If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-115-20646 | | Well ID: 37-115-20646 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.684072, -75.647581 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Plugged OG Well | | License Status: Plugged OG Well | ||
|- | |- | ||
− | | Spud Date: 09 | + | | Spud Date: 2011-09-20 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2011-08-31 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2013-06-03 | ||
+ | | 2013-06-04 | ||
+ | | style="text-align: right;" | 7572 | ||
+ | | style="text-align: right;" | 1,654,420.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="21"| 1 | ||
+ | | rowspan="1"| White 30/50 | ||
+ | | rowspan="1"| Trican | ||
+ | | rowspan="1"| Proppant | ||
+ | | Crystalline silica: Quartz (SiO2) | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 8.02715 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Customer | ||
+ | | rowspan="1"| Carrier | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 89.71 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| SI-7 (Scale Inhibitor) | ||
+ | | rowspan="1"| Trican | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00961 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 15% HCL | ||
+ | | rowspan="1"| Trican | ||
+ | | rowspan="1"| Carrier | ||
+ | | Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.1407 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 100 Mesh, Bulk (over 20K lbs)* | ||
+ | | rowspan="1"| Trican | ||
+ | | rowspan="1"| Proppant | ||
+ | | Crystalline silica: Quartz (SiO2) | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 1.16711 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| FR-15 (Friction Reducer) | ||
+ | | rowspan="2"| Trican | ||
+ | | rowspan="2"| Friction Reducer | ||
+ | | Proprietary Amide | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 2.5 | ||
+ | | style="text-align: right;" | 0.00247 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Mineral oil/ light hydrotreated pet. distillate | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 25 | ||
+ | | style="text-align: right;" | 0.02474 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Bio Clear 5000 (Biocide) | ||
+ | | rowspan="2"| Trican | ||
+ | | rowspan="2"| Biocide | ||
+ | | Polyethylene glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 70 | ||
+ | | style="text-align: right;" | 0.01691 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2,2-dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00242 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="11"| | ||
+ | | rowspan="11"| | ||
+ | | rowspan="11"| Other Chemicals | ||
+ | | Sorbitan monooleate | ||
+ | | 1338-43-8 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | N2 | ||
+ | | 7727-37-9 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | CO2 | ||
+ | | 124-38-9 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Copolymer of acrylamide-AETAC | ||
+ | | 69418-26-4 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Trade Secret Ingredient | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Alcohols, C12-16, ethoxylated | ||
+ | | 68551-12-2 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Inorganic phosphate | ||
+ | | 7632-05-5 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Trade Secret | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Organic acid derivatives | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Sodium Chloride | ||
+ | | 7647-14-5 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| AI-7NR (Acid Inhibitor) | ||
+ | | rowspan="1"| Trican | ||
+ | | rowspan="1"| Acid Inhibitor | ||
+ | | Prop-2-yn-1-ol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00003000 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 138: | Line 337: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | + | | 2012-S02 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2012- | ||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 112.00 Bbl | | style="text-align: right;" | 112.00 Bbl | ||
Line 174: | Line 343: | ||
| WMGR119 | | WMGR119 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 74.47 Tons | | style="text-align: right;" | 74.47 Tons | ||
Line 180: | Line 349: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 36.70 Tons | | style="text-align: right;" | 36.70 Tons | ||
Line 186: | Line 355: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 4,914.00 Bbl | | style="text-align: right;" | 4,914.00 Bbl | ||
Line 192: | Line 361: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 95.00 Bbl | | style="text-align: right;" | 95.00 Bbl | ||
Line 198: | Line 367: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M05 |
| Drilling Fluid Waste (in Barrels) RWC 803 | | Drilling Fluid Waste (in Barrels) RWC 803 | ||
| style="text-align: right;" | 149.65 Bbl | | style="text-align: right;" | 149.65 Bbl | ||
Line 204: | Line 373: | ||
| THR029 | | THR029 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M05 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 25.00 Bbl | | style="text-align: right;" | 25.00 Bbl | ||
Line 210: | Line 379: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M06 |
| Fracturing Fluid Waste (in Barrels) RWC 805 | | Fracturing Fluid Waste (in Barrels) RWC 805 | ||
| style="text-align: right;" | 52.50 Bbl | | style="text-align: right;" | 52.50 Bbl | ||
Line 216: | Line 385: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M06 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 3.00 Tons | | style="text-align: right;" | 3.00 Tons | ||
Line 222: | Line 391: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M08 |
| Fracturing Fluid Waste (in Tons) RWC 805 | | Fracturing Fluid Waste (in Tons) RWC 805 | ||
| style="text-align: right;" | 5.00 Tons | | style="text-align: right;" | 5.00 Tons | ||
Line 247: | Line 416: | ||
| 2005422 | | 2005422 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2011-09-15 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 254: | Line 423: | ||
| 2009283 | | 2009283 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2011-10-05 |
| Drilling/Alteration | | Drilling/Alteration | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 261: | Line 430: | ||
| 2011518 | | 2011518 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2011-10-13 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 268: | Line 437: | ||
| 2013103 | | 2013103 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2011-10-07 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 275: | Line 444: | ||
| 2284623 | | 2284623 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2014-07-07 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 282: | Line 451: | ||
| 2378805 | | 2378805 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2015-06-05 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 357: | Line 526: | ||
| 621822 | | 621822 | ||
| 10/05/2011 | | 10/05/2011 | ||
− | | 10 | + | | 2011-10-05 |
| 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 365: | Line 534: | ||
| 621823 | | 621823 | ||
| 10/05/2011 | | 10/05/2011 | ||
− | | | + | | 2011-10-05 |
| 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | ||
| Administrative | | Administrative | ||
Line 373: | Line 542: | ||
| 622917 | | 622917 | ||
| 10/07/2011 | | 10/07/2011 | ||
− | | | + | | 2011-10-07 |
| 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 381: | Line 550: | ||
| 622918 | | 622918 | ||
| 10/07/2011 | | 10/07/2011 | ||
− | | | + | | 2011-10-07 |
| 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 389: | Line 558: | ||
| 622919 | | 622919 | ||
| 10/07/2011 | | 10/07/2011 | ||
− | | | + | | 2011-10-07 |
| 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 397: | Line 566: | ||
| 622920 | | 622920 | ||
| 10/07/2011 | | 10/07/2011 | ||
− | | | + | | 2011-10-07 |
| 78.56LINER - Improperly lined pit | | 78.56LINER - Improperly lined pit | ||
| Administrative | | Administrative | ||
Line 405: | Line 574: | ||
| 622921 | | 622921 | ||
| 10/07/2011 | | 10/07/2011 | ||
− | | | + | | 2011-10-07 |
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 413: | Line 582: | ||
| 622922 | | 622922 | ||
| 10/07/2011 | | 10/07/2011 | ||
− | | | + | | 2011-10-07 |
| 509 - Failure to comply w/ order, CO&A, hindrance to personnel, misrepresentation under OGA | | 509 - Failure to comply w/ order, CO&A, hindrance to personnel, misrepresentation under OGA | ||
| Administrative | | Administrative | ||
Line 437: | Line 606: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-115-20646 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.684072,"lon":-75.647581,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Lenox Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 150234 | |
Farm/Lease Name: VALENTINE SOLIMAN GAS UNIT 4H | |
License Status: Plugged OG Well | |
Spud Date: 2011-09-20 | |
Permit Date: 2011-08-31 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.684072 | |
Longitude: -75.647581 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-06-03 | 2013-06-04 | 7572 | 1,654,420.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | White 30/50 | Trican | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 8.02715 | 0 |
Water | Customer | Carrier | Water | 7732-18-5 | 100 | 89.71 | 0 | |
SI-7 (Scale Inhibitor) | Trican | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00961 | 0 | |
15% HCL | Trican | Carrier | Hydrochloric Acid | 7647-01-0 | 15 | 0.1407 | 0 | |
100 Mesh, Bulk (over 20K lbs)* | Trican | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 1.16711 | 0 | |
FR-15 (Friction Reducer) | Trican | Friction Reducer | Proprietary Amide | Proprietary | 2.5 | 0.00247 | 0 | |
Mineral oil/ light hydrotreated pet. distillate | 64742-47-8 | 25 | 0.02474 | 0 | ||||
Bio Clear 5000 (Biocide) | Trican | Biocide | Polyethylene glycol | 25322-68-3 | 70 | 0.01691 | 0 | |
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 10 | 0.00242 | 0 | ||||
Other Chemicals | Sorbitan monooleate | 1338-43-8 | 0 | 0 | 0 | |||
N2 | 7727-37-9 | 0 | 0 | 0 | ||||
Water | 7732-18-5 | 0 | 0 | 0 | ||||
CO2 | 124-38-9 | 0 | 0 | 0 | ||||
Copolymer of acrylamide-AETAC | 69418-26-4 | 0 | 0 | 0 | ||||
Trade Secret Ingredient | Proprietary | 0 | 0 | 0 | ||||
Alcohols, C12-16, ethoxylated | 68551-12-2 | 0 | 0 | 0 | ||||
Inorganic phosphate | 7632-05-5 | 0 | 0 | 0 | ||||
Trade Secret | Proprietary | 0 | 0 | 0 | ||||
Organic acid derivatives | Proprietary | 0 | 0 | 0 | ||||
Sodium Chloride | 7647-14-5 | 0 | 0 | 0 | ||||
AI-7NR (Acid Inhibitor) | Trican | Acid Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00003000 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-S02 | Drilling Fluid Waste (in Barrels) | 112.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013-S01 | Drill Cuttings (in Tons) | 74.47 Tons | LANDFILL | 101247 |
2013-S02 | Drill Cuttings (in Tons) | 36.70 Tons | LANDFILL | 101247 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 4,914.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 95.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M05 | Drilling Fluid Waste (in Barrels) RWC 803 | 149.65 Bbl | LANDFILL | THR029 |
2016-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 25.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M06 | Fracturing Fluid Waste (in Barrels) RWC 805 | 52.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M06 | Synthetic Liner Materials (in Tons) RWC 806 | 3.00 Tons | LANDFILL | 101247 |
2016-M08 | Fracturing Fluid Waste (in Tons) RWC 805 | 5.00 Tons | LANDFILL | THR029 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2005422 | Primary Facility | 2011-09-15 | Routine/Complete Inspection | No Violations Noted | |
2009283 | Primary Facility | 2011-10-05 | Drilling/Alteration | Violation(s) Noted | Falcon 23. Reported gas bubbling after cementing 9 5/8". Floats did not hold, had 24 bbls returns reported. noticed bubbling morning of 10/4. Bubbling consistent on 9 x 13 annulus. Operator reviewing logs and will report to DEP on plans going forward. While on site was notified of diesel spill of 20 - 30 gallons. Overfilled generator. Not on containment. Operator reportedly overexcavated area (12' x 8')and disposed of material into rolloff. Operator also used biomatrix absorbent on spill. DEP will follow up with any necessary sampling requirements. |
2011518 | Primary Facility | 2011-10-13 | Drilling/Alteration | No Violations Noted | DEP on site at 12:30. Falcon Rig 23. Follow up on status of bubbling on backside of 9 5/8". Company Man indicated bubbling has stopped. Attempted perf and squeezes were completed with no injection success. DEP notified, and ok'd go ahead of drilling. At time of inspection, no bubbling was observed. Annulus currently vented and operator will be installing pressure gauge to monitor pressure. Drilling to @ 6100' on air an then moving to next location. Details on perf and squeeze on inspection report. DEP offsite 15:10. |
2013103 | Primary Facility | 2011-10-07 | Incident- Response to Accident or Event | Violation(s) Noted | |
2284623 | Primary Facility | 2014-07-07 | Routine/Complete Inspection | No Violations Noted | Inspected Price KK pad. ID sign is in place and indicates two permit numbers associated with this pad, the Valentine Soliman 3H (115-20602) and 4H (115-20646). A third permit, 115-21479, was issued on 10/25/2013 and has yet to be drilled. On the East side of the access road, a flat area has been created in the area designated on the plan as "timber" and "topsoil stockpile". Swale #2 has been leveled to access the area. The plans need to be updated to reflect the change. No E&S issues were noted and significant perrenial growth of red clover, white clover, and birdsfoot treefoil were observed over all revegetated areas. The two wells drilled on this pad have been stimulated but are not in production. Neither well was tagged. No bubbling was observed in either cellar. Felt has been placed around the area of both wells in preparation for containment. No evidence of a spill or release was noted. Contact Mike O'Donnell with questions about this report at 570.346.5536. |
2378805 | Primary Facility | 2015-06-05 | Routine/Complete Inspection | No Violations Noted | |
2483435 | Primary Facility | 2016-05-05 | Routine/Complete Inspection | No Violations Noted | |
2483437 | Primary Facility | 2016-05-12 | Follow-up Inspection | No Violations Noted | |
2487552 | Primary Facility | 2016-05-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2487589 | Primary Facility | 2016-05-19 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2487592 | Primary Facility | 2016-05-20 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2489336 | Primary Facility | 2016-05-23 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2589013 | Primary Facility | 2017-04-27 | Follow-up Inspection | No Violations Noted | |
2595760 | Primary Facility | 2017-05-11 | Plugging(Includes Plugged/Mined Through) | No Violations Noted |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2009283 | 621822 | 10/05/2011 | 2011-10-05 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | inspected by Watson on 10/13/2011 with No viols |
2009283 | 621823 | 10/05/2011 | 2011-10-05 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56a Operator failed to contain diesel in tank. Overfilled generator. Spilled 20 - 30 gallons on pad, not on containment. |
2013103 | 622917 | 10/07/2011 | 2011-10-07 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2013103 | 622918 | 10/07/2011 | 2011-10-07 | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | Environmental Health & Safety | |
2013103 | 622919 | 10/07/2011 | 2011-10-07 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | |
2013103 | 622920 | 10/07/2011 | 2011-10-07 | 78.56LINER - Improperly lined pit | Administrative | Failed to contain pollutional material in a pit or tank. |
2013103 | 622921 | 10/07/2011 | 2011-10-07 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | Violation should be cited as SWMA 610. |
2013103 | 622922 | 10/07/2011 | 2011-10-07 | 509 - Failure to comply w/ order, CO&A, hindrance to personnel, misrepresentation under OGA | Administrative | Failed to comply with permit requirements in violation of OGA 509. Specifically failed to ensure adequate secondary containment for a generator which released 20-30 gallons of diesel fuel which was deposited onto the well pad. |
For data sources see[7]