37-105-21193

Well Details

Well ID: 37-105-21193
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Roulette Township
Operator Name: ROULETTE OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: LYMAN YX118
License Status: ACTIVE
Spud Date:
Permit Date: 2006-03-14
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.7825
Longitude: -78.149577

For data sources see[1][2][3]

Well History

Date Event
2006-03-14 New Permit Application
2006-05-18 Performed Spud Operation
2006-05-24 Drilling Completion
2006-11-16 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2006 GUARDIAN EXPLORATION LLC 4570.00 184 0.00 0 0.00 0
2007 GUARDIAN EXPLORATION LLC 6263.00 365 0.00 0 0.00 0
2008 GUARDIAN EXPLORATION LLC 5969.00 366 0.00 0 0.00 0
2009 GUARDIAN EXPLORATION LLC 5702.00 365 0.00 0 0.00 0
2010 GUARDIAN EXPLORATION LLC 5,266.00 365 0.00 0 0.00 0
2011 GUARDIAN EXPLORATION LLC 4,673.00 365 0.00 0 0.00 0
2012 JJ BUCHER PRODUCING CORP 0.00 0 0.00 0 0.00 0
2013 JJ BUCHER PRODUCING CORP 0.00 0 0.00 0 0.00 0
2014 ROULETTE OIL & GAS LLC 2,645.00 365 0.00 0 0.00 0
2015 ROULETTE OIL & GAS LLC 2,304.00 365 0.00 0 0.00 0
2016 ROULETTE OIL & GAS LLC 2,155.50 365 0.00 0 0.00 0
2017 ROULETTE OIL & GAS LLC 1,816.50 365 0.00 0 0.00 0
2018 ROULETTE OIL & GAS LLC 1,969.50 365 0.00 0 0.00 0
2019 ROULETTE OIL & GAS LLC 1,776.50 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2006 GUARDIAN EXPLORATION LLC Drilling 34.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2006 GUARDIAN EXPLORATION LLC Brine 102.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2008 GUARDIAN EXPLORATION LLC Brine 43.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2010 GUARDIAN EXPLORATION LLC Produced Fluid 76.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 GUARDIAN EXPLORATION LLC Produced Fluid 38.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014 ROULETTE OIL & GAS LLC Produced Fluid 50.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2019 ROULETTE OIL & GAS LLC Produced Fluid 75.00 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1539844 Primary Facility 2006-05-22 Drilling/Alteration No Violations Noted
1551489 Primary Facility 2006-07-17 Routine/Complete Inspection No Violations Noted
1558564 Primary Facility 2006-08-09 Routine/Complete Inspection No Violations Noted
1558600 Primary Facility 2006-08-11 Site Restoration No Violations Noted
2401189 Primary Facility 2015-08-19 Routine/Complete Inspection No Violations Noted
2552379 Primary Facility 2017-01-13 Routine/Complete Inspection No Violations Noted
2582095 Primary Facility 2017-04-12 Routine/Complete Inspection No Violations Noted
2590614 Primary Facility 2017-05-01 Routine/Complete Inspection No Violations Noted
2672066 Primary Facility 2017-12-15 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly all fittings and flow lines were tested with a gas meter. Results of this testing were no gas detected on the wellhead assembly and well area.
2731271 Primary Facility 2018-05-17 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production
2812366 Primary Facility 2018-12-10 Routine/Complete Inspection No Violations Noted At the time of this inspection this well appeared to be in production. Wellhead assembly is a approximate 10" casing out of the ground with a threaded approximate 7 1/2" casing inside of casing out of the ground with a hammer style fitting attached to the threaded end of casing that is approximately 7 1/2"x2"x2".This fitting has a approximate 2" valve on one side that is shut and approximately a 2" production flow line on the other side with a 2" valve that is open going into a filter a meter and a double desiccant (dryer) tank system then in a drip tank then into a production flow line and into the ground. No violations noted at this inspection.

For data sources see[7]

References