If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-023-20179 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.57087,"lon":-78.351211,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cameron | |
Municipality: Shippen Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 151772 | |
Farm/Lease Name: SRC WT 5034 81H | |
License Status: Active | |
Spud Date: 2015-03-09 | |
Permit Date: 2014-10-10 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.570870 | |
Longitude: -78.351211 |
Date | Event |
---|---|
2014-10-10 | New Permit Application |
2014-12-19 | New Permit Application |
2015-03-09 | Performed Spud Operation |
2015-05-14 | Drilling Completion |
2017-08-10 | Perforation |
2017-08-10 | Performed Stage 1 of Stimulation |
2017-08-11 | Perforation |
2017-08-11 | Performed Stage 2 of Stimulation |
2017-08-11 | Performed Stage 3 of Stimulation |
2017-08-12 | Perforation |
2017-08-12 | Performed Stage 4 of Stimulation |
2017-08-13 | Perforation |
2017-08-13 | Performed Stage 5 of Stimulation |
2017-08-14 | Perforation |
2017-08-14 | Performed Stage 6 of Stimulation |
2017-08-14 | Performed Stage 7 of Stimulation |
2017-08-14 | Performed Stage 8 of Stimulation |
2017-08-15 | Perforation |
2017-08-15 | Performed Stage 10 of Stimulation |
2017-08-15 | Performed Stage 11 of Stimulation |
2017-08-15 | Performed Stage 12 of Stimulation |
2017-08-15 | Performed Stage 9 of Stimulation |
2017-08-16 | Perforation |
2017-08-16 | Performed Stage 13 of Stimulation |
2017-08-16 | Performed Stage 14 of Stimulation |
2017-08-16 | Performed Stage 15 of Stimulation |
2017-08-17 | Perforation |
2017-08-17 | Performed Stage 16 of Stimulation |
2017-08-17 | Performed Stage 17 of Stimulation |
2017-08-18 | Perforation |
2017-08-18 | Performed Stage 18 of Stimulation |
2017-08-18 | Performed Stage 19 of Stimulation |
2017-08-19 | Perforation |
2017-08-19 | Performed Stage 20 of Stimulation |
2017-08-19 | Performed Stage 21 of Stimulation |
2017-08-19 | Performed Stage 22 of Stimulation |
2017-08-21 | Perforation |
2017-08-21 | Performed Stage 23 of Stimulation |
2017-08-21 | Performed Stage 24 of Stimulation |
2017-08-21 | Performed Stage 25 of Stimulation |
2017-08-21 | Performed Stage 26 of Stimulation |
2017-08-22 | Perforation |
2017-08-24 | Perforation |
2017-08-24 | Performed Stage 27 of Stimulation |
2017-08-24 | Performed Stage 28 of Stimulation |
2017-08-24 | Performed Stage 29 of Stimulation |
2017-08-25 | Perforation |
2017-08-25 | Performed Stage 30 of Stimulation |
2017-08-25 | Performed Stage 31 of Stimulation |
2017-08-26 | Perforation |
2017-08-26 | Performed Stage 32 of Stimulation |
2017-08-26 | Performed Stage 33 of Stimulation |
2017-08-27 | Perforation |
2017-08-27 | Performed Stage 34 of Stimulation |
2017-08-27 | Performed Stage 35 of Stimulation |
2017-08-28 | Perforation |
2017-08-28 | Performed Stage 36 of Stimulation |
2017-08-28 | Performed Stage 37 of Stimulation |
2017-08-28 | Performed Stage 38 of Stimulation |
2017-08-29 | Perforation |
2017-08-29 | Performed Stage 39 of Stimulation |
2020-02-24 | Deviated |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-08-10 | 2017-08-29 | 5,364 | 9,103,460 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | KFEAC-30 | Keane | Iron Control | Acetic acid | 64-19-7 | 60 | 0.000448781 | 389.15 |
Citric acid | 77-92-9 | 40 | 0.000299188 | 259.433 | ||||
MBC-516 | Keane | Biocide | gluteral | 111-30-8 | 26.7 | 0.0023122 | 2004.97 | |
Didecyl dimethyl ammonium chloride | 7173-51-5 | 8 | 0.000690196 | 598.487 | ||||
quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.3 | 0.000459842 | 398.741 | ||||
ethanol | 64-17-5 | 2.8 | 0.000242478 | 210.259 | ||||
KFR-20 | Keane | Friction Reducer | Ammonium Chloride | 12125-02-9 | 1 | 0.000882732 | 765.44 | |
Alcohols, C12-16, ethoxylated | 68551-12-2 | 2 | 0.00176546 | 1530.88 | ||||
oleic acid diethanolamide | 93-83-4 | 2 | 0.00176546 | 1530.88 | ||||
Mineral oil/ light hydrotreated pet. distillate | 64742-47-8 | 20 | 0.0176546 | 15308.8 | ||||
cololymer of 2-propenamide | 69418-26-4 | 30 | 0.026482 | 22963.2 | ||||
Water | 7732-18-5 | 45 | 0.0397229 | 34444.8 | ||||
KSI-19 NW | Keane | Scale Inhibitor | Aqueous Solution | Proprietary | 100 | 0.0109332 | 9480.5 | |
7.5% Acid | Keane | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0340359 | 29513.4 | |
Water | 7732-18-5 | 92.5 | 0.419776 | 363999 | ||||
Water (Clean - Acid - Chems) | Seneca Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.6093 | 75,968,400.0 | |
KAI-12 | Keane | Acid Inhibitor | propan-2-ol | 67-63-0 | 5 | 0.00005905 | 51.204 | |
ethylbenzene | 100-41-4 | 1 | 0.00001181 | 10.241 | ||||
xylne | 1330-20-7 | 5 | 0.00005905 | 51.204 | ||||
fatty imidazoline | 61790-69-0 | 5 | 0.00005905 | 51.204 | ||||
methanol | 67-56-1 | 90 | 0.0010629 | 921.671 | ||||
prop-2-yn-1-0l | 107-19-7 | 5 | 0.00005905 | 51.204 | ||||
alcohols, c7-9-0so, c8-rich | 68526-83-0 | 5 | 0.00005905 | 51.204 | ||||
DustProof (Proppant) | Keane | Proppant | Blend | Proprietary | 0.1 | 0.0118271 | 10255.5 | |
Crystalline silica: Quartz (SiO2) | 14808-60-7 | 99.9 | 11.8152 | 10,245,300.0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2017-08-10 | 1 | Ottawa | 1,025,844 | 8,131 | 7,352 |
2017-08-11 | 2 | Ottawa | 1,025,844 | 8,345 | 5,945 |
2017-08-11 | 3 | Ottawa | 1,025,844 | 7,792 | 4,841 |
2017-08-12 | 4 | Ottawa | 1,025,844 | 8,029 | 4,775 |
2017-08-13 | 5 | Ottawa | 1,025,844 | 7,826 | 4,633 |
2017-08-14 | 6 | Ottawa | 1,025,844 | 7,905 | 6,077 |
2017-08-14 | 7 | Ottawa | 1,025,844 | 8,210 | 5,910 |
2017-08-14 | 8 | Ottawa | 1,025,844 | 7,973 | 5,554 |
2017-08-15 | 9 | Ottawa | 1,025,844 | 7,920 | 5,971 |
2017-08-15 | 10 | Ottawa | 1,025,844 | 7,965 | 6,062 |
2017-08-15 | 11 | Ottawa | 1,025,844 | 8,265 | 5,572 |
2017-08-15 | 12 | Ottawa | 1,025,844 | 8,399 | 5,426 |
2017-08-16 | 13 | Ottawa | 1,025,844 | 8,223 | 5,808 |
2017-08-16 | 14 | Ottawa | 1,025,844 | 8,173 | 5,239 |
2017-08-16 | 15 | Ottawa | 1,025,844 | 8,279 | 5,045 |
2017-08-17 | 16 | Ottawa | 1,025,844 | 7,998 | 6,049 |
2017-08-17 | 17 | Ottawa | 1,025,844 | 7,609 | 5,344 |
2017-08-18 | 18 | Ottawa | 1,025,844 | 7,831 | 5,210 |
2017-08-18 | 19 | Ottawa | 1,025,844 | 7,289 | 5,101 |
2017-08-19 | 20 | Ottawa | 1,025,844 | 7,440 | 5,826 |
2017-08-19 | 21 | Ottawa | 1,025,844 | 7,560 | 4,961 |
2017-08-19 | 22 | Ottawa | 1,025,844 | 7,182 | 5,262 |
2017-08-21 | 23 | Ottawa | 1,025,844 | 7,067 | 4,682 |
2017-08-21 | 24 | Ottawa | 1,025,844 | 6,945 | 5,336 |
2017-08-21 | 25 | Ottawa | 1,025,844 | 6,707 | 5,263 |
2017-08-21 | 26 | Ottawa | 1,025,844 | 6,531 | 5,354 |
2017-08-24 | 27 | Ottawa | 1,025,844 | 6,746 | 5,734 |
2017-08-24 | 28 | Ottawa | 1,025,844 | 6,763 | 4,669 |
2017-08-24 | 29 | Ottawa | 1,025,844 | 7,030 | 5,037 |
2017-08-25 | 30 | Ottawa | 1,025,844 | 6,314 | 4,166 |
2017-08-25 | 31 | Ottawa | 1,025,844 | 6,335 | 4,599 |
2017-08-26 | 32 | Ottawa | 1,025,844 | 5,674 | 4,571 |
2017-08-26 | 33 | Ottawa | 1,025,844 | 6,280 | 5,292 |
2017-08-27 | 34 | Ottawa | 1,025,844 | 5,753 | 4,897 |
2017-08-27 | 35 | Ottawa | 1,025,844 | 5,789 | 4,709 |
2017-08-28 | 36 | Ottawa | 1,025,844 | 5,789 | 4,411 |
2017-08-28 | 37 | Ottawa | 1,025,844 | 5,721 | 4,241 |
2017-08-28 | 38 | Ottawa | 1,025,844 | 5,892 | 4,721 |
2017-08-29 | 39 | Ottawa | 1,025,844 | 5,612 | 5,129 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 105,459.96 | 61 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 113,365.95 | 149 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 107,006.18 | 245 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | SENECA RESOURCES CO LLC | Drill Cuttings | 1,334.19 Tons | LANDFILL | 100361 |
2016 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 3.21 Tons | LANDFILL | 100361 |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 96.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 25.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2016 | SENECA RESOURCES CO LLC | Servicing Fluid | 96.25 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 166.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 43,778.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 55.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.73 Tons | LANDFILL | 100361 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 1,108.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Unused Fracturing Fluid Waste | 279.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 79.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Unused Fracturing Fluid Waste | 0.69 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 206.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | SENECA RESOURCES CO LLC | Waste Water Treatment Sludge | 29.26 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 30,164.48 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Soil Contaminated by Oil & Gas Related Spills | 8.24 Tons | LANDFILL | 100361 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 208.75 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
2018 | SENECA RESOURCES CO LLC | Soil Contaminated by Oil | 8.24 Tons | LANDFILL | 100361 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 131.25 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 1.25 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 331.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.50 Tons | LANDFILL | 100361 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 12.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.26 Tons | LANDFILL | 100361 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 7,864.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 384.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 337.08 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 27.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 111.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 71.25 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2351137 | Primary Facility | 2015-03-11 | Routine/Complete Inspection | No Violations Noted | |
2351804 | Primary Facility | 2015-03-12 | Drilling/Alteration | No Violations Noted | At the time of inspection Sunny sky ~12” snow cover and ~27° F. |
2353598 | Primary Facility | 2015-03-19 | Routine/Complete Inspection | No Violations Noted | |
2355696 | Primary Facility | 2015-03-25 | Drilling/Alteration | No Violations Noted | At the time of inspection Cloudy sky, light rain and ~33° F. |
2357080 | Primary Facility | 2015-04-01 | Routine/Complete Inspection | No Violations Noted | |
2358081 | Primary Facility | 2015-04-02 | Routine/Complete Inspection | No Violations Noted | |
2359971 | Primary Facility | 2015-04-07 | Routine/Complete Inspection | No Violations Noted | At the time of inspection cloudy sky, light rain and ~45° F. |
2365281 | Primary Facility | 2015-04-23 | Routine/Complete Inspection | No Violations Noted | |
2378099 | Primary Facility | 2015-06-05 | Drilling/Alteration | No Violations Noted | At the time of inspection sunny sky, ~ 70° F. |
2432280 | Primary Facility | 2015-12-08 | Routine/Complete Inspection | No Violations Noted | |
2470517 | Primary Facility | 2016-03-30 | Routine/Complete Inspection | No Violations Noted | |
2474098 | Primary Facility | 2016-04-12 | Routine/Complete Inspection | No Violations Noted | |
2506062 | Primary Facility | 2016-07-27 | Routine/Complete Inspection | No Violations Noted | |
2610263 | Primary Facility | 2017-06-13 | Routine/Complete Inspection | No Violations Noted | |
2616244 | Primary Facility | 2017-07-18 | Administrative/File Review | Violation(s) Noted | Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well. |
2622110 | Primary Facility | 2017-07-26 | Routine/Complete Inspection | No Violations Noted | Routine inspection of Seneca Resources Corp CRV PAD C09-G on July 26, 2017. No one was onsite during my inspection.
Rig mats remain onsite with a total of 25 produced fluids frac containers. It appears that the operator is gearing up for well stimulation. All wells are labeled with the well number and operator. A total of 9 wells have been TD. Well 023-20182 has been drilled and plugged. There are 6 produced fluids silos located in secondary containment onsite. Field screen reading for specific conductance within this containment was 82.0 uS/cm. Overall, the pad is in good condition and all necessary BMPs are in place surrounding the well pad. The sign located at the entrance to the well pad only has a total of 7 well listed. This does not match with the number of drilled wells onsite. I recommend updating the well site to reflect the number of drilled wells onsite. |
2627514 | Primary Facility | 2017-08-18 | Routine/Complete Inspection | No Violations Noted | Routine inspection of Seneca Resources Corp CRV PAD C09-G on August 17, 2017 with company man Adam Pierce of Seneca Resources.
Crews were currently working on fracing Marcellus wells 023-20178, 023-20179, 023-20183, and 023-20184. The fracing crew was approximately half way done with fracing these four wells. Once finished they will move the rig over and work on stimulating Marcellus wells 023-20180, 023-20181, 023-20182, and 023-20198. According to Mr. Pierce, crews are installing a perforation string downhole and with 8 perforation holes per every 2 ft. section of the string. Plugs made of a composite are being placed between 190 ft. perforation stages. Sand is being hauled via trucks from the Cameron County rail yard. Water used for stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks. All equipment is placed on secondary containment. Overall, the pad is i |
2630937 | Primary Facility | 2017-08-15 | Routine/Complete Inspection | No Violations Noted | |
2643024 | Primary Facility | 2017-09-28 | Routine/Complete Inspection | No Violations Noted | Routine inspection of Seneca Resources Corp CRV PAD C09-G on September 28, 2017 with company man Scott Digel of Seneca Resources.
Crews were currently working on fracing Marcellus wells 023-20182, 023-20183, and 023-20184. The fracing crew was almost completed with well stimulation on these 3 wells. Stimulation been completed on wells 023-20178, 023-20179, 023-29180, 023-20181, and 023-20198. According to Mr. Digel, once all of the wells have been stimulated, crews will remove this rig and bring in 2 work-over rigs to drill out the plugs on the above mentioned wells. Sand is being hauled via trucks from the Cameron County rail yard, then being trucked to this site. Water used for well stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks. These tanks are located along the Eastern border of the pad. All equipment is placed on secondary containment. Overall, th |
2668298 | Primary Facility | 2017-12-06 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. The tubing (production) pressure was 945 psi. at this inspection. All fittings and vented annulus , the 20x13, 13x9 and the 9x5 were checked at this inspection. The well pad and well area is neat and organized. |
2672456 | Primary Facility | 2017-12-15 | Routine/Complete Inspection | No Violations Noted | Routine inspection of Seneca Resources CRV PAD C09-G on December 15, 2017.
There are a total of 8 producing Marcellus wells located on this pad. Rig mats from the recent flowback operation have been removed and are currently being stationed along the N edge of the well pad. There is one frac tank stationed on man-made secondary containment with a berm near the well heads. There are 4 frac tanks located near the produced fluids containment along the S border. These frac tanks are currently not located in secondary containment nor to they appear to be connected to anything. There are (6) 400 BBL produced fluids tanks located in modular secondary containment. Water within the containment is frozen and snow covered. In addition, there's a row of 22 frac tanks stationed along the E edge of the well pad. This series of 22 frac tanks are stationed in secondary man made containment with a berm. There are 8 gas production units stationed along the W edge of the well pad. The pad and surrounding areas are snow cove |
2707899 | Primary Facility | 2018-03-20 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. The wellhead assembly, annulus vents 20" x 13 3/8", 13 3/8" x 9 5/8" and 9 5/8" x 5 1/2" were tested for gas. Results of this testing was that 100% LEL(lower explosion limit) and 12% Methane was detected on the 9 5/8" x 5 1/2" annulus vent. No other gas was detected on the wellhead assembly or the well area. |
2734707 | Primary Facility | 2018-05-24 | Incident- Response to Accident or Event | No Violations Noted | I arrived onsite and met with Jeff Passarello of Seneca in response to a spill report. Between 3 and 4 AM on 5/24, a worker on the site set up to pump produced water from both the Baker tank battery and the production tanks to the Clermont storage facility. The same pump is used to pump water from the well cellars (when needed) along with the produced water, but no pumping was occurring at the cellars. A water line is left in place to the cellars, but capped ~20' from the cellars to allow vehicle traffic through. When the worker turned on the pump, the cap popped off of the water line to the cellars and spilled ~1 1/2 barrels of produced water from the pump to the pad surface. When I arrived, approximately a third to a half of the spill area had already been excavated and a 30 yard dumpster filled. Jeff informed me that they were waiting on another rolloff to continue the excavation. The gravel was underlain by a clay layer, making visual confirmation of the spill removal possible, but Jeff was also u |
2792964 | Primary Facility | 2018-10-16 | Routine/Complete Inspection | No Violations Noted | Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV C09-G Well Pad on October 16, 2018. There are a total of 8 drilled and producing wells located on this well pad. All well heads are properly tagged. Well cellars are full of water. No bubbling or sheen observed in the cellars. There are (6) 400 bbl. produced fluids tanks stationed in secondary containment. Approximately 1" of rain water was found in the produced fluids secondary containment with a conductivity reading of 78.8 uS/cm. A series of 12 manifolded frac tanks are being stationed on secondary along the NE edge of the well pad. Just a trace of water was observed within this containment. Overall, the well site looks good. No violations noted. |
2807515 | Primary Facility | 2018-11-28 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. There are three (3) annulus vents openly venting on this well. Annulus vent 9 5/8" x 5" was venting 100% LEL (lower explosion limit) and 52% METHANE at this inspection. No other annulus vents were noted venting at this inspection. No violations noted at the time of this inspection. |
2808922 | Primary Facility | 2018-11-29 | Routine/Complete Inspection | No Violations Noted | Seneca Resources submitted a spud notice to the Department via the Greenport system on November 21, 2018 for the following Utica wells: 023-20238 through 023-20243.
Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV Pad C09-G on November 29, 2018. Each 20" round 100' in length conductor was in-place for the above listed wells. In addition, there are a total of 8 producing Marcellus wells located on the pad. Overall, the well pad was snow covered and frozen. No signs of leaks or spills were observed on the well pad. No violations noted. |
2843471 | Primary Facility | 2019-02-21 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. 728 psi (pounds per square inch) was showing as the production/ flow line at the time of this inspection. This well has 3 annulus vents vented to surface. The annulus vents were all tested for combustible gas with a Altair 5 x Multi gas meter. The results were the 20" x 13" tested 0% LEL (lower explosion limit) and 0% METHANE. 13" x 9" tested 0% LEL (lower explosion limit) and 0% METHANE. The 9" x 5" tested 100% LEL (lower explosion limit) and 4% METHANE. This meter was calibrated on 2-20-19. No violations noted at this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2616244 | 791559 | 2017-07-18 | 2017-08-16 | 78a91(a) | Environmental Health & Safety | The SRC WT 5034 81H well was drilled to total depth on May 16, 2015 under the authorization of well permit number 023-20179. No production has ever been reported for the SRC WT 5034 81H well. The well is therefore considered "abandoned" in accordance with Section 3203 of the 2012 Oil and Gas Act, |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
791559 | 356250 | NOV - Notice of Violation | 2017-08-16 |
For data sources see[9]