X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-113-20053"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-113-20053
 
| Well ID: 37-113-20053
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.559425, -76.639944 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.559425, -76.639944 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 11/03/2010
+
| Spud Date: 2010-11-03
 
|-
 
|-
| Permit Date: 10/22/2010
+
| Permit Date: 2010-10-22
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2011-02-05
 +
| 2011-02-05
 +
| style="text-align: right;" | 7678.00
 +
| style="text-align: right;" | 430584.0
 +
| style="text-align: right;" |
 +
|-
 +
| 2
 +
| 2013-06-25
 +
| 2013-06-30
 +
| style="text-align: right;" | 7678
 +
| style="text-align: right;" | 6,100,420.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="12"| 1
 +
| rowspan="2"| Friction Reducer - Plexslick 921
 +
| rowspan="2"| Pumpco Services
 +
| rowspan="2"| Friction Reducer
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.13
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"|
 +
| rowspan="1"| Base Fluid
 +
| Water
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 87.09
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| Biocide - Plexcide 24L
 +
| rowspan="3"| Pumpco Services
 +
| rowspan="3"| Biocide
 +
| Sodium hydroxide
 +
| 1310-73-2
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione
 +
| 533-74-4
 +
| style="text-align: right;" | 24.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Scale Inhibitor - Greenhib 677
 +
| rowspan="2"| Pumpco Services
 +
| rowspan="2"| Scale Inhibitor
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Salt of phosphono-methylated diamine
 +
|
 +
| style="text-align: right;" | 25.00
 +
| style="text-align: right;" | 0.07
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Plexaid OS-30
 +
| rowspan="2"| Pumpco Services
 +
| rowspan="2"| Oxygen Scavenger
 +
| Ammonium bisulfite
 +
| 10192-30-0
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00460000
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Sand (Proppant)
 +
| rowspan="2"| Pumpco Services
 +
| rowspan="2"| Propping Agent
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.90
 +
| style="text-align: right;" | 12.67
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="8"| 2
 +
| rowspan="1"| Hydrochloric Acid 10-30%
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Acid
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.2
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| BA-40L
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Buffering Agent
 +
| Potassium Carbonate
 +
| 584-08-7
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.0003
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FR-66
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Friction Reducer
 +
| Hydrotreated Light Petroleum Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Provided by Customer
 +
| rowspan="1"| Base Fluid
 +
| Fresh Water
 +
| 0000-00-0
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 99.82
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Gyptron T-390
 +
| rowspan="1"| Champion Technologies
 +
| rowspan="1"| Scale Inhibitor
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.001
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| Bactron K-139
 +
| rowspan="3"| Champion Technologies
 +
| rowspan="3"| Biocide
 +
| Glutaraldehyde
 +
| 111-30-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.002
 +
| style="text-align: right;" | 0
 +
|-
 +
| Quaternary ammonium compounds,<br/> benzyl-C-12-16 alkyldimethyl, chlorides
 +
| 68424-85-1
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.004
 +
| style="text-align: right;" | 0
 +
|-
 +
| Ethanol
 +
| 64-17-5
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.002
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 165: Line 378:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2010-2
+
| 2010-S02
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 595.00 Bbl
 
| style="text-align: right;" | 595.00 Bbl
Line 171: Line 384:
 
| PA0008451
 
| PA0008451
 
|-
 
|-
| 2011-1
+
| 2011-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,071.00 Bbl
 
| style="text-align: right;" | 1,071.00 Bbl
Line 177: Line 390:
 
| PA0008451
 
| PA0008451
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 12.29 Bbl
 
| style="text-align: right;" | 12.29 Bbl
Line 183: Line 396:
 
| WMGR123NC006
 
| WMGR123NC006
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 4,456.00 Bbl
 
| style="text-align: right;" | 4,456.00 Bbl
Line 189: Line 402:
 
|  
 
|  
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Fracturing Fluid Waste (in Tons)
 
| Fracturing Fluid Waste (in Tons)
 
| style="text-align: right;" | 29.91 Tons
 
| style="text-align: right;" | 29.91 Tons
Line 195: Line 408:
 
| WMGR123NC006
 
| WMGR123NC006
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 201: Line 414:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 3,761.00 Bbl
 
| style="text-align: right;" | 3,761.00 Bbl
Line 207: Line 420:
 
|  
 
|  
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 542.31 Bbl
 
| style="text-align: right;" | 542.31 Bbl
Line 213: Line 426:
 
|  
 
|  
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 121.45 Bbl
 
| style="text-align: right;" | 121.45 Bbl
Line 219: Line 432:
 
|  
 
|  
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,074.07 Bbl
 
| style="text-align: right;" | 1,074.07 Bbl
Line 225: Line 438:
 
|  
 
|  
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 763.49 Bbl
 
| style="text-align: right;" | 763.49 Bbl
Line 231: Line 444:
 
|  
 
|  
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 3,650.28 Bbl
 
| style="text-align: right;" | 3,650.28 Bbl
Line 237: Line 450:
 
|  
 
|  
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 40.00 Bbl
 
| style="text-align: right;" | 40.00 Bbl
Line 243: Line 456:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 283.91 Bbl
 
| style="text-align: right;" | 283.91 Bbl
Line 249: Line 462:
 
|  
 
|  
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 258.86 Bbl
 
| style="text-align: right;" | 258.86 Bbl
Line 255: Line 468:
 
|  
 
|  
 
|-
 
|-
| 2017-04
+
| 2017-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 177.43 Bbl
 
| style="text-align: right;" | 177.43 Bbl
Line 261: Line 474:
 
|  
 
|  
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 121.09 Bbl
 
| style="text-align: right;" | 121.09 Bbl
Line 267: Line 480:
 
|  
 
|  
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 95.48 Bbl
 
| style="text-align: right;" | 95.48 Bbl
Line 273: Line 486:
 
|  
 
|  
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 128.56 Bbl
 
| style="text-align: right;" | 128.56 Bbl
Line 279: Line 492:
 
|  
 
|  
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 222.95 Bbl
 
| style="text-align: right;" | 222.95 Bbl
Line 285: Line 498:
 
|  
 
|  
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 120.00 Bbl
 
| style="text-align: right;" | 120.00 Bbl
Line 291: Line 504:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 147.81 Bbl
 
| style="text-align: right;" | 147.81 Bbl
Line 297: Line 510:
 
|  
 
|  
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 75.57 Bbl
 
| style="text-align: right;" | 75.57 Bbl
Line 303: Line 516:
 
|  
 
|  
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 83.09 Bbl
 
| style="text-align: right;" | 83.09 Bbl
Line 309: Line 522:
 
|  
 
|  
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 159.49 Bbl
 
| style="text-align: right;" | 159.49 Bbl
Line 315: Line 528:
 
|  
 
|  
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 140.31 Bbl
 
| style="text-align: right;" | 140.31 Bbl
Line 321: Line 534:
 
|  
 
|  
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 69.30 Bbl
 
| style="text-align: right;" | 69.30 Bbl
Line 327: Line 540:
 
|  
 
|  
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 45.10 Bbl
 
| style="text-align: right;" | 45.10 Bbl
Line 333: Line 546:
 
|  
 
|  
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 53.03 Bbl
 
| style="text-align: right;" | 53.03 Bbl
Line 339: Line 552:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 57.19 Bbl
 
| style="text-align: right;" | 57.19 Bbl
Line 345: Line 558:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 
| style="text-align: right;" | 17.72 Tons
 
| style="text-align: right;" | 17.72 Tons
Line 351: Line 564:
 
| 301358
 
| 301358
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 112.72 Bbl
 
| style="text-align: right;" | 112.72 Bbl
Line 357: Line 570:
 
|  
 
|  
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 83.47 Bbl
 
| style="text-align: right;" | 83.47 Bbl
Line 363: Line 576:
 
|  
 
|  
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 99.37 Bbl
 
| style="text-align: right;" | 99.37 Bbl
Line 369: Line 582:
 
|  
 
|  
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.18 Bbl
 
| style="text-align: right;" | 90.18 Bbl
Line 375: Line 588:
 
|  
 
|  
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 91.85 Bbl
 
| style="text-align: right;" | 91.85 Bbl
Line 381: Line 594:
 
|  
 
|  
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 47.17 Bbl
 
| style="text-align: right;" | 47.17 Bbl
Line 387: Line 600:
 
|  
 
|  
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 86.03 Bbl
 
| style="text-align: right;" | 86.03 Bbl
Line 412: Line 625:
 
| 1928683
 
| 1928683
 
| Primary Facility
 
| Primary Facility
| 11/18/2010
+
| 2010-11-18
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
Line 419: Line 632:
 
| 1940027
 
| 1940027
 
| Primary Facility
 
| Primary Facility
| 12/30/2010
+
| 2010-12-30
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 426: Line 639:
 
| 1945328
 
| 1945328
 
| Primary Facility
 
| Primary Facility
| 11/15/2010
+
| 2010-11-15
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 433: Line 646:
 
| 1945368
 
| 1945368
 
| Primary Facility
 
| Primary Facility
| 11/29/2010
+
| 2010-11-29
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 440: Line 653:
 
| 1953377
 
| 1953377
 
| Primary Facility
 
| Primary Facility
| 03/01/2011
+
| 2011-03-01
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
Line 447: Line 660:
 
| 1965504
 
| 1965504
 
| Primary Facility
 
| Primary Facility
| 04/13/2011
+
| 2011-04-13
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 454: Line 667:
 
| 1971928
 
| 1971928
 
| Primary Facility
 
| Primary Facility
| 05/09/2011
+
| 2011-05-09
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 461: Line 674:
 
| 1979220
 
| 1979220
 
| Primary Facility
 
| Primary Facility
| 06/09/2011
+
| 2011-06-09
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 468: Line 681:
 
| 2029339
 
| 2029339
 
| Primary Facility
 
| Primary Facility
| 12/22/2011
+
| 2011-12-22
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 475: Line 688:
 
| 2032770
 
| 2032770
 
| Primary Facility
 
| Primary Facility
| 01/06/2012
+
| 2012-01-06
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 482: Line 695:
 
| 2048001
 
| 2048001
 
| Primary Facility
 
| Primary Facility
| 02/28/2012
+
| 2012-02-28
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
Line 489: Line 702:
 
| 2052946
 
| 2052946
 
| Primary Facility
 
| Primary Facility
| 03/21/2012
+
| 2012-03-21
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 496: Line 709:
 
| 2181464
 
| 2181464
 
| Primary Facility
 
| Primary Facility
| 07/08/2013
+
| 2013-07-08
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 503: Line 716:
 
| 2311403
 
| 2311403
 
| Primary Facility
 
| Primary Facility
| 10/08/2014
+
| 2014-10-08
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 633: Line 846:
 
| 599692
 
| 599692
 
| 11/18/2010
 
| 11/18/2010
| 12/30/2010
+
| 2010-11-18
 
| 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling
 
| 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling
 
| Administrative
 
| Administrative
Line 641: Line 854:
 
| 599693
 
| 599693
 
| 11/18/2010
 
| 11/18/2010
| 12/30/2010
+
| 2010-11-18
 
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 
| Environmental Health & Safety
 
| Environmental Health & Safety
Line 649: Line 862:
 
| 599694
 
| 599694
 
| 11/18/2010
 
| 11/18/2010
| 12/30/2010
+
| 2010-11-18
 
| 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation.
 
| 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation.
 
| Administrative
 
| Administrative
Line 657: Line 870:
 
| 599695
 
| 599695
 
| 11/18/2010
 
| 11/18/2010
| 12/30/2010
+
| 2010-11-18
 
| 102.4HQBMP - Failure to implement Special Protection BMPs for HQ or EV stream.
 
| 102.4HQBMP - Failure to implement Special Protection BMPs for HQ or EV stream.
 
| Administrative
 
| Administrative
Line 665: Line 878:
 
| 605644
 
| 605644
 
| 03/01/2011
 
| 03/01/2011
| 04/13/2011
+
| 2011-03-01
 
| 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation.
 
| 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation.
 
| Administrative
 
| Administrative
Line 673: Line 886:
 
| 605645
 
| 605645
 
| 03/01/2011
 
| 03/01/2011
| 04/13/2011
+
| 2011-03-01
 
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 
| Environmental Health & Safety
 
| Environmental Health & Safety
Line 681: Line 894:
 
| 605647
 
| 605647
 
| 03/01/2011
 
| 03/01/2011
| 04/13/2011
+
| 2011-03-01
 
| 210H - Failure to properly install the permit number, issued by the department, on a completed well.
 
| 210H - Failure to properly install the permit number, issued by the department, on a completed well.
 
| Administrative
 
| Administrative
Line 689: Line 902:
 
| 633381
 
| 633381
 
| 02/28/2012
 
| 02/28/2012
|  
+
| 2012-02-28
 
| 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days
 
| 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days
 
| Administrative
 
| Administrative
Line 814: Line 1,027:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 02/05/2011
 
| 02/05/2011
 
| style="text-align: right;" | 7678.00
 
| style="text-align: right;" | 430584.0
 
| style="text-align: right;" |
 
|-
 
| 2
 
| 06/25/2013
 
| 06/30/2013
 
| style="text-align: right;" | 7678
 
| style="text-align: right;" | 6,100,420.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="12"| 1
 
| rowspan="2"| Friction Reducer - Plexslick 921
 
| rowspan="2"| Pumpco Services
 
| rowspan="2"| Friction Reducer
 
| Distillates, petroleum, hydrotreated light
 
| 64742-47-8
 
| style="text-align: right;" |
 
| style="text-align: right;" | 0.13
 
| style="text-align: right;" |
 
|-
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"|
 
| rowspan="1"| Base Fluid
 
| Water
 
|
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 87.09
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="3"| Biocide - Plexcide 24L
 
| rowspan="3"| Pumpco Services
 
| rowspan="3"| Biocide
 
| Sodium hydroxide
 
| 1310-73-2
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
| Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione
 
| 533-74-4
 
| style="text-align: right;" | 24.00
 
| style="text-align: right;" | 0.02
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| Scale Inhibitor - Greenhib 677
 
| rowspan="2"| Pumpco Services
 
| rowspan="2"| Scale Inhibitor
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
| Salt of phosphono-methylated diamine
 
|
 
| style="text-align: right;" | 25.00
 
| style="text-align: right;" | 0.07
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| Plexaid OS-30
 
| rowspan="2"| Pumpco Services
 
| rowspan="2"| Oxygen Scavenger
 
| Ammonium bisulfite
 
| 10192-30-0
 
| style="text-align: right;" |
 
| style="text-align: right;" | 0.00460000
 
| style="text-align: right;" |
 
|-
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| Sand (Proppant)
 
| rowspan="2"| Pumpco Services
 
| rowspan="2"| Propping Agent
 
| Quartz
 
| 14808-60-7
 
| style="text-align: right;" | 99.90
 
| style="text-align: right;" | 12.67
 
| style="text-align: right;" |
 
|-
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="8"| 2
 
| rowspan="1"| Hydrochloric Acid 10-30%
 
| rowspan="1"| Halliburton
 
| rowspan="1"| Acid
 
| Hydrochloric Acid
 
| 7647-01-0
 
| style="text-align: right;" | 30
 
| style="text-align: right;" | 0.2
 
| style="text-align: right;" | 0
 
|-
 
|- valign="top"
 
| rowspan="1"| BA-40L
 
| rowspan="1"| Halliburton
 
| rowspan="1"| Buffering Agent
 
| Potassium Carbonate
 
| 584-08-7
 
| style="text-align: right;" | 60
 
| style="text-align: right;" | 0.0003
 
| style="text-align: right;" | 0
 
|-
 
|- valign="top"
 
| rowspan="1"| FR-66
 
| rowspan="1"| Halliburton
 
| rowspan="1"| Friction Reducer
 
| Hydrotreated Light Petroleum Distillate
 
| 64742-47-8
 
| style="text-align: right;" | 30
 
| style="text-align: right;" | 0.02
 
| style="text-align: right;" | 0
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"| Provided by Customer
 
| rowspan="1"| Base Fluid
 
| Fresh Water
 
| 0000-00-0
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 99.82
 
| style="text-align: right;" | 0
 
|-
 
|- valign="top"
 
| rowspan="1"| Gyptron T-390
 
| rowspan="1"| Champion Technologies
 
| rowspan="1"| Scale Inhibitor
 
| Methanol
 
| 67-56-1
 
| style="text-align: right;" | 10
 
| style="text-align: right;" | 0.001
 
| style="text-align: right;" | 0
 
|-
 
|- valign="top"
 
| rowspan="3"| Bactron K-139
 
| rowspan="3"| Champion Technologies
 
| rowspan="3"| Biocide
 
| Glutaraldehyde
 
| 111-30-8
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.002
 
| style="text-align: right;" | 0
 
|-
 
| Quaternary ammonium compounds, benzyl-C-12-16 alkyldimethyl, chlorides
 
| 68424-85-1
 
| style="text-align: right;" | 10
 
| style="text-align: right;" | 0.004
 
| style="text-align: right;" | 0
 
|-
 
| Ethanol
 
| 64-17-5
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.002
 
| style="text-align: right;" | 0
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 06:25, 2 August 2019

Well Details

Well ID: 37-113-20053
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Elkland Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 146782
Farm/Lease Name: HEMLOCK HUNTING CLUB UNIT 1H
License Status: Active
Spud Date: 2010-11-03
Permit Date: 2010-10-22
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.559425
Longitude: -76.639944

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-02-05 2011-02-05 7678.00 430584.0
2 2013-06-25 2013-06-30 7678 6,100,420.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Friction Reducer - Plexslick 921 Pumpco Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.13
Water Base Fluid Water 100.00 87.09
Biocide - Plexcide 24L Pumpco Services Biocide Sodium hydroxide 1310-73-2
Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione 533-74-4 24.00 0.02
Scale Inhibitor - Greenhib 677 Pumpco Services Scale Inhibitor
Salt of phosphono-methylated diamine 25.00 0.07
Plexaid OS-30 Pumpco Services Oxygen Scavenger Ammonium bisulfite 10192-30-0 0.00460000
Sand (Proppant) Pumpco Services Propping Agent Quartz 14808-60-7 99.90 12.67
2 Hydrochloric Acid 10-30% Halliburton Acid Hydrochloric Acid 7647-01-0 30 0.2 0
BA-40L Halliburton Buffering Agent Potassium Carbonate 584-08-7 60 0.0003 0
FR-66 Halliburton Friction Reducer Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.02 0
Water Provided by Customer Base Fluid Fresh Water 0000-00-0 100 99.82 0
Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 10 0.001 0
Bactron K-139 Champion Technologies Biocide Glutaraldehyde 111-30-8 5 0.002 0
Quaternary ammonium compounds,
benzyl-C-12-16 alkyldimethyl, chlorides
68424-85-1 10 0.004 0
Ethanol 64-17-5 5 0.002 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 3,230,206.00 284 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 2,542,360.76 364 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,700,522.93 302 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 1,448,011.25 361 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 1,287,031.12 363 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 275,941.46 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-S02 Drilling Fluid Waste (in Barrels) 595.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011-S01 Fracing Fluid Waste (in Barrels) 1,071.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2013-S01 Fracing Fluid Waste (in Barrels) 12.29 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2013-S02 Fracing Fluid Waste (in Barrels) 4,456.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracturing Fluid Waste (in Tons) 29.91 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2014-S01 Fracing Fluid Waste (in Barrels) 60.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S01 Produced Fluid (in Barrels) 3,761.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 542.31 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 121.45 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 1,074.07 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 763.49 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 3,650.28 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M02 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-M02 Produced Fluid (in Barrels) RWC 802 283.91 Bbl REUSE (AT WELL PAD)
2017-M03 Produced Fluid (in Barrels) RWC 802 258.86 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 177.43 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 121.09 Bbl REUSE (AT WELL PAD)
2017-M06 Produced Fluid (in Barrels) RWC 802 95.48 Bbl REUSE (AT WELL PAD)
2017-M07 Produced Fluid (in Barrels) RWC 802 128.56 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 222.95 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-M10 Produced Fluid (in Barrels) RWC 802 147.81 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 75.57 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 83.09 Bbl REUSE (AT WELL PAD)
2018-M01 Produced Fluid (in Barrels) RWC 802 159.49 Bbl REUSE (AT WELL PAD)
2018-M02 Produced Fluid (in Barrels) RWC 802 140.31 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 69.30 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 45.10 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 53.03 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 57.19 Bbl REUSE (AT WELL PAD)
2018-M07 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 17.72 Tons LANDFILL 301358
2018-M08 Produced Fluid (in Barrels) RWC 802 112.72 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 83.47 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 99.37 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 90.18 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 91.85 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 47.17 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 86.03 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1928683 Primary Facility 2010-11-18 Routine/Complete Inspection Violation(s) Noted
1940027 Primary Facility 2010-12-30 Follow-up Inspection No Violations Noted
1945328 Primary Facility 2010-11-15 Drilling/Alteration No Violations Noted
1945368 Primary Facility 2010-11-29 Drilling/Alteration No Violations Noted
1953377 Primary Facility 2011-03-01 Routine/Complete Inspection Violation(s) Noted
1965504 Primary Facility 2011-04-13 Routine/Complete Inspection No Violations Noted
1971928 Primary Facility 2011-05-09 Routine/Partial Inspection No Violations Noted
1979220 Primary Facility 2011-06-09 Routine/Complete Inspection No Violations Noted cellar filled in, well has been fraced, several tanks on site - not on containment, E&S looks good but no berms around pad
2029339 Primary Facility 2011-12-22 Routine/Complete Inspection No Violations Noted
2032770 Primary Facility 2012-01-06 Follow-up Inspection No Violations Noted
2048001 Primary Facility 2012-02-28 Follow-up Inspection Violation(s) Noted
2052946 Primary Facility 2012-03-21 Follow-up Inspection No Violations Noted
2181464 Primary Facility 2013-07-08 Routine/Complete Inspection No Violations Noted
2311403 Primary Facility 2014-10-08 Routine/Complete Inspection No Violations Noted
2464889 Primary Facility 2016-03-16 Site Restoration No Violations Noted
2519597 Primary Facility 2016-09-16 Routine/Complete Inspection No Violations Noted Routine inspection to assess site conditions during well completion activities. Well completion activities have stopped, and crews are breaking down the euqipment. All equipment and chemicals on site were within containment, and signs of spills to containment were observed. Further, no evidence of spills on the pad surface such as staining or odors were observed.

No violations were cited during this inspection.

2525828 Primary Facility 2016-10-06 Routine/Complete Inspection No Violations Noted Routine inspection to assess site conditions after well completions. A coil-tubing rig was on site, and work was underway to connect the wells to the separator units and pipeline.

Overall site conditions were good. All equipement and chemicals on site were within containment. The electrical conductivity of several puddles on the well pad surface was screened and generally ranged from 700 - 1,000 uS/cm. However, one puddle located adjacent to the containment for the produced water tanks was screened at 5.2 mS/cm.

The puddle with the elevated conductivity was approximately 3 feet wide and 10 feet long. A piece of discarded containment was in the puddle. I informed the on-site Chief representative, Gil, of my findings and recommended that the puddle be removed. A sample of this puddle was taken for SAC 942 analysis.

The elevated conductivity in this puddle could be indicative of a release of produced water, flowback fluids, or frac fluids. A release of such fluids to the pad or ground surface would consti

2539105 Primary Facility 2016-11-22 Routine/Complete Inspection No Violations Noted Arrived @ 12:00. Weather: cold, windy, clouds. Chief environmental specialist Aaron Stredny was onsite checking puddle conductivites at the time of my inspection. Wells that had been fracced ¿ 2 months ago were in production and pad liner/containment had recently been removed. Two banks of Baker tanks were onsite. Stredney said that the plan was to store brine prior to the Blanchard frac, scheduled for December 9. There were 5 wells in production on location. Annular vents were plumbed to polytanks.

HHC 1H: top gauge 1700 psi (0-5000), 5-1/2”: 1700 psi, HHC 2H top gauge 1600 psi (0-5000), 5-1/2”: 1600 psi HHC 3H: top gauge 2400 psi (0-5000), 5-1/2”: 2400 psi, HHC 4H top gauge 1600 psi (0-5000), 5-1/2”: 1600 psi HHC 5H top gauge 2150 psi (0-5000), 5-1/2”: 2150 psi There were no violations noted at the time of this inspection. Left location @ 12:20

2539791 Primary Facility 2016-11-22 Follow-up Inspection Violation(s) Noted

Follow-up inspection conducted after receiving laboratory analysis of fluid samples collected during the last inspection (Inspection ID No. 2525835, October 06, 2016).

During the October 06, 2016 inspection, fluid samples were collected from a puddle on the well pad in response to field electrical conductivity readings of 5.2 mS/cm. The puddle was located near the northeast edge of the well pad in front of the produced water tanks. No sheen was present on the puddle, and no staining or odors were observed. Chief was notified of these findings, and had indicated to the Department of Environmental Protection (DEP) all puddles on the pad had been vacuumed up and removed. The laboratory analysis (SAC 942) indicates elevated levels of chlorides (3,598.8 mg/L), strontium (44,490 ug/L), iron (109.2 mg/L), and total dissolved solids (3,994 mg/L). Elevated levels of these constituents suggest that a release of produced water or flowback likely occurred on the well site.

2564298 Primary Facility 2017-02-23 Routine/Complete Inspection No Violations Noted No violations cited.
2581969 Primary Facility 2016-11-22 Routine/Complete Inspection No Violations Noted Arrived @ 11:20. Weather: hot, sunny. There were 5 wells in production on location. Annular vents were plumbed to polytanks.

HHC 1H: top gauge 1200 psi (0-5000), 5-1/2”: 1200 psi, HHC 2H top gauge 1300 psi (0-5000), 5-1/2”: 1300 psi HHC 3H: top gauge 1400 psi (0-5000), 5-1/2”: 1000 psi, HHC 4H top gauge ¿ 400psi (0-5000) – could be a problem with this gauge. 5-1/2”: 1200 psi HHC 5H top gauge 900 psi (0-5000), 5-1/2”: 1500 psi Annuli were plumbed to 550-gallon polytanks which were monitored for methane (Altair 5x gas meter calibrated 4/11/17). No methane was detected. There were no violations noted at the time of this inspection. Left location @ 11:40.

2598265 Primary Facility 2017-05-26 Routine/Complete Inspection No Violations Noted Five wells in production phase. Five separators within plastic containment. No leaks detected. Site stable. No violations noted.
2710682 Primary Facility 2018-03-23 Routine/Complete Inspection No Violations Noted Arrived at 14:00. Weather sunny. 5 wells in production. Annuli were plumbed to 550-gallon polytanks which were monitored for methane (Altair 5x gas meter calibrated 3/23/18). No methane was detected. There were no violations noted at the time of this inspection
2735992 Primary Facility 2018-05-31 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected A T-fitting failed on a separator which resulted in 20 gallons of brine to be released to the pad surface. The operator had a vacuum truck on location the night of the failure for clean-up. The next day, on 5/31 the operator began excavating affected soil and rock on the pad surface. The removed material was placed within roll-off containers. Violation noted but immediately corrected.
2736607 Primary Facility 2018-06-01 Follow-up Inspection No Violations Noted
2752673 Primary Facility 2018-07-17 Site Restoration No Violations Noted Five wells staged for production phase. Five water separators. No leaks detected from production equipment. No violations noted.

The eSubmission Post Drilling Site Restoration Report was submitted to the DEP on 7/13/2018. Based on this inspection report the Post Drilling Restoration report was returned on 7/17/2018.

Returned due to the remaining installation of silt sock.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1928683 599692 11/18/2010 2010-11-18 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative
1928683 599693 11/18/2010 2010-11-18 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1928683 599694 11/18/2010 2010-11-18 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative
1928683 599695 11/18/2010 2010-11-18 102.4HQBMP - Failure to implement Special Protection BMPs for HQ or EV stream. Administrative
1953377 605644 03/01/2011 2011-03-01 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative
1953377 605645 03/01/2011 2011-03-01 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1953377 605647 03/01/2011 2011-03-01 210H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
2048001 633381 02/28/2012 2012-02-28 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative (9x5) Annulus
2539791 773151 2016-11-22 2017-02-23 CSL 402(b) Environmental Health & Safety
2539791 773152 2016-11-22 2017-02-23 91.33(A) Environmental Health & Safety
2539791 773154 2016-11-22 2017-02-23 91.34(A) Environmental Health & Safety
2539791 773155 2016-11-22 2017-02-23 78.56(a) Environmental Health & Safety
2539791 773156 2016-11-22 2017-02-23 SWMA 301 Environmental Health & Safety
2735992 818074 2018-05-31 2018-05-31 CSL 402(b) Environmental Health & Safety
2735992 818075 2018-05-31 2018-05-31 78a54 Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
773151 348993 NOV - Notice of Violation 2017-02-23
773152 348993 NOV - Notice of Violation 2017-02-23
773154 348993 NOV - Notice of Violation 2017-02-23
773155 348993 NOV - Notice of Violation 2017-02-23
773156 348993 NOV - Notice of Violation 2017-02-23

For data sources see[7]

References