37-123-47594

Well Details

Well ID: 37-123-47594
Loading map...
Country: United States
State: Pennsylvania
County: Warren
Municipality: Sugar Grove Township
Operator Name:
Well Pad ID:
Farm/Lease Name: CHURCH LEASE CHURCH 7
License Status:
Spud Date:
Permit Date: 2014-08-13
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.970919
Longitude: -79.291006

For data sources see[1][2][3]

Well History

Date Event
2014-08-13 New Permit Application
2014-09-22 Performed Spud Operation
2014-09-24 Drilling Completion
2014-10-23 Perforation
2015-01-07 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CHAUTAUQUA ENERGY INC 1.00 365 19.00 365 0.00 0
2015 CHAUTAUQUA ENERGY INC 0.00 0 157.00 365 0.00 0
2016 CHAUTAUQUA ENERGY INC 0.00 0 46.00 365 0.00 0
2017 CHAUTAUQUA ENERGY INC 13.00 365 32.00 365 0.00 0
2018 CHAUTAUQUA ENERGY INC 164.00 365 46.00 365 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CHAUTAUQUA ENERGY INC Produced Fluid 33.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2015 CHAUTAUQUA ENERGY INC Produced Fluid 166.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2016 CHAUTAUQUA ENERGY INC Produced Fluid 147.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2017 CHAUTAUQUA ENERGY INC Produced Fluid 127.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2018 CHAUTAUQUA ENERGY INC Produced Fluid 199.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2019 Produced Fluid 42.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE 001-A

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2274720 Primary Facility 2014-05-26 Routine/Partial Inspection No Violations Noted This inspection was in conjunction with a request from the permitting section to look at the well site prior to issuing the permit because it was in close proximity to a wetland greater than 1 acre. The border of the wetland was delineated and was well defined. The Well stake was approximately 50 ft from the edge of the wetland. I requested that they move the well south 45 feet to insure that there was an adaquate buffer. There should be adaquate permeter controls. Pits must be 100 ft from the edge of the wetland in order to encapsulate. Dusting should not be permitted because of the close proximity to the wetland.
2304911 Primary Facility 2014-09-15 Routine/Complete Inspection No Violations Noted Conventional oil well. The well pad has been constructed but the well has not yet been drilled.The site was constructed as per permit requirements. There are adaquate perimeter controls. No violations noted at this time.
2306609 Primary Facility 2014-09-23 Routine/Complete Inspection No Violations Noted Conventional oil well in the process of being drilld. Cuttings were being blown into a roll-off container. There were adaquate perimeter controls. The access road and location were stoned and stable. No violations noted at this time.
2307622 Primary Facility 2014-09-23 Drilling/Alteration No Violations Noted
2308642 Primary Facility 2014-09-29 Routine/Complete Inspection No Violations Noted Conventional oil well recently drilled but not yet fraced. The drill cuttings were directed into a lined roll off container as per permit conditions. There were adaquate erosion control measures. The location was stoned and stable. No violations noted at this time.
2316744 Primary Facility 2014-10-23 Routine/Complete Inspection No Violations Noted Conventional oil well in the process of being fraced. The operator was on stage 2 of a 10 stage frac. All fluids were contained in a lined roll-off container and a lined sump. The location was stoned and stable. No violations noted at this time.
2326501 Primary Facility 2014-12-05 Administrative/File Review No Violations Noted

For data sources see[7]

References