If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-039-25739 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.795889,"lon":-80.336333,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Crawford | |
Municipality: Spring Township | |
Operator Name: ENERVEST OPR LLC | |
Well Pad ID: | |
Farm/Lease Name: MEYER 1 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-06-07 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 41.795889 | |
Longitude: -80.336333 |
Date | Event |
---|---|
2011-06-07 | New Permit Application |
2011-08-16 | Performed Spud Operation |
2011-09-13 | Drilling Completion |
2011-09-22 | Perforation |
2011-12-01 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | ENERVEST OPR LLC | 50,341.00 | 55 | 1025.83 | 55 | 0.00 | 0 |
2012 | ENERVEST OPR LLC | 335,257.00 | 365 | 3498.79 | 365 | 0.00 | 0 |
2013 | ENERVEST OPR LLC | 41,310.00 | 365 | 198.37 | 365 | 0.00 | 0 |
2014 | ENERVEST OPR LLC | 21,597.65 | 365 | 86.30 | 365 | 0.00 | 0 |
2015 | ENERVEST OPR LLC | 13,478.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | ENERVEST OPR LLC | 7,908.00 | 366 | 66.00 | 366 | 0.00 | 0 |
2017 | ENERVEST OPR LLC | 2,704.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | ENERVEST OPR LLC | 2,888.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | ENERVEST OPR LLC | 3,025.00 | 332 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | ENERVEST OPR LLC | Fracing Fluid Waste | 320.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | ENERVEST OPR LLC | Produced Fluid | 40.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | ENERVEST OPR LLC | Produced Fluid | 24.00 Bbl | ROAD SPREADING | |
2012 | ENERVEST OPR LLC | Produced Fluid | 66.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24523 |
2012 | ENERVEST OPR LLC | Produced Fluid | 58.00 Bbl | ROAD SPREADING | |
2013 | ENERVEST OPR LLC | Produced Fluid | 99.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24523 |
2014 | ENERVEST OPR LLC | Produced Fluid | 13.67 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016 | ENERVEST OPR LLC | Produced Fluid | 108.33 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016 | ENERVEST OPR LLC | Produced Fluid | 52.03 Bbl | ROAD SPREADING | |
2017 | ENERVEST OPR LLC | Produced Fluid | 47.50 Bbl | REUSE AT A CONVENTIONAL WELL SITE IN PA | |
2017 | ENERVEST OPR LLC | Produced Fluid | 29.17 Bbl | ROAD SPREADING | |
2017 | ENERVEST OPR LLC | Produced Fluid | 18.33 Bbl | INJECTION DISPOSAL WELL | 34-007-20919 |
2018 | ENERVEST OPR LLC | Produced Fluid | 36.67 Bbl | REUSE AT A CONVENTIONAL WELL SITE IN PA | |
2018 | ENERVEST OPR LLC | Produced Fluid | 35.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24523 |
2019 | ENERVEST OPR LLC | Produced Fluid | 16.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24523 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1998107 | Primary Facility | 2011-08-19 | Routine/Complete Inspection | No Violations Noted | This is a new well pad site. The access road has been pushed in and is in good condition with a stone base. The well pad is pushed in and some stone in place. The site ID, permit, E&S Plan and BMPs are in place as required. A determination is pending regarding the possibilty of a wetlands greater than an acre in size located to the south of the site, within 50 ft from the edge of the pad. |
2000946 | Primary Facility | 2011-09-01 | Drilling/Alteration | No Violations Noted | |
2001404 | Primary Facility | 2011-09-06 | Drilling/Alteration | No Violations Noted | |
2001421 | Primary Facility | 2011-09-08 | Drilling/Alteration | No Violations Noted | |
2002084 | Primary Facility | 2011-09-08 | Follow-up Inspection | No Violations Noted | Rig on-site activily drilling-- E&S controls in plae- site ID and permit in place- BMPS in place- no violations |
2002218 | Primary Facility | 2011-09-12 | Drilling/Alteration | No Violations Noted | |
2003016 | Primary Facility | 2011-09-13 | Drilling/Alteration | No Violations Noted | |
2004629 | Primary Facility | 2011-09-22 | Routine/Complete Inspection | No Violations Noted | On site to determine if E&S controls and pollution prevention measures are functioning as required while rig is operating. Upon inspection i found all BMPs in place and working as designed. |
2011919 | Primary Facility | 2011-10-17 | Routine/Complete Inspection | No Violations Noted | Upon inspection I found a producing well with the annulus open. Production equipment consist of 210 bbl steel tank and a separator/dryer; this well was just comepleted last month; the well pad has been rough graded- and is curently very wet due to heavy rain. BMPS still in place. |
2027839 | Primary Facility | 2011-12-07 | Follow-up Inspection | No Violations Noted | Upon inspection I found this new well in production, with the annulus open and the following production equipment installed: 210 bbl steel tank- separator- all inside a lined, earthen dike. The well pad was partially reclaimed with the pits closed and ground surface graded. I called operator Jeff Foley, re: a minor E&S problem near north end of well pad, along the access road- I asked Jeff to have slit fence installed ahead of culvert pipe. Operator will finish reclaim in Spring 2012. |
2049076 | Primary Facility | 2012-03-06 | Administrative/File Review | Violation(s) Noted | |
2069107 | Primary Facility | 2012-05-18 | Site Restoration | No Violations Noted | |
2070126 | Primary Facility | 2012-05-21 | Complaint Inspection | No Violations Noted | |
2076251 | Primary Facility | 2012-06-16 | Site Restoration | No Violations Noted | |
2082891 | Primary Facility | 2012-07-11 | Complaint Inspection | No Violations Noted | |
2187238 | Primary Facility | 2013-07-26 | Routine/Partial Inspection | No Violations Noted | |
2452174 | Primary Facility | 2016-02-18 | Routine/Complete Inspection | No Violations Noted | |
2540932 | Primary Facility | 2016-12-02 | Administrative/File Review | No Violations Noted | production review |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2049076 | 633770 | 03/06/2012 | 2012-03-06 | 212WELLRCD - Failure to submit well record within 30 days of completion of drilling | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
633770 | 281260 | NOV - Notice of Violation | Comply/Closed | 2012-03-23 |
For data sources see[7]