37-083-52148

Well Details

Well ID: 37-083-52148
Loading map...
Country: United States
State: Pennsylvania
County: McKean
Municipality: Hamlin Township
Operator Name: CURTIS OIL INC
Well Pad ID:
Farm/Lease Name: KUSHEQUA LOT 212 Q17
License Status: ACTIVE
Spud Date:
Permit Date: 2007-05-08
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.751732
Longitude: -78.608773

For data sources see[1][2][3]

Well History

Date Event
2007-05-08 New Permit Application
2007-08-08 Performed Spud Operation
2007-08-10 Drilling Completion
2007-11-14 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 QUAIL ENERGY CORP 2,640.22 365 399.33 365 0.00 0
2009 QUAIL ENERGY CORP 899.67 146 164.49 146 0.00 0
2010 QUAIL ENERGY CORP 1,428.11 365 134.78 365 0.00 0
2016 CURTIS OIL INC 645.56 365 57.33 365 0.00 0
2017 CURTIS OIL INC 529.44 365 53.33 365 0.00 0
2018 CURTIS OIL INC 238.40 365 29.93 365 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 QUAIL ENERGY CORP Produced Fluid 313.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010 QUAIL ENERGY CORP Produced Fluid 273.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2016 CURTIS OIL INC Produced Fluid 44.44 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CURTIS OIL INC Produced Fluid 61.11 Bbl REUSE AT A CONVENTIONAL WELL SITE IN PA
2018 CURTIS OIL INC Produced Fluid 40.00 Bbl REUSE AT A CONVENTIONAL WELL SITE IN PA
2019 CURTIS OIL INC Produced Fluid 36.67 Bbl REUSE AT A CONVENTIONAL WELL SITE IN PA

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1644418 Primary Facility 2007-08-09 Complaint Inspection Violation(s) Noted
1653155 Primary Facility 2007-09-17 Routine/Complete Inspection Violation(s) Noted
1653574 Primary Facility 2007-09-25 Follow-up Inspection No Violations Noted
1654041 Primary Facility 2007-09-27 Routine/Complete Inspection No Violations Noted
1660113 Primary Facility 2007-10-23 Follow-up Inspection No Violations Noted
1944954 Primary Facility 2011-01-21 Routine/Complete Inspection No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1644418 521314 08/09/2007 2007-08-09 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1653155 523995 09/17/2007 2007-09-17 78.73B - Excessive casing seat pressure Administrative
1653155 523996 09/17/2007 2007-09-17 78.73B - Excessive casing seat pressure Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
521314
523995 226130 NOV - Notice of Violation Comply/Closed 2007-10-23 $4,937.00 $4,937.00
523996 226130 NOV - Notice of Violation Comply/Closed 2007-10-23 $4,937.00 $4,937.00

For data sources see[7]

References