X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-21297"

m
 
(16 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 117-21297
+
| Well ID: 37-117-21297
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.719722, -77.12048 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.719722, -77.120481 | width=100% | height=100% }}
 
|-
 
|-
| County: [[wikipedia:Tioga County, Pennsylvania|Tioga]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[wikipedia:Covington Township, Tioga County, Pennsylvania|Covington Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[wikipedia:SWEPI LP|SWEPI LP]]
+
| County: [[Tioga_County,_Pennsylvania|Tioga]]
 +
|-
 +
| Municipality: [[Covington Township,_Tioga_County,_Pennsylvania|Covington Township]]
 +
|-
 +
| Operator Name: [[SWEPI LP]]
 +
|-
 +
| Well Pad ID: [[149447]]
 
|-
 
|-
 
| Farm/Lease Name: TORPY VAN ORDER 574 3H
 
| Farm/Lease Name: TORPY VAN ORDER 574 3H
 
|-
 
|-
| First Permit Date: 2011-07-28
+
| License Status: INACTIVE
 
|-
 
|-
| Last Permit Date: 2011-07-28
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2011-08-06
+
| Permit Date: 2011-07-28
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: None
+
| Conservation: No
 
|-
 
|-
 
| Latitude: 41.719722
 
| Latitude: 41.719722
 
|-
 
|-
| Longitude: -77.12048
+
| Longitude: -77.120481
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2011-07-28
 +
| New Permit Application
 +
|-
 +
| 2011-08-06
 +
| Performed Spud Operation
 +
|-
 +
| 2011-10-06
 +
| Drilling Completion
 +
|-
 +
| 2012-12-13
 +
| DEVIATED
 
|-
 
|-
 
|}
 
|}
__TOC__
+
For data sources see<ref>{{cite web
== Well Inspection Data ==
+
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Job Number
!scope="col" | DATE
+
!scope="col" | Trade Name
!scope="col" | DESCRIPTION
+
!scope="col" | Supplier
!scope="col" | COMMENT
+
!scope="col" | Purpose
!scope="col" | VIOLATION ID
+
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 2008893
+
|}-->
| 2011-10-03
+
 
| No Violations Noted
+
<!--== Stimulation Data ==
|  
+
{| class="wikitable sortable" width="95%"
|  
+
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 
|-
 
|-
|}
+
|}-->
 +
 
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2011
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-2
+
| 2012
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2014
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2016
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2019
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
== Waste Data ==
+
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
+
|-
!scope="col" | FACILITY CITY
+
|}-->
!scope="col" | FACILITY STATE
+
 
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 2008893
 +
| Primary Facility
 +
| 2011-10-03
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2182059
 +
| Primary Facility
 +
| 2013-07-09
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2501816
 +
| Primary Facility
 +
| 2016-07-13
 +
| Site Restoration
 +
| No Violations Noted
 +
| 2 Marcellus Shale wells on this pad; 1 is plugged.  Recommending approval of NOT.
 +
|-
 +
| 2518357
 +
| Primary Facility
 +
| 2016-09-12
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Inspection of SWEPI’s Torpy & Van Order Inc 574 pad in Covington Twp, Tioga County conducted September 12, 2016 at approximately 12:00 pm. There were 2 wells on the pad at the time of inspection; the 1V (Plugged 9/7/11) and the 3H (Regulatory Inactive Status). The 1V is plugged and capped off with blanked spool with a needle valve (shut-in) on the cap. The 3H is shut in with a lower master valve and cap atop production casing spool/tubing hanger. The cellar was filled with gravel and there were (4) total vent pipes plumbed to surface coming up through the gravel. There were (2) 2” vent pipes assumed to be backside of the production casing (9 5/8” x 5 ½”) annulus. One of these vent pipes was shut-in, while the other was 90’d downward into a bucket. A field reading with an Altair 5x gas meter placed next to the vent outlet showed 100% LEL 66% Methane. The other (2) remaining smaller vent pipes I assume to be the intermediate csg’s annulus (1 ½” vent) and the surface casing’s annulus (1” vent). No gas was prese
 +
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]

Latest revision as of 02:22, 16 May 2020

Well Details

Well ID: 37-117-21297
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Covington Township
Operator Name: SWEPI LP
Well Pad ID: 149447
Farm/Lease Name: TORPY VAN ORDER 574 3H
License Status: INACTIVE
Spud Date:
Permit Date: 2011-07-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.719722
Longitude: -77.120481

For data sources see[1][2][3]

Well History

Date Event
2011-07-28 New Permit Application
2011-08-06 Performed Spud Operation
2011-10-06 Drilling Completion
2012-12-13 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0
2019 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2008893 Primary Facility 2011-10-03 Drilling/Alteration No Violations Noted
2182059 Primary Facility 2013-07-09 Routine/Complete Inspection No Violations Noted
2501816 Primary Facility 2016-07-13 Site Restoration No Violations Noted 2 Marcellus Shale wells on this pad; 1 is plugged. Recommending approval of NOT.
2518357 Primary Facility 2016-09-12 Routine/Complete Inspection No Violations Noted Inspection of SWEPI’s Torpy & Van Order Inc 574 pad in Covington Twp, Tioga County conducted September 12, 2016 at approximately 12:00 pm. There were 2 wells on the pad at the time of inspection; the 1V (Plugged 9/7/11) and the 3H (Regulatory Inactive Status). The 1V is plugged and capped off with blanked spool with a needle valve (shut-in) on the cap. The 3H is shut in with a lower master valve and cap atop production casing spool/tubing hanger. The cellar was filled with gravel and there were (4) total vent pipes plumbed to surface coming up through the gravel. There were (2) 2” vent pipes assumed to be backside of the production casing (9 5/8” x 5 ½”) annulus. One of these vent pipes was shut-in, while the other was 90’d downward into a bucket. A field reading with an Altair 5x gas meter placed next to the vent outlet showed 100% LEL 66% Methane. The other (2) remaining smaller vent pipes I assume to be the intermediate csg’s annulus (1 ½” vent) and the surface casing’s annulus (1” vent). No gas was prese

For data sources see[6]

References