X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-115-20670"

m
 
(16 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 115-20670
+
| Well ID: 37-115-20670
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.82768, -75.742377 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.827681, -75.742378 | width=100% | height=100% }}
 +
|-
 +
| Country: United States
 +
|-
 +
| State: Pennsylvania
 +
|-
 +
| County: [[Susquehanna_County,_Pennsylvania|Susquehanna]]
 
|-
 
|-
| County: [[Susquehanna County, Pennsylvania|Susquehanna]]
+
| Municipality: [[New Milford Township,_Susquehanna_County,_Pennsylvania|New Milford Township]]
 
|-
 
|-
| Municipality: [[New Milford Township, Susquehanna County, Pennsylvania|New Milford Township]]
+
| Operator Name: [[SWN PROD CO LLC]]
 
|-
 
|-
| Operator Name: [[SOUTHWESTERN ENERGY PROD CO]]
+
| Well Pad ID: [[144552]]
 
|-
 
|-
 
| Farm/Lease Name: FOLGER 1H
 
| Farm/Lease Name: FOLGER 1H
 
|-
 
|-
| First Permit Date: 2011-10-05
+
| License Status:
 +
|-
 +
| Spud Date:
 +
|-
 +
| Permit Date: 2011-10-05
 
|-
 
|-
| Last Permit Date: 2011-10-05
+
| Well Type: GAS
 
|-
 
|-
| Spud Date: 2011-10-21
+
| Unconventional Well: Y
 
|-
 
|-
| Unconventional: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Horizontal: Yes
+
| Conservation: No
 
|-
 
|-
| Producing: Yes
+
| Latitude: 41.827681
 
|-
 
|-
| Violations: None
+
| Longitude: -75.742378
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 
|-
 
|-
| Latitude: 41.82768
+
| 2011-10-05
 +
| New Permit Application
 +
|-
 +
| 2011-10-21
 +
| Performed Spud Operation
 +
|-
 +
| 2012-02-02
 +
| Drilling Completion
 +
|-
 +
| 2013-02-07
 +
| Perforation
 +
|-
 +
| 2013-02-07
 +
| Performed Stimulation 
 +
|-
 +
| 2013-05-24
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
| Longitude: -75.742377
+
| 1
 +
| 2013-02-04
 +
| 2013-02-04
 +
| style="text-align: right;" | 6,793
 +
| style="text-align: right;" | 5,978,952
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
__TOC__
+
==== Fluid Composition Data ====
== Well Inspection Data ==
 
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Job Number
!scope="col" | DATE
+
!scope="col" | Trade Name
!scope="col" | DESCRIPTION
+
!scope="col" | Supplier
!scope="col" | COMMENT
+
!scope="col" | Purpose
!scope="col" | VIOLATION ID
+
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="12"| 1
 +
| rowspan="1"| SI-115
 +
| rowspan="1"| Clearwater International
 +
| rowspan="1"| Scale Inhibitor
 +
| Phosphonic acid, [[(phosphonomethyl)imino]bis[2,1-ethanediylnitrilobis(methylene)]]tetrakis-,<br/> sodium salt
 +
| 22042-96-2
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00226000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| 15 HCl
 +
| rowspan="1"| Clearwater International
 +
| rowspan="1"| Acid
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.11
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| AI-250
 +
| rowspan="2"| Clearwater International
 +
| rowspan="2"| Acid Inhibitor
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00077000
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00077000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| APS 920
 +
| rowspan="1"| Clearwater International
 +
| rowspan="1"| Friction Reducer
 +
| Non Hazardous
 +
|
 +
| style="text-align: right;" | 200.00
 +
| style="text-align: right;" | 0.20
 +
| style="text-align: right;" |
 
|-
 
|-
| 2014450
+
|- valign="top"
| 2011-10-25
+
| rowspan="3"| Biocide EC 6116A
| No Violations Noted
+
| rowspan="3"| Nalco
| DEP arrived on site 14:30 pm. Minichi spud rig on site spudding in well. Site ID sign in place with proper permit information posted. No violations observed.
+
| rowspan="3"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00411000
 +
| style="text-align: right;" |
 +
|-
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00068000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00822000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="0"| Chemical Name
 +
| rowspan="0"| Southwestern Energy
 +
| rowspan="0"| Sand
 +
|- valign="top"
 +
| rowspan="0"| Chemical Name
 +
| rowspan="0"| Southwestern Energy
 +
| rowspan="0"| Water/Produced Water
 +
|- valign="top"
 +
| rowspan="4"| Chemical Name
 +
| rowspan="4"|
 +
| rowspan="4"| Purpose
 +
| H2O + Disolved Salts
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 90.78
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Ingredients
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
| 2041353
 
| 2012-02-06
 
| No Violations Noted
 
| Company Man = Joe Davis.  Rig is DDI-10.  Have set 5 1/2" at 9545'.  Cemented up to approx. 1875'. 20 " is set at 76', 13 3/8" set at 650', 9 5/8" set at 1635'. 5 /12" set at 9545''.  Currently breaking down rig and morving to Barkems Squirrel location.  Drilers log on site and up to date.  noted: encountered a 100' fault at @ 2750 into lateral..
 
 
|  
 
|  
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 8.31
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
| 2013-02-07
 +
| style="text-align: right;" |
 +
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Completion Reports - Stimulations
 +
| publisher = Pennsylvania Department of Conservation and Natural Resources
 +
| date = 2020-03-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-03-02 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2011
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2012
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2013
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 606,793.00
 +
| style="text-align: right;" | 248
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2014
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 907,414.00
 +
| style="text-align: right;" | 362
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-2
+
| 2015
| style="text-align:right;" | 0.0
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 658,212.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 542,755.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2017
| style="text-align:right;" | 0.0
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 307,108.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 356,245.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2019
| style="text-align:right;" | 0.0
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 351,674.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-2
+
| 2012
| DRILLING FLUID WASTE
+
| [[SOUTHWESTERN ENERGY PROD CO]]
| style="text-align:right;" | 265.0
+
| Drilling Fluid Waste
| Bbl
+
| style="text-align: right;" | 265.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR119
 
| WMGR119
| EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT)
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2012
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 717.93 Tons
 +
| LANDFILL
 +
| THR029
 +
|-
 +
| 2013
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 6,760.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2013
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 18.67 Tons
 +
| LANDFILL
 +
| 101247
 
|-
 
|-
| 2012-1
+
| 2013
| DRILL CUTTINGS
+
| [[SOUTHWESTERN ENERGY PROD CO]]
| style="text-align:right;" | 717.93
+
| Fracturing Fluid Waste
| Tons
+
| style="text-align: right;" | 20.84 Tons
 
| LANDFILL
 
| LANDFILL
| THR029
+
| 101247
| TUNNELL HILL RECLAMATION LANDFILL
+
|-
| NEWLEXINGTON
+
| 2013
| OH
+
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 4,130.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2014
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,956.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 742.75 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 35.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 431.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 50.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 170.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 58.50 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 460.25 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 93.25 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 177.83 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 243.25 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 57.50 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 37.04 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 2014450
 +
| Primary Facility
 +
| 2011-10-25
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| DEP arrived on site 14:30 pm.  Minichi spud rig on site spudding in well.  Site ID sign in place with proper permit information posted.  No violations observed.
 +
|-
 +
| 2041353
 +
| Primary Facility
 +
| 2012-02-06
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| Company Man = Joe Davis.  Rig is DDI-10.  Have set 5 1/2" at 9545'.  Cemented up to approx. 1875'. 20 " is set at 76', 13 3/8" set at 650', 9 5/8" set at 1635'. 5 /12" set at 9545''.  Currently breaking down rig and morving to Barkems Squirrel location.  Drilers log on site and up to date.  noted: encountered a 100' fault at @ 2750 into lateral..
 +
|-
 +
| 2152523
 +
| Primary Facility
 +
| 2013-03-29
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2208546
 +
| Primary Facility
 +
| 2013-09-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Refer to inspection ID # 2208531
 +
|-
 +
| 2208792
 +
| Primary Facility
 +
| 2013-09-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Refer to inspection ID # 2208782
 +
|-
 +
| 2260923
 +
| Primary Facility
 +
| 2014-04-08
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On 4/8/14, the Department conducted a follow-up inspection of SWN RU 32 Folger Pad where violations had been noted by the Department during a 9/24/13 inspection.  The cut slope has been effectively stabilized.  As of this inspection, violations noted in the 9/24/13 inspection have been corrected/abated.
 +
|-
 +
| 2359311
 +
| Primary Facility
 +
| 2015-04-07
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2477437
 +
| Primary Facility
 +
| 2016-04-22
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2488555
 +
| Primary Facility
 +
| 2016-05-31
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2558039
 +
| Primary Facility
 +
| 2017-02-01
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|  At time of inspection, arrived on site at 15:25p.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 557psi on the production casing and 507psi on the production line. I took a walk around the location and noticed that the entire site was covered with snow except a section between the production tanks and the production units. I contacted Gene Rickard (DEP WQS) to let him know about the well site.
 +
I left the site at 16:05p.m.
 +
|-
 +
| 2564074
 +
| Primary Facility
 +
| 2017-02-02
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Today’s inspection was conducted after a Department Oil and Gas Inspector noticed a large area of unfrozen standing water on the well pad surface near the production tanks and production units.  The unfrozen water is unusual in respect to the fact that recent and current temperatures have been and are well below freezing.  The Department employed an Extech Instruments ExStik 2 Conductivity Meter, tested the water and found the conductivity to be around 90 microsiemens, a relatively low number.  Of note is the fact that algae was present and thriving in the standing water.  The presence of the algae suggests that the water is probably an expression of ground water which would also explain the temperatures recorded of the standing water of 9 degrees Celsius.  Overall, the pad site looked good with no E&S violations observed.
 +
|-
 +
| 2564093
 +
| Primary Facility
 +
| 2017-02-06
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Today’s inspection is being conducted after having consulted with a Department Geologist and a Department Oil and Gas Inspector in reference to the standing water observed on the SWN RU 32 Folger Pad.  The consensus was that it would be prudent for the Department to collect samples, soil and water, of the standing unfrozen water and associated contact soil on the pad to ensure that the presence of the standing unfrozen water is a natural phenomenon.  Present during the inspection was myself, Jon Sassi, Department EPS, Eric Rooney, Department LPG, David Schoonover, Department OGI, and Mike Deming, SWN Senior Regulatory Analyst.  Mr. Deming did state that SWN has always been aware of the standing water and that its presence has been attributed to the theory that the water is a natural expression of ground water.  The Department collected 3 separate samples, one soil sample and two water samples.  The soil sample, 0257238, will be tested for glycol and methanol.  One of the water samples, 0257239 will be tested
 +
|-
 +
| 2651855
 +
| Primary Facility
 +
| 2017-10-25
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At time of inspection.
 +
The well was in production.
 +
The cellar was full of gravel and there was no gas detected at the perimeter of the cellar.
 +
I took a walk around the location and there were no obvious concerns noticed.
 +
There were no violation noted.
 +
|-
 +
| 2753332
 +
| Primary Facility
 +
| 2018-07-18
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At time of inspection.                                                                                                                                                                                               
 +
The well was in production.                                                                                                                                                                                                                                                                                          The cellar was full of gravel and there was no gas detected at the perimeter of the cellar.
 +
I took a walk around the location and there were no obvious concerns noticed.
 +
There were no violations noted.
 +
|-
 +
| 2855694
 +
| Primary Facility
 +
| 2019-03-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At time of inspection.
 +
The well was in production.
 +
The cellar was full of gravel and there was no gas detected at the perimeter of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 3/4/19.
 +
I took a walk around the location and there were no obvious concerns noticed.
 +
There were no violations noted.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 20:01, 15 May 2020

Well Details

Well ID: 37-115-20670
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 144552
Farm/Lease Name: FOLGER 1H
License Status:
Spud Date:
Permit Date: 2011-10-05
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.827681
Longitude: -75.742378

For data sources see[1][2][3]

Well History

Date Event
2011-10-05 New Permit Application
2011-10-21 Performed Spud Operation
2012-02-02 Drilling Completion
2013-02-07 Perforation
2013-02-07 Performed Stimulation
2013-05-24 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-02-04 2013-02-04 6,793 5,978,952

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SI-115 Clearwater International Scale Inhibitor Phosphonic acid, [[(phosphonomethyl)imino]bis[2,1-ethanediylnitrilobis(methylene)]]tetrakis-,
sodium salt
22042-96-2 20.00 0.00226000
15 HCl Clearwater International Acid Hydrochloric acid 7647-01-0 15.00 0.11
AI-250 Clearwater International Acid Inhibitor Isopropanol 67-63-0 40.00 0.00077000
Propargyl alcohol 107-19-7 40.00 0.00077000
APS 920 Clearwater International Friction Reducer Non Hazardous 200.00 0.20
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 30.00 0.00411000
Dibromoacetonitrile 3252-43-5 5.00 0.00068000
Polyethylene glycol 25322-68-3 60.00 0.00822000
Chemical Name Southwestern Energy Sand
Chemical Name Southwestern Energy Water/Produced Water
Chemical Name Purpose H2O + Disolved Salts 100.00 90.78
Ingredients
Quartz 14808-60-7 100.00 8.31

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-02-07 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 606,793.00 248 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 907,414.00 362 0.00 0 0.00 0
2015 SWN PROD CO LLC 658,212.00 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 542,755.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 307,108.00 364 0.00 0 0.00 0
2018 SWN PROD CO LLC 356,245.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 351,674.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Drilling Fluid Waste 265.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 717.93 Tons LANDFILL THR029
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 6,760.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 18.67 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 20.84 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 4,130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid 1,956.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid 742.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Other Oil & Gas Wastes 35.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 431.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 50.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 170.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 58.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 460.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 93.25 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 177.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 243.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 57.50 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 37.04 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2014450 Primary Facility 2011-10-25 Drilling/Alteration No Violations Noted DEP arrived on site 14:30 pm. Minichi spud rig on site spudding in well. Site ID sign in place with proper permit information posted. No violations observed.
2041353 Primary Facility 2012-02-06 Drilling/Alteration No Violations Noted Company Man = Joe Davis. Rig is DDI-10. Have set 5 1/2" at 9545'. Cemented up to approx. 1875'. 20 " is set at 76', 13 3/8" set at 650', 9 5/8" set at 1635'. 5 /12" set at 9545. Currently breaking down rig and morving to Barkems Squirrel location. Drilers log on site and up to date. noted: encountered a 100' fault at @ 2750 into lateral..
2152523 Primary Facility 2013-03-29 Routine/Partial Inspection No Violations Noted
2208546 Primary Facility 2013-09-24 Routine/Complete Inspection No Violations Noted Refer to inspection ID # 2208531
2208792 Primary Facility 2013-09-24 Routine/Complete Inspection No Violations Noted Refer to inspection ID # 2208782
2260923 Primary Facility 2014-04-08 Routine/Complete Inspection No Violations Noted On 4/8/14, the Department conducted a follow-up inspection of SWN RU 32 Folger Pad where violations had been noted by the Department during a 9/24/13 inspection. The cut slope has been effectively stabilized. As of this inspection, violations noted in the 9/24/13 inspection have been corrected/abated.
2359311 Primary Facility 2015-04-07 Routine/Complete Inspection No Violations Noted
2477437 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted
2488555 Primary Facility 2016-05-31 Routine/Complete Inspection No Violations Noted
2558039 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 15:25p.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 557psi on the production casing and 507psi on the production line. I took a walk around the location and noticed that the entire site was covered with snow except a section between the production tanks and the production units. I contacted Gene Rickard (DEP WQS) to let him know about the well site.

I left the site at 16:05p.m.

2564074 Primary Facility 2017-02-02 Routine/Complete Inspection No Violations Noted Today’s inspection was conducted after a Department Oil and Gas Inspector noticed a large area of unfrozen standing water on the well pad surface near the production tanks and production units. The unfrozen water is unusual in respect to the fact that recent and current temperatures have been and are well below freezing. The Department employed an Extech Instruments ExStik 2 Conductivity Meter, tested the water and found the conductivity to be around 90 microsiemens, a relatively low number. Of note is the fact that algae was present and thriving in the standing water. The presence of the algae suggests that the water is probably an expression of ground water which would also explain the temperatures recorded of the standing water of 9 degrees Celsius. Overall, the pad site looked good with no E&S violations observed.
2564093 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted Today’s inspection is being conducted after having consulted with a Department Geologist and a Department Oil and Gas Inspector in reference to the standing water observed on the SWN RU 32 Folger Pad. The consensus was that it would be prudent for the Department to collect samples, soil and water, of the standing unfrozen water and associated contact soil on the pad to ensure that the presence of the standing unfrozen water is a natural phenomenon. Present during the inspection was myself, Jon Sassi, Department EPS, Eric Rooney, Department LPG, David Schoonover, Department OGI, and Mike Deming, SWN Senior Regulatory Analyst. Mr. Deming did state that SWN has always been aware of the standing water and that its presence has been attributed to the theory that the water is a natural expression of ground water. The Department collected 3 separate samples, one soil sample and two water samples. The soil sample, 0257238, will be tested for glycol and methanol. One of the water samples, 0257239 will be tested
2651855 Primary Facility 2017-10-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violation noted.

2753332 Primary Facility 2018-07-18 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2855694 Primary Facility 2019-03-19 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 3/4/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.