If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-20105 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.786636,"lon":-76.230888,"icon":""}]} |
County: Bradford | |
Municipality: Herrick Township | |
Operator Name: SOUTHWESTERN ENERGY PROD CO | |
Well Pad ID: 148443 | |
Farm/Lease Name: GREENZWEIG 1H | |
First Permit Date: 2008-09-09 | |
Last Permit Date: 2008-09-09 | |
Spud Date: 2008-09-22 | |
Unconventional: Yes | |
Horizontal: Yes | |
Producing: Yes | |
Violations: 1 | |
Latitude: 41.786636 | |
Longitude: -76.230888 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID |
---|---|---|---|---|
1740741 | 2008-10-07 | No Violations Noted | ||
1981508 | 2011-06-13 | No Violations Noted | Refer to the Greenzweig #1 for inspection report comments. | |
2006341 | 2011-09-13 | No Violations Noted | The intent of the inspections was to assure the flowback water did not exceed the 2¿ freeboard requirement as per 25 PA code 78.56 (a) (2) and the liner did not experience compromised integrity as per 25 PA code 78.56 (a) (4), due to recent rainfall events from tropical storms. During the inspection, the freeboard level was observed to be right at the 2¿ freeboard level. Compromised integrity of the impoundment liners was not noted. Jason Petlock of Southwestern informed us that prior to 9/14 the freeboard level was slightly exceeded in the 40,000 barrel capacity flowback water only impoundment; Permit number ESX10-015-0078. Southwestern transferred water from this impoundment to vertical holding tanks in the tank farm area to keep the surface water elevation as low as possible. Some staining and water marks were observed form the surface of the water to the top portion of the liner. The 200,000 barrel capacity flowback/fresh water blended impoundment, Permit Number ESX10-015-0072, did not experience freeboard exceeding and staining. | |
2027575 | 2011-12-19 | Violation(s) Noted | 627155 | |
2073306 | 2012-06-04 | No Violations Noted | Violations and specifcs associated with this inspection have been attached to the Greenzweig Unit #1 inspection report. Permit number is 37-015-20081.
(Permit #37-015-20081) |
|
2074338 | 2012-06-08 | Adverse Events or Actions Reported | Inspection part of a contunuing investigation into the identified chloride elevated seeps located on the fill slope of the tank farm pad. Sample # 0257070 was collected from the discharge of the small laggon underdrain discharge. Primary focus of investigation is to determine the status of the integrity of the small lagoon liner. Large lagoon liner integrity is not in question at this time. | |
2074903 | 2012-06-11 | No Violations Noted | Violations and specfics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report. Permit number is 37-015-20081. | |
2075047 | 2012-05-15 | No Violations Noted | Please refer to the Greenzweig Unit #1 inspection report regarding details of the investigation. Permit number is 37-015-20081. | |
2098044 | 2012-09-05 | No Violations Noted | Violations and specifics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report. Permit number is 37-015-20081.
|
|
2099253 | 2012-09-10 | Outstanding Violations - No Viols Req'd | Inspection conducted on 9/10/12 with Rich Gulyas. 2 new monitoring wells have been installed. One is located below the small impoundment, and the other is located below well pad and between the large and small impoundment. Drill cuttings and casing sealant debris is located around both new monitoring wells. Rich said he would get rid of this debris ASAP. The sump pump located in the sump cellar which was installed in the rocked swale right above the small impoundment is not functional. Rich not sure why. Please send an email explaining your intentions for this sump pump. |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2012-2 | 212573.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 238522.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 262029.0 | 128.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 341445.0 | 175.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-2 | 395483.0 | 174.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-3 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2009-0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2012-2 | DRILL CUTTINGS | 397.29 | Tons | LANDFILL | 101247 | KEYSTONE SANITARY LANDFILL | DUNMORE | PA |
2012-1 | FLOWBACK FRACTURING SAND | 2.95 | Tons | LANDFILL | 101247 | KEYSTONE SANITARY LANDFILL | DUNMORE | PA |