37-117-20975

Well Details

Well ID: 37-117-20975
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Duncan Township
Operator Name: EQT PROD CO
Well Pad ID: 149048
Farm/Lease Name: PHOENIX 590884
License Status:
Spud Date:
Permit Date: 2010-10-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.649833
Longitude: -77.265239

For data sources see[1][2][3]

Well History

Date Event
2010-10-28 New Permit Application
2011-10-04 Performed Spud Operation
2011-10-25 Permit Renewal Application
2012-01-15 Drilling Completion
2012-06-19 Perforation
2014-02-12 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-06-27 2012-06-27 7,757 12,205,494

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 LP-65 Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10.0 0.00267
WG-36 Halliburton Gelling Agent Naptha, hydrotreated heavy 64742-48-9 None None
Guar Gum 9000-30-0 100.0 0.00476
GBW-30 Halliburton Enzyme Breaker Hemicellulase Enzyme 9012-54-8 15.0 None
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10.0 0.00429
SP Breaker Halliburton Oxidizing Breaker Sodium Persulfate 7775-27-1 100.0 0.00019
HCl Halliburton 15 HCl Acid Methanol 67-56-1 60.0 0.00024
Hydrochloric Acid 7647-01-0 28.0 0.02468
Propargyl Alcohol 107-19-7 10.0 0.00004000
HCl Halliburton Corrosion Inhibitor
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30.0 0.02972
BA-40L Halliburton Buffer Potassium carbonate 584-08-7 60.0 0.0087

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 471,588.00 146 0.00 0 0.00 0
2013 EQT PROD CO 631,163.00 365 0.00 0 0.00 0
2014 EQT PROD CO 437,506.00 365 0.00 0 0.00 0
2015 EQT PROD CO 377,883.00 316 0.00 0 0.00 0
2016 EQT PROD CO 360,508.00 364 0.00 0 0.00 0
2017 EQT PROD CO 309,110.00 364 0.00 0 0.00 0
2018 EQT PROD CO 258,660.00 350 0.00 0 0.00 0
2019 EQT PROD CO 231,278.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EQT PROD CO Drilling Fluid Waste 110.00 Bbl INJECTION DISPOSAL WELL 34-049-23127
2011 EQT PROD CO Fracing Fluid Waste 340.00 Bbl INJECTION DISPOSAL WELL 34-049-23127
2012 EQT PROD CO Produced Fluid 3,460.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012 EQT PROD CO Produced Fluid 13,705.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EQT PROD CO Drilling Fluid Waste 231.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EQT PROD CO Produced Fluid 564.00 Bbl INJECTION DISPOSAL WELL 34-083-24137
2012 EQT PROD CO Produced Fluid 6,694.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Drilling Fluid Waste 420.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 6,995.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 EQT PROD CO Fracing Fluid Waste 1,106.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 416.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 EQT PROD CO Produced Fluid 1,279.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2012 EQT PROD CO Fracing Fluid Waste 721.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EQT PROD CO Produced Fluid 1,787.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 301.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2013 EQT PROD CO Produced Fluid 3,918.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 EQT PROD CO Produced Fluid 3,838.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EQT PROD CO Produced Fluid 2,285.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 EQT PROD CO Produced Fluid 826.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 EQT PROD CO Produced Fluid 924.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2014 EQT PROD CO Produced Fluid 321.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 6,867.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 461.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2015 EQT PROD CO Produced Fluid 405.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 EQT PROD CO Produced Fluid 376.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2015 EQT PROD CO Produced Fluid 3,124.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 23.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 1,870.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 EQT PROD CO Other Oil & Gas Wastes 220.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 EQT PROD CO Produced Fluid 1,691.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 1,052.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 1,381.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Other Oil & Gas Wastes 563.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 280.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 EQT PROD CO Other Oil & Gas Wastes 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Produced Fluid 300.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 142.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 155.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 173.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 71.38 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 92.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 66.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 817.58 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 41.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Produced Fluid 416.11 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 9.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 EQT PROD CO Produced Fluid 140.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 100.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 146.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Produced Fluid 48.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Other Oil & Gas Wastes 649.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Produced Fluid 62.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Other Oil & Gas Wastes 2.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Other Oil & Gas Wastes 92.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 34.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 21.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 1,188.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Produced Fluid 31.12 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 92.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1974931 Primary Facility 2011-05-13 Routine/Complete Inspection No Violations Noted RTNC Insp. Viols against 883 well (#1974299)
2001174 Primary Facility 2011-08-30 Routine/Complete Inspection No Violations Noted Insp conducted to resolve viols under 117-20974. TLT
2022816 Primary Facility 2011-11-29 Drilling/Alteration No Violations Noted
2028269 Primary Facility 2011-12-20 Drilling/Alteration No Violations Noted
2034358 Primary Facility 2012-01-11 Drilling/Alteration No Violations Noted
2066471 Primary Facility 2012-05-09 Routine/Complete Inspection No Violations Noted
2126727 Primary Facility 2012-12-28 Routine/Partial Inspection No Violations Noted
2139754 Primary Facility 2013-02-06 Routine/Partial Inspection No Violations Noted
2145015 Primary Facility 2013-03-01 Routine/Partial Inspection No Violations Noted
2230367 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2254693 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2319524 Primary Facility 2014-11-06 Routine/Complete Inspection No Violations Noted
2328165 Primary Facility 2014-11-25 Routine/Partial Inspection No Violations Noted Drill rig recently moved off site. Site preparation and mobilization for frac ongoing during inspection. TLT
2336080 Primary Facility 2015-01-13 Administrative/File Review No Violations Noted Review of lab results for samples collected on 11/25/14 from standing water on pad surface following drilling operations. Results show concentrations that exceed Department standards for constituents indicative of oil and gas operations. Violations cited against Phoenix 590888 well permit (117-20981) TLT.
2343268 Primary Facility 2015-02-11 Routine/Complete Inspection No Violations Noted
2352472 Primary Facility 2015-03-11 Routine/Partial Inspection No Violations Noted Violation cited against Phoenix 590888 well (117-20981) during 3/11/15 inspection for failure to maintain E&S controls to prevent the potential for accelerated erosion and sedimentation. Access road to the site not maintained to prevent tracking of mud onto State Route 3009. Equipment mobilized to site the next day to sweep SR 3009 and improve stabilization on the access road. Violation immediately corrected. TLT
2367826 Primary Facility 2015-05-04 Follow-up Inspection No Violations Noted Follow up inspection to resolve 1/13/15 violations. New violations observed and cited against Phoenix 590888 well (117-20981). TLT
2375725 Primary Facility 2015-05-29 Follow-up Inspection No Violations Noted Follow up inspection to verify whether 5/4/15 violations (cited against 117-20981) have been resolved. Stained material still present. Sample 2519-626 collected. TLT
2407347 Primary Facility 2015-09-14 Follow-up Inspection No Violations Noted Follow up inspection to resolve the 5/4/15 violations against the Phoenix 590888 well (117-20981). EQT provided a follow up response on 6/8/15 that included soil sample results to document the cleanup. Concentrations were below applicable standards. 5/29/15 Department results were also below the applicable standards. TLT
2511838 Primary Facility 2016-08-16 Routine/Partial Inspection No Violations Noted Partial inspection to observe reclamation of Impoundment #1. Impoundment dewatered and liner removed. Gray subbase material observed on impoundment walls and floor. Field conductivity screening completed of standing water and impoundment floor soil. No violations cited. TLT
2530382 Primary Facility 2016-10-14 Routine/Complete Inspection No Violations Noted Routine inspection. Both freshwater impoundments and topsoil stockpile have been reclaimed. The east and south well pad corner sumps have been removed and an infiltration basin constructed southeast of the well pad. No violations cited. TLT
2531657 Primary Facility 2016-10-26 Routine/Complete Inspection No Violations Noted Inspection of EQT’s Phoenix 590997 (117-20977) plugged well in Duncan Twp. Tioga Co. conducted October 26, 2016 at 12:15 pm. At the time of inspection; the cellar was filled with water with 3” tagged standpipe monument about 8’ high. The top of the monument was open ended “T”, ran hose for Altair 5x gas meter in the vent; no gas detected. There were (7) active gas wells in production on the pad; #590885 (117-20966), #590884 (117-20975), #590883 (117-20974), #590892 (117-20985), #590890 (117-20983), #590889 (117-20982), #590888 (117-20981). Conducted visual inspection of WH and cellar; no obvious conecrns.
2535685 Primary Facility 2016-11-03 Site Restoration No Violations Noted Well Site Restoration Reports (WSRRs) received on 11/1/16. Since the new 25 Pa Code Ch. 78a regulations are in effect, WSRR's are to be submitted on the updated form through the Greenport website. This information was conveyed to EQT along with the request that the WSRRs be submitted electronically on the updated form. Interim restoration has been completed at the site and vegetative cover is becoming established. TLT
2544168 Primary Facility 2016-12-06 Site Restoration No Violations Noted Restoration inspection. Notice of Termination (NOT) received on 11/16/16 and Well Site Restoration Report submitted through Greenport on 12/6/16. Post-construction stormwater management BMPs have been installed. Vegetation is becoming established, however, entire site has not achieved 70% uniform vegetative cover and silt sock remains in place at the former Impoundment #1 location. Recommend that NOT be denied. Recommend that the NOT and WSRR be resubmitted after vegetation becomes more established and silt sock is removed. TLT
2551757 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted
2596524 Primary Facility 2017-05-19 Site Restoration No Violations Noted On 5/19/17 at 1402 hrs I conducted an inspection of the Phoenix Pad R well site. No one was present during the inspection. It was mostly sunny and 84°F.

I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR).

The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed. Temporary E&S controls have been removed and the project is permanently stabilized as per 25 Pa Code Section 102.22(a)(2). The last routine E&S inspection was conducted on 5/15/17.

Based on existing conditions, I recommend approval of the NOT. The WSRR was approved on 5/22/17. No violations were cited during this inspection. I concluded the inspection at 1433 hrs. TLT

2678328 Primary Facility 2018-01-04 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the EQT Phoenix pad R located in Duncan Township, Tioga County on January 4, 2018 at 1130 hrs. The weather was 16 degrees. Overcast with 3 inches of snow on the ground. 22 mph winds out of the NW. Humidity 61%. Pressure 29.7 inHg.

No activity was observed on site during the inspection. There appear to be seven active wells on the pad 590883-590885, 590888-590890, 590892. An AST labeled "freshwater only" was observed onsite. Containment with matting was observed under the hoses. A number of water trucks were idling onsite.

No issues were observed. No violations were noted at this time. I departed the site at 1330 hours.

2702160 Primary Facility 2018-03-06 Routine/Partial Inspection No Violations Noted The department of environmental protection conducted an inspection of the EQT Phoenix pad R in response to report of a spill to the ground surface received March 3, 2018 @1315 hours. Present onsite was Jim Kelley, EQT Assistant Superintendent.

A stuck dump valve caused an overfill of a 100 BBL capacity storage tank. EQT estimated the spill of produced water to be between 30-40 gallons. The fluid settled in a low area on the pad surface adjacent to the tank. The impacted area, approximately 15' x 5' x 10", was excavated and "burrito" wrapped in plastic until a waste rolloff container was delivered.

As of today's inspection, the impacted material has been moved to the rolloff container. The excavated area has been backfilled with clean gravel. Mr. Kelley reported the malfunctioning valve has been repaired. A copy of the monthly tank inspection report, required under 25 Pa Code 78a.57(i), was requested from the Operator.

I departed the site at 1400 hours.

2807923 Primary Facility 2018-11-28 Routine/Partial Inspection No Violations Noted The DEP conducted an INCIDENT inspection of the EQT Pad R site located in Duncan Twp, Tioga Co. on 10/28/2018 at 1015 hours in response to spill notification #338402.

Cory Guiles of EQT reported that at 2:40 pm on 11/27/2018, "there was a release of hydraulic fluid to the pad surface. There was a mechanical failure on a water truck that allowed 20 gallons of hydraulic fluid to be released to the pad surface of Phoenix R. They are in the process of cleaning up the impacted soil now and will store it in drums."

As of today's inspection, no personnel were located onsite. I contacted Corey Giles, EQT to confirm the location of the spill. He stated he was under the impression it was in front of the production tanks, approximately 1 barrel of material was removed and had already been backfilled with clean material. During the course of the inspection Tim Ryan, EQT well tender appeared onsite and showed me the location of the spill. A small area adjacent to the well heads appears to have been recently disturbed.

For data sources see[8]

References