{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.337361,"lon":-77.158103,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Lycoming Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 149082 | |
Farm/Lease Name: POOR SHOT EAST UNIT 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-06-09 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.337361 | |
Longitude: -77.158103 |
Date | Event |
---|---|
2010-06-09 | New Permit Application |
2010-09-03 | Performed Spud Operation |
2010-10-21 | Drilling Completion |
2011-04-28 | DEVIATED |
2011-09-20 | Perforation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-09-17 | 2011-09-17 | 7,316 | 3,273,711 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand (Proppant) | Calfrac Well Services | Propping Agent | Quartz | 14808-60-7 | 99.90 | 12.73 | |
DAP-901 | Calfrac Well Services | Scale Inhibitor | Phosphoric acid ammonium salt | 5.00 | 0.00093000 | |||
Amine salt | 5.00 | 0.00093000 | ||||||
Methanol | 67-56-1 | 30.00 | 0.00557000 | |||||
Organic phosphonate | 30.00 | 0.00557000 | ||||||
Ammonium chloride | 12125-02-9 | 10.00 | 0.00186000 | |||||
Oxyalkylated polyamine | 5.00 | 0.00093000 | ||||||
3 HCl Acid | Calfrac Well Services | Perforation Breakdown | Hydrochloric acid | 7647-01-0 | 100.00 | 0.72 | ||
DWP-972 | Calfrac Well Services | Oxygen Scavenger | Sodium thiosulfate | 7772-98-7 | 31.00 | 0.01 | ||
Water | Base Fluid | Water | 100.00 | 86.35 | ||||
DAP-923 | Calfrac Well Services | Corrosion Inhibitor | Fatty acids, tall-oil | 61790-12-3 | 30.00 | 0.00038000 | ||
Methanol | 67-56-1 | 60.00 | 0.00076000 | |||||
Ethoxylated C14-15 alcohols | 68951-67-7 | 30.00 | 0.00038000 | |||||
Thiourea polymer | 68527-49-1 | 30.00 | 0.00038000 | |||||
Propargyl alcohol | 107-19-7 | 10.00 | 0.00013000 | |||||
Alkenes, C>10 .alpha.- | 64743-02-8 | 5.00 | 0.00006000 | |||||
DWP-612 | Calfrac Well Services | Friction Reducer | No Hazardous Materials | 100.00 | 0.08 | |||
DWP-944 | Calfrac Well Services | Biocide | Polyethylene glycol | 25322-68-3 | 70.00 | 0.02 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 40.00 | 0.01 | |||||
DAP-103 | Calfrac Well Services | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00318000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA LLC | 53,492.00 | 31 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 687,016.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 417,798.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 324,640.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 254,419.00 | 342 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 192,334.00 | 240 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 192,549.00 | 336 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 167,140.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 152,185.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 114.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 95.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 4,584.51 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EXCO RESOURCES PA LLC | Drilling Fluid Waste | 243.81 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011 | EXCO RESOURCES PA LLC | Fracing Fluid Waste | 5,590.95 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EXCO RESOURCES PA LLC | Fracing Fluid Waste | 119.05 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 623.71 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 119.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 109.52 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 7,215.43 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | EXCO RESOURCES PA LLC | Fracturing Fluid Waste | 26.68 Tons | LANDFILL | 301358 |
2012 | EXCO RESOURCES PA LLC | Fracturing Fluid Waste | 4.38 Tons | LANDFILL | 100585 |
2012 | EXCO RESOURCES PA LLC | Drill Cuttings | 1.55 Tons | LANDFILL | 301358 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 164.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 219.02 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC024 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 347.79 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 1,659.95 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 383.30 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 660.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 220.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 109.50 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 109.60 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC024 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 323.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 755.20 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2016 | EXCO RESOURCES PA LLC | Produced Fluid | 585.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 420.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 305.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 105.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 356.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 45.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1919108 | Primary Facility | 2010-10-07 | Drilling/Alteration | No Violations Noted | ran 13 3/8 to 401 ft 14 bbl ret on cement job**** ran 1400 ft 9 5/8 casing 20 bbl ret cement to surface |
2019107 | Primary Facility | 2011-11-14 | Routine/Complete Inspection | No Violations Noted | |
2043860 | Primary Facility | 2012-02-17 | Routine/Complete Inspection | No Violations Noted | |
2082843 | Primary Facility | 2012-07-12 | Routine/Complete Inspection | No Violations Noted | |
2125993 | Primary Facility | 2012-12-14 | Routine/Complete Inspection | No Violations Noted | |
2484060 | Primary Facility | 2016-05-11 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 5/11/2016.
I entered the location at 15:17 and began the inspection. The Poor Shot Transfer pad off Stony Gap Road, the Poor Shot Unit 2H well pad, The Poor Shot Unit 3H well pad, and the Poor Shot 1H well pad were all constructed under one ESCGP (ESX10-081-0023). The Poor Shot Freshwater Impoundment was never constructed. A : At the Poor Shot transfer pad, the pad location remains at its originally constructed size. The Site Restoration Plan calls for Sediment Ditch #1, Sediment Trap #1, and Sediment Ditch #2 to be removed. In addition, erosion is noted on the north side of the pad near the western edge of Diversion Ditch #1. I recommend correcting this erosion as soon as possible. This part of the ESCGP has not been restored as per the ESCGP. B : At the Poor Shot Unit 2H well pad, the Poor Shot East Unit 1H (081-20092) and Poor Shot E Unit 2H (081-20278) wells were both in production. The Site Restoration Plan calls for one 60’ Infiltration Berm to be constructed. The Infiltr |
2513021 | Primary Facility | 2016-08-15 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unconventional well in production. No violations noted at this time. |
2841892 | Primary Facility | 2019-02-11 | Routine/Complete Inspection | No Violations Noted | On February 11, 2019 Department representative Jared Jacobini conducted a routine site inspection at EXCO Poor Shot Unit 3H OG Well. The site sign, drilling permits, weekly E&S reports, and emergency response plan were onsite for review. A total of two producing wells located on this well pad. All wells are tagged with API/well permit numbers. The cellars are filled with gravel. There is one GPU and two steel vertical production fluids tanks onsite. GPU was not stationed in secondary containment. Production fluid tanks were stationed in secondary containment but the liner is damaged. PSCM's have not been installed. No erosion issues were observed. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.
Site has not been restored in accordance with PCSM & Restoration ESG29-081-117009. The Department recommends addressing the following: 1. Production water tank secondary containment liner tears (Photo #1, 2). 2. Placing pump outlet inside the containment (Photo |
2849635 | Primary Facility | 2019-03-07 | Routine/Complete Inspection | No Violations Noted | The weather was cloudy with a temperature of 12 degrees Fahrenheit. Two wells staged for production. Two GPUs in use with no leaks detected. PCSMs could not be determined due to snow cover. |