If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21493 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.849495,"lon":-76.949087,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Rutland Township | |
Operator Name: SWEPI LP | |
Well Pad ID: 148713 | |
Farm/Lease Name: KREITZER R 505W 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-04-03 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.849495 | |
Longitude: -76.949087 |
Date | Event |
---|---|
2012-04-03 | New Permit Application |
2012-05-30 | Performed Spud Operation |
2012-07-06 | Drilling Completion |
2013-06-08 | Perforation |
2014-07-21 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-06-13 | 2013-07-09 | 5,512 | 3,691,340 | 242,382 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | MSI-7 | National Petrochem | Scale Inhibitor | Hydrogen Chloride | 7647-01-0 | 100 | 0.00858902 | 3069 |
Sand | Operator | Proppant | Silicon Dioxide | 14808-60-7 | 100 | 13.1027 | 4,681,810.0 | |
Bio-Clear 5000 | Clearwater International LLC | Biocide | Proprietary | Proprietart | 95 | 0.00450301 | 1609 | |
2,2-dibromo-3-nitril oprop ionam ide | 10222-01-2 | 5 | 0.000237884 | 85 | ||||
Water | Operator | Base Carrier Fluid | Water | 7732-18-5 | 100 | 86.1582 | 30,785,800.0 | |
Plexgel Breaker 10L | Chemplex, L.C. | Breaker | No Hazardous Ingredients | Proprietary | 100 | 0.000257475 | 92 | |
Petro-Flo | Bio-Cide International, Inc | Biocide | Sodium Carbonate | 497-19-8 | 2 | 0.000131536 | 47 | |
Sodium Hydroxide | 1310-73-2 | 1 | 0.00006437 | 23 | ||||
Sodium Chlorite | 7758-19-2 | 8.35 | 0.000548533 | 196 | ||||
Sodium Chloride | 7647-14-5 | 1 | 0.00006437 | 23 | ||||
FR900 | Nalco | Friction Reducer | Proprietary | Proprietary | 100 | 0.078429 | 28024 | |
I-22 | Nalco | Corrosion Inhibitor | Cyclic alkanes | Proprietary | 5 | 0.000114744 | 41 | |
Quaternary ammonium compound | Proprietary | 30 | 0.000685666 | 245 | ||||
Quaternary ammonium compound | Proprietary | 5 | 0.000114744 | 41 | ||||
Formic Acid | 64-18-6 | 60 | 0.00137413 | 491 | ||||
Isopropanol | 67-63-0 | 10 | 0.000229488 | 82 | ||||
Oxyalkylated Fatty Acid Derivative | Proprietary | 30 | 0.000685666 | 245 | ||||
Aromatic aldehyde | Proprietary | 30 | 0.000685666 | 245 | ||||
2-Mercaptoethyl Alcohol | 60-24-2 | 5 | 0.000114744 | 41 | ||||
Methanol | 67-56-1 | 5 | 0.000114744 | 41 | ||||
FE-4 | Chemplex, L.C. | Iron Control Additive | Water | 7732-18-5 | 55 | 0.0010327 | 369 | |
Citric Acid Anhydrous | 77-92-9 | 55 | 0.0010327 | 369 | ||||
BIO-CLEAR 200 | Clearwater International, LLC | Iron Control | Polyethylene Glycol Mixture | 25322-68-3 | 60 | 0.030827 | 11015 | |
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 20 | 0.0102766 | 3672 | ||||
15% Hydrochloric Acid | Reagent | Scale Dissolver | 36% Hydrochloric Acid | 7647-01-0 | 15 | 0.0846756 | 30256 | |
Water | 7732-18-5 | 85 | 0.479824 | 171449 | ||||
EDTA-ACID | Univar | Iron Control | Ethylenediaminetetraacetic acid | 60-00-4 | 99 | 0.000736042 | 263 | |
Water | 7732-18-5 | 1 | 0.00000840 | 3 | ||||
Plexgel 907 | Chemplex, L.C. | Gellant | Guar Gum | 9000-30-0 | 100 | 0.019722 | 7047 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 223,728.67 | 136 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 295,118.07 | 334 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 276,016.88 | 292 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 233,968.97 | 277 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 177,045.05 | 249 | 0.00 | 0 | 0.00 | 0 |
2018 | SWEPI LP | 181,494.68 | 280 | 0.00 | 0 | 0.00 | 0 |
2019 | SWEPI LP | 169,346.60 | 301 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SWEPI LP | Drilling Fluid Waste | 111.90 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | SWEPI LP | Fracing Fluid Waste | 169.05 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SWEPI LP | Drill Cuttings | 2,187.15 Tons | LANDFILL | 9312 |
2012 | SWEPI LP | Fracing Fluid Waste | 300.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | SWEPI LP | Produced Fluid | 10,336.42 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SWEPI LP | Drilling Fluid Waste | 887.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SWEPI LP | Drilling Fluid Waste | 276.42 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | SWEPI LP | Fracing Fluid Waste | 5.88 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2013 | SWEPI LP | Produced Fluid | 268.12 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | SWEPI LP | Fracing Fluid Waste | 261.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | SWEPI LP | Fracing Fluid Waste | 13,785.64 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SWEPI LP | Drill Cuttings | 666.10 Tons | LANDFILL | 301358 |
2014 | SWEPI LP | Produced Fluid | 8,153.22 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SWEPI LP | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | SWEPI LP | Basic Sediment | 129.20 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | SWEPI LP | Fracing Fluid Waste | 25.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SWEPI LP | Produced Fluid | 52.08 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | SWEPI LP | Produced Fluid | 450.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SWEPI LP | Drilling Fluid Waste | 1.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWEPI LP | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC011 |
2015 | SWEPI LP | Produced Fluid | 127.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SWEPI LP | Drill Cuttings | 159.10 Tons | LANDFILL | 301358 |
2015 | SWEPI LP | Produced Fluid | 60.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SWEPI LP | Drilling Fluid Waste | 105.57 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Produced Fluid | 33.62 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Fracing Fluid Waste | 33.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWEPI LP | Produced Fluid | 1,842.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWEPI LP | Synthetic Liner Materials | 0.09 Tons | LANDFILL | 301358 |
2016 | SWEPI LP | Produced Fluid | 133.06 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016 | SWEPI LP | Produced Fluid | 24.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | SWEPI LP | Produced Fluid | 4,065.74 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWEPI LP | Waste Water Treatment Sludge | 2.26 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | SWEPI LP | Synthetic Liner Materials | 0.62 Tons | LANDFILL | 301358 |
2017 | SWEPI LP | Produced Fluid | 20.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | SWEPI LP | Produced Fluid | 805.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017 | SWEPI LP | Produced Fluid | 1,495.88 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Produced Fluid | 725.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2018 | SWEPI LP | Produced Fluid | 742.43 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Produced Fluid | 169.24 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWEPI LP | Produced Fluid | 124.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SWEPI LP | Produced Fluid | 225.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | SWEPI LP | Soil Contaminated by Oil & Gas Related Spills | 2.41 Tons | LANDFILL | 301358 |
2019 | SWEPI LP | Produced Fluid | 163.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SWEPI LP | Soil Contaminated by Oil | 2.41 Tons | LANDFILL | 301358 |
2019 | SWEPI LP | Produced Fluid | 140.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2019 | SWEPI LP | Produced Fluid | 458.85 Bbl | REUSE (AT WELL PAD) | |
2019 | SWEPI LP | Produced Fluid | 253.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2071000 | Primary Facility | 2012-05-25 | Routine/Complete Inspection | No Violations Noted | Shell plans to spud on 30 MAY 2012 |
2132544 | Primary Facility | 2013-01-22 | Routine/Complete Inspection | No Violations Noted | spud-not. very steep slopes unstabilized. setting conductors on 1H, 3H, 4H, 6H |
2138900 | Primary Facility | 2013-01-16 | Routine/Complete Inspection | No Violations Noted | |
2143569 | Primary Facility | 2013-02-27 | Routine/Complete Inspection | No Violations Noted | |
2180369 | Primary Facility | 2013-07-01 | Incident- Response to Accident or Event | Violation(s) Noted | Est. 50 bbl spill of flowback onto the ground. Fluid migrated to E&S control and beyond limit of disturbance. Rutland Twp, Tioga Co. TLT |
2180607 | Primary Facility | 2013-07-02 | Incident- Response to Accident or Event | Outstanding Violations - No Viols Req'd | 50 brl frac release reported |
2180868 | Primary Facility | 2013-07-05 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | 5.4 mS/cm, took sample of liquid in ST4 |
2182228 | Primary Facility | 2013-07-10 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2184646 | Primary Facility | 2013-07-17 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | 70 gal hyd oil spill reported. Immediately corrected |
2199987 | Primary Facility | 2013-08-27 | Compliance Evaluation | Recurring Violations | Puddles 9-12 mS/cm. took a sample |
2237229 | Primary Facility | 2014-01-14 | Routine/Complete Inspection | No Violations Noted | Closing viols from August 27, 2013 ( 2199987) frac spills. 4 gas wells producing |
2260284 | Primary Facility | 2014-04-03 | Routine/Complete Inspection | No Violations Noted | |
2318717 | Primary Facility | 2014-10-01 | Routine/Complete Inspection | No Violations Noted | |
2379316 | Primary Facility | 2015-06-16 | Routine/Complete Inspection | No Violations Noted | |
2392207 | Primary Facility | 2015-07-23 | Incident- Response to Accident or Event | No Violations Noted | 1 drilling mud release, 2 flowback releases, 1 hydraulic oil realease reported. Setting up to hydraulically fracture 21H Marcellus well. |
2671270 | Primary Facility | 2017-12-14 | Routine/Partial Inspection | No Violations Noted | No electrical conductivity readings from liquid today, as the site is frozen |
2702309 | Primary Facility | 2018-03-07 | Routine/Partial Inspection | No Violations Noted | I got electrical conductivity (EC) readings from liquid pooled on site with an Oakton PCSTestr 35. A puddle on the pad gave a 0.14 mS/cm reading.
SWEPI inspection logbook is in mailbox near production tanks; it lists last inspection on March 4, 2018. Air temp 33F. JLP |
2788131 | Primary Facility | 2018-10-12 | Routine/Complete Inspection | No Violations Noted | Cool/windy at time of inspection. |
2852321 | Primary Facility | 2019-03-12 | Routine/Complete Inspection | No Violations Noted | The DEP conducted a routine inspection of SWEPI's Kreitzer 505 Well Site in Rutland Twp, Tioga County on 3/12/2019 at 1200 hours. The weather was partly cloudy and 30 degrees. The act 9 sign was observed at the entrance to the site. The E&S Plan was available for review in the mailbox by the entrance. The Onsite inspection log was in the mailbox by the production tanks. Company personnel last inspected the site on 3/12/2019 noting no issues.
There is currently 4 Marcellus (1H-4H) and 1 Utica (21H) producing wells onsite. The pad is well vegetated and stabilized and no erosional issues were observed onsite today. Containment structures were intact and functioning. All PCSM BMPs were present and functioning properly. There was no evidence of spills or releases onsite today. No violations or issues noted today, I departed the site at 1245. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2180369 | 671960 | 07/01/2013 | 2013-07-01 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | 78.54 for failure to control stimulation fluids. Estimated 50 bbl of flowback released from 12" line during frac operations. TLT |
2180369 | 671961 | 07/01/2013 | 2013-07-01 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | 691.402 Clean Streams Law for an unpermitted discharge with potential to pollute Waters of the Commonwealth. Est. 50 bbl of flowback released from 12" line during frac operation. Fluid migrated to sediment trap and beyond limit of disturbance. TLT |
2180369 | 671962 | 07/01/2013 | 2013-07-01 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 6018.301 Solid Waste Management Act for an unpermitted discharge of a residual waste onto the ground. Est. 50 bbl of flowback released from 12" line during frac operation. Fluid discharge to ground and migrated beyond limit of disturbance. TLT |
2184646 | 672960 | 07/17/2013 | 2013-07-17 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 70 gal hyd oil release. Absorbents used, then removed waste. |
2199987 | 676408 | 08/27/2013 | 2013-08-27 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | Puddles 9-12 mS/cm |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
671960 | 299433 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
671961 | 299433 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
671962 | 299433 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 |
For data sources see[8]