37-015-20105

Well Details

Well ID: 37-015-20105
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Herrick Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 153757
Farm/Lease Name: GREENZWEIG 1H
License Status:
Spud Date:
Permit Date: 2008-09-09
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.786636
Longitude: -76.230888

For data sources see[1][2][3]

Well History

Date Event
2008-09-09 New Permit Application
2008-09-22 Performed Spud Operation
2008-11-12 Perforation
2008-12-02 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2010 SOUTHWESTERN ENERGY PROD CO 395,483.00 174 0.00 0 0.00 0
2011 SOUTHWESTERN ENERGY PROD CO 603,474.00 303 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 451,095.00 365 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 337,307.00 354 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 303,356.00 365 0.00 0 0.00 0
2015 SWN PROD CO LLC 212,510.00 364 0.00 0 0.00 0
2016 SWN PROD CO LLC 247,007.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 211,575.00 352 0.00 0 0.00 0
2018 SWN PROD CO LLC 189,462.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 165,933.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 2.95 Tons LANDFILL 101247
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 397.29 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 825.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid 467.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid 1,213.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC 51.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 129.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC 195.82 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 195.82 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Produced Fluid 90.86 Bbl SURFACE IMPOUNDMENT 826342
2017 SWN PROD CO LLC Produced Fluid 510.43 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Other Oil & Gas Wastes 7.14 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 224.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC 349.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC 0.66 Tons LANDFILL 100933
2017 SWN PROD CO LLC Other Oil & Gas Wastes 26.28 Bbl SURFACE IMPOUNDMENT 826342
2017 SWN PROD CO LLC Synthetic Liner Materials 0.66 Tons LANDFILL 100933
2017 SWN PROD CO LLC 26.28 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 31.68 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 304.99 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 115.86 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 174.86 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 54.16 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 16.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 163.56 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 9.36 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 41.42 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 33.42 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 132.01 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1740741 Primary Facility 2008-10-07 Routine/Complete Inspection No Violations Noted
1981508 Primary Facility 2011-06-13 Routine/Complete Inspection No Violations Noted Refer to the Greenzweig #1 for inspection report comments.
2006341 Primary Facility 2011-09-13 Routine/Complete Inspection No Violations Noted The intent of the inspections was to assure the flowback water did not exceed the 2¿ freeboard requirement as per 25 PA code 78.56 (a) (2) and the liner did not experience compromised integrity as per 25 PA code 78.56 (a) (4), due to recent rainfall events from tropical storms. During the inspection, the freeboard level was observed to be right at the 2¿ freeboard level. Compromised integrity of the impoundment liners was not noted. Jason Petlock of Southwestern informed us that prior to 9/14 the freeboard level was slightly exceeded in the 40,000 barrel capacity flowback water only impoundment; Permit number ESX10-015-0078. Southwestern transferred water from this impoundment to vertical holding tanks in the tank farm area to keep the surface water elevation as low as possible. Some staining and water marks were observed form the surface of the water to the top portion of the liner. The 200,000 barrel capacity flowback/fresh water blended impoundment, Permit Number ESX10-015-0072, did not experience freeboard exceeding and staining.
2027575 Primary Facility 2011-12-19 Administrative/File Review Violation(s) Noted
2073306 Primary Facility 2012-06-04 Administrative/File Review No Violations Noted Violations and specifcs associated with this inspection have been attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
2074338 Primary Facility 2012-06-08 Incident- Response to Accident or Event Adverse Events or Actions Reported Inspection part of a contunuing investigation into the identified chloride elevated seeps located on the fill slope of the tank farm pad. Sample # 0257070 was collected from the discharge of the small laggon underdrain discharge. Primary focus of investigation is to determine the status of the integrity of the small lagoon liner. Large lagoon liner integrity is not in question at this time.
2074903 Primary Facility 2012-06-11 Administrative/File Review No Violations Noted Violations and specfics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
2075047 Primary Facility 2012-05-15 Incident- Response to Accident or Event No Violations Noted Please refer to the Greenzweig Unit #1 inspection report regarding details of the investigation. Permit number is 015-20081.
2098044 Primary Facility 2012-09-05 Administrative/File Review No Violations Noted Violations and specifics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
2099253 Primary Facility 2012-09-10 Routine/Complete Inspection Outstanding Violations - No Viols Req'd Inspection conducted on 9/10/12 with Rich Gulyas. 2 new monitoring wells have been installed. One is located below the small impoundment, and the other is located below well pad and between the large and small impoundment. Drill cuttings and casing sealant debris is located around both new monitoring wells. Rich said he would get rid of this debris ASAP. The sump pump located in the sump cellar which was installed in the rocked swale right above the small impoundment is not functional. Rich not sure why. Please send an email explaining your intentions for this sump pump.
2163306 Primary Facility 2013-04-24 Routine/Complete Inspection No Violations Noted
2256686 Primary Facility 2014-03-20 Routine/Partial Inspection No Violations Noted
2603354 Primary Facility 2017-06-06 Routine/Complete Inspection No Violations Noted On June 6, 2017, at 1200 hrs., the Department conducted a routine inspection at the SWN Production Company LLC, GU-C-Pad in Herrick Township, Bradford County. Andrew Hobbins, Water Quality Specialist, represented the Department. A SWN representative was on site performing maintenance work on the adjacent waste impoundments.

The site sign, E & S plan and the weekly inspection logs were on site and available for review. The site was well vegetated and no erosion issues were observed. PCSM has not been addressed at the site, but the site has been re-permitted and upgraded to an ESCGP-2. PCSM installation is scheduled for the month of June.

Seven wells were in production phase during the inspection. All of the wells were labeled and no bubbling was observed in the well cellars. Two production tanks and seven GPUs were also observed on site. The production tanks were observed in secondary containment. Puddles on the pad surface were low in specific conductivity. A small area of stained gravel was

2818307 Primary Facility 2018-12-18 Site Restoration No Violations Noted The DEP conducted a RESTORATION inspection of SWN's Greenzweig (C Pad) in Herrick Twp, Bradford County on 12/18/2018 at 1155 hours. The inspection was conducted in response to a Well Site Restoration Report received by the DEP.

The site has recently been disturbed to install PCSM BMPs per restoration plans. The areas that were disturbed now have straw/hay layered to assist in vegetation growth in the Spring. The areas are poorly vegetated now and are not stabilized. Silt sock was observed beneath the newly constructed Bioretention basin. This site does not meet the requirements for restoration under a well site restoration report. The site is not stabilized with 70% vegetative cover and temporary E&S BMPs are still installed. It is understood that Southwestern has a Consent & Order agreement with the department to install these newly permitted PCSM BMPs. Upon further discussion, the sites already inspected will have to be returned.

This Well Site Restoration Report is considered returned at this time.

No

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2027575 627155 12/19/2011 2011-12-19 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety NOV response rec'vd 1/6/12, MBC data clean-up 4/30/15.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
627155 279143 NOV - Notice of Violation Administrative Close Out 2012-01-06