37-115-22141

Well Details

Well ID: 37-115-22141
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Great Bend Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 153149
Farm/Lease Name: TRETTER 2H
License Status:
Spud Date: 2018-03-03
Permit Date: 2015-12-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.912056
Longitude: -75.648958

For data sources see[1][2][3]

Well History

Date Event
Deviated
2015-12-17 New Permit Application
2016-10-26 New Permit Application
2017-12-06 Permit Renewal Application
2018-03-01 Performed Spud Operation
2018-05-11 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-05-30 2018-06-17 6,326 12,335,600 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Southwestern Energy Carrier/Base Fluid Water 7732-18-5 100 83.9 102,879,000.0
HCL Acid (12.6%-17.5%) U.S. Well Services, LLC Bulk Acid Hydrogen Chloride 7647-01-0 17.5 0.182804 224156
Water 7732-18-5 87.4 0.786261 964120
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 15.0081 18,403,100.0
K-BAC 1005 U.S. Well Services, LLC Anti-Bacterial Agent Polyethylene Glycol 25322-68-3 50 0.006631 8131.17
Water 7732-18-5 44.3 0.005246 6432.33
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 5.76 0.001672 2049.89
SI-1200s U.S. Well Services, LLC Scale Inhibitor Proprietary Scale Inhibitor Proprietary 10 0.001223 1499.28
LT FLUSH SYSTEM I U.S. Well Services, LLC Other Mineral oil, petroleum distillates,
hrdotreated light naphthenic
64742-53-6 100 0.000425 521.083
WFRA-2000 U.S. Well Services, LLC Friction Reducer Water 7732-18-5 60 0.056063 68745
Hydrated light distillate (petroleum) 64742-47-8 30 0.022986 28185.4
2-Propenoic acid, polymer with 2 propenamide 9003-06-9 30 0.028032 34372.5
AI-303 U.S. Well Services, LLC Acid Corrosion Inhibitors Formic acid 64-18-6 20 0.00009000 110.588
Acetophenone,thiourea,formaldehyde polymer 68527-49-1 5 0.00002300 27.6471
Polyether 60828-78-6 10 0.00004500 55.2942
Ethylene glycol 107-21-1 40 0.000258 316.283
Butyl cellosolve 111-76-2 20 0.00008100 99.6402
Cinnamaldehyde 104-55-2 20 0.00009300 114.348

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 SWN PROD CO LLC 2,307,185.00 168 0.00 0 0.00 0
2019 SWN PROD CO LLC 2,527,039.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 SWN PROD CO LLC Produced Fluid 6,032.18 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 81.33 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 90.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWN PROD CO LLC Unused Fracturing Fluid Waste 3.43 Tons LANDFILL 100933
2018 SWN PROD CO LLC Produced Fluid 143.60 Tons LANDFILL 301358
2018 SWN PROD CO LLC Produced Fluid 6,490.99 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Synthetic Liner Materials 4.81 Tons LANDFILL 101247
2018 SWN PROD CO LLC Drilling Fluid Waste 1,010.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Drilling Fluid Waste 800.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 520.56 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 40.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Drill Cuttings 1,321.62 Tons LANDFILL 101247
2018 SWN PROD CO LLC Produced Fluid 254.33 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 27.08 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 2,276.82 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 138.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 953.17 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2534064 Primary Facility 2016-11-01 Preoperation Inspection No Violations Noted On 11/1/16, the Department was on site at the SWN RU 74 Tretter Well Pad to conduct a Preoperational Inspection. Inspection conducted with Rich Gulyas, SWN Construction Foreman, Andy Breese, SWN Construction Foreman, and Seth Tratthen, Regulatory Analyst. The well permits that have been issued for this pad are the Tretter 1H (115-22140), the 2H (115-22141), and the 3H (115-22142). All perimeter BMP’s in place to include red lined additions. Pad is 100% complete. Approximately 75% of slopes rock stabilized. No violations noted.
2575796 Primary Facility 2017-03-21 Routine/Complete Inspection No Violations Noted The Department was on site to conduct an inspection. At the time of the inspection, the site was covered in snow. It was noted that clearing has been started for the pipeline adjacent to this site. Additionally, on 3/20/17 the Department received notification that the SPUD notification for the 2H and 1H wells have been deleted.
2703559 Primary Facility 2018-03-05 Drilling/Alteration No Violations Noted At time of inspection.

I was on site for a new spud inspection. Minichi Contracting Group was on site, they drilled and set the conductor pipe for the Tretter 1H and 2H wells with a dual rotary rig. I met with driller Keith Bowman. The 1H was drilled and set at 88'. The 2H was drilled and set at 75'. Drill cuttings were put in a sealed rolloff container and hauled to the Keystone landfill. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2709997 Primary Facility 2018-03-26 Drilling/Alteration No Violations Noted At time of inspection.

Met with company man Robert Gray. Falcon 24 was set up on the Tretter 1H and WOC for the surface casing. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2740025 Primary Facility 2018-06-11 Routine/Complete Inspection No Violations Noted At time of inspection.

Met with company man Jeff Voltz. USWS was on site to frac the Tretter 1H, 2H and Walker West 1H. The Walker West 1H was completed with 24 stages. The Tretter 1H was completed with 40 stages. There were 35 stages completed out of 45 on the Tretter 2H. They were shut down and waiting for a coaled tubing rig when I arrived on location. The plug was set high after stage 35 at 8013' with perforations above the plug in the Tretter 2H, they plan on drilling out the plug and resume stimulation on the well. The water is being pumped to the location from the Young fresh water impoundment and some being pumped from the flow back at the Breese pad. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2744325 Primary Facility 2018-06-14 Routine/Complete Inspection No Violations Noted The Department arrived at 1415 to perform a RTNC inspection on the pad. Present to represent the Department were Gene Rickard (WQS-DEP) and myself.

Upon arrival at the site, Mr. Rickard and I signed in at the guard station. We asked the guard what type of activity was currently being performed at the pad, as we did not want to enter the site if well stimulation was actively being performed. She informed us that well stimulation had been underway earlier in the week, but the crew had encountered a problem and had put well stimulation on hold while they corrected it. She was not aware of the exact nature of the problem.

After parking our vehicle, we tracked down Travis Dye (Well Site Supervisor-SWN) in order to find out exactly what type of problem they had encountered and what type of corrective actions were being performed. Mr. Dye informed us that while performing well stimulation activities on the 2H, SWN discovered one of the plugs had not been set properly. In order to continue well stimulation, the

2745273 Primary Facility 2018-06-20 Routine/Complete Inspection No Violations Noted Today's inspection was conducted in response to SWN's self reporting of the failure of secondary containment emplaced for the containment of the tank battery that had been set up for fracking operations. The containment failed during a storm event and released what was reported to be approximately 4200 gallons of rainwater. As photo's 3 and 4 show, some gravel material had been mobilized, but none was observed to have left the site. After flowback operations are complete, the Department expects SWN will repair the minor damage that has occurred in this location. Well tender Shane Beamer stated that fracing operations finished up either yesterday or the day before. The original 3 wells have just been placed back into production. Production equipmment for the other 3 new wells is almost complete. Flow back operations on the wells have not commenced yet. No violations were observed during this inspection.
2771105 Primary Facility 2018-09-04 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was recently completed and put in production. The well tag was on the well and correct. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 3.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. There were 18 empty 500bbl tanks on containment and the containment appeared to be in good condition. There was a single empty 500bbl tank not on containment. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2819971 Primary Facility 2018-12-27 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. All 6 wells appear to be in production. No E&S issues identified. Good vegetative stabilization present. Site is approximately 80% stone stabilized. No violations present.

For data sources see[8]