
1890763926 2017-10-19 Production Wells No Violations On the date of my inspection I found the production equipment to include 2 properly identified 100 barrel tanks, a concrete brine vault, horizontal separator, a production meter box with a current chart tied into the production line by a union containing an orifice plate, 3 drips, and a domestic diaphragm meter, within an earthen dike. The wellhead is equipped with a pumping unit, rods, 2.375 inch tubing, and 4.5 inch casing. The tubing and casing valves are in the open position. A pressure gauge tied into the tubing line reads 25 pounds per square inch. Currently there is a metal chain from the frame on the pumping unit to the wellhead. This chain was placed to prevent the pumping unit from walking away from the wellhead (according to Jim Posey with Samurai). There are a few rods on the ground hear the wellhead and 1 within the production dike. Production records are current.
2040208139 2013-07-16 Production Wells No Violations I was on location to do a status check on this well. The entire tank battery and the production equipment has been repainted and a new sign with updated information has been posted. The well is located near the fairway of the golf course. There are no violations at this time.

For data sources see[9]

References