37-117-21321

Well Details

Well ID: 37-117-21321
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Delmar Township
Operator Name: SWEPI LP
Well Pad ID: 148949
Farm/Lease Name: NESTOR E 551 3H
License Status:
Spud Date:
Permit Date: 2011-09-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.769233
Longitude: -77.298053

For data sources see[1][2][3]

Well History

Date Event
2011-09-28 New Permit Application
2011-10-10 Performed Spud Operation
2011-11-14 New Permit Application
2012-01-22 Drilling Completion
2012-05-25 Perforation
2013-12-05 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-06-17 2012-06-17 5,558 3,780,966

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FE-4 Univar Iron Control/Reducer Citric acid 77-92-9 50.00 0.00099000
Water 7732-18-5 50.00 0.00099000
Water Shell 100.00 95.84
I-22 Nalco Acid Corrosion Inhibitor Isopropanol 67-63-0 5.00 0.00003000
Aromatic aldehyde 30.00 0.00020000
Organic sulfur compounds 5.00 0.00003000
Formic acid 64-18-6 60.00 0.00039000
Quaternary ammonium compounds 5.00 0.00003000
Methanol 67-56-1 5.00 0.00003000
Oxyalkylated Fatty Acid 30.00 0.00020000
Benzyl chloride 100-44-7 1.00 0.00001000
Haloalkyl heteropolycycle salt 30.00 0.00020000
Hydrochloric Acid Reagent Chemical & Research Water 85.00 0.56
Hydrochloric acid 7647-01-0 15.00 0.09
Plexgel Breaker Chemplex Enzyme Breaker not classified as hazardous 100.00 0.00020000
PetroFlow Bio-Cide International Biocide Sodium chlorite 7758-19-2 8.35 0.00376000
Sodium carbonate 497-19-8 2.00 0.09
Water 7732-18-5 87.65 0.03
Sodium hydroxide 1310-73-2 1.00 0.04
Sodium chloride 7647-14-5 1.00 0.04
MSI-7 National Petrochemical Scale Inhibitor Hydorgen Chloride 0.00927000
FR-900 Nalco Scale Inhibitor not classified as hazardous 100.00 0.06
Plex 907 Chemplex Gelling Agent/Thickener vegetable gums 100.00 0.02
Sand Badger Mining Co. Proppant Quartz 14808-60-7 99.90 4.01

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 190,686.52 96 0.00 0 0.00 0
2013 SWEPI LP 446,326.35 330 0.00 0 0.00 0
2014 SWEPI LP 356,026.96 361 0.00 0 0.00 0
2015 SWEPI LP 281,468.82 361 0.00 0 0.00 0
2016 SWEPI LP 236,999.23 358 0.00 0 0.00 0
2017 SWEPI LP 202,975.30 352 0.00 0 0.00 0
2018 SWEPI LP 182,916.12 347 0.00 0 0.00 0
2019 SWEPI LP 159,750.88 324 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Produced Fluid 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Produced Fluid 34.20 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 8.56 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PAD987266749
2012 SWEPI LP Fracing Fluid Waste 8,008.87 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Drill Cuttings 209.84 Tons LANDFILL 8-4630-00010/00
2012 SWEPI LP Fracing Fluid Waste 8.56 Bbl CENT WASTE TRT FAC NPDES PAD987266749
2012 SWEPI LP Drill Cuttings 572.65 Tons LANDFILL 9312
2012 SWEPI LP Fracing Fluid Waste 674.29 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Fracing Fluid Waste 187.04 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 SWEPI LP Produced Fluid 39.18 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 SWEPI LP Produced Fluid 5,898.35 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Fracing Fluid Waste 14.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Produced Fluid 136.48 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Fracing Fluid Waste 20.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Produced Fluid 763.15 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Fracing Fluid Waste 66.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Produced Fluid 791.25 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 125.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 SWEPI LP Produced Fluid 51.59 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 43.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 80.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 18.81 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SWEPI LP Produced Fluid 419.40 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Produced Fluid 25.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 SWEPI LP Produced Fluid 10.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWEPI LP Produced Fluid 285.20 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWEPI LP Produced Fluid 23.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 SWEPI LP Produced Fluid 49.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 SWEPI LP Produced Fluid 176.00 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid 77.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 275.00 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Produced Fluid 50.11 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Produced Fluid 25.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 SWEPI LP Produced Fluid 9.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 SWEPI LP Produced Fluid 28.42 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Produced Fluid 125.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2112563 Primary Facility 2012-11-01 Routine/Complete Inspection No Violations Noted
2248802 Primary Facility 2014-02-25 Routine/Complete Inspection No Violations Noted
2306501 Primary Facility 2014-09-15 Routine/Complete Inspection No Violations Noted
2368873 Primary Facility 2015-04-27 Routine/Complete Inspection No Violations Noted
2497041 Primary Facility 2016-06-14 Routine/Complete Inspection No Violations Noted Routine inspection. Well site is permanently stabilized with exception of two slumped areas on the north fill slope of well pad-slumps are to be repaired and stabilized. Pad surface was dry and stable. 1H - 3H and 6H are in production. The 5H was plugged in March 2015. TLT
2590623 Primary Facility 2017-05-02 Routine/Partial Inspection No Violations Noted Puddle on pad gave 0.30 mS/cm EC reading w an Oakton PSCTestr 35.
2686559 Primary Facility 2018-01-25 Routine/Complete Inspection No Violations Noted I inspected the SWEPI LP Nestor 551 well pad located in Delmar Township, Tioga County on January 25, 2018. The weather was 20°, partly cloudy winds W at 7 mph. Some ice was observed on the pad surface.

For wells were observed drilled in production on the pad, the 1H, 2H, 3H, and 6H. Well tags were observed.

No violations or issues are noted at this time. I departed the site at 1430 hours.

2772848 Primary Facility 2018-08-27 Site Restoration No Violations Noted The DEP conducted a RESTORATION inspection of the SWEPI LP - Nestor 551 well site located in Delmar Twp, Tioga Co. on 8/27/2018 1330 hours. The weather was 78 degrees and sunny. Present for the inspection were myself and Korey Starkey, DEP Env. Trainee.

The access road, well pad, and surrounding controls were observed during the inspection. The pony pad has been removed and the area restored. The well pad has been reduced to ~275'x400'. The reclaimed areas appear stabilized by 70% perennial vegetative cover. No erosion or sedimentation was observed. No temporary BMPs were observed onsite.

Due to conditions observed onsite during the course of this inspection, this NOT is recommended for approval.

No violations are noted at this time. We departed the site at 1400 hours.

For data sources see[8]

References