X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21317

Well Details

Well ID: 37-117-21317
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Chatham Township
Operator Name: SWEPI LP
Well Pad ID: 149542
Farm/Lease Name: WATKINS V 820 5H
License Status:
Spud Date:
Permit Date: 2011-09-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.893481
Longitude: -77.410436

For data sources see[1][2][3]

Well History

Date Event
2011-09-28 New Permit Application
2011-10-03 Performed Spud Operation
2011-11-14 Drilling Completion
2012-12-13 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-28 2011-12-28 4,698 2,718,996

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand Badger Mining Co. Proppant Quartz 14808-60-7 99.90 5.88
FE-4 Univar Iron Control/Reducer Citric acid 77-92-9 50.00 0.00055000
Water 7732-18-5 50.00 0.00055000
PetroFlow Bio-Cide International Biocide Sodium chlorite 7758-19-2 8.35 0.00387000
Plexgel Breaker Chemplex Enzyme Breaker not classified as hazardous 100.00 0.00019000
I-22 Nalco Acid Corrosion Inhibitor Methanol 67-56-1 5.00 0.00002000
Aromatic aldehyde 30.00 0.00011000
Benzyl chloride 100-44-7 1.00 0.00001000
Haloalkyl heteropolycycle salt 30.00 0.00011000
Oxyalkylated Fatty Acid 30.00 0.00011000
Isopropanol 67-63-0 5.00 0.00002000
Formic acid 64-18-6 60.00 0.00022000
Quaternary ammonium compounds 5.00 0.00002000
Organic sulfur compounds 5.00 0.00002000
MSI-7 National Petrochemical Scale Inhibitor Hydorgen Chloride 0.00933000
Plex 907 Chemplex Gelling Agent/Thickener vegetable gums 100.00 0.01
Hydrochloric Acid Reagent Chemical & Research Hydrochloric acid 7647-01-0 15.00 0.05
Water 85.00 0.31
Water Shell 100.00 93.57
FR-900 Nalco Scale Inhibitor not classified as hazardous 100.00 0.09

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 140,764.33 327 0.00 0 0.00 0
2013 SWEPI LP 120,667.54 277 0.00 0 0.00 0
2014 SWEPI LP 46,907.28 111 0.00 0 0.00 0
2015 SWEPI LP 38,984.91 29 0.00 0 0.00 0
2016 SWEPI LP 87,192.71 115 0.00 0 0.00 0
2017 SWEPI LP 75,861.19 98 0.00 0 0.00 0
2018 SWEPI LP 54,441.41 82 0.00 0 0.00 0
2019 SWEPI LP 54,913.33 116 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Produced Fluid 7,343.74 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Produced Fluid 55.95 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Fracing Fluid Waste 7,577.45 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 713.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Fracing Fluid Waste 446.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 SWEPI LP Produced Fluid 3,863.60 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Produced Fluid 182.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Produced Fluid 460.91 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Fracing Fluid Waste 82.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Fracing Fluid Waste 0.63 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2014 SWEPI LP Drilling Fluid Waste 473.20 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Fracing Fluid Waste 3,146.42 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Drilling Fluid Waste 194.03 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Produced Fluid 742.13 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 16.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 SWEPI LP Produced Fluid 33.44 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Drilling Fluid Waste 17.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 SWEPI LP Drill Cuttings 873.54 Tons LANDFILL 301358
2015 SWEPI LP Produced Fluid 239.85 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 1,305.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 261.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SWEPI LP Fracing Fluid Waste 0.20 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 5,910.20 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Waste Water Treatment Sludge 4.94 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 SWEPI LP Produced Fluid 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 SWEPI LP Produced Fluid 4,779.60 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWEPI LP Produced Fluid 58.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 SWEPI LP Waste Water Treatment Sludge 2.83 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SWEPI LP Produced Fluid 2,206.00 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid 744.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 357.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Soil Contaminated by Oil 0.01 Tons RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2018 SWEPI LP Soil Contaminated by Oil & Gas Related Spills 0.01 Tons RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2018 SWEPI LP Produced Fluid 846.00 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Waste Water Treatment Sludge 6.22 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWEPI LP Produced Fluid 463.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 SWEPI LP Produced Fluid 38.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 SWEPI LP Produced Fluid 80.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 SWEPI LP Produced Fluid 24.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 206.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Produced Fluid 1,083.50 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2036095 Primary Facility 2012-01-18 Routine/Complete Inspection No Violations Noted
2059646 Primary Facility 2012-04-12 Routine/Complete Inspection No Violations Noted
2060155 Primary Facility 2012-04-16 Routine/Complete Inspection No Violations Noted
2202053 Primary Facility 2013-09-03 Routine/Partial Inspection No Violations Noted An inspection of the Watkins 820 site in Chatham Township, Tioga County was conducted on September 3, 2013. The last inspection conducted on behalf of the operator was on August 12, 2013. These inspection are required weekly or following a significant rain event. The Watkins V 820 5H and Watkins V 820 5HS wells was drilled. The Watkins 820 25H well's permit status is Active, but not yet drilled. The status of the permits for the Watkins 820 2H, 3H, 4H, 5H and 6H wells are listed as "Operator Reported Not Drilled". No puddles exhibiting elevated conductivity were observed at this time. The site was well vegetated and no erosion issues were noted. No violations were cited during this inspection. - MRN
2206869 Primary Facility 2013-09-24 Routine/Complete Inspection No Violations Noted
2252296 Primary Facility 2014-02-12 Routine/Complete Inspection No Violations Noted
2258281 Primary Facility 2014-03-24 Drilling/Alteration No Violations Noted
2313019 Primary Facility 2014-10-15 Routine/Complete Inspection No Violations Noted
2316970 Primary Facility 2014-10-29 Complaint Inspection No Violations Noted The Department inspected the Watkins 820, permit# ESX11-117-0019, in Chatham Twp., Tioga Co. on 10/29/14 @ 1110 hours in response to a water supply complaint. The weather was 52 degrees and overcast. Present onsite were Jonathan Pennings, DEP WQS and Mike Parker, OSR Swepi LP. No oil and gas activity was taking place onsite during the inspection. A hydro excavator was onsite looking for utility lines buried beneath the pad surface. Mr. Parker stated staged fracking had been completed on the Watkins 820 23H and 25H wells, both Utica wells, between 9/28/14 and 10/18/14. They were hoping to frack the Watkins 21H in the next few days, also a Utica well. He also stated the two Marcellus wells, the Watkins 5H and 5HS were “shut in”. The Watkins 2H through 6H wells were listed as “operator reported not drilled”.
2328181 Primary Facility 2014-12-08 Incident- Response to Accident or Event No Violations Noted The SWEPI, LP Watkins 820 site in Chatham Twp., Tioga Co. was inspected by the Department @ 1230 hours on 12/8/14. The weather was 28 degrees with strong winds out of the southeast. Personnel onsite included Terra Tokarz, DEP WQS, AJ Lewis, onsite OSR, and Matt Bailey, AMEC. Rory Hunter, SWEPI LP contacted the Department at 0930 hours on 12/8/14 to report an environmental cleanup underway on the Watkins 820 pad. Swepi had performed a post-frac screening on the Watkins on 11/17/14. During this screening, soil conductivity readings greater than 1mS/cm were encountered in the vicinity of the tank battery. Field conductivity screenings were not completed until 12/3/14 when the tank battery had been removed, and additional areas of elevated conductivity above 1mS/cm were found. Violations were cited against the Watkins 820 21H well permt #2328155. Violations were immediately corrected.
2484927 Primary Facility 2016-05-17 Routine/Complete Inspection No Violations Noted The SWEPI, LP Watkins 820 site in Chatham Twp., Tioga Co. was inspected by the Department @ 1300 hours on 5/17/16. The weather was 59°, cloudy, winds WSW 8 mph. A valid site ID sign was observed at the entrace to the access road. The PPC Plan, onsite inspection log, well permits and a copy of the E&S plan were observed in the mailbox. The site was last inspected by company personnel on 5/11/2016 with “no change” noted in the comments.

During the onsite inspection, fluid was osberved in the the containment surrounding the 500-barrel- tanks. The fluid was screened for conductivity using an Oakton Multi-Parameter PCSTestr 35. The field conductivity was measured at 2.98 mS/cm. A puddle was observed on the pad surface adjacent to the tank containment. This puddle measured 7.34 mS/cm. An additional puddle (it was not clear in the field if the two were connected) was also screened and the field conductivity measured 6.77 mS/cm. A sampled of the puddle measuring 7.34 mS/cm was obtained and submitted to the lab in

2494018 Primary Facility 2016-05-17 Administrative/File Review No Violations Noted An administrative report was generated for the SWEPI LP – Watkins 820 site in Chatham Twp., Tioga Co. (ESX11-117-0019). Sample results collected 5/17/2016 indicate the presence of a pollution substance on the ground outside of containment. This constitutes a violation of 25 Pa. Code 78.45 (relating to Oil and Gas Wells) against the Watkins 820 23H well, permit #117-21676, based on the laboratory sample results. In accordance with S 78.54 the well operator shall control and dispose of fluids, residual waste and rill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, production fluids and drill cuttings in a manner that prevents pollution of the waters of this Commonwealth and in accordance with §§ 78.55-78.58 and 78.60-78.63 and with the statutes under which this chapter is promulgated.

No violations were cited against eh ESCGP or remaining well permit numbers.

2494148 Primary Facility 2016-06-08 Follow-up Inspection No Violations Noted The Department of Environmental Protection (DEP) conducted an onsite Follow-up inspection at the SWEPI LP – Watkins 820 well site in Chatham Twp., Tioga Co. (ESX11-117-0019) on 6/8/2016 @ 1010 hours. The weather was 50° and raining. The DEP was notified SWEPI would be conducting additional remediation efforts to remove soil with an elevated conductivity related to an unknown/unreported release on 6/8/2016.

Background: A violation of 25 PA. Code 78.54 was issued 5/17/2016 based on sample results, collected from a puddle outside containment by the DEP, showing elevated chlorides and conductivity . On 5/18/2016 SWEPI investigated the DEP’s findings. Mr. Bernethy stated he found areas of elevated conductivity and sent a vacuum truck to the site to clean up the puddles. SWEPI was investigating the secondary containment and the reason no spill was reported.

As of today’s inspection, SWEPI has removed material from the affected area. Approximately ½ a roll-off waste container of material was removed. Please pr
2523497 Primary Facility 2016-09-22 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the Wakins 820 site in Chatham Twp., Tioga Co. on 9/22/2016 @1245 hours. The valid site ID sign is located at the entrance to the access road. The site was last inspected by company personnel on 9/10/2016 with “erosion on lease road. Erosion on back side of pad by frac tanks and gravel.” recorded in the comments section.

No puddles were observed on the pad surface. Standing water was observed in the secondary containment surrounding the roll off tanks. The field conductivity was measured at 800µS/cm. Erosion was observed on the access road as noted in the E&S log. An area on the back side of the tank pad appears to have a mound of sawdust like material. Shredded ECB matting is visible on top of it. No vegetation was observed, but the pile does not appear to be eroding. All E&S controls appear to be functional. No violations are noted at this time. I departed the site @ 1330 hours. This inspection report references the following well permits – 117-

2557549 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the SWEPI LP Watkins 820 well site in Chatham Twp., Tioga Co. on 2/1/2017. The weather was partly sunny, 30°, fresh snow accumulation of ~3". No activity was observed onsite. No puddles observed on the pad surface. No vegetation was observed, but the site appears to be stable. Erosion and sediment controls were not observed due to snow cover, but no issues were detected. No violations were issued during this inspection. Please contact me with any questions.
2633257 Primary Facility 2017-09-06 Routine/Partial Inspection No Violations Noted EC readings with Oakton PCSTestr 35 (mS/cm): containment--0.27, pad--0.22.
2644738 Primary Facility 2017-09-28 Site Restoration No Violations Noted Electrical conductivity of liquid in wheelie trailer containment--2.1 mS/cm. I did not see any standing water on the pad surface.
2722366 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection inspected the Watkins 820 Well Site located in Chatham Twp, Tioga Co. on 4/25/2018 @ 1415 hours. The weather was 60 degrees and partly sunny . No activity was observed onsite.

There are five producing wells onsite. Production fluids are contained in Highland tanks. Water was observed in the secondary containment surrounding the Rolloff tank. The water exhibited conductivity within normal range. Two puddles on the pad service were also screened for conductivity and found to be within normal range.

No violations were noted. I departed the site at 1315 hours.

For data sources see[8]