X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-115-24076"

m
 
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-115-24076
 
| Well ID: 34-115-24076
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.7113839022, -81.9232438052 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.7113839, -81.92324381 | width=100% | height=100% }}  
 
|-
 
|-
| County:
+
| County: [[Morgan County, Ohio|Morgan]]
 
|-
 
|-
| Municipality:
+
| Municipality:  
 
|-
 
|-
| Operator Name:
+
| Operator Name: [[ALTIER J V GAS & OIL]]
 
|-
 
|-
| Well Pad ID:
+
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:
+
| Farm/Lease Name:  
 
|-
 
|-
| First Permit Date:
+
| First Permit Date:  
 
|-
 
|-
| Last Permit Date:
+
| Last Permit Date:  
 
|-
 
|-
 
| Spud Date: 1988-02-25
 
| Spud Date: 1988-02-25
 
|-
 
|-
| Unconventional:
+
| Unconventional: No
 
|-
 
|-
| Horizontal:
+
| Configuration: Vertical
 
|-
 
|-
| Producing: No
+
| Well Status: Producing
 
|-
 
|-
| Violations: 4
+
| Violations: 0
 
|-
 
|-
| Latitude: 39.7113839022
+
| Latitude: 39.7113839
 
|-
 
|-
| Longitude: -81.9232438052
+
| Longitude: -81.92324381
 
|-
 
|-
 
|}
 
|}
Line 43: Line 43:
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
!scope="col" | OIL PRODUCTION DAYS
|}
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | TYPE
 
!scope="col" | QUANTITY
 
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
|}
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | INSPECTION ID
 
!scope="col" | DATE
 
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| -1262785125
+
| 1988-0
| 2012-10-10
+
| style="text-align:right;" | 1660.0
|
+
|
| My inspection this day with Jake Glascock to show him well, inform him of the numerous complaints he may receive. I gave Jake a history of the problems and we did a visual inspection of the recent reclamation, finding it satisfactory. The tank battery looked satisfactory and found no violations.
+
|
|
+
|
|
+
| style="text-align:right;" | 1614.0
|
+
|
 +
|-
 +
|-
 +
| 1989-0
 +
| style="text-align:right;" | 3704.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 1324.0
 +
|
 +
|-
 +
|-
 +
| 1990-0
 +
| style="text-align:right;" | 3762.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 1200.0
 +
|
 +
|-
 +
|-
 +
| 1993-0
 +
| style="text-align:right;" | 2506.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 1994-0
 +
| style="text-align:right;" | 2029.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 386.0
 +
|
 +
|-
 +
|-
 +
| 1995-0
 +
| style="text-align:right;" | 1420.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 216.0
 +
|
 +
|-
 +
|-
 +
| 1996-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 1998-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 2001-0
 +
| style="text-align:right;" | 1083.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 152.0
 +
|
 +
|-
 +
|-
 +
| 2002-0
 +
| style="text-align:right;" | 1291.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 327.0
 +
|
 +
|-
 +
|-
 +
| 2003-0
 +
| style="text-align:right;" | 988.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 210.0
 +
|
 +
|-
 +
|-
 +
| 2004-0
 +
| style="text-align:right;" | 1084.0
 +
|  
 +
|  
 +
|
 +
| style="text-align:right;" | 298.0
 +
|
 +
|-
 +
|-
 +
| 2005-0
 +
| style="text-align:right;" | 497.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 204.0
 +
|
 +
|-
 +
|-
 +
| 2006-0
 +
| style="text-align:right;" | 575.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 503.0
 +
|
 +
|-
 +
|-
 +
| 2007-0
 +
| style="text-align:right;" | 605.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 453.0
 +
|
 +
|-
 +
|-
 +
| 2008-0
 +
| style="text-align:right;" | 724.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 368.0
 +
|  
 
|-
 
|-
 
|-
 
|-
| -151702270
+
| 2009-0
| 2013-07-03
+
| style="text-align:right;" | 666.0
|
+
|  
| Joe Altier has asked me to come out to the tank battery to witness that he has replaced the leaking nipple. I arrived on location and found that he has in fact replaced the nipple and replumbed the lines to the plastic tank underneath the knock out tank. There are no other issues at this time.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 442.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -1672813555
+
| 2010-0
| 2008-05-02
+
| style="text-align:right;" | 2134.0
|
+
|  
| Upon inspecting tank site again for compliance of inspectors request too change out tank and removal of stone beneath tank,job was completed as requested!with no spillage of brine/oil within dike area.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 432.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -2099781883
+
| 2011-0
| 2009-11-17
+
| style="text-align:right;" | 996.0
|
+
|  
| Follow-up on NOV, In-Compliance.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 153.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -2131216568
+
| 2012-0
| 2013-06-12
+
| style="text-align:right;" | 665.0
|
+
|  
| Mrs. Hivnor called and stated the nipple on the tank was leaking brine. When I arrived I found that there was a very small leak coming from the nipple which already had a clamp. Josh Garland was recently at location for the same complaint and had issued a compliance action. I told Joe Altier that they needed to repair or replace the equipment and clean up the contamination. I witnessed the well tender tighten the clamp and clean up the area. Joe said if the nipple still leaks he will replace the part. I will return in a few weeks for a follow-up inspection.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 202.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -2131253285
+
| 2013-0
| 2004-03-02
+
| style="text-align:right;" | 417.0
|
+
|  
| Complaint called in by Deb HIV nor stated there was oil/brine within dike area wanted it cleaned up A.SA.P.arrived on location to meet with well owner Joe Artier to witness cleanup, dike area was flushed with fresh water and loaded in vacuum truck owned by Steve AltierUIC-154photos taken of before and after cleanup.Mr. Hivinor called @8:40 pm and stated approximatly 1qt. Of iol still remained within dike area wants it cleaned up .3-3-04 went by site and took additional photo's of clean up.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 217.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -223977329
+
| 2014-0
| 2012-10-10
+
| style="text-align:right;" | 380.0
|
+
| style="text-align:right;" | 365.0
| I accompanied Cindy VanDyke on the inspection of well. Well is capable of producing and there is a current chart in the meter. There were 2//100 barrel tanks and a 25 barrel separator above a plastic water tank. ID was posted on tank and dike is in good condition.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 146.0
|
+
| style="text-align:right;" | 365.0
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
 +
| accessdate = 2015-06-20 }}</ref>
 +
== Inspection Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | INSPECTION ID
 +
!scope="col" | DATE
 +
!scope="col" | DESCRIPTION
 +
!scope="col" | COMMENT
 +
!scope="col" | VIOLATION ID
 +
!scope="col" | VIOLATION CODE
 +
!scope="col" | VIOLATION COMMENT
 
|-
 
|-
| -548047134
+
| -1262785125
| 2013-08-30
+
| 2012-10-10
|
+
|  
| Joe Altier called me and said they changed out the tank and contamination. The replaced the gravel with fresh stone. I will head out next week to check the location.
+
| My inspection this day with Jake Glascock to show him well, inform him of the numerous complaints he may receive.  I gave Jake a history of the problems and we did a visual inspection of the recent reclamation, finding it satisfactory.  The tank battery looked satisfactory and found no violations.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1325071346
 
| 1325071346
 
| 2013-08-06
 
| 2013-08-06
|
+
|  
 
| Debbie Hivnor called and said she believes the tank is leaking from the bottom. She said they have been digging away the gravel from under the nipple and it accumulates water. It had just rained so it was hard to tell if it was from the tank. I called Joe and he stated they have shut in well and recorded the levels and found no loss in the fluid. Joe does not believe the tank is leaking and we will have to wait until there is a long period of dry weather in order to tell if there is an issue.
 
| Debbie Hivnor called and said she believes the tank is leaking from the bottom. She said they have been digging away the gravel from under the nipple and it accumulates water. It had just rained so it was hard to tell if it was from the tank. I called Joe and he stated they have shut in well and recorded the levels and found no loss in the fluid. Joe does not believe the tank is leaking and we will have to wait until there is a long period of dry weather in order to tell if there is an issue.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1344366223
 
| 1344366223
 
| 2012-08-06
 
| 2012-08-06
|
+
|  
| My inspection this day with Joe Altier found area with brine and oil kill has been reclaimed - contaminated soil removed, Joe says - smoothed ground seeded, fertilized, and mulched - good rain the last day or 2 and should be sprouting very soon.  Joe has replaced the steel flowline with plastic and corrosion inhibitor couplings and this should prevent any further problems.  The dike area was inspected and, due to rains the night before, was found to contain fresh rain water - was no indication of brine and Joe and I discussed the possibility that "the hose could have popped out of the hole in the top" and released brine inside the dike area.  The hose is now tied down and can't possiby slip out.  Joe opened valve on outside of dike and drained the inside of the fresh water.  Identification is complete.  All violations have been resolved.
+
| My inspection this day with Joe Altier found area with brine and oil kill has been reclaimed - contaminated soil removed, Joe says - smoothed ground seeded, fertilized, and mulched - good rain the last day or 2 and should be sprouting very soon.  Joe has replaced the steel flowline with plastic and corrosion inhibitor couplings and this should prevent any further problems.  The dike area was inspected and, due to rains the night before, was found to contain fresh rain water - was no indication of brine and Joe and I discussed the possibility that the hose could have popped out of the hole in the top and released brine inside the dike area.  The hose is now tied down and can't possiby slip out.  Joe opened valve on outside of dike and drained the inside of the fresh water.  Identification is complete.  All violations have been resolved.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1346358722
 
| 1346358722
 
| 2012-08-30
 
| 2012-08-30
|
+
|  
 
| I received a complaint from Debbie Hivnor that grass has not grown back where Joey had reseeded and that there were still bare patches.  I went out and looked with Joey Altier and found there were a couple 2' squares of ground that still did not have a sufficient stand of grass - the big majority of it did.  Considering that he only reseeded about 3 weeks ago and that we did not have rain until the last week, I felt it looked very good.  I know that if another month passed, all the ground would be covered.  Joe said he would go ahead and put more seed down in those patches and also address another area where she felt was too bare.  This 2nd spot is where her cows root around and is understandable that grass has trouble growing.  Joe said he would also plant more there.  I called Debbie and told her that while I did not see a problem with the reclamation the way it was and that if she had waited a month, it would be taken care of,  that Joe was going to re-seed the areas for her.
 
| I received a complaint from Debbie Hivnor that grass has not grown back where Joey had reseeded and that there were still bare patches.  I went out and looked with Joey Altier and found there were a couple 2' squares of ground that still did not have a sufficient stand of grass - the big majority of it did.  Considering that he only reseeded about 3 weeks ago and that we did not have rain until the last week, I felt it looked very good.  I know that if another month passed, all the ground would be covered.  Joe said he would go ahead and put more seed down in those patches and also address another area where she felt was too bare.  This 2nd spot is where her cows root around and is understandable that grass has trouble growing.  Joe said he would also plant more there.  I called Debbie and told her that while I did not see a problem with the reclamation the way it was and that if she had waited a month, it would be taken care of,  that Joe was going to re-seed the areas for her.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1367765004
 
| 1367765004
 
| 2013-05-05
 
| 2013-05-05
|
+
|  
 
| Well equipped with a pumping unit with electric motor. The stuffing box had developed a leak and released a small amount of crude oil  at the well head. The tank battery was equipped with two 100 barrel (Bbl) steel tanks, a 30 Bbl water knock-out not in use, a separator, and a 100 gallon poly tank being used for the annular disposal on another well on the lease. This well is not set up for annular disposal. The nipple on  one of the 100 Bbl tanks had corroded and allowed a small amount of salt water to leach into the dike. There was a band clamp temporarily wrapped around the nipple. The dike was equipped with a drain to release fresh water. There was no sign of contaminated soils near the end of the drain outside of the dike. The water in the dike was field tested with a Quan-tab and found to have greater than 6508 ppm Chloride content. All leaking equipment shall be repaired or replaced. Any contaminated soils shall be removed, and disposed of properly.
 
| Well equipped with a pumping unit with electric motor. The stuffing box had developed a leak and released a small amount of crude oil  at the well head. The tank battery was equipped with two 100 barrel (Bbl) steel tanks, a 30 Bbl water knock-out not in use, a separator, and a 100 gallon poly tank being used for the annular disposal on another well on the lease. This well is not set up for annular disposal. The nipple on  one of the 100 Bbl tanks had corroded and allowed a small amount of salt water to leach into the dike. There was a band clamp temporarily wrapped around the nipple. The dike was equipped with a drain to release fresh water. There was no sign of contaminated soils near the end of the drain outside of the dike. The water in the dike was field tested with a Quan-tab and found to have greater than 6508 ppm Chloride content. All leaking equipment shall be repaired or replaced. Any contaminated soils shall be removed, and disposed of properly.
|
+
|  
| 9-9-05(A)8
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1369842852
 
| 1369842852
 
| 2013-05-29
 
| 2013-05-29
|
+
|  
 
| The stuffing box has been repaired and the operator cleaned up the oil contamination. Well is in compliance.
 
| The stuffing box has been repaired and the operator cleaned up the oil contamination. Well is in compliance.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1377539066
 
| 1377539066
 
| 2013-08-26
 
| 2013-08-26
|
+
|  
 
| Alan Hivnor called and stated that the tank was leaking and he was concerned about his spring water. He said there was standing water in the dike. Upon inspection, I found a puddle with around a quart or less of brine water which appeared to be emanating from the bottom of the tank. I called Joe Altier and told him the only way to know for sure whether or not the brine source is from the tank or trapped in the dike gravel is to remove both. He said he would get a new tank and remove the contamination.
 
| Alan Hivnor called and stated that the tank was leaking and he was concerned about his spring water. He said there was standing water in the dike. Upon inspection, I found a puddle with around a quart or less of brine water which appeared to be emanating from the bottom of the tank. I called Joe Altier and told him the only way to know for sure whether or not the brine source is from the tank or trapped in the dike gravel is to remove both. He said he would get a new tank and remove the contamination.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1378322624
 
| 1378322624
 
| 2013-09-04
 
| 2013-09-04
|
+
|  
 
| Joe has cahnged out the tank, removed the old gravel, and replaced with new gravel. There are no issues at this time.
 
| Joe has cahnged out the tank, removed the old gravel, and replaced with new gravel. There are no issues at this time.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1381801607
 
| 1381801607
 
| 2008-05-01
 
| 2008-05-01
|
+
|  
 
| Complaint received from Allen Hivnor @10:30 pm of oil within dike area at tank site located on his property, he claims  that tank is leaking only when owner heats oil in preparation for shipping, inspected site and found small amount of oil residue located within dike area called well owner J.V. Altier and requested he meet me at site and discuss plans for possibly removing tank and replacing it with a new tank and also replacing stone that is located beneath present tank,decision was made to replace tank and stone at site owner stated job would be complete by 5/2/08.Photo's taken of site 4.
 
| Complaint received from Allen Hivnor @10:30 pm of oil within dike area at tank site located on his property, he claims  that tank is leaking only when owner heats oil in preparation for shipping, inspected site and found small amount of oil residue located within dike area called well owner J.V. Altier and requested he meet me at site and discuss plans for possibly removing tank and replacing it with a new tank and also replacing stone that is located beneath present tank,decision was made to replace tank and stone at site owner stated job would be complete by 5/2/08.Photo's taken of site 4.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -151702270
 +
| 2013-07-03
 +
|
 +
| Joe Altier has asked me to come out to the tank battery to witness that he has replaced the leaking nipple. I arrived on location and found that he has in fact replaced the nipple and replumbed the lines to the plastic tank underneath the knock out tank. There are no other issues at this time.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -1672813555
 +
| 2008-05-02
 +
|
 +
| Upon inspecting tank site again for compliance of inspectors request too change out tank and removal of stone beneath tank,job was completed as requested!with no spillage of brine/oil within dike area.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1978283313
 
| 1978283313
 
| 2009-05-15
 
| 2009-05-15
|
+
|  
 
| An inspection of the well revealed water knock out starting to leak in several places. Oily and brine materials will need cleaned up from water knock out leaking. Rob Stonerock and landowner along on inspection.
 
| An inspection of the well revealed water knock out starting to leak in several places. Oily and brine materials will need cleaned up from water knock out leaking. Rob Stonerock and landowner along on inspection.
|
+
|  
| 9-1-07
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| 1978283313
+
| -2099781883
| 2009-05-15
+
| 2009-11-17
|
+
|  
| An inspection of the well revealed water knock out starting to leak in several places. Oily and brine materials will need cleaned up from water knock out leaking. Rob Stonerock and landowner along on inspection.
+
| Follow-up on NOV, In-Compliance.
|
+
|
| 9-9-05(A)8
+
|
|
+
|
 +
|-
 +
|-
 +
| -2131216568
 +
| 2013-06-12
 +
|
 +
| Mrs. Hivnor called and stated the nipple on the tank was leaking brine. When I arrived I found that there was a very small leak coming from the nipple which already had a clamp. Josh Garland was recently at location for the same complaint and had issued a compliance action. I told Joe Altier that they needed to repair or replace the equipment and clean up the contamination. I witnessed the well tender tighten the clamp and clean up the area. Joe said if the nipple still leaks he will replace the part. I will return in a few weeks for a follow-up inspection.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -2131253285
 +
| 2004-03-02
 +
|
 +
| Complaint called in by Deb HIV nor stated there was oil/brine within dike area wanted it cleaned up A.SA.P.arrived on location to meet with well owner Joe Artier to witness cleanup, dike area was flushed with fresh water and loaded in vacuum truck owned by Steve AltierUIC-154photos taken of before and after cleanup.Mr. Hivinor called @8:40 pm and stated approximatly 1qt. Of iol still remained within dike area wants it cleaned up .3-3-04 went by site and took additional photo's of clean up.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -223977329
 +
| 2012-10-10
 +
|
 +
| I accompanied Cindy VanDyke on the inspection of well. Well is capable of producing and there is a current chart in the meter. There were 2//100 barrel tanks and a 25 barrel separator above a plastic water tank. ID was posted on tank and dike is in good condition.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
| 1978283313
+
| 319664747
| 2009-05-15
+
| 2015-03-16
|
+
|  
| An inspection of the well revealed water knock out starting to leak in several places. Oily and brine materials will need cleaned up from water knock out leaking. Rob Stonerock and landowner along on inspection.
+
| Joe Altier and Debbie Hivnor both called today and stated there was a small leak from a bad union and a heater tube on one of the tanks. He has his well tender out on location repairing the issues this morning.
|
+
|  
| 9-9-05(A)9
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 533072304
 
| 533072304
 
| 2009-07-08
 
| 2009-07-08
|
+
|  
 
| Follow-up on NOV, In-Compliance, company not using water knock out, has been unhooked.
 
| Follow-up on NOV, In-Compliance, company not using water knock out, has been unhooked.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -548047134
 +
| 2013-08-30
 +
|
 +
| Joe Altier called me and said they changed out the tank and contamination. The replaced the gravel with fresh stone. I will head out next week to check the location.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 598822018
 
| 598822018
 
| 2011-04-26
 
| 2011-04-26
|
+
|  
 
| Inspection this day found well producing with jack, tank has good ID's, good  dike, current chart in meter.  Looks very nice.
 
| Inspection this day found well producing with jack, tank has good ID's, good  dike, current chart in meter.  Looks very nice.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| 610655976
 +
| 2015-02-09
 +
|
 +
| This was a tank battery inspection. There are no issues to report at this time.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 818118948
 
| 818118948
 
| 2012-08-01
 
| 2012-08-01
|
+
|  
| I received call from Debbie Hivnor at 6:30 AM on 7/30 that Joe had released brine inside the dike area - said they had called him after discovering it at 10 PM - he said he would be out in morning.  Also stated that there was still an oily spot down in woods from his last "oil spill".  I called Joe and he said they had been out and flushed brine with clean water and removed from inside dike.  Very little - less than a bbl - had spilled out of tank.  Joe said he had a trac-hoe coming on Wed. to finish laying the new flowline that he continues to have leaks in.  He had received information for couplers that stop the corrosion that is causing his leaks.  Joe plans to have line replaced and restoration done by the end of the week.  He plans to removed contaminated soil, seed, mulch and fertilize the area in question and remove all brine from inside the dike.  No violation wrote at this time but instructed Joe what to do.
+
| I received call from Debbie Hivnor at 6:30 AM on 7/30 that Joe had released brine inside the dike area - said they had called him after discovering it at 10 PM - he said he would be out in morning.  Also stated that there was still an oily spot down in woods from his last oil spill.  I called Joe and he said they had been out and flushed brine with clean water and removed from inside dike.  Very little - less than a bbl - had spilled out of tank.  Joe said he had a trac-hoe coming on Wed. to finish laying the new flowline that he continues to have leaks in.  He had received information for couplers that stop the corrosion that is causing his leaks.  Joe plans to have line replaced and restoration done by the end of the week.  He plans to removed contaminated soil, seed, mulch and fertilize the area in question and remove all brine from inside the dike.  No violation wrote at this time but instructed Joe what to do.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| PL9282
 
| PL9282
|
+
|  
|
+
|  
 
| Preliminary Restoration  done information from Data Point
 
| Preliminary Restoration  done information from Data Point
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
 +
| accessdate = 2015-06-20 }}</ref>
 +
== References ==
 +
{{reflist}}
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Wells]]
 
[[Category:Wells]]

Revision as of 23:50, 14 July 2015

Well Details

Well ID: 34-115-24076
Loading map...
County: Morgan
Municipality:
Operator Name: ALTIER J V GAS & OIL
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1988-02-25
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 39.7113839
Longitude: -81.92324381

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1988-0 1660.0 1614.0
1989-0 3704.0 1324.0
1990-0 3762.0 1200.0
1993-0 2506.0 0.0
1994-0 2029.0 386.0
1995-0 1420.0 216.0
1996-0 0.0 0.0
1998-0 0.0 0.0
2001-0 1083.0 152.0
2002-0 1291.0 327.0
2003-0 988.0 210.0
2004-0 1084.0 298.0
2005-0 497.0 204.0
2006-0 575.0 503.0
2007-0 605.0 453.0
2008-0 724.0 368.0
2009-0 666.0 442.0
2010-0 2134.0 432.0
2011-0 996.0 153.0
2012-0 665.0 202.0
2013-0 417.0 217.0
2014-0 380.0 365.0 146.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1262785125 2012-10-10 My inspection this day with Jake Glascock to show him well, inform him of the numerous complaints he may receive. I gave Jake a history of the problems and we did a visual inspection of the recent reclamation, finding it satisfactory. The tank battery looked satisfactory and found no violations.
1325071346 2013-08-06 Debbie Hivnor called and said she believes the tank is leaking from the bottom. She said they have been digging away the gravel from under the nipple and it accumulates water. It had just rained so it was hard to tell if it was from the tank. I called Joe and he stated they have shut in well and recorded the levels and found no loss in the fluid. Joe does not believe the tank is leaking and we will have to wait until there is a long period of dry weather in order to tell if there is an issue.
1344366223 2012-08-06 My inspection this day with Joe Altier found area with brine and oil kill has been reclaimed - contaminated soil removed, Joe says - smoothed ground seeded, fertilized, and mulched - good rain the last day or 2 and should be sprouting very soon. Joe has replaced the steel flowline with plastic and corrosion inhibitor couplings and this should prevent any further problems. The dike area was inspected and, due to rains the night before, was found to contain fresh rain water - was no indication of brine and Joe and I discussed the possibility that the hose could have popped out of the hole in the top and released brine inside the dike area. The hose is now tied down and can't possiby slip out. Joe opened valve on outside of dike and drained the inside of the fresh water. Identification is complete. All violations have been resolved.
1346358722 2012-08-30 I received a complaint from Debbie Hivnor that grass has not grown back where Joey had reseeded and that there were still bare patches. I went out and looked with Joey Altier and found there were a couple 2' squares of ground that still did not have a sufficient stand of grass - the big majority of it did. Considering that he only reseeded about 3 weeks ago and that we did not have rain until the last week, I felt it looked very good. I know that if another month passed, all the ground would be covered. Joe said he would go ahead and put more seed down in those patches and also address another area where she felt was too bare. This 2nd spot is where her cows root around and is understandable that grass has trouble growing. Joe said he would also plant more there. I called Debbie and told her that while I did not see a problem with the reclamation the way it was and that if she had waited a month, it would be taken care of, that Joe was going to re-seed the areas for her.
1367765004 2013-05-05 Well equipped with a pumping unit with electric motor. The stuffing box had developed a leak and released a small amount of crude oil at the well head. The tank battery was equipped with two 100 barrel (Bbl) steel tanks, a 30 Bbl water knock-out not in use, a separator, and a 100 gallon poly tank being used for the annular disposal on another well on the lease. This well is not set up for annular disposal. The nipple on one of the 100 Bbl tanks had corroded and allowed a small amount of salt water to leach into the dike. There was a band clamp temporarily wrapped around the nipple. The dike was equipped with a drain to release fresh water. There was no sign of contaminated soils near the end of the drain outside of the dike. The water in the dike was field tested with a Quan-tab and found to have greater than 6508 ppm Chloride content. All leaking equipment shall be repaired or replaced. Any contaminated soils shall be removed, and disposed of properly.
1369842852 2013-05-29 The stuffing box has been repaired and the operator cleaned up the oil contamination. Well is in compliance.
1377539066 2013-08-26 Alan Hivnor called and stated that the tank was leaking and he was concerned about his spring water. He said there was standing water in the dike. Upon inspection, I found a puddle with around a quart or less of brine water which appeared to be emanating from the bottom of the tank. I called Joe Altier and told him the only way to know for sure whether or not the brine source is from the tank or trapped in the dike gravel is to remove both. He said he would get a new tank and remove the contamination.
1378322624 2013-09-04 Joe has cahnged out the tank, removed the old gravel, and replaced with new gravel. There are no issues at this time.
1381801607 2008-05-01 Complaint received from Allen Hivnor @10:30 pm of oil within dike area at tank site located on his property, he claims that tank is leaking only when owner heats oil in preparation for shipping, inspected site and found small amount of oil residue located within dike area called well owner J.V. Altier and requested he meet me at site and discuss plans for possibly removing tank and replacing it with a new tank and also replacing stone that is located beneath present tank,decision was made to replace tank and stone at site owner stated job would be complete by 5/2/08.Photo's taken of site 4.
-151702270 2013-07-03 Joe Altier has asked me to come out to the tank battery to witness that he has replaced the leaking nipple. I arrived on location and found that he has in fact replaced the nipple and replumbed the lines to the plastic tank underneath the knock out tank. There are no other issues at this time.
-1672813555 2008-05-02 Upon inspecting tank site again for compliance of inspectors request too change out tank and removal of stone beneath tank,job was completed as requested!with no spillage of brine/oil within dike area.
1978283313 2009-05-15 An inspection of the well revealed water knock out starting to leak in several places. Oily and brine materials will need cleaned up from water knock out leaking. Rob Stonerock and landowner along on inspection.
-2099781883 2009-11-17 Follow-up on NOV, In-Compliance.
-2131216568 2013-06-12 Mrs. Hivnor called and stated the nipple on the tank was leaking brine. When I arrived I found that there was a very small leak coming from the nipple which already had a clamp. Josh Garland was recently at location for the same complaint and had issued a compliance action. I told Joe Altier that they needed to repair or replace the equipment and clean up the contamination. I witnessed the well tender tighten the clamp and clean up the area. Joe said if the nipple still leaks he will replace the part. I will return in a few weeks for a follow-up inspection.
-2131253285 2004-03-02 Complaint called in by Deb HIV nor stated there was oil/brine within dike area wanted it cleaned up A.SA.P.arrived on location to meet with well owner Joe Artier to witness cleanup, dike area was flushed with fresh water and loaded in vacuum truck owned by Steve AltierUIC-154photos taken of before and after cleanup.Mr. Hivinor called @8:40 pm and stated approximatly 1qt. Of iol still remained within dike area wants it cleaned up .3-3-04 went by site and took additional photo's of clean up.
-223977329 2012-10-10 I accompanied Cindy VanDyke on the inspection of well. Well is capable of producing and there is a current chart in the meter. There were 2//100 barrel tanks and a 25 barrel separator above a plastic water tank. ID was posted on tank and dike is in good condition.
319664747 2015-03-16 Joe Altier and Debbie Hivnor both called today and stated there was a small leak from a bad union and a heater tube on one of the tanks. He has his well tender out on location repairing the issues this morning.
533072304 2009-07-08 Follow-up on NOV, In-Compliance, company not using water knock out, has been unhooked.
-548047134 2013-08-30 Joe Altier called me and said they changed out the tank and contamination. The replaced the gravel with fresh stone. I will head out next week to check the location.
598822018 2011-04-26 Inspection this day found well producing with jack, tank has good ID's, good dike, current chart in meter. Looks very nice.
610655976 2015-02-09 This was a tank battery inspection. There are no issues to report at this time.
818118948 2012-08-01 I received call from Debbie Hivnor at 6:30 AM on 7/30 that Joe had released brine inside the dike area - said they had called him after discovering it at 10 PM - he said he would be out in morning. Also stated that there was still an oily spot down in woods from his last oil spill. I called Joe and he said they had been out and flushed brine with clean water and removed from inside dike. Very little - less than a bbl - had spilled out of tank. Joe said he had a trac-hoe coming on Wed. to finish laying the new flowline that he continues to have leaks in. He had received information for couplers that stop the corrosion that is causing his leaks. Joe plans to have line replaced and restoration done by the end of the week. He plans to removed contaminated soil, seed, mulch and fertilize the area in question and remove all brine from inside the dike. No violation wrote at this time but instructed Joe what to do.
PL9282 Preliminary Restoration done information from Data Point