If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-26170 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.785036,"lon":-80.028792,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Dunkard Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 144823 | |
Farm/Lease Name: MILLER UNIT 79H | |
License Status: Active | |
Spud Date: 2013-03-22 | |
Permit Date: 2013-05-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 39.785036 | |
Longitude: -80.028792 |
Date | Event |
---|---|
2013-05-17 | New Permit Application |
2013-06-03 | Performed Spud Operation |
2013-11-11 | Drilling Completion |
2020-01-22 | Deviated |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-06-16 | 2014-06-19 | 7,909 | 4,354,340 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | J609 | Schlumberger | Friction Reducer | Ammonium Sulfate | 7783-20-2 | 30 | 0.0133039 | 0 |
Proppant | Schlumberger | Proppant | Crystalline Silica | 14808-60-7 | 100 | 8.49564 | 0 | |
EC6116A | Nalco | Biocide | Dibromoacetonitrile | 3252-43-5 | 5 | 0.0001311 | 0 | |
Polyethylene Glycol | 25322-68-3 | 60 | 0.00157322 | 0 | ||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00078661 | 0 | ||||
Base Fluid | Chevron | Carrier/Base Fluid | Water (Including Mix Water Supplied by Client) | 7732-18-5 | 100 | 91.3085 | 0 | |
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.0008302 | 0 | |
L058 | Schlumberger | Iron Stabilizer | Sodium erythorbate | 6381-77-7 | 100 | 0.00038584 | 0 | |
J134 | Schlumberger | Gel Breaker | Hemicellulase Enzyme | 9012-54-8 | 100 | 0.00135044 | 0 | |
J580 | Schlumberger | Gelling Agent | Carboydrate polymer | Proprietary | 100 | 0.0351954 | 0 | |
A264 | Schlumberger | Iron Control | Aliphatic acids | Proprietary | 30 | 0.00003569 | 0 | |
Methanol | 67-56-1 | 40 | 0.00004758 | 0 | ||||
Aliphatic alcohols, ethoxylayed #1 | Proprietary | 30 | 0.00003569 | 0 | ||||
Prop-2-yn-1-ol | 107-19-7 | 10 | 0.00001190 | 0 | ||||
EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00409386 | 0 | |
15% Acid | Schlumberger | Perf Cleanup | Hydrocloric Acid | 7647-01-0 | 15 | 0.0204652 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 321,758.00 | 50 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 791,855.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 529,780.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 408,112.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 330,160.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 293,511.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | CHEVRON APPALACHIA LLC | Drill Cuttings | 761.49 Tons | LANDFILL | 100172 |
2013 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 3,210.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Drill Cuttings | 354.62 Tons | LANDFILL | 100419 |
2014 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 4,729.29 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 0.96 Tons | LANDFILL | 100663 |
2014 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 27.16 Tons | LANDFILL | 100172 |
2014 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 10.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 3,326.72 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Drill Cuttings | 2.21 Tons | LANDFILL | 100172 |
2015 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 0.23 Tons | LANDFILL | 073 114 654 |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 157.29 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2015 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 2,063.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 1.47 Tons | LANDFILL | 100419 |
2015 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 292.14 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 14.39 Tons | RESIDUAL WASTE TRANSFER FACILITY | MID074259565 |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 9,319.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,573.83 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,460.95 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 348.55 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 51.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 57.14 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 611.56 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 172.86 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 994.66 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 204.99 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 31.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 648.55 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 89.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 728.39 Bbl | REUSE (AT WELL PAD) | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 68.57 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 18.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2185002 | Primary Facility | 2013-07-12 | Drilling/Alteration | No Violations Noted | KEANE 2144 DRILLING FOR CHEVRON. WERE DRILLING 10 7/8 HOLE @ 1181'. |
2224672 | Primary Facility | 2013-11-18 | Drilling/Alteration | No Violations Noted | PATTERSON RIG 339 DRILLING FOR CHEVRON. HAD REACHED TD ON VERTICAL SECTION AT 13,780 AND WERE T.O.H. SETTING UP TO RUN CASING TO 13,760. |
2334359 | Primary Facility | 2014-10-06 | Routine/Complete Inspection | No Violations Noted | Well being placed into production. |
2356485 | Primary Facility | 2015-02-24 | Routine/Complete Inspection | No Violations Noted | |
2380288 | Primary Facility | 2015-06-04 | Routine/Complete Inspection | No Violations Noted | |
2487915 | Primary Facility | 2016-05-25 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, Restoration in process. |
2549795 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | |
2623715 | Primary Facility | 2017-08-07 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. One location along the access road appeared to have been seeded and mulched. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2636984 | Primary Facility | 2017-09-15 | Site Restoration | No Violations Noted | A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved. |
2663936 | Primary Facility | 2017-11-16 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2752963 | Primary Facility | 2018-07-17 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
For data sources see[8]