Well ID: 37-015-22120 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.987283,"lon":-76.313036,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Windham Township | |
Operator Name: REPSOL OIL & GAS USA LLC | |
Well Pad ID: 149211 | |
Farm/Lease Name: ROGERS 05 235 03 H 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-02-16 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.987283 | |
Longitude: -76.313036 |
Date | Event |
---|---|
2012-02-16 | New Permit Application |
2012-07-11 | Performed Spud Operation |
2013-03-13 | Perforation |
2014-02-14 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-03-12 | 2013-03-12 | 4,850 | 5,731,488 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Customer | Water | Water | 7732-18-5 | 100.0 | 85.36187 | |
FEAC-20 | Trican | Iron Control | Citric acid | 77-92-9 | 30.0 | 0.00025 | ||
Acetic acid | 64-19-7 | 45.0 | 0.00038 | |||||
BioClear 5000 | Trican | Biocide | Polyethylene glycol | 25322-68-3 | 70.0 | 0.01874 | ||
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 10.0 | 0.00268 | |||||
HCl 7.5 | Trican | Acid | Hydrochloric acid | 7647-01-0 | 7.5 | 0.00463 | ||
WG-111L | Trican | Gelling Agent | polysaccharide blend | 9000-30-0 | 60.0 | 0.00306 | ||
light hydrotreated petroleum distillate | 64742-47-8 | 60.0 | 0.00306 | |||||
Frac Sand - regular | Trican | Proppant | Crystalline silica | 14808-60-7 | 100.0 | 14.39482 | ||
AI-7NR | Trican | Acid Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1.0 | None | ||
HCl 3.5 | Trican | Acid | Hydrochloric acid | 7647-01-0 | 3.5 | 0.00209 | ||
GBO-1 | Trican | Breaker | Sodium perBorate tetrahydrate | 10486-00-7 | 100.0 | 0.00025 | ||
LSI-21 | Trican | Scale Inhibitor | Sodium Salt of Phosphate Ester | 68131-72-6 | 15.0 | 0.0038 | ||
Acrylic Polymer | 28205-96-1 | 15.0 | 0.0038 | |||||
FR-8 | Trican | Friction Reducer | Petroleum distillates, dewaxed heavy paraffinic | 64742-65-0 | 8.0 | 0.00506 | ||
Petroleum distillates, hydrotreated heavy paraffinic | 64742-54-7 | 8.0 | 0.00506 | |||||
Petroleum distillate hydrotreated light | 64742-47-8 | 28.0 | 0.01772 | |||||
Ammonium chloride | 12125-02-9 | 1.5 | 0.00095 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | REPSOL OIL & GAS USA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | REPSOL OIL & GAS USA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | REPSOL OIL & GAS USA LLC | 974,777.10 | 316 | 0.00 | 0 | 0.00 | 0 |
2015 | REPSOL OIL & GAS USA LLC | 742,488.60 | 362 | 0.00 | 0 | 0.00 | 0 |
2016 | REPSOL OIL & GAS USA LLC | 606,064.80 | 364 | 0.00 | 0 | 0.00 | 0 |
2017 | REPSOL OIL & GAS USA LLC | 483,371.70 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | REPSOL OIL & GAS USA LLC | 399,791.30 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | REPSOL OIL & GAS USA LLC | 347,266.30 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | REPSOL OIL & GAS USA LLC | Drill Cuttings | 1,272.62 Tons | LANDFILL | 8-0728-0004/013 |
2012 | REPSOL OIL & GAS USA LLC | Drill Cuttings | 75.79 Tons | LANDFILL | NY31346244 |
2013 | REPSOL OIL & GAS USA LLC | Fracturing Fluid Waste | 22.09 Tons | LANDFILL | 100361 |
2014 | REPSOL OIL & GAS USA LLC | Fracing Fluid Waste | 1,355.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | REPSOL OIL & GAS USA LLC | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | REPSOL OIL & GAS USA LLC | Produced Fluid | 6,371.93 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | REPSOL OIL & GAS USA LLC | Produced Fluid | 715.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | REPSOL OIL & GAS USA LLC | Produced Fluid | 820.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | REPSOL OIL & GAS USA LLC | Produced Fluid | 205.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | REPSOL OIL & GAS USA LLC | Produced Fluid | 865.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | REPSOL OIL & GAS USA LLC | Produced Fluid | 410.00 Bbl | REUSE (AT WELL PAD) | |
2018 | REPSOL OIL & GAS USA LLC | Produced Fluid | 410.00 Bbl | REUSE (AT WELL PAD) | |
2019 | REPSOL OIL & GAS USA LLC | Produced Fluid | 410.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2117649 | Primary Facility | 2012-08-15 | Routine/Complete Inspection | No Violations Noted | Well drilled, mouse hole covered with 2X4. Well shut-in. No gauges on annuli. Contact rep concerning mousehole. |
2156126 | Primary Facility | 2013-04-11 | Routine/Complete Inspection | No Violations Noted | |
2249185 | Primary Facility | 2014-02-25 | Routine/Complete Inspection | No Violations Noted | |
2351150 | Primary Facility | 2014-11-10 | Routine/Complete Inspection | No Violations Noted | No gauges on annuli. Well in production. Cellar filled with water, no visible bubbling. |
2352393 | Primary Facility | 2014-11-10 | Routine/Complete Inspection | No Violations Noted | 3 wells on pad. Unable to determine if the conductor was set on wells 1H and 2H as cellar was covered with cement and manhole. Rogers 3 well was in production, however no gauges on any of the annuli. Cellar filled with water, with no visible bubbling. |
2465417 | Primary Facility | 2016-03-16 | Routine/Complete Inspection | No Violations Noted | |
2627754 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | On August 16, 2017, the Department conducted a routine inspection at the Repsol Oil and Gas USA LLC, Rogers H (05-235) well site in Windham Township, Bradford County. Andrew Hobbins, Water Quality Specialist represented the Department. Nobody was present for Repsol.
The site sign, E & S plan and weekly inspection logs were on site and available for review. No erosion or sedimentation issues were observed. PCSM has been addressed at the site. One well was in production during the inspection. The well was labeled and no bubbling was observed in the well cellar. On GPU and One production tank were in secondary containment. Liquid within the containment was low in specific conductivity. Puddles on the pad were also low in specific conductivity. No staining was observed. Two infiltration basins were installed at the site to address PCSM. The well pad has not been reduced in size. A two year restoration extension was approved by the Department on 12/2/2016. No violations were observed during the |
2810389 | Primary Facility | 2018-12-04 | Site Restoration | No Violations Noted | NOT approval.
Electrical conductivity readings taken from pooled water with an Oakton PCSTestr 35. A puddle on the pad surface near the production tanks is 0.06 mS/cm. JLP |
For data sources see[8]