X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21369

Well Details

Well ID: 37-117-21369
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Delmar Township
Operator Name: SWEPI LP
Well Pad ID: 147871
Farm/Lease Name: BUCKWALTER B 429 5H
License Status:
Spud Date:
Permit Date: 2011-11-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.668472
Longitude: -77.415717

For data sources see[1][2][3]

Well History

Date Event
2011-11-14 New Permit Application
2011-11-23 Performed Spud Operation
2012-02-21 Drilling Completion
2012-03-28 Perforation
2012-08-16 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-08-06 2012-08-06 5,848 2,939,580

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 MSI-7 National Petrochemical Scale Inhibitor Hydorgen Chloride 0.00899000
Plex 907 Chemplex Gelling Agent/Thickener vegetable gums 100.00 0.01
Hydrochloric Acid Reagent Chemical & Research Water 85.00 0.35
Hydrochloric acid 7647-01-0 15.00 0.06
Sand Badger Mining Co. Proppant Quartz 14808-60-7 99.90 5.61
PetroFlow Bio-Cide International Biocide Sodium chlorite 7758-19-2 8.35 0.00374000
Sodium carbonate 497-19-8 2.00 0.08
Sodium chloride 7647-14-5 1.00 0.04
Water 7732-18-5 87.65 0.03
Sodium hydroxide 1310-73-2 1.00 0.04
Water Shell 100.00 94.23
I-22 Nalco Acid Corrosion Inhibitor Oxyalkylated Fatty Acid 30.00 0.00012000
Methanol 67-56-1 5.00 0.00002000
Haloalkyl heteropolycycle salt 30.00 0.00012000
Isopropanol 67-63-0 5.00 0.00002000
Organic sulfur compounds 5.00 0.00002000
Aromatic aldehyde 30.00 0.00012000
Quaternary ammonium compounds 5.00 0.00002000
Benzyl chloride 100-44-7 1.00 0.00
Formic acid 64-18-6 60.00 0.00025000
Plexgel Breaker Chemplex Enzyme Breaker not classified as hazardous 100.00 0.00019000
FE-4 Univar Iron Control/Reducer Water 7732-18-5 50.00 0.00062000
Citric acid 77-92-9 50.00 0.00062000
FR-900 Nalco Scale Inhibitor not classified as hazardous 100.00 0.06

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 120,980.03 93 0.00 0 0.00 0
2013 SWEPI LP 379,250.47 358 0.00 0 0.00 0
2014 SWEPI LP 235,940.49 354 0.00 0 0.00 0
2015 SWEPI LP 185,747.80 358 0.00 0 0.00 0
2016 SWEPI LP 155,207.35 361 0.00 0 0.00 0
2017 SWEPI LP 146,966.47 265 0.00 0 0.00 0
2018 SWEPI LP 130,050.79 234 0.00 0 0.00 0
2019 SWEPI LP 105,985.89 188 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Produced Fluid 103.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Produced Fluid 6.08 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 10.61 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PAD987266749
2012 SWEPI LP Fracing Fluid Waste 11,637.38 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 10.61 Bbl CENT WASTE TRT FAC NPDES PAD987266749
2012 SWEPI LP Fracing Fluid Waste 691.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012 SWEPI LP Drill Cuttings 492.54 Tons LANDFILL 9312
2012 SWEPI LP Fracing Fluid Waste 5,968.41 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Fracing Fluid Waste 1,139.21 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Spent Lubricant 625.29 Bbl CENT WASTE TRT FAC NPDES PAD987266749
2012 SWEPI LP Spent Lubricant 625.29 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PAD987266749
2013 SWEPI LP Produced Fluid 68.41 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 SWEPI LP Produced Fluid 9,298.33 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Produced Fluid 1,194.18 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Produced Fluid 626.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Produced Fluid 66.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 SWEPI LP Fracing Fluid Waste 33.33 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 2,343.39 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 175.89 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SWEPI LP Produced Fluid 18.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 66.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC011
2015 SWEPI LP Produced Fluid 200.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 48.96 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SWEPI LP Produced Fluid 2,228.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Produced Fluid 196.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 SWEPI LP Produced Fluid 3,102.98 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWEPI LP Produced Fluid 99.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 SWEPI LP Produced Fluid 1,174.92 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid 469.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017 SWEPI LP Waste Water Treatment Sludge 2.01 Tons STORAGE PENDING DISPOSAL OR REUSE PA-0678
2018 SWEPI LP Produced Fluid 368.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 976.30 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Produced Fluid 307.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 SWEPI LP Produced Fluid 56.51 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 SWEPI LP Produced Fluid 66.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 SWEPI LP Produced Fluid 35.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 135.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Produced Fluid 366.99 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2019073 Primary Facility 2011-11-10 Routine/Complete Inspection No Violations Noted
2091828 Primary Facility 2012-08-15 Routine/Partial Inspection No Violations Noted
2098599 Primary Facility 2012-09-07 Incident- Response to Accident or Event No Violations Noted
2117271 Primary Facility 2012-11-19 Follow-up Inspection No Violations Noted
2324449 Primary Facility 2014-11-20 Routine/Partial Inspection No Violations Noted Routine partial inspection. No issues noted. TLT
2558795 Primary Facility 2017-02-02 Routine/Partial Inspection No Violations Noted Routine partial inspection. Site was idle and snow covered. The 2H, 5H and 6H wells are in production and the 1V well was placed on inactive status on 5/29/14. The site has not yet been restored. SWEPI submitted a 2-year restoration extension request on 12/10/14; the request was approved on 6/18/15. No violations were cited during this inspection. TLT
2619024 Primary Facility 2017-07-25 Site Restoration No Violations Noted On 7/25/17 at 0836 hrs I conducted an inspection at the Buckwalter 429 well site. No SWEPI representatives were present during the inspection. It was overcast and 67 degrees F.

I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log and the Well Site Restoration Report (WSRR).

The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed. Temporary E&S controls have been removed and the project is permanently stabilized as per 25 Pa Code Section 102.22(a)(2). The last routine E&S inspection was conducted on 7/23/17.

A 500 barrel (bbl) tank was staged in secondary containment. Standing water was observed in the secondary containment; the specific conductance field measurement was 485 micro Siemens/cm. Puddles on the pad were also tested; readings ranged between 232 - 258 micro Siemens/cm.

The WSRR was acknowledged on 7/25/17. No violations were cited during this inspection. I concluded the inspection at 0942 hrs. TLT

2632252 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 I reviewed and acknowledged the Buckwalter 429 Well Site Restoration Report (WSRR). The report was electronically submitted on 7/23/17. Site conditions were verified during an ESCGP Notice of Termination inspection conducted on 7/25/17; the associated inspection reports document that post-construction stormwater management practices are installed and the site is permanently stabilized.

No violations are cited in association with this administrative inspection. TLT

For data sources see[8]

References