Well ID: 37-115-22142 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.912122,"lon":-75.648758,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Great Bend Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 153149 | |
Farm/Lease Name: TRETTER 3H | |
License Status: | |
Spud Date: 2017-03-04 | |
Permit Date: 2015-12-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.912122 | |
Longitude: -75.648758 |
Date | Event |
---|---|
Deviated | |
2015-12-17 | New Permit Application |
2016-10-26 | New Permit Application |
2017-03-03 | Performed Spud Operation |
2017-07-11 | Drilling Completion |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-09-20 | 2017-09-28 | 6,394 | 11,435,600 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SAND-COMMON WHITE - 100 MESH, 3307 LB BAG | Halliburton | Proppant | Listed Below | ||||
HAI-150E | Halliburton | Corrosion Inhibitor | Listed Below | |||||
Fresh Water | Operator | Base Fluid | Listed Below | |||||
Inorganic salt | Proprietary | 30 | 0.0300694 | 33497 | ||||
Diammonium phosphate | 7783-28-0 | 5 | 0.00114876 | 1280 | ||||
Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.0023238 | 2589 | ||||
Organic phosphonate | Proprietary | 60 | 0.0137851 | 15357 | ||||
Ammonium chloride | 12125-02-9 | 30 | 0.00689255 | 7679 | ||||
Water | 7732-18-5 | 100 | 1.01219 | 1,127,550.0 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0300694 | 33497 | ||||
Non-hazardous food substance | Proprietary | 100 | 0.000697949 | 778 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.13725 | 152898 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 13.4259 | 14,956,200.0 | ||||
Acrylamide acrylate copolymer | Proprietary | 30 | 0.0300694 | 33497 | ||||
Water | 7732-18-5 | 100 | 85.5119 | 95,258,300.0 | ||||
SAND-PREMIUM WHITE-30/50, BULK | Halliburton | Proppant | Listed Below | |||||
FR-76 | Halliburton | Friction Reducer | Listed Below | |||||
LP-65 MC | Halliburton | Scale Inhibitor | Listed Below | |||||
BE-9 | Halliburton | Biocide | Listed Below | |||||
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | |||||
Ingredients | Listed Above | Listed Above | Listed Below |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | SWN PROD CO LLC | 1,379,459.00 | 75 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 2,860,781.00 | 344 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 1,513,629.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 55.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Synthetic Liner Materials | 8.56 Tons | LANDFILL | 101247 |
2017 | SWN PROD CO LLC | Drilling Fluid Waste | 1,121.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Unused Fracturing Fluid Waste | 51.86 Tons | LANDFILL | 100933 |
2017 | SWN PROD CO LLC | Produced Fluid | 22,518.84 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Produced Fluid | 37.87 Tons | LANDFILL | 301358 |
2017 | SWN PROD CO LLC | Produced Fluid | 27.50 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Drilling Fluid Waste | 1,750.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 1,887.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Drill Cuttings | 1,821.39 Tons | LANDFILL | 101247 |
2017 | SWN PROD CO LLC | Produced Fluid | 240.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | SWN PROD CO LLC | Produced Fluid | 11,324.01 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 268.33 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 1,286.32 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 5,157.66 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 777.23 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 78.33 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 27.08 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 2,276.82 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 953.17 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Produced Fluid | 138.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2534065 | Primary Facility | 2016-11-01 | Preoperation Inspection | No Violations Noted | On 11/1/16, the Department was on site at the SWN RU 74 Tretter Well Pad to conduct a Preoperational Inspection. Inspection conducted with Rich Gulyas, SWN Construction Foreman, Andy Breese, SWN Construction Foreman, and Seth Tratthen, Regulatory Analyst. The well permits that have been issued for this pad are the Tretter 1H (115-22140), the 2H (115-22141), and the 3H (115-22142). All perimeter BMP’s in place to include red lined additions. Pad is 100% complete. Approximately 75% of slopes rock stabilized. No violations noted. |
2569529 | Primary Facility | 2017-03-06 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 9:00a.m. for a new spud inspection.
Minichi Contracting Group was on site to drill the holes and run the conductor pipe. I spoke with driller Keith Bowman of Minichi, the rig was drilling the hole for the 5H, they were at a depth of 61'. The Walker West 1H was completed at a depth of 70', the Walker West 6H was completed at a depth of 71' and the Tretter 3H was completed at a depth of 72'. The drill cuttings are being put into a sealed role off container and hauled to the Keystone Landfill. I took a walk around the location and there were no obvious concerns noticed. I left the site at 9:30a.m. |
2575798 | Primary Facility | 2017-03-21 | Routine/Complete Inspection | No Violations Noted | The Department was on site to conduct an inspection. At the time of the inspection, the site was covered in snow. It was noted that clearing has been started for the pipeline adjacent to this site. Additionally, on 3/20/17 the Department received notification that the SPUD notification for the 2H and 1H wells have been deleted. |
2593808 | Primary Facility | 2017-05-11 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 12:05p.m.
I met with company men Kevin Heathcock. Falcon Rig 25 was on site and running drill pipe back in the hole and started drilling out the plug. I took a walk around the location and there were no obvious concerns noticed. Depth at time of inspection was 1642'. The projected TD for the top hole section of the well is 4900'. I left the site at 13:15p.m. |
2613970 | Primary Facility | 2017-07-10 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 9:4a.m.
I met with company men John Woodburn. SDC Rig#45 was on site and drilling the lateral section of the production hole. The top-hole section of the well was drilled and completed by Falcon Rig#25 on 5/13/17. I took a walk around the location and there were no obvious concerns noticed. Depth at time of inspection was 15,599'. The projected TD for the well is 15,858'. I left the site at 10:35a.m. |
2631796 | Primary Facility | 2017-09-01 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
I met with company men Paul Woodall and Aron Lash. Halliburton was on site to stimulate the Tretter 3H, Walker West 5H and 6H. They were on the 6H and completed stage 31 out of 65 stages. They completed 7 stages out of 54 on the 5H before losing the perf gun in the hole. The 3H hasn't been started yet but will have 37 stages. The water is being pumped in from the Young fresh water impoundment. I took walk around the location and there were no obvious concerns noticed. |
2674609 | Primary Facility | 2017-12-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was recently completed and put in production. The well tag was on the well and correct. The cellar was set up with a corrugated pipe around the well for inspection access. There was cement at the (20x13) and (13x9) annuli and there was no gas detected. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2744327 | Primary Facility | 2018-06-14 | Routine/Complete Inspection | No Violations Noted | The Department arrived at 1415 to perform a RTNC inspection on the pad. Present to represent the Department were Gene Rickard (WQS-DEP) and myself.
Upon arrival at the site, Mr. Rickard and I signed in at the guard station. We asked the guard what type of activity was currently being performed at the pad, as we did not want to enter the site if well stimulation was actively being performed. She informed us that well stimulation had been underway earlier in the week, but the crew had encountered a problem and had put well stimulation on hold while they corrected it. She was not aware of the exact nature of the problem. After parking our vehicle, we tracked down Travis Dye (Well Site Supervisor-SWN) in order to find out exactly what type of problem they had encountered and what type of corrective actions were being performed. Mr. Dye informed us that while performing well stimulation activities on the 2H, SWN discovered one of the plugs had not been set properly. In order to continue well stimulation, the |
2745275 | Primary Facility | 2018-06-20 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted in response to SWN's self reporting of the failure of secondary containment emplaced for the containment of the tank battery that had been set up for fracking operations. The containment failed during a storm event and released what was reported to be approximately 4200 gallons of rainwater. As photo's 3 and 4 show, some gravel material had been mobilized, but none was observed to have left the site. After flowback operations are complete, the Department expects SWN will repair the minor damage that has occurred in this location. Well tender Shane Beamer stated that fracing operations finished up either yesterday or the day before. The original 3 wells have just been placed back into production. Production equipmment for the other 3 new wells is almost complete. Flow back operations on the wells have not commenced yet. No violations were observed during this inspection. |
2771109 | Primary Facility | 2018-09-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 2' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. There were 18 empty 500bbl tanks on containment and the containment appeared to be in good condition. There was a single empty 500bbl tank not on containment. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2819976 | Primary Facility | 2018-12-27 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. All 6 wells appear to be in production. No E&S issues identified. Good vegetative stabilization present. Site is approximately 80% stone stabilized. No violations present. |
For data sources see[8]