37-033-26998

Well Details

Well ID: 37-033-26998
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Pine Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 144573
Farm/Lease Name: DCNR TRACT 323 P-2
License Status: Plugged and Abandoned
Spud Date: 2011-07-22
Permit Date: 2011-03-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.090114
Longitude: -78.531649

For data sources see[1][2][3]

Well History

Date Event
2011-03-17 New Permit Application
2011-07-19 Performed Spud Operation
2011-10-09 Drilling Completion
2011-11-03 Perforation
2011-11-03 Performed Stage 1 of Stimulation
2011-11-03 Performed Stage 2 of Stimulation
2011-11-04 Perforation
2011-11-04 Performed Stage 3 of Stimulation
2011-11-04 Performed Stage 4 of Stimulation
2011-11-04 Performed Stage 5 of Stimulation
2011-11-04 Performed Stage 6 of Stimulation
2011-11-05 Perforation
2011-11-05 Performed Stage 10 of Stimulation
2011-11-05 Performed Stage 7 of Stimulation
2011-11-05 Performed Stage 8 of Stimulation
2011-11-05 Performed Stage 9 of Stimulation
2011-11-06 Perforation
2011-11-06 Performed Stage 11 of Stimulation
2011-11-06 Performed Stage 12 of Stimulation
2012-09-28 DEVIATED
2014-11-18 NEWLY DRILLED
2019-02-12 Inactive Well Request Granted
2019-08-26 Begin Plugging
2019-09-04 Finished Plugging
2020-01-13 Fully Plugged

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-11-03 2011-11-03 7,133 4,637,003

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 3 HCl Acid Calfrac Well Services Perforation Breakdown Hydrochloric acid 7647-01-0 100.00 0.73
DAP-923 Calfrac Well Services Corrosion Inhibitor Olefin 5.00 0.00006000
Polyoxyalkylenes 30.00 0.00039000
Thiourea polymer 68527-49-1 30.00 0.00039000
Methanol 67-56-1 60.00 0.00078000
Fatty acids 30.00 0.00039000
Propargyl alcohol 107-19-7 10.00 0.00013000
Water Base Fluid Water 100.00 85.86
DAP-901 Calfrac Well Services Scale Inhibitor Organic phosphonate 30.00 0.00564000
Amine salt 5.00 0.00094000
Oxyalkylated polyamine 5.00 0.00094000
Phosphoric acid ammonium salt 5.00 0.00094000
Methanol 67-56-1 30.00 0.00564000
Ammonium chloride 12125-02-9 10.00 0.00188000
DWP-944 Calfrac Well Services Biocide Polyethylene glycol 25322-68-3 70.00 0.02
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
DAP-103 Calfrac Well Services Iron Control Citric acid 77-92-9 60.00 0.00324000
DWP-612 Calfrac Well Services Friction Reducer No Hazardous Materials 100.00 0.08
Sand (Proppant) Calfrac Well Services Propping Agent Quartz 14808-60-7 99.90 13.23

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-11-03 1 Silica Sand 5,406,880 7,406 0
2011-11-03 2 Silica Sand 5,406,880 7,353 0
2011-11-04 3 Silica Sand 5,406,880 7,440 0
2011-11-04 4 Silica Sand 5,406,880 8,204 0
2011-11-04 5 Silica Sand 5,406,880 7,785 0
2011-11-04 6 Silica Sand 5,406,880 7,436 0
2011-11-05 7 Silica Sand 5,406,880 7,781 0
2011-11-05 8 Silica Sand 5,406,880 7,669 0
2011-11-05 9 Silica Sand 5,406,880 7,521 0
2011-11-05 10 Silica Sand 5,406,880 7,657 0
2011-11-06 11 Silica Sand 5,406,880 7,220 0
2011-11-06 12 Silica Sand 5,406,880 7,545 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA INC Fracing Fluid Waste 12,243.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Drilling Fluid Waste 1,739.05 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2017 EXCO RESOURCES PA LLC Synthetic Liner Materials 55.36 Tons LANDFILL 101397
2019 EXCO RESOURCES PA LLC Drilling Fluid Waste 850.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1970110 Primary Facility 2011-05-03 Compliance Evaluation No Violations Noted
1988415 Primary Facility 2011-07-18 Compliance Evaluation No Violations Noted
1990857 Primary Facility 2011-07-28 Incident- Response to Accident or Event Pending
1991860 Primary Facility 2011-08-01 Compliance Evaluation No Violations Noted
1994348 Primary Facility 2011-08-09 Compliance Evaluation No Violations Noted
2002458 Primary Facility 2011-09-14 Compliance Evaluation No Violations Noted
2006040 Primary Facility 2011-09-28 Compliance Evaluation No Violations Noted
2028179 Primary Facility 2011-12-20 Routine/Complete Inspection No Violations Noted
2042935 Primary Facility 2012-02-15 Routine/Complete Inspection No Violations Noted Cellar was bubbling heavily; OGI Andrew Albert informed 2/15/12
2060287 Primary Facility 2012-04-18 Routine/Complete Inspection No Violations Noted
2070883 Primary Facility 2012-05-22 Routine/Complete Inspection No Violations Noted
2070886 Primary Facility 2012-05-23 Routine/Complete Inspection No Violations Noted
2070888 Primary Facility 2012-05-24 Routine/Complete Inspection No Violations Noted
2119975 Primary Facility 2012-12-03 Routine/Complete Inspection No Violations Noted
2121930 Primary Facility 2012-12-07 Follow-up Inspection No Violations Noted
2178532 Primary Facility 2013-06-27 Routine/Complete Inspection No Violations Noted
2189924 Primary Facility 2013-08-08 Routine/Complete Inspection No Violations Noted
2266429 Primary Facility 2014-04-29 Routine/Complete Inspection No Violations Noted
2338465 Primary Facility 2015-01-26 Routine/Complete Inspection No Violations Noted
2380965 Primary Facility 2015-06-22 Routine/Complete Inspection No Violations Noted
2443455 Primary Facility 2016-01-26 Routine/Complete Inspection No Violations Noted
2492697 Primary Facility 2016-06-14 Routine/Complete Inspection No Violations Noted
2506054 Primary Facility 2016-07-28 Routine/Complete Inspection No Violations Noted
2513680 Primary Facility 2016-08-24 Routine/Complete Inspection No Violations Noted
2562914 Primary Facility 2017-02-16 Routine/Complete Inspection No Violations Noted
2765899 Primary Facility 2018-08-14 Routine/Complete Inspection No Violations Noted Department representatives Sue Herzing, Sara Metz, and Mike Jurbala conducted a routine site inspection at Exco Resources COP Tract 323 Pad 2 on August 14, 2018. The site sign, weekly E&S inspection log, and ESCGP were onsite for review.

The freshwater impoundment (FWI) was restored and PCSMs installed during the Summer of 2017. All disturbed and/or restored areas have been seeded and mulched. We observed regraded soils in the rain garden. The rain garden has been reseeded and mulched. Fencing has been installed surrounding the restored FWI. No trees have been planted in the restored impoundment area to date per the agreement between DCNR and EXCO. A few bare spots with little to no vegetation were observed near the restored FWI fence. The Department recommends spot seeding those sections.

There is one drilled Marcellus well (033-26998) onsite. According the the Departments efacts records this well was granted regulatory inactive status (RIS) on February 8, 2013; therefore this status has expired on Fe

2774184 Primary Facility 2018-09-12 Routine/Complete Inspection No Violations Noted The weather is 70 Deg. F, cloudy at time of inspection. Routine inspection of EXCO Resources PA LLC., DCNR Tract 323 P-2 Pad, Well # 31H on September 12, 2018. There is 1 well on location, currently in regulatory inactive status. Inactive Well Status has been granted on 02/02/2013, expired on 02/08/2018. Well was shut in upon arrival to location. After opening valves, pressure gauge on the top of the production xmas tree reads 3,840 PSI, backside casing pressure gauge reads 1,336 PSI. Annulus (9-5/8¿ x 4-1/2¿) was opened and vented into a tank, pressure gauge reads 0 PSI, another annulus (13-3/8¿ x 9-5/8¿) was open and shut into a pressure gauge, that also reads 0 PSI. 0% combustible gas was detected in the area immediately surrounding the well. No obvious concerns or violations are noted at time of inspection.

EXCO Resources, LLC. Representative ¿ Sam Unch, Production Operator and Brian Rushe, Regulatory Manager. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

2854181 Primary Facility 2019-03-14 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at EXCO Resources PA LLC COP Tract 323 Pad 2 on March 14, 2019.

The freshwater impoundment (FWI) was restored and PCSMs installed during the Summer of 2017. The restored FWI is surrounded by a fence enclosure per the PCSM plans. Trees have been planted within the restored FWI fence enclosure per the agreement with EXCO and DCNR. All previously disturbed and/or restored areas have been seeded and mulched. The overall site is mostly snow covered. The rain garden is nearly full to the top with water and ice/snow covered. The trash rack was covered debris. The Department recommends removing the debris on the track rack as outlined in your long term operation and maintenance plan. Large amounts of water and ice were observed on the well pad. As recommended in previous inspections reports but myself, I recommend regrading the well pad so ponded flows off the well pad into the designed PCSMs.

There is one drilled Marcellus well (033-2699

For data sources see[9]

References