If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-113-20053 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.559425,"lon":-76.639944,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Sullivan | |
Municipality: Elkland Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 146782 | |
Farm/Lease Name: HEMLOCK HUNTING CLUB UNIT 1H | |
License Status: | |
Spud Date: 2010-11-12 | |
Permit Date: 2010-10-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.559425 | |
Longitude: -76.639944 |
Date | Event |
---|---|
2010-10-22 | New Permit Application |
2010-11-03 | Performed Spud Operation |
2010-12-03 | Drilling Completion |
2011-02-05 | Perforation |
2011-03-17 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-02-05 | 2011-02-05 | 7,678 | 430,584 | |
2 | 2013-06-25 | 2013-06-30 | 7,678 | 6,100,420 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Friction Reducer - Plexslick 921 | Pumpco Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.13 | ||
Water | Base Fluid | Water | 100.00 | 87.09 | ||||
Biocide - Plexcide 24L | Pumpco Services | Biocide | Sodium hydroxide | 1310-73-2 | ||||
Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione | 533-74-4 | 24.00 | 0.02 | |||||
Scale Inhibitor - Greenhib 677 | Pumpco Services | Scale Inhibitor | ||||||
Salt of phosphono-methylated diamine | 25.00 | 0.07 | ||||||
Plexaid OS-30 | Pumpco Services | Oxygen Scavenger | Ammonium bisulfite | 10192-30-0 | 0.00460000 | |||
Sand (Proppant) | Pumpco Services | Propping Agent | Quartz | 14808-60-7 | 99.90 | 12.67 | ||
2 | Hydrochloric Acid 10-30% | Halliburton | Acid | Hydrochloric Acid | 7647-01-0 | 30 | 0.2 | 0 |
BA-40L | Halliburton | Buffering Agent | Potassium Carbonate | 584-08-7 | 60 | 0.0003 | 0 | |
FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.02 | 0 | |
Water | Provided by Customer | Base Fluid | Fresh Water | 0000-00-0 | 100 | 99.82 | 0 | |
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 10 | 0.001 | 0 | |
Bactron K-139 | Champion Technologies | Biocide | Glutaraldehyde | 111-30-8 | 5 | 0.002 | 0 | |
Quaternary ammonium compounds, benzyl-C-12-16 alkyldimethyl, chlorides |
68424-85-1 | 10 | 0.004 | 0 | ||||
Ethanol | 64-17-5 | 5 | 0.002 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 3,230,206.00 | 284 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 2,542,360.76 | 364 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 1,700,522.93 | 302 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 1,448,011.25 | 361 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 1,287,031.12 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 1,060,987.18 | 343 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 595.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 1,071.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2013 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 4,456.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 12.29 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2013 | CHIEF OIL & GAS LLC | Fracturing Fluid Waste | 29.91 Tons | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2014 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 60.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 4,303.31 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 1,195.52 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 4,413.77 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 750.70 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 1,594.75 Bbl | REUSE (AT WELL PAD) | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 160.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | CHIEF OIL & GAS LLC | Soil Contaminated by Oil & Gas Related Spills | 17.72 Tons | LANDFILL | 301358 |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 1,002.02 Bbl | REUSE (AT WELL PAD) | |
2018 | CHIEF OIL & GAS LLC | Soil Contaminated by Oil | 17.72 Tons | LANDFILL | 301358 |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 1,182.49 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1928683 | Primary Facility | 2010-11-18 | Routine/Complete Inspection | Violation(s) Noted | |
1940027 | Primary Facility | 2010-12-30 | Follow-up Inspection | No Violations Noted | |
1945328 | Primary Facility | 2010-11-15 | Drilling/Alteration | No Violations Noted | |
1945368 | Primary Facility | 2010-11-29 | Drilling/Alteration | No Violations Noted | |
1953377 | Primary Facility | 2011-03-01 | Routine/Complete Inspection | Violation(s) Noted | |
1965504 | Primary Facility | 2011-04-13 | Routine/Complete Inspection | No Violations Noted | |
1971928 | Primary Facility | 2011-05-09 | Routine/Partial Inspection | No Violations Noted | |
1979220 | Primary Facility | 2011-06-09 | Routine/Complete Inspection | No Violations Noted | cellar filled in, well has been fraced, several tanks on site - not on containment, E&S looks good but no berms around pad |
2029339 | Primary Facility | 2011-12-22 | Routine/Complete Inspection | No Violations Noted | |
2032770 | Primary Facility | 2012-01-06 | Follow-up Inspection | No Violations Noted | |
2048001 | Primary Facility | 2012-02-28 | Follow-up Inspection | Violation(s) Noted | |
2052946 | Primary Facility | 2012-03-21 | Follow-up Inspection | No Violations Noted | |
2181464 | Primary Facility | 2013-07-08 | Routine/Complete Inspection | No Violations Noted | |
2311403 | Primary Facility | 2014-10-08 | Routine/Complete Inspection | No Violations Noted | |
2464889 | Primary Facility | 2016-03-16 | Site Restoration | No Violations Noted | |
2519597 | Primary Facility | 2016-09-16 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess site conditions during well completion activities. Well completion activities have stopped, and crews are breaking down the euqipment. All equipment and chemicals on site were within containment, and signs of spills to containment were observed. Further, no evidence of spills on the pad surface such as staining or odors were observed.
No violations were cited during this inspection. |
2525828 | Primary Facility | 2016-10-06 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess site conditions after well completions. A coil-tubing rig was on site, and work was underway to connect the wells to the separator units and pipeline.
Overall site conditions were good. All equipement and chemicals on site were within containment. The electrical conductivity of several puddles on the well pad surface was screened and generally ranged from 700 - 1,000 uS/cm. However, one puddle located adjacent to the containment for the produced water tanks was screened at 5.2 mS/cm. The puddle with the elevated conductivity was approximately 3 feet wide and 10 feet long. A piece of discarded containment was in the puddle. I informed the on-site Chief representative, Gil, of my findings and recommended that the puddle be removed. A sample of this puddle was taken for SAC 942 analysis. The elevated conductivity in this puddle could be indicative of a release of produced water, flowback fluids, or frac fluids. A release of such fluids to the pad or ground surface would consti |
2539105 | Primary Facility | 2016-11-22 | Routine/Complete Inspection | No Violations Noted | Arrived @ 12:00. Weather: cold, windy, clouds. Chief environmental specialist Aaron Stredny was onsite checking puddle conductivites at the time of my inspection. Wells that had been fracced ¿ 2 months ago were in production and pad liner/containment had recently been removed. Two banks of Baker tanks were onsite. Stredney said that the plan was to store brine prior to the Blanchard frac, scheduled for December 9. There were 5 wells in production on location. Annular vents were plumbed to polytanks.
HHC 1H: top gauge 1700 psi (0-5000), 5-1/2”: 1700 psi, HHC 2H top gauge 1600 psi (0-5000), 5-1/2”: 1600 psi HHC 3H: top gauge 2400 psi (0-5000), 5-1/2”: 2400 psi, HHC 4H top gauge 1600 psi (0-5000), 5-1/2”: 1600 psi HHC 5H top gauge 2150 psi (0-5000), 5-1/2”: 2150 psi There were no violations noted at the time of this inspection. Left location @ 12:20 |
2539791 | Primary Facility | 2016-11-22 | Follow-up Inspection | Violation(s) Noted |
Follow-up inspection conducted after receiving laboratory analysis of fluid samples collected during the last inspection (Inspection ID No. 2525835, October 06, 2016). During the October 06, 2016 inspection, fluid samples were collected from a puddle on the well pad in response to field electrical conductivity readings of 5.2 mS/cm. The puddle was located near the northeast edge of the well pad in front of the produced water tanks. No sheen was present on the puddle, and no staining or odors were observed. Chief was notified of these findings, and had indicated to the Department of Environmental Protection (DEP) all puddles on the pad had been vacuumed up and removed. The laboratory analysis (SAC 942) indicates elevated levels of chlorides (3,598.8 mg/L), strontium (44,490 ug/L), iron (109.2 mg/L), and total dissolved solids (3,994 mg/L). Elevated levels of these constituents suggest that a release of produced water or flowback likely occurred on the well site. |
2564298 | Primary Facility | 2017-02-23 | Routine/Complete Inspection | No Violations Noted | No violations cited. |
2581969 | Primary Facility | 2016-11-22 | Routine/Complete Inspection | No Violations Noted | Arrived @ 11:20. Weather: hot, sunny. There were 5 wells in production on location. Annular vents were plumbed to polytanks.
HHC 1H: top gauge 1200 psi (0-5000), 5-1/2”: 1200 psi, HHC 2H top gauge 1300 psi (0-5000), 5-1/2”: 1300 psi HHC 3H: top gauge 1400 psi (0-5000), 5-1/2”: 1000 psi, HHC 4H top gauge ¿ 400psi (0-5000) – could be a problem with this gauge. 5-1/2”: 1200 psi HHC 5H top gauge 900 psi (0-5000), 5-1/2”: 1500 psi Annuli were plumbed to 550-gallon polytanks which were monitored for methane (Altair 5x gas meter calibrated 4/11/17). No methane was detected. There were no violations noted at the time of this inspection. Left location @ 11:40. |
2598265 | Primary Facility | 2017-05-26 | Routine/Complete Inspection | No Violations Noted | Five wells in production phase. Five separators within plastic containment. No leaks detected. Site stable. No violations noted. |
2710682 | Primary Facility | 2018-03-23 | Routine/Complete Inspection | No Violations Noted | Arrived at 14:00. Weather sunny. 5 wells in production. Annuli were plumbed to 550-gallon polytanks which were monitored for methane (Altair 5x gas meter calibrated 3/23/18). No methane was detected. There were no violations noted at the time of this inspection |
2735992 | Primary Facility | 2018-05-31 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | A T-fitting failed on a separator which resulted in 20 gallons of brine to be released to the pad surface. The operator had a vacuum truck on location the night of the failure for clean-up. The next day, on 5/31 the operator began excavating affected soil and rock on the pad surface. The removed material was placed within roll-off containers. Violation noted but immediately corrected. |
2736607 | Primary Facility | 2018-06-01 | Follow-up Inspection | No Violations Noted | |
2752673 | Primary Facility | 2018-07-17 | Site Restoration | No Violations Noted | Five wells staged for production phase. Five water separators. No leaks detected from production equipment. No violations noted.
The eSubmission Post Drilling Site Restoration Report was submitted to the DEP on 7/13/2018. Based on this inspection report the Post Drilling Restoration report was returned on 7/17/2018. Returned due to the remaining installation of silt sock. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1928683 | 599692 | 11/18/2010 | 2010-11-18 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
1928683 | 599693 | 11/18/2010 | 2010-11-18 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1928683 | 599694 | 11/18/2010 | 2010-11-18 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Administrative | |
1928683 | 599695 | 11/18/2010 | 2010-11-18 | 102.4HQBMP - Failure to implement Special Protection BMPs for HQ or EV stream. | Administrative | |
1953377 | 605644 | 03/01/2011 | 2011-03-01 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Administrative | |
1953377 | 605645 | 03/01/2011 | 2011-03-01 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1953377 | 605647 | 03/01/2011 | 2011-03-01 | 210H - Failure to properly install the permit number, issued by the department, on a completed well. | Administrative | |
2048001 | 633381 | 02/28/2012 | 2012-02-28 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | (9x5) Annulus |
2539791 | 773151 | 2016-11-22 | 2017-02-23 | CSL 402(b) | Environmental Health & Safety | |
2539791 | 773152 | 2016-11-22 | 2017-02-23 | 91.33(A) | Environmental Health & Safety | |
2539791 | 773154 | 2016-11-22 | 2017-02-23 | 91.34(A) | Environmental Health & Safety | |
2539791 | 773155 | 2016-11-22 | 2017-02-23 | 78.56(a) | Environmental Health & Safety | |
2539791 | 773156 | 2016-11-22 | 2017-02-23 | SWMA 301 | Environmental Health & Safety | |
2735992 | 818074 | 2018-05-31 | 2018-05-31 | CSL 402(b) | Environmental Health & Safety | |
2735992 | 818075 | 2018-05-31 | 2018-05-31 | 78a54 | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
773151 | 348993 | NOV - Notice of Violation | 2017-02-23 | ||||
773152 | 348993 | NOV - Notice of Violation | 2017-02-23 | ||||
773154 | 348993 | NOV - Notice of Violation | 2017-02-23 | ||||
773155 | 348993 | NOV - Notice of Violation | 2017-02-23 | ||||
773156 | 348993 | NOV - Notice of Violation | 2017-02-23 |
For data sources see[8]