X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21999

Well Details

Well ID: 37-117-21999
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Liberty Township
Operator Name: ROCKDALE MARCELLUS LLC
Well Pad ID: 146221
Farm/Lease Name: INGALLS 710 4H
License Status:
Spud Date: 2018-07-29
Permit Date: 2018-06-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.596985
Longitude: -77.018120

For data sources see[1][2][3]

Well History

Date Event
Deviated
2018-06-28 New Permit Application
2018-08-17 Performed Spud Operation
2018-10-10 Drilling Completion

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 ROCKDALE MARCELLUS LLC 4,018,013.30 214 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 73.33 Bbl REUSE (AT WELL PAD)
2018 ROCKDALE MARCELLUS LLC Drill Cuttings 1,652.49 Tons LANDFILL 301358
2018 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil 94.83 Tons LANDFILL 301358
2018 ROCKDALE MARCELLUS LLC Synthetic Liner Materials 26.95 Tons LANDFILL 301358
2018 ROCKDALE MARCELLUS LLC Produced Fluid 153.33 Bbl REUSE (AT WELL PAD)
2018 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil & Gas Related Spills 94.83 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil & Gas Related Spills 318.92 Tons LANDFILL 100955
2019 ROCKDALE MARCELLUS LLC Produced Fluid 102.29 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Synthetic Liner Materials 32.95 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil 267.79 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Produced Fluid 16,989.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 297.50 Bbl REUSE (AT WELL PAD)
2019 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil 318.92 Tons LANDFILL 100955
2019 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 197.50 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036
2019 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil & Gas Related Spills 267.79 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Produced Fluid 10,973.00 Bbl REUSE (AT WELL PAD)
2019 ROCKDALE MARCELLUS LLC Produced Fluid 16,902.50 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2760517 Primary Facility 2018-08-06 Routine/Complete Inspection No Violations Noted Weather was 78° and sunny at time of inspection. There were no Rockdale Marcellus representatives on location at time of inspection. Well is a spud conductor. Cellar is empty and recently cemented. Mouse hole was also in place. Both the conductor casing and mouse hole had steel plated welded over them at time of inspection. No violations were noted at time of inspection.
2765849 Primary Facility 2018-08-20 Routine/Complete Inspection No Violations Noted Weather was 78° and sunny at time of inspection. There were no Rockdale Marcellus representatives on location at time of inspection. Well had surface and intermediate casing drilled and cemented in place. Reviewed the job logs from the 2 cement jobs and no discrepancies were noted. Well was closed in with a nightcap until the rig moves back onto it to drill down to the kickoff point. No violations were noted at time of inspection.
2771524 Primary Facility 2018-09-06 Routine/Complete Inspection No Violations Noted Weather was 77° and sunny at time of inspection. There were no Rockdale Marcellus representatives on location at time of inspection. Surface and intermediate casing were drilled and cemented to surface. Well had a temporary wellhead installed until the completion rig moves onto location from the Wesneski Pad. Mouse hole had a steel plate welded over the top. No violations were noted at time of inspection.
2776854 Primary Facility 2018-09-19 Routine/Complete Inspection No Violations Noted Weather was 67° and cloudy at time of inspection. Met with Rockdale Marcellus representative Jim Tracey on location. Well was shit in with a nightcap installed. Rig was in the process of rigging up to complete the production casing string on the 2H. After the 2H is complete the rig will walk over this hole and complete it. No violations were noted at time of inspection.
2778813 Primary Facility 2018-09-24 Routine/Complete Inspection No Violations Noted Weather was 62° and partly cloudy at time of inspection. Met with Rockdale Marsellus representative Jim Tracy on location. Well was closed in with a night cap at tome of inspection. Well was covered with a rig mat. This well will be drilled to TD and cemented when the rig currently on site finished with the 2H. Conducted a walk around inspection of location. No violations were noted at time of inspection.
2784357 Primary Facility 2018-10-03 Routine/Complete Inspection No Violations Noted I met Danny Brooks, Rockdale company man, when I arrived. Drilling is completed, and the process of rigging down had just started. Drilling mud was present near the rig on the rig mats; cleaning the mats had not yet begun. Rolloff containers for cuttings in the backyard were on secondary containment, but these appeared to be undersized for the containers. I recommended to Danny that these containments be constructed larger in the future. A small area off of containment between the backyard and the pipe area had what appeared to be a 2' x 2' spot where a small amount of black discoloration, likely drill mud, was lightly smeared on top of the mud. I recommended to Danny that it be shoveled up immediately.
2840996 Primary Facility 2019-02-14 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess overall site conditions. Site was snow-covered at the time of inspection. Three well heads were present. None were staged for production and none had well tags. The Department recommends labeling the well heads with well tags. Three GPUs are present and are in good condition. Two steel double-walled produced water tanks are present and in good condition. There is some erosion present downhill of the outlet pipe for the infiltration basin.

No violations noted.

For data sources see[7]

References