37-129-28400

Well Details

Well ID: 37-129-28400
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Derry Township
Operator Name: XPR RESOURCES LLC
Well Pad ID: 149487
Farm/Lease Name: USCHAK 1 4H
License Status:
Spud Date:
Permit Date: 2010-07-23
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.340239
Longitude: -79.363464

For data sources see[1][2][3]

Well History

Date Event
2010-07-23 New Permit Application
2010-10-29 Performed Spud Operation
2010-12-18 Drilling Completion
2011-06-29 Perforation
2013-08-16 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-04 2011-07-04 8,185 2,291,779

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 11.29
Water Municipal Authority of Derry Borough Carrier/Base Fluid Water 100.00 88.56
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.10
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00006000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
BE-9M Halliburton Energy Services Biocide Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00161000
Methanol 67-56-1 30.00 0.00482000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00402000
GBW-30 Breaker Halliburton Energy Services Breaker Carbohydrates 95.00 0.00006000
Hemicellulase enzyme 9012-54-8 15.00 0.00001000
WG-36 Gelling Agent Halliburton Energy Services Gel Guar gum 9000-30-0 100.00 0.00471000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 XPR RESOURCES LLC 359,432.00 161 0.00 0 0.00 0
2012 XPR RESOURCES LLC 365,741.11 347 0.00 0 0.00 0
2013 XPR RESOURCES LLC 310,124.48 364 0.00 0 0.00 0
2014 XPR RESOURCES LLC 176,828.27 364 0.00 0 0.00 0
2015 XPR RESOURCES LLC 154,529.59 365 0.00 0 0.00 0
2016 XPR RESOURCES LLC 119,102.74 366 0.00 0 0.00 0
2017 XPR RESOURCES LLC 101,012.38 360 0.00 0 0.00 0
2018 XPR RESOURCES LLC 82,376.00 364 0.00 0 0.00 0
2019 XPR RESOURCES LLC 83,032.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 XPR RESOURCES LLC Produced Fluid 939.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2013 XPR RESOURCES LLC Produced Fluid 441.83 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2013 XPR RESOURCES LLC Produced Fluid 506.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 XPR RESOURCES LLC Produced Fluid 623.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 XPR RESOURCES LLC Produced Fluid 192.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 165.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 XPR RESOURCES LLC Fracturing Fluid Waste 14.09 Tons LANDFILL 100434
2016 XPR RESOURCES LLC Waste Water Treatment Sludge 54.70 Tons LANDFILL 100434
2016 XPR RESOURCES LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2017 XPR RESOURCES LLC Produced Fluid 200.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 XPR RESOURCES LLC Waste comment only 0.00
2018 XPR RESOURCES LLC Produced Fluid 123.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 XPR RESOURCES LLC Produced Fluid 80.00 Bbl REUSE (AT WELL PAD)
2019 XPR RESOURCES LLC Produced Fluid 137.50 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1930274 Primary Facility 2010-11-23 Drilling/Alteration No Violations Noted PATTERSON RIG 480 DRILLING ON WILLIAMS PAD. E&S, PITS, AND HOUSE KEEPING GOOD. LINER UNDER RIG, FUEL AND MUD TANKS. DEPTH 1895'
1939454 Primary Facility 2010-12-07 Drilling/Alteration No Violations Noted HORIZONAL MARCELLUS
1939510 Primary Facility 2010-12-14 Drilling/Alteration No Violations Noted drilling @ 9040ft/E&S ok/ID&pits ok
1940935 Primary Facility 2010-12-30 Drilling/Alteration No Violations Noted HORIZONAL MARCELLUS
1949563 Primary Facility 2011-02-02 Routine/Complete Inspection No Violations Noted Inspection was conducted during routine site visit.
1956042 Primary Facility 2011-03-07 Routine/Complete Inspection No Violations Noted Wellsite bein prepared for Frac Job
1970655 Primary Facility 2011-04-19 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS
2020725 Primary Facility 2011-11-18 Routine/Complete Inspection No Violations Noted HORIZONTAL MARCELLUS
2058684 Primary Facility 2012-04-03 Routine/Complete Inspection No Violations Noted NOT RECLAIMED. HAS 4 PRODUCED FLUIDS TANKS, AND 5 GPU'S ON PAD.
2120206 Primary Facility 2012-12-04 Routine/Complete Inspection No Violations Noted At the time of inspection the well was drilled and equipped for production. The associated well apparatus, brine tank, and production heater appear to be in sound condition. The E&S plan was on site and appeared to implemented as outlined in the plan. No observation of accelerated erosion and sedimentation in relation to the well pad and access road.
2131193 Primary Facility 2013-01-11 Routine/Complete Inspection No Violations Noted HORIZONAL MARCELLUS
2147106 Primary Facility 2013-03-05 Site Restoration Pending Inspection in response to a Notice of Termination in regards to ESX10-129-0015. During the inspection the Department observed several pyritic seeps below the well pad within the limit of disturbance. The Department suggest the Operator investigate the cause of the impacted and submit a plan of action that will address the mitigation and monitoring of the affected area.
2179709 Primary Facility 2013-06-25 Routine/Complete Inspection Pending At the time of inspection the well was drilled and equipped for production. The associated well apparatus, brine tank, and production heater appear to be in sound condition. The E&S plan was on site and appeared to implemented as outlined in the plan. The Department notes the Operator has started the seep remediation located on the fill side of the well site.
2182031 Primary Facility 2013-07-09 Follow-up Inspection Pending At the time of inspection the well was drilled and equipped for production. The associated well apparatus, brine tank, and production heater appear to be in sound condition. The E&S plan was on site and appeared to implemented as outlined in the plan. The Department notes the Operator has finished the installation of the infiltration ditch located on the fill side of the well site, additional the Operator has started to install additional infiltration ditches in the fill side area of the pad directly in front of the well heads. At the time of inspection he area located on the cut side of the well pad has not been regraded.
2274467 Primary Facility 2014-05-21 Routine/Complete Inspection No Violations Noted 5/21/2014 RECLAIMED, VEGETATED, HAS PRODUCED FLUIDS TANKS, AND 5 GPU'S ON PAD.
2326017 Primary Facility 2014-12-03 Routine/Complete Inspection No Violations Noted 12/3/2014 RECLAIMED, VEGETATED, HAS PRODUCED FLUIDS TANKS, AND 5 GPU'S ON PAD.
2374575 Primary Facility 2015-05-27 Follow-up Inspection Pending At the time of inspection the pyritic seep, first observed in March of 2013, still exists. The pyritic seeps appear to be preventing vegetative growth at the site. The vegetative growth is not uniform and does not meet restoration requirements. As previously discussed as a remedy the Department allowed for the installation of infiltration ditches and has given the site a full growing season. The addition of the ditches and a full growing season has not resulted in the elimination of the pyritic seep. The Department suggests the Operator continue to monitor the site and begin to develop a strategy to eliminate or treat the seep. The Department would also like to request a meeting to discuss this seep and the strategies implemented to resolve this issue.
2377813 Primary Facility 2015-06-09 Routine/Complete Inspection No Violations Noted 6/9/2014 RECLAIMED, VEGETATED, HAS PRODUCED FLUIDS TANKS, AND GPU'S ON PAD.
2444218 Primary Facility 2016-01-25 Routine/Complete Inspection No Violations Noted Access road gated, locked and shared with ag field. At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Four brine tanks located on site within secondary containment and appear to be structurally sound. Site permanently stabilized, ground snow covered, no signs of E& S issues in relation to site and/or access road.
2474221 Primary Facility 2016-04-12 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set-tank battery and dike look ok.
2556092 Primary Facility 2017-01-27 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2556713 Primary Facility 2017-01-27 Routine/Complete Inspection No Violations Noted At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Four brine tanks located on site within secondary containment and appear to be structurally sound. Site permanently stabilized, no E& S issues in relation to site and/or access road.
2621772 Primary Facility 2017-08-02 Routine/Complete Inspection No Violations Noted Well tagged-on. Well head casing-production set equipment-tank battery-dike containment look ok.
2681107 Primary Facility 2018-01-10 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Brine tank within secondary containment and appears to be structurally sound. Department records does not indicate well site restoration submitted.

Ongoing pyritic seeps concerns are being addressed under ESCGP ESX10-129-0015, Site ID 735951, Inspection ID 2681073.