X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-015-21514"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-015-21514
 
| Well ID: 37-015-21514
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.934536, -76.194791 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.934536, -76.194792 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Bradford County, Pennsylvania|Bradford]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Warren Township, Bradford County, Pennsylvania|Warren Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[TALISMAN ENERGY USA INC]]
+
| County: [[Bradford_County,_Pennsylvania|Bradford]]
 
|-
 
|-
| Well Pad ID: [[149617|149617]]
+
| Municipality: [[Warren Township,_Bradford_County,_Pennsylvania|Warren Township]]
 
|-
 
|-
| Farm/Lease Name: YOUNG 05 080 01 R
+
| Operator Name: [[REPSOL OIL & GAS USA LLC]]
 
|-
 
|-
| First Permit Date: 2011-01-24
+
| Well Pad ID: [[149617]]
 
|-
 
|-
| Last Permit Date: 2011-01-24
+
| Farm/Lease Name: YOUNG 05 080 01 R
 
|-
 
|-
| Spud Date: 2011-02-13
+
| License Status: Active
 
|-
 
|-
| Unconventional: Yes
+
| Spud Date: 02/13/2011
 
|-
 
|-
| Horizontal: Yes
+
| Permit Date: 1/24/2011
 
|-
 
|-
| Well Status: ACTIVE
+
| Unconventional Well: Y
 
|-
 
|-
| Violations: 0
+
| Configuration: Horizontal Well
 
|-
 
|-
 
| Latitude: 41.934536
 
| Latitude: 41.934536
 
|-
 
|-
| Longitude: -76.194791
+
| Longitude: -76.194792
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2010-2
+
| 2010
| style="text-align:right;" | 0.0
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2011
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-2
+
| 2012
| style="text-align:right;" | 0.0
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 294,063.20
 +
| style="text-align: right;" | 83
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2014
| style="text-align:right;" | 0.0
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 674,264.60
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 360
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 434,616.00
 +
| style="text-align: right;" | 361
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2016
| style="text-align:right;" | 0.0
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 335,682.40
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 327
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 276,537.70
 +
| style="text-align: right;" | 363
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2018
| style="text-align:right;" | 0.0
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 235,092.20
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| 2019
| 2012-2
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 51,613.10
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 88
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
|-
 
|-
 
| 2013-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2013-2
 
| style="text-align:right;" | 294063.2
 
| style="text-align:right;" | 83.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2014-1
 
| style="text-align:right;" | 392856.6
 
| style="text-align:right;" | 178.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2014-2
 
| style="text-align:right;" | 281408.0
 
| style="text-align:right;" | 182.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-02
 
| style="text-align:right;" | 37621.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 42878.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 41104.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
 
| 2011-1
 
| 2011-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 171.0
+
| style="text-align: right;" | 171.00 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 8-0728-0004/013
 
| 8-0728-0004/013
| CHEMUNG COUNTY LANDFILL
 
| LOWMAN
 
| NY
 
|-
 
 
|-
 
|-
 
| 2011-1
 
| 2011-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 112.0
+
| style="text-align: right;" | 58.00 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
| NY31346244
+
| NY # 02S17
| HAKES LANDFILL
 
| PAINTED POST
 
| NY
 
|-
 
 
|-
 
|-
 
| 2011-1
 
| 2011-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 58.0
+
| style="text-align: right;" | 112.00 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
| NY # 02S17
+
| NY31346244
| HYLAND FACILITY ASSOCIATION
 
| ANGELICA
 
| NY
 
|-
 
 
|-
 
|-
 
| 2011-1
 
| 2011-1
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 32.0
+
| style="text-align: right;" | 32.00 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR123D001X
+
| WMGR123SW018
| TERRAQUA RESOURCE MANAGEMENT
 
| WILLIAMSPORT
 
| PA
 
|-
 
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 420.0
+
| style="text-align: right;" | 420.00 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR119
 
| WMGR119
| EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 245.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 1,228.00 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123NC018
 
| WMGR123NC018
| EUREKA RESOURCES STANDING STONE TWP FACILITY
 
|
 
| PA
 
 
|-
 
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 105.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW018
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 245.0
+
| style="text-align: right;" | 618.00 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 320.00 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 100.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2013-2
+
| 2014-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 618.0
+
| style="text-align: right;" | 2,713.98 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
|  
+
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,271.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
|-
+
| 2015-1
| 2013-2
+
| Produced Fluid (in Barrels)
| PRODUCED FLUID
+
| style="text-align: right;" | 104.00 Bbl
| style="text-align:right;" | 105.0
 
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR123D001X
+
| WMGR123
| TERRAQUA RESOURCE MANAGEMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 800.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2014-1
+
| 2015-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 100.0
+
| style="text-align: right;" | 220.00 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR123NC018
+
| WMGR123
| EUREKA RESOURCES STANDING STONE TWP FACILITY
+
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 800.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 508.94 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
| 2014-1
+
| 2016-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 320.0
+
| style="text-align: right;" | 277.36 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123NC010
| HYDRO RECOVERY LP BLOSSBURG FACILITY
+
|-
| BLOSSBURG
+
| 2016-1
| PA
+
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 2,789.74 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|  
 
|-
 
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 627.93 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 2014-1
+
| 2016-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 1,466.61 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 269.69 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 265.13 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 185.48 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 148.21 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2017-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 43.36 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 245.06 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 46.41 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 101.97 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 109.73 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 107.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2017-12
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 324.77 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
+
|
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 125.05 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 144.44 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 94.52 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 44.90 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 95.08 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 121.78 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 201.32 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.31 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.33 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 95.83 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 48.45 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 96.43 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 48.22 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 199.64 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 98.66 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 1965599
 
| 1965599
| 2011-04-05
+
| Primary Facility
 +
| 04/05/2011
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| Saxon 173.  BOPs tested 3/28/11.  Drilling with mud, switching over to invert at kickoff.
 
| Saxon 173.  BOPs tested 3/28/11.  Drilling with mud, switching over to invert at kickoff.
 
+
|-
20 set at 220
+
| 1993905
13 3/8 set at 370  20 bbls returned.
+
| Primary Facility
9 5/8 set at 670  10 bbls returned.
+
| 07/28/2011
 
+
| Routine/Complete Inspection
No show of H2O or gas.
+
| No Violations Noted
 +
| Unable to access well head to inspect. Concrete block with manhole
 +
|-
 +
| 2258940
 +
| Primary Facility
 +
| 04/01/2014
 +
| Complaint Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2268210
 +
| Primary Facility
 +
| 04/30/2014
 +
| Complaint Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2309169
 +
| Primary Facility
 +
| 09/30/2014
 +
| Complaint Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2466974
 +
| Primary Facility
 +
| 2016-03-14
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2467574
 +
| Primary Facility
 +
| 2016-03-21
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2475226
 +
| Primary Facility
 +
| 2016-03-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Shortly upon arrival we met with Tony Baker, Completions Foreman, of Talisman Energy.  Mr. Baker stated the following. "Talisman is in the process of setting up for flowback operations for the Young 3H well and they been waiting for a magnesium ball valve to dissolve in tubing in the wellbore in order to commence flowback of the well.  Hydraulic fracturing operations were completed by Halliburton as of 3/15/16.  Frac plug drill-outs were completed by Basic Well Services on 3/15/16". 
 +
We observed a small area of dark staining on the perimeter earthen berm of the site above a sediment trap.  We also observed a piece of secondary containment liner with spots of dark staining staged on the pad surface next to the pad berm above the sediment trap.  I recorded 0.84 milliSiemens/cm³ conductivity in water on containment behind frac tanks in a tank battery near the pad perimeter berm and top of the fill slope of the site.
 +
|-
 +
| 2626385
 +
| Primary Facility
 +
| 2017-08-01
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On August 1, 2017, the Department conducted a routine inspection at the Repsol Oil and Gas USA LLC, Young R (05-080) well site in Warren Township, Bradford County.  The Department was represented by Andrew Hobbins, Water Quality Specialist.  Nobody was present for Repsol. 
 +
 +
The site sign, E & S plan and weekly inspection logs were on site and available for review.  The site was well vegetated and no major erosion or sedimentation issues were observed.  A small area lacking vegetation with minor erosion was observed at the outlet of the infiltration area.  This is most likely the result of recent heavy rainfall in the area.  The Department recommends repairing and reseeding the area. 
 +
 +
Two wells were in production on the well pad.  The wells were labeled and no bubbling was observed in the well cellar.  Two production tanks and two GPUs were on secondary containment.  The containment structures were observed to be in good condition.  Specific conductivity readings were taken from puddles on the pad and from
 
|-
 
|-
| 1993905
+
| 2816436
| 2011-07-28
+
| Primary Facility
 +
| 2018-12-17
 +
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
| Unable to access well head to inspectConcrete block with manhole
+
| NOT approval.   
 +
I took electrical conductivity readings from pooled water with an Oakton PCSTestr 35.  A puddle on the pad surface returned 0.15 mS/cm.
 +
Air temp 36F.
 +
JLP
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 12/14/2011
 +
| 12/14/2011
 +
| style="text-align: right;" | 5445.00
 +
| style="text-align: right;" | 4,243,008.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="15"| 1
 +
| rowspan="1"| Sand (Proppant)
 +
| rowspan="1"|
 +
| rowspan="1"| Proppant
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 14.56
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="11"| Slick Water
 +
| rowspan="11"| Schlumberger
 +
| rowspan="11"| Acid, Iron Control Agent, Corrosion Inhibitor, Friction Reducer, Scale Inhibitor, Biocide
 +
| Glutaraldehyde
 +
| 111-30-8
 +
| style="text-align: right;" | 25.00
 +
| style="text-align: right;" | 0.00649000
 +
| style="text-align: right;" |
 +
|-
 +
| Trisodium phosphate
 +
| 7601-54-9
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00128000
 +
| style="text-align: right;" |
 +
|-
 +
| Sodium erythorbate
 +
| 6381-77-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00019000
 +
| style="text-align: right;" |
 +
|-
 +
| Aliphatic acids
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" |
 +
|-
 +
| Calcium chloride
 +
| 10043-52-4
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00348000
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrochloric Acid
 
|  
 
|  
 +
| style="text-align: right;" | 28.00
 +
| style="text-align: right;" | 2.41
 +
| style="text-align: right;" |
 +
|-
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00128000
 +
| style="text-align: right;" |
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00012000
 +
| style="text-align: right;" |
 +
|-
 +
| Aliphatic alcohols, ethoxylated #1
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00003000
 +
| style="text-align: right;" |
 +
|-
 +
| Ammonium sulfate
 +
| 7783-20-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Fresh Water
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 +
|
 +
|
 +
| style="text-align: right;" | 78.20
 +
| style="text-align: right;" | 66.41
 +
| style="text-align: right;" |
 
|-
 
|-
| 2309169
+
|- valign="top"
| 2014-09-30
+
| rowspan="1"| * Total Water Volume sources may include fresh water, produced water, and/or recycled water ** Information is based on the maximum potential for concentration and thus the total may be over 100 All component information listed was obtained from the suppli
| No Violations Noted
+
| rowspan="1"|
 +
| rowspan="1"|
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Recycled Produced Water
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" | 21.80
 +
| style="text-align: right;" | 18.48
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 20:39, 13 July 2019

Well Details

Well ID: 37-015-21514
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Warren Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 149617
Farm/Lease Name: YOUNG 05 080 01 R
License Status: Active
Spud Date: 02/13/2011
Permit Date: 1/24/2011
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.934536
Longitude: -76.194792

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2011 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2012 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2013 REPSOL OIL & GAS USA LLC 294,063.20 83 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 674,264.60 360 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 434,616.00 361 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 335,682.40 327 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 276,537.70 363 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 235,092.20 364 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 51,613.10 88 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-1 Drill Cuttings (in Tons) 171.00 Tons LANDFILL 8-0728-0004/013
2011-1 Drill Cuttings (in Tons) 58.00 Tons LANDFILL NY # 02S17
2011-1 Drill Cuttings (in Tons) 112.00 Tons LANDFILL NY31346244
2011-1 Drilling Fluid Waste (in Barrels) 32.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2013-2 Produced Fluid (in Barrels) 420.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-2 Produced Fluid (in Barrels) 245.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-2 Produced Fluid (in Barrels) 1,228.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013-2 Produced Fluid (in Barrels) 105.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013-2 Produced Fluid (in Barrels) 618.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 320.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-1 Produced Fluid (in Barrels) 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014-1 Produced Fluid (in Barrels) 2,713.98 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 1,271.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 104.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-1 Produced Fluid (in Barrels) 800.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-2 Produced Fluid (in Barrels) 800.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 508.94 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016-1 Produced Fluid (in Barrels) RWC 802 277.36 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016-1 Produced Fluid (in Barrels) RWC 802 2,789.74 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 627.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016-2 Produced Fluid (in Barrels) RWC 802 1,466.61 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 269.69 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 265.13 Bbl REUSE (AT WELL PAD)
2017-03 Produced Fluid (in Barrels) RWC 802 185.48 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 148.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-05 Produced Fluid (in Barrels) RWC 802 43.36 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 245.06 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 46.41 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 101.97 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 109.73 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 107.00 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 324.77 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 125.05 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 144.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-03 Produced Fluid (in Barrels) RWC 802 94.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-03 Produced Fluid (in Barrels) RWC 802 44.90 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 95.08 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 121.78 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 201.32 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 47.31 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 47.33 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 95.83 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 48.45 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 96.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-11 Produced Fluid (in Barrels) RWC 802 48.22 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 199.64 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 98.66 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1965599 Primary Facility 04/05/2011 Drilling/Alteration No Violations Noted Saxon 173. BOPs tested 3/28/11. Drilling with mud, switching over to invert at kickoff.
1993905 Primary Facility 07/28/2011 Routine/Complete Inspection No Violations Noted Unable to access well head to inspect. Concrete block with manhole
2258940 Primary Facility 04/01/2014 Complaint Inspection No Violations Noted
2268210 Primary Facility 04/30/2014 Complaint Inspection No Violations Noted
2309169 Primary Facility 09/30/2014 Complaint Inspection No Violations Noted
2466974 Primary Facility 2016-03-14 Routine/Complete Inspection No Violations Noted
2467574 Primary Facility 2016-03-21 Incident- Response to Accident or Event No Violations Noted
2475226 Primary Facility 2016-03-24 Routine/Complete Inspection No Violations Noted Shortly upon arrival we met with Tony Baker, Completions Foreman, of Talisman Energy. Mr. Baker stated the following. "Talisman is in the process of setting up for flowback operations for the Young 3H well and they been waiting for a magnesium ball valve to dissolve in tubing in the wellbore in order to commence flowback of the well. Hydraulic fracturing operations were completed by Halliburton as of 3/15/16. Frac plug drill-outs were completed by Basic Well Services on 3/15/16".

We observed a small area of dark staining on the perimeter earthen berm of the site above a sediment trap. We also observed a piece of secondary containment liner with spots of dark staining staged on the pad surface next to the pad berm above the sediment trap. I recorded 0.84 milliSiemens/cm³ conductivity in water on containment behind frac tanks in a tank battery near the pad perimeter berm and top of the fill slope of the site.

2626385 Primary Facility 2017-08-01 Routine/Complete Inspection No Violations Noted On August 1, 2017, the Department conducted a routine inspection at the Repsol Oil and Gas USA LLC, Young R (05-080) well site in Warren Township, Bradford County. The Department was represented by Andrew Hobbins, Water Quality Specialist. Nobody was present for Repsol.

The site sign, E & S plan and weekly inspection logs were on site and available for review. The site was well vegetated and no major erosion or sedimentation issues were observed. A small area lacking vegetation with minor erosion was observed at the outlet of the infiltration area. This is most likely the result of recent heavy rainfall in the area. The Department recommends repairing and reseeding the area.

Two wells were in production on the well pad. The wells were labeled and no bubbling was observed in the well cellar. Two production tanks and two GPUs were on secondary containment. The containment structures were observed to be in good condition. Specific conductivity readings were taken from puddles on the pad and from

2816436 Primary Facility 2018-12-17 Site Restoration No Violations Noted NOT approval.

I took electrical conductivity readings from pooled water with an Oakton PCSTestr 35. A puddle on the pad surface returned 0.15 mS/cm. Air temp 36F. JLP

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 12/14/2011 12/14/2011 5445.00 4,243,008.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Proppant Quartz 14808-60-7 100.00 14.56
Slick Water Schlumberger Acid, Iron Control Agent, Corrosion Inhibitor, Friction Reducer, Scale Inhibitor, Biocide Glutaraldehyde 111-30-8 25.00 0.00649000
Trisodium phosphate 7601-54-9 5.00 0.00128000
Sodium erythorbate 6381-77-7 100.00 0.00019000
Aliphatic acids 30.00 0.00009000
Calcium chloride 10043-52-4 0.00348000
Hydrochloric Acid 28.00 2.41
Ethylene glycol 107-21-1 5.00 0.00128000
Methanol 67-56-1 40.00 0.00012000
Aliphatic alcohols, ethoxylated #1 30.00 0.00009000
Propargyl alcohol 107-19-7 10.00 0.00003000
Ammonium sulfate 7783-20-2 30.00 0.02
Fresh Water Carrier/Base Fluid 78.20 66.41
* Total Water Volume sources may include fresh water, produced water, and/or recycled water ** Information is based on the maximum potential for concentration and thus the total may be over 100 All component information listed was obtained from the suppli
Recycled Produced Water Carrier/Base Fluid 21.80 18.48

For data sources see[7]

References