37-059-26115

Well Details

Well ID: 37-059-26115
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Dunkard Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 144823
Farm/Lease Name: MILLER UNIT 80H
License Status:
Spud Date:
Permit Date: 2013-02-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.785056
Longitude: -80.028839

For data sources see[1][2][3]

Well History

Date Event
2013-02-28 New Permit Application
2013-03-21 Performed Spud Operation
2013-11-05 Drilling Completion
2014-06-01 Perforation
2014-06-01 Performed Stimulation
2016-02-02 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-06-01 2014-06-05 7,954 4,934,540

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 J134 Schlumberger Gel Breaker Hemicellulase Enzyme 9012-54-8 100 0.00097798 0
J580 Schlumberger Gelling Agent Carboydrate polymer Proprietary 100 0.0224429 0
15% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 15 0.0196326 0
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00082754 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 9.35748 0
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00332645 0
EC6116A Nalco Biocide Polyethylene Glycol 25322-68-3 60 0.00155415 0
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00077707 0
Dibromoacetonitrile 3252-43-5 5 0.00012951 0
Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 90.4859 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00035626 0
J609 Schlumberger Friction Reducer Ammonium Sulfate 7783-20-2 30 0.0084834 0
A264 Schlumberger Iron Control Aliphatic acids Proprietary 30 0.00003313 0
Methanol 67-56-1 40 0.00004418 0
Aliphatic alcohols, ethoxylayed #1 Proprietary 30 0.00003313 0
Prop-2-yn-1-ol 107-19-7 10 0.00001104 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-06-01 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 249,421.00 36 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 927,723.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 607,540.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 451,104.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 359,731.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 299,471.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CHEVRON APPALACHIA LLC Drill Cuttings 761.48 Tons LANDFILL 100172
2013 CHEVRON APPALACHIA LLC Drill Cuttings 354.61 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 4,729.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 0.96 Tons LANDFILL 100663
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 27.16 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 10.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,326.72 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Drill Cuttings 2.21 Tons LANDFILL 100172
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 0.23 Tons LANDFILL 073 114 654
2015 CHEVRON APPALACHIA LLC Produced Fluid 157.29 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,063.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 1.47 Tons LANDFILL 100419
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 292.14 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 14.39 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565
2015 CHEVRON APPALACHIA LLC Produced Fluid 9,319.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 1,573.83 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 2,460.95 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 51.42 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 348.55 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 57.14 Bbl INJECTION DISPOSAL WELL 34-059-24202
2017 CHEVRON APPALACHIA LLC Produced Fluid 611.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 172.86 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 CHEVRON APPALACHIA LLC Produced Fluid 949.90 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 187.85 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 31.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 648.55 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 89.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 18.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 654.10 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 68.57 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2160347 Primary Facility 2013-03-21 Routine/Complete Inspection No Violations Noted
2185003 Primary Facility 2013-07-12 Drilling/Alteration No Violations Noted WELL DRILLED TO KOP. WATING FOR HORIZONTAL RIG TO MOVE IN AND COMMENCE DRILLING WELL TO COMPLETION.
2334360 Primary Facility 2014-10-06 Routine/Complete Inspection No Violations Noted Well being placed into production.
2356481 Primary Facility 2015-02-24 Routine/Complete Inspection No Violations Noted
2380289 Primary Facility 2015-06-04 Routine/Complete Inspection No Violations Noted
2487912 Primary Facility 2016-05-25 Drilling/Alteration No Violations Noted
2549796 Primary Facility 2016-12-08 Routine/Complete Inspection No Violations Noted On 12/08/16 at approximately 0930 hours I conducted a routine complete inspection of the Miller Unit. The Act 9 sign was in place and all required documents were present at the site. The pad was fenced and gated. The site was well vegetated and it appeared Chevron had recently seeded and mulched a small area to the north of the access road. There was no erosion observed at the time of inspection. There were no violations observed at the time of inspection.
2623691 Primary Facility 2017-08-07 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. One location along the access road appeared to have been seeded and mulched. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2636981 Primary Facility 2017-09-15 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved.
2663927 Primary Facility 2017-11-16 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2752959 Primary Facility 2018-07-17 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[9]