If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20646 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.684072,"lon":-75.647581,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Lenox Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 150234 | |
Farm/Lease Name: VALENTINE SOLIMAN GAS UNIT 4H | |
License Status: Plugged and Abandoned | |
Spud Date: 2011-09-20 | |
Permit Date: 2011-08-31 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.684072 | |
Longitude: -75.647581 |
Date | Event |
---|---|
2011-08-31 | New Permit Application |
2011-09-20 | Performed Spud Operation |
2011-11-30 | Drilling Completion |
2013-03-06 | Perforation |
2013-03-06 | Performed Stage 1 of Stimulation |
2013-04-06 | Perforation |
2013-04-06 | Performed Stage 2 of Stimulation |
2013-04-06 | Performed Stage 3 of Stimulation |
2013-04-06 | Performed Stage 4 of Stimulation |
2013-08-26 | DEVIATED |
2016-03-03 | Inactive Well Request Granted |
2016-05-17 | Begin Plugging |
2016-05-23 | Finished Plugging |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-06-03 | 2013-06-04 | 7,572 | 1,654,420 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | White 30/50 | Trican | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 8.02715 | 0 |
Water | Customer | Carrier | Water | 7732-18-5 | 100 | 89.71 | 0 | |
SI-7 (Scale Inhibitor) | Trican | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00961 | 0 | |
15% HCL | Trican | Carrier | Hydrochloric Acid | 7647-01-0 | 15 | 0.1407 | 0 | |
100 Mesh, Bulk (over 20K lbs)* | Trican | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 1.16711 | 0 | |
FR-15 (Friction Reducer) | Trican | Friction Reducer | Proprietary Amide | Proprietary | 2.5 | 0.00247 | 0 | |
Mineral oil/ light hydrotreated pet. distillate | 64742-47-8 | 25 | 0.02474 | 0 | ||||
Bio Clear 5000 (Biocide) | Trican | Biocide | Polyethylene glycol | 25322-68-3 | 70 | 0.01691 | 0 | |
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 10 | 0.00242 | 0 | ||||
Other Chemicals | Sorbitan monooleate | 1338-43-8 | 0 | 0 | 0 | |||
N2 | 7727-37-9 | 0 | 0 | 0 | ||||
Water | 7732-18-5 | 0 | 0 | 0 | ||||
CO2 | 124-38-9 | 0 | 0 | 0 | ||||
Copolymer of acrylamide-AETAC | 69418-26-4 | 0 | 0 | 0 | ||||
Trade Secret Ingredient | Proprietary | 0 | 0 | 0 | ||||
Alcohols, C12-16, ethoxylated | 68551-12-2 | 0 | 0 | 0 | ||||
Inorganic phosphate | 7632-05-5 | 0 | 0 | 0 | ||||
Trade Secret | Proprietary | 0 | 0 | 0 | ||||
Organic acid derivatives | Proprietary | 0 | 0 | 0 | ||||
Sodium Chloride | 7647-14-5 | 0 | 0 | 0 | ||||
AI-7NR (Acid Inhibitor) | Trican | Acid Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00003000 | 0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2013-03-06 | 1 | Sand | 1,694,910 | 8,315 | 7,213 |
2013-04-06 | 2 | Sand | 1,694,910 | 8,594 | 8,209 |
2013-04-06 | 3 | Sand | 1,694,910 | 8,420 | 8,091 |
2013-04-06 | 4 | Sand | 1,694,910 | 8,001 | 7,030 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SOUTHWESTERN ENERGY PROD CO | Drilling Fluid Waste | 112.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 4,914.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 111.17 Tons | LANDFILL | 101247 |
2015 | SWN PROD CO LLC | Produced Fluid | 95.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Synthetic Liner Materials | 3.00 Tons | LANDFILL | 101247 |
2016 | SWN PROD CO LLC | Other Oil & Gas Wastes | 25.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Fracturing Fluid Waste | 52.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Fracturing Fluid Waste | 5.00 Tons | LANDFILL | THR029 |
2016 | SWN PROD CO LLC | Drilling Fluid Waste | 149.65 Bbl | LANDFILL | THR029 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2005422 | Primary Facility | 2011-09-15 | Routine/Complete Inspection | No Violations Noted | |
2009283 | Primary Facility | 2011-10-05 | Drilling/Alteration | Violation(s) Noted | Falcon 23. Reported gas bubbling after cementing 9 5/8". Floats did not hold, had 24 bbls returns reported. noticed bubbling morning of 10/4. Bubbling consistent on 9 x 13 annulus. Operator reviewing logs and will report to DEP on plans going forward. While on site was notified of diesel spill of 20 - 30 gallons. Overfilled generator. Not on containment. Operator reportedly overexcavated area (12' x 8')and disposed of material into rolloff. Operator also used biomatrix absorbent on spill. DEP will follow up with any necessary sampling requirements. |
2011518 | Primary Facility | 2011-10-13 | Drilling/Alteration | No Violations Noted | DEP on site at 12:30. Falcon Rig 23. Follow up on status of bubbling on backside of 9 5/8". Company Man indicated bubbling has stopped. Attempted perf and squeezes were completed with no injection success. DEP notified, and ok'd go ahead of drilling. At time of inspection, no bubbling was observed. Annulus currently vented and operator will be installing pressure gauge to monitor pressure. Drilling to @ 6100' on air an then moving to next location. Details on perf and squeeze on inspection report. DEP offsite 15:10. |
2013103 | Primary Facility | 2011-10-07 | Incident- Response to Accident or Event | Violation(s) Noted | |
2284623 | Primary Facility | 2014-07-07 | Routine/Complete Inspection | No Violations Noted | Inspected Price KK pad. ID sign is in place and indicates two permit numbers associated with this pad, the Valentine Soliman 3H (115-20602) and 4H (115-20646). A third permit, 115-21479, was issued on 10/25/2013 and has yet to be drilled. On the East side of the access road, a flat area has been created in the area designated on the plan as "timber" and "topsoil stockpile". Swale #2 has been leveled to access the area. The plans need to be updated to reflect the change. No E&S issues were noted and significant perrenial growth of red clover, white clover, and birdsfoot treefoil were observed over all revegetated areas. The two wells drilled on this pad have been stimulated but are not in production. Neither well was tagged. No bubbling was observed in either cellar. Felt has been placed around the area of both wells in preparation for containment. No evidence of a spill or release was noted. Contact Mike O'Donnell with questions about this report at 570.346.5536. |
2378805 | Primary Facility | 2015-06-05 | Routine/Complete Inspection | No Violations Noted | |
2483435 | Primary Facility | 2016-05-05 | Routine/Complete Inspection | No Violations Noted | |
2483437 | Primary Facility | 2016-05-12 | Follow-up Inspection | No Violations Noted | |
2487552 | Primary Facility | 2016-05-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2487589 | Primary Facility | 2016-05-19 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2487592 | Primary Facility | 2016-05-20 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2489336 | Primary Facility | 2016-05-23 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2589013 | Primary Facility | 2017-04-27 | Follow-up Inspection | No Violations Noted | |
2595760 | Primary Facility | 2017-05-11 | Plugging(Includes Plugged/Mined Through) | No Violations Noted |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2009283 | 621822 | 10/05/2011 | 2011-10-05 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | inspected by Watson on 10/13/2011 with No viols |
2009283 | 621823 | 10/05/2011 | 2011-10-05 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56a Operator failed to contain diesel in tank. Overfilled generator. Spilled 20 - 30 gallons on pad, not on containment. |
2013103 | 622917 | 10/07/2011 | 2011-10-07 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2013103 | 622918 | 10/07/2011 | 2011-10-07 | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | Environmental Health & Safety | |
2013103 | 622919 | 10/07/2011 | 2011-10-07 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | |
2013103 | 622920 | 10/07/2011 | 2011-10-07 | 78.56LINER - Improperly lined pit | Administrative | Failed to contain pollutional material in a pit or tank. |
2013103 | 622921 | 10/07/2011 | 2011-10-07 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | Violation should be cited as SWMA 610. |
2013103 | 622922 | 10/07/2011 | 2011-10-07 | 509 - Failure to comply w/ order, CO&A, hindrance to personnel, misrepresentation under OGA | Administrative | Failed to comply with permit requirements in violation of OGA 509. Specifically failed to ensure adequate secondary containment for a generator which released 20-30 gallons of diesel fuel which was deposited onto the well pad. |
For data sources see[9]