X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20456

Well Details

Well ID: 37-081-20456
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 147842
Farm/Lease Name: BOWER UNIT 4H
License Status:
Spud Date:
Permit Date: 2010-12-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.281275
Longitude: -76.631356

For data sources see[1][2][3]

Well History

Date Event
2010-12-28 New Permit Application
2011-04-30 Performed Spud Operation
2011-06-07 New Permit Application
2011-07-18 Drilling Completion
2011-10-12 Perforation
2012-07-19 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-10-12 2011-10-12 7,365 7,062,273

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DWP-612 Calfrac Well Services Friction Reducer No Hazardous Materials 100.00 0.07
DWP-972 Calfrac Well Services Oxygen Scavenger Sodium thiosulfate 7772-98-7 31.00 0.00815000
Sand (Proppant) Calfrac Well Services Propping Agent Quartz 14808-60-7 99.90 14.25
Water Base Fluid Water 100.00 85.09
DWP-944 Calfrac Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Polyethylene glycol 25322-68-3 70.00 0.02
DAP-923 Calfrac Well Services Corrosion Inhibitor Fatty acids, tall-oil 61790-12-3 30.00 0.00025000
Propargyl alcohol 107-19-7 10.00 0.00008000
Methanol 67-56-1 60.00 0.00050000
Alkenes, C>10 .alpha.- 64743-02-8 5.00 0.00004000
Thiourea polymer 68527-49-1 30.00 0.00025000
Ethoxylated C14-15 alcohols 68951-67-7 30.00 0.00025000
3 HCl Acid Calfrac Well Services Perforation Breakdown Hydrochloric acid 7647-01-0 100.00 0.47
DAP-103 Calfrac Well Services Iron Control Citric acid 77-92-9 60.00 0.00210000
DAP-901 Calfrac Well Services Scale Inhibitor Phosphoric acid ammonium salt 5.00 0.00109000
Methanol 67-56-1 30.00 0.00656000
Ammonium chloride 12125-02-9 10.00 0.00219000
Organic phosphonate 30.00 0.00656000
Oxyalkylated polyamine 5.00 0.00109000
Amine salt 5.00 0.00109000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 440,367.00 320 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 461,475.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 413,663.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 334,590.00 306 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 310,760.00 279 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 348,870.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 329,527.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 303,108.00 358 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 455.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 EXCO RESOURCES PA LLC Fracing Fluid Waste 6,023.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Produced Fluid 10,095.93 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Produced Fluid 109.52 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Fracturing Fluid Waste 111.64 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Drill Cuttings 5.81 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Produced Fluid 59.50 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 438.08 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2013 EXCO RESOURCES PA LLC Produced Fluid 109.52 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 219.02 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC024
2013 EXCO RESOURCES PA LLC Produced Fluid 1,161.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid 762.36 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 3,067.04 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 1,540.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 823.20 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 329.50 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014 EXCO RESOURCES PA LLC Produced Fluid 507.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Produced Fluid 1,475.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2015 EXCO RESOURCES PA LLC Produced Fluid 2,950.10 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 317.70 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EXCO RESOURCES PA LLC Produced Fluid 3,415.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 3,343.10 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 3,101.20 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 245.80 Bbl REUSE (AT WELL PAD)
2018 EXCO RESOURCES PA LLC Produced Fluid 412.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EXCO RESOURCES PA LLC Produced Fluid 2,343.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 841.50 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1985128 Primary Facility 2011-06-27 Routine/Partial Inspection Violation(s) Noted
1997753 Primary Facility 2011-08-22 Drilling/Alteration Violation(s) Noted
2043852 Primary Facility 2012-02-17 Routine/Complete Inspection No Violations Noted
2044688 Primary Facility 2012-02-21 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
2055064 Primary Facility 2012-03-29 Follow-up Inspection Outstanding Violations - No Viols Req'd
2055074 Primary Facility 2012-03-26 Follow-up Inspection Outstanding Violations - No Viols Req'd
2437803 Primary Facility 2015-12-30 Routine/Complete Inspection No Violations Noted Arrived @ 13:15. Weather: foggy, cloudy, some fine drizzle5 wells, formerly in production, were shut-in. All well cellars were filled with gravel. There were two open annular vents at each well. The 13-3/8” x 9-5/8” was vented with a 1” pipe. The 9-5/8” x 5-1/2” annulus was vented with a 2” pipe. The annuli were monitored with an Altair 5X gas meter calibrated on 12/28/15.
2437887 Primary Facility 2015-12-30 Routine/Complete Inspection No Violations Noted Arrived @ 13:15. Weather: foggy, cloudy, some fine drizzle5 wells, formerly in production, were shut-in. All well cellars were filled with gravel. There were two open annular vents at each well. The 13-3/8” x 9-5/8” was vented with a 1” pipe. The 9-5/8” x 5-1/2” annulus was vented with a 2” pipe. The annuli were monitored with an Altair 5X gas meter calibrated on 12/28/15.
2543940 Primary Facility 2016-12-08 Routine/Complete Inspection No Violations Noted Routine Inspection; 12/8/2016. I entered the location at 10:06 and began the inspection. At the time of the inspection, the Bower Unit 1H (081-20149, 2H (081-20361), 3H (081- 20362), 4H (081-20456), and 6H (081-20356) wells were in production. The well pad area was well vegetated and can be considered permanently stabilized. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the pad was reclaimed and the Notice of Termination was to be submitted in September of 2015. The well pad remains at its original size and the site currently does not conform to the permitted restoration plan. The original E&S permit has been expired since 10/16/2014.

The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:

1. All permanent post construction stormwater control features as identified in the Post Construction Stormwater Management/Site Restoratio
2694631 Primary Facility 2018-02-14 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. Well had a digital pressure gauge attached above the swab valve for the tubing and attached to the 5 1/2 casing valve. Pressure on the tubing was 258 psi and the 5 1/2 casing pressure was 393 psi at time of inspection. There were three annulus vents plumbed to surface. The 5 1/2 x 9 5/8 annulus vent was plumbed across location to the produced water tanks. The 9 5/8 x 13 3/8 and 13 3/8 x 20 annulus vents were open and 0% combustible gas was detected at time of inspection. No violations were noted at time of inspection.
2833657 Primary Facility 2019-01-28 Routine/Complete Inspection No Violations Noted On January 28, 2019, Department representative Brad Kline conducted a routine site inspection at EXCO Resources, LLC. Bower Pad 1H. Site inspection log was onsite for review. No E&S issues were observed during the time of inspection. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.

There are a total of 5 producing wells located on this well pad. All wells are tagged with API/well permit numbers. Well cellars are filled in with gravel. There are 5 GPU’s and 4 steel vertical production fluids tanks onsite. Production fluid tanks were stationed in secondary containment.

No violations noted. The Department recommends submitting a Notice of Termination and a Well Site Restoration Report when the criteria is met.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1985128 614698 06/27/2011 2011-06-27 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative Larry Sanders of EXCO sent in a picture of the site ID sign with the company address posted.
1997753 618482 08/22/2011 2011-08-22 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative bubbling 13 3/8 x 9 5/8 casing annulus

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
614698
618482

For data sources see[8]

References