If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-073-22161 | | Well ID: 34-073-22161 | ||
− | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39. | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39.55619356, -82.45354214 | width=100% | height=100% }} |
|- | |- | ||
− | | County: | + | | County: [[Hocking County, Ohio|Hocking]] |
|- | |- | ||
− | | Municipality: | + | | Municipality: |
|- | |- | ||
− | | Operator Name: | + | | Operator Name: [[JEANIE ENTERPISES LLC]] |
|- | |- | ||
− | | Well Pad ID: | + | | Well Pad ID: |
|- | |- | ||
− | | Farm/Lease Name: | + | | Farm/Lease Name: |
|- | |- | ||
− | | First Permit Date: | + | | First Permit Date: |
|- | |- | ||
− | | Last Permit Date: | + | | Last Permit Date: |
|- | |- | ||
| Spud Date: 1979-08-11 | | Spud Date: 1979-08-11 | ||
|- | |- | ||
− | | Unconventional: | + | | Unconventional: No |
|- | |- | ||
− | | | + | | Configuration: Vertical |
|- | |- | ||
− | | | + | | Well Status: Active Injection |
|- | |- | ||
− | | Violations: | + | | Violations: 0 |
|- | |- | ||
− | | Latitude: 39. | + | | Latitude: 39.55619356 |
|- | |- | ||
− | | Longitude: -82. | + | | Longitude: -82.45354214 |
|- | |- | ||
|} | |} | ||
Line 43: | Line 43: | ||
!scope="col" | OIL QUANTITY | !scope="col" | OIL QUANTITY | ||
!scope="col" | OIL PRODUCTION DAYS | !scope="col" | OIL PRODUCTION DAYS | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | - | + | | 1988-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 1991-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2004-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2005-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2006-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2008-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2009-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Ohio Department of Natural Resources RBDMS | ||
+ | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
+ | | date = 2015-06-19 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production | ||
+ | | accessdate = 2015-06-20 }}</ref> | ||
+ | == Inspection Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | INSPECTION ID | ||
+ | !scope="col" | DATE | ||
+ | !scope="col" | DESCRIPTION | ||
+ | !scope="col" | COMMENT | ||
+ | !scope="col" | VIOLATION ID | ||
+ | !scope="col" | VIOLATION CODE | ||
+ | !scope="col" | VIOLATION COMMENT | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | An inspection of the | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | 2009-06- | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | An inspection revealed | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | An inspection revealed | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | An inspection revealed | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | | | + | | 2009-06-16 |
− | | | + | | |
− | | | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1035524058 |
− | + | | 2009-06-16 | |
− | + | | | |
− | + | | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | |
− | + | | | |
− | + | | | |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2009-06- | ||
− | | | ||
− | | An inspection of the | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
| 1046961243 | | 1046961243 | ||
| 2003-03-04 | | 2003-03-04 | ||
− | | | + | | |
| Follow-up on NOV, Non-Compliance, company has not rewrote ID or hung electric line. | | Follow-up on NOV, Non-Compliance, company has not rewrote ID or hung electric line. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1052748940 | | 1052748940 | ||
| 2003-05-06 | | 2003-05-06 | ||
− | | | + | | |
| Follow-up on NOV, In-Compliance. | | Follow-up on NOV, In-Compliance. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1075413650 | | 1075413650 | ||
| 2004-01-27 | | 2004-01-27 | ||
− | | | + | | |
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1078149911 | | 1078149911 | ||
| 2004-02-26 | | 2004-02-26 | ||
− | | | + | | |
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1092938833 | | 1092938833 | ||
| 2004-08-19 | | 2004-08-19 | ||
− | | | + | | |
| An inspection of the well revealed ID needs rewrote at well and tank battery, oily soil around storage tanks needs cleaned up. NEW LAT & LONG | | An inspection of the well revealed ID needs rewrote at well and tank battery, oily soil around storage tanks needs cleaned up. NEW LAT & LONG | ||
− | | | + | | |
− | | | + | | |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
|- | |- | ||
| 1154697983 | | 1154697983 | ||
| 2006-07-25 | | 2006-07-25 | ||
− | | | + | | |
| An inspection was conducted at the facility owned by Mr. Mark Schmelzer on 7/25/2006. During the inspection, it was noted that the injection line had a small pinhole leak in the injection line. As a result, brine was being discharged directly onto the ground surface. Also noted was that the surrounding area contained dead vegetation. Mrs. Gene Schmelzer was immediately contacted by telephone @11:15am on 7/25/2006. She was informed to correct this problem immediately. In regards to the SWIW inspection, it was found that a ID will be needed at the well. The ID the storage tanks contains the wrong area code. The dike needs to be pumped and the oily soil and material needs to be removed from the lease. On 7/28/2006, a follow-up inspection was conducted to ensure that the leaking fitting has been replaced. During the inspection, it was noted that the fitting was replaced and straw had been applied to the surrounding area. | | An inspection was conducted at the facility owned by Mr. Mark Schmelzer on 7/25/2006. During the inspection, it was noted that the injection line had a small pinhole leak in the injection line. As a result, brine was being discharged directly onto the ground surface. Also noted was that the surrounding area contained dead vegetation. Mrs. Gene Schmelzer was immediately contacted by telephone @11:15am on 7/25/2006. She was informed to correct this problem immediately. In regards to the SWIW inspection, it was found that a ID will be needed at the well. The ID the storage tanks contains the wrong area code. The dike needs to be pumped and the oily soil and material needs to be removed from the lease. On 7/28/2006, a follow-up inspection was conducted to ensure that the leaking fitting has been replaced. During the inspection, it was noted that the fitting was replaced and straw had been applied to the surrounding area. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1154992731 | | 1154992731 | ||
| 2006-07-28 | | 2006-07-28 | ||
− | | | + | | |
| During the insspection conducted on 7/28/2006, it was noted that the leaking injection fitting was replaced. Straw was applied to the surrounding area. | | During the insspection conducted on 7/28/2006, it was noted that the leaking injection fitting was replaced. Straw was applied to the surrounding area. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1168620032 | | 1168620032 | ||
| 2007-01-10 | | 2007-01-10 | ||
− | | | + | | |
| No violations were noted during the inspection. | | No violations were noted during the inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1173076558 | | 1173076558 | ||
| 2009-07-07 | | 2009-07-07 | ||
− | | | + | | |
| A follow-up inspection revealed compliance. | | A follow-up inspection revealed compliance. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1207012412 | | 1207012412 | ||
| 2008-03-31 | | 2008-03-31 | ||
− | | | + | | |
| A follow-up inspection conducted on saltwater drop tanks revealed that the trench has been filled, area graded and 100 bbl tanks removed. The elbow fitting that contained a small leak has been repaired. The company is removing abandoned steel flow lines and re-routing a section of the active flow line to the SWIW. Seed and mulch will be applied to the area. Contamination and pollution has been taken to the landfill. The wells tied into the drop tanks (saltwater) have been shut-down, until new tanks are installed and a dike has been constructed. | | A follow-up inspection conducted on saltwater drop tanks revealed that the trench has been filled, area graded and 100 bbl tanks removed. The elbow fitting that contained a small leak has been repaired. The company is removing abandoned steel flow lines and re-routing a section of the active flow line to the SWIW. Seed and mulch will be applied to the area. Contamination and pollution has been taken to the landfill. The wells tied into the drop tanks (saltwater) have been shut-down, until new tanks are installed and a dike has been constructed. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1211473626 | | 1211473626 | ||
| 2008-05-21 | | 2008-05-21 | ||
− | | | + | | |
| No violations | | No violations | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1221052423 | | 1221052423 | ||
| 2007-04-24 | | 2007-04-24 | ||
− | | | + | | |
| An inspection revealed that a new 1/4 inch valve is needed on the injection side of the well. | | An inspection revealed that a new 1/4 inch valve is needed on the injection side of the well. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1227268402 | ||
+ | | 2009-10-07 | ||
+ | | | ||
+ | | A follow-up inspection revealed non-compliance. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1231390251 | ||
+ | | 2008-03-07 | ||
+ | | | ||
+ | | A follow-up inspection was conducted at the Robertson SWIW. More cleanup will be needed inside the earthen impoundment located near the storage tanks. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1257863060 | | 1257863060 | ||
| 2009-11-10 | | 2009-11-10 | ||
− | | | + | | |
| A follow-up inspection revealed compliance. The earthen dike has been addressed, leaks stopped and location graded. | | A follow-up inspection revealed compliance. The earthen dike has been addressed, leaks stopped and location graded. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1259912222 | | 1259912222 | ||
| 2010-06-24 | | 2010-06-24 | ||
− | | | + | | |
| An inspection revealed no violations. | | An inspection revealed no violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1268765138 | | 1268765138 | ||
| 2010-03-16 | | 2010-03-16 | ||
− | | | + | | |
| An inspection revealed no violations at this time. The bbl counter at storage tank(s) location showed 224481. | | An inspection revealed no violations at this time. The bbl counter at storage tank(s) location showed 224481. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1269i1074 | | 1269i1074 | ||
| 2002-05-22 | | 2002-05-22 | ||
− | | | + | | |
| Follow-up on NOV, In-Compliance. Unable to check pressures on well , do not have tools to remove plugs in valves. | | Follow-up on NOV, In-Compliance. Unable to check pressures on well , do not have tools to remove plugs in valves. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1269i11751146 | | 1269i11751146 | ||
| 2001-03-27 | | 2001-03-27 | ||
− | | | + | | |
| No violations | | No violations | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1269i1398 | | 1269i1398 | ||
| 2002-09-24 | | 2002-09-24 | ||
− | | | + | | |
| No violations at this time. | | No violations at this time. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1269i210 | | 1269i210 | ||
| 2000-12-18 | | 2000-12-18 | ||
− | | | + | | |
| FOLLOW - UP ON NOV , IN - COMPLIANCE . | | FOLLOW - UP ON NOV , IN - COMPLIANCE . | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1269i513 | | 1269i513 | ||
| 2001-11-13 | | 2001-11-13 | ||
− | | | + | | |
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1269i698 | | 1269i698 | ||
| 2002-01-16 | | 2002-01-16 | ||
− | | | + | | |
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1269i87457142 | | 1269i87457142 | ||
| 2002-03-19 | | 2002-03-19 | ||
− | | | + | | |
| An inspection of the well revealed that the pump is leaking brine, the pump needs repaired or replaced. | | An inspection of the well revealed that the pump is leaking brine, the pump needs repaired or replaced. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1285691603 | | 1285691603 | ||
| 2010-09-27 | | 2010-09-27 | ||
− | | | + | | |
| An inspection revealed no violations. The barrel counter at storage tank location showed 224,481. Note: The gauge utilized for this inspection will require calibration. | | An inspection revealed no violations. The barrel counter at storage tank location showed 224,481. Note: The gauge utilized for this inspection will require calibration. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1314429500 | ||
+ | | 2009-03-03 | ||
+ | | | ||
+ | | An inspection revealed no violations at this time. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1316048722 | ||
+ | | 2009-09-02 | ||
+ | | | ||
+ | | An inspection revealed that general housekeeping has been performed at the tank battery location. The meter at the tank battery location showed 224481 bbl. Vegetative growth also observed, in patches, at the line break location. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1334681705 | | 1334681705 | ||
| 2012-04-16 | | 2012-04-16 | ||
− | | | + | | |
| Conducted an inspection on transfer pump facility off of Reed Rd. North of Logan. GPS coordinates N 39.56988, W 82.43575. Due to lack of vegetation, it was suspected that there had been a brine spill. Quantab results from a puddle of water in the vegetation kill area showed that the chloride content was too high for the Quantab to quantify. Mr. Danny Baker was notified by a phone call, and instructed to remediate soil where the vegetation was killed and build a containment dike around the pump because Mr. Baker had suspected it was leaking. He was also advised of other potential plumbing risks associated with the pump. Mr. Baker stated that he would be out there the following day with a piece of equipment to remediate situation. | | Conducted an inspection on transfer pump facility off of Reed Rd. North of Logan. GPS coordinates N 39.56988, W 82.43575. Due to lack of vegetation, it was suspected that there had been a brine spill. Quantab results from a puddle of water in the vegetation kill area showed that the chloride content was too high for the Quantab to quantify. Mr. Danny Baker was notified by a phone call, and instructed to remediate soil where the vegetation was killed and build a containment dike around the pump because Mr. Baker had suspected it was leaking. He was also advised of other potential plumbing risks associated with the pump. Mr. Baker stated that he would be out there the following day with a piece of equipment to remediate situation. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1346582948 | | 1346582948 | ||
| 2008-03-06 | | 2008-03-06 | ||
− | | | + | | |
| Witnessed a water truck pump out the trench containing brine. The company is transferring brine from the leaking tank to the Robertson SWIW. More fluid will need to be pumped out of the trench and tank will need to repaired or replaced. | | Witnessed a water truck pump out the trench containing brine. The company is transferring brine from the leaking tank to the Robertson SWIW. More fluid will need to be pumped out of the trench and tank will need to repaired or replaced. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1354714952 | | 1354714952 | ||
| 2012-12-04 | | 2012-12-04 | ||
− | | | + | | |
| The purpose of the inspection was to witness and injection line test. The company was not ready to perform the test when I arrived. They had detected a leak and were looking for it. Accompanied by Andrew Adgate and Steve riley. | | The purpose of the inspection was to witness and injection line test. The company was not ready to perform the test when I arrived. They had detected a leak and were looking for it. Accompanied by Andrew Adgate and Steve riley. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1358743542 | | 1358743542 | ||
| 2009-12-03 | | 2009-12-03 | ||
− | | | + | | |
| An inspection revealed no violations at this time. The meter at the tank battery location showed 224481 bbl. | | An inspection revealed no violations at this time. The meter at the tank battery location showed 224481 bbl. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 136248629 | | 136248629 | ||
| 2013-06-28 | | 2013-06-28 | ||
− | | | + | | |
| The dike is being rebuilt today, the plumbing where the leak was is also being repaired. | | The dike is being rebuilt today, the plumbing where the leak was is also being repaired. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1372851473 | | 1372851473 | ||
| 2013-07-02 | | 2013-07-02 | ||
− | | | + | | |
| Injection line pressure test. Tested steel line from surface facility to the well at 795 psi for 15 minutes with no loss in pressure. Inspector Kip Thompson witnessed Danny Baker open the master valve on the well head after the test. The gauge at the surface facility dropped from 795 psi to 20 psi when the master valve was opened. | | Injection line pressure test. Tested steel line from surface facility to the well at 795 psi for 15 minutes with no loss in pressure. Inspector Kip Thompson witnessed Danny Baker open the master valve on the well head after the test. The gauge at the surface facility dropped from 795 psi to 20 psi when the master valve was opened. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1378604987 | | 1378604987 | ||
| 2008-02-26 | | 2008-02-26 | ||
− | | | + | | |
| A follow-up inspection revealed non-compliance. | | A follow-up inspection revealed non-compliance. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1381422042 | ||
+ | | 2011-03-31 | ||
+ | | | ||
+ | | FOLLOW UP TO NOV # -1786451260 Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1403721816 | | 1403721816 | ||
| 2004-04-01 | | 2004-04-01 | ||
− | | | + | | |
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1407509652 | | 1407509652 | ||
| 2014-08-08 | | 2014-08-08 | ||
− | | | + | | |
| UIC inspection, I requested a MIT test to ensure their was no communication between the injection zone and the annulus. The test was held for 15 minutes for 305 PSI with no loss. | | UIC inspection, I requested a MIT test to ensure their was no communication between the injection zone and the annulus. The test was held for 15 minutes for 305 PSI with no loss. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1411064742 | ||
+ | | 2012-06-18 | ||
+ | | | ||
+ | | Accompanied by inspector Jon Scott. Observed what clean up had been performed. Bags filled with contaminated soil were still loaded on a roll back truck. Clean up had also been performed around vault where it had overflowed. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1413903286 | ||
+ | | 2014-10-21 | ||
+ | | | ||
+ | | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The containment vault lid was off. The fluid level in the vault was low. A new sump pump appears to have been installed. New identification was posted at the well. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1422457871 | ||
+ | | 2015-01-28 | ||
+ | | | ||
+ | | UIC inspection, the injection pressure was 11 PSI. The annulus pressure was 2 PSI. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1454207791 | | 1454207791 | ||
| 2009-10-14 | | 2009-10-14 | ||
− | | | + | | |
| A follow-up inspection revealed that the leaks have been addressed. Work has been done on earthen dike, but not completed. The location will also be graded. | | A follow-up inspection revealed that the leaks have been addressed. Work has been done on earthen dike, but not completed. The location will also be graded. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1509815397 | ||
+ | | 2012-08-20 | ||
+ | | | ||
+ | | Well and tank battery are in compliance. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1511436599 | | 1511436599 | ||
| 2014-01-09 | | 2014-01-09 | ||
− | | | + | | |
| Inspected the containment dike, tanks, injection line, Injection pressure, and annulus pressure. Identification posted on tank with-in the containment dike. Activity around the surface facility includes removal of a portion of fencing near the road, removal of debris and brush from inside remaining fenced area. New rolls of plastic pipe are on location. | | Inspected the containment dike, tanks, injection line, Injection pressure, and annulus pressure. Identification posted on tank with-in the containment dike. Activity around the surface facility includes removal of a portion of fencing near the road, removal of debris and brush from inside remaining fenced area. New rolls of plastic pipe are on location. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1554414865 | | 1554414865 | ||
| 2014-03-11 | | 2014-03-11 | ||
− | | | + | | |
| UIC inspection. I checked the injection well, the injection pressure was 0. The annulus pressure was 0. I contacted Danny Baker to conduct a 300 PSI mini test to ensure the annulus would hold pressure. | | UIC inspection. I checked the injection well, the injection pressure was 0. The annulus pressure was 0. I contacted Danny Baker to conduct a 300 PSI mini test to ensure the annulus would hold pressure. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1583357363 | ||
+ | | 2012-01-16 | ||
+ | | | ||
+ | | I received a phone call from Walter Borne at 10:25 am. He stated that the tank battery for this well was overflowing. I then placed a phone call to Danny Baker who is an employee of Jeanie Enterprises and told him what was going on. He said that he would go straight there and take care of it. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1588795722 | ||
+ | | 2012-12-05 | ||
+ | | | ||
+ | | There was nobody on site when I arrived. Called Danny Baker and he was on his way. One section of pipe still needed replaced on the injection line. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 161051084 | | 161051084 | ||
| 2004-12-14 | | 2004-12-14 | ||
− | | | + | | |
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1642470419 | | 1642470419 | ||
| 2004-05-27 | | 2004-05-27 | ||
− | | | + | | |
| No violations | | No violations | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1665678183 | | 1665678183 | ||
| 2012-01-25 | | 2012-01-25 | ||
− | | | + | | |
− | | Test 2 | + | | Test 2 steel injection line from the pump (in tank dike) to the salt water injection well. Tested at 850 pounds per square inch for 15 minutes with no loss. Opened master valve on injection tubing and witnessed pressure drop. Test passed. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1694141788 | ||
+ | | 2003-01-29 | ||
+ | | | ||
+ | | An inspection of the well revealed the ID needs REWOTE at the well and tanks, an electric line running along tank battery needs HUNG back up. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -174569852 | ||
+ | | 2013-06-27 | ||
+ | | | ||
+ | | Danny Baker has pumped out the dike. The dike was then removed to allow for the placement of a dike that will be liquid tight. They are plumbing the pump to eliminate the brine leak. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1776428409 | ||
+ | | 2011-08-31 | ||
+ | | | ||
+ | | Faded Identification at well. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1786451260 | ||
+ | | 2011-03-31 | ||
+ | | | ||
+ | | Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1796908120 | ||
+ | | 2012-06-13 | ||
+ | | | ||
+ | | I conducted an inspection on the transfer pump facility on Reed Rd with Jon Scott Inspector 3 South region. We found that there was a flow line leak at the pump at an elbow. It dripped once every 30 seconds. Mr. Danny Baker was notified of this immediately. He stated that he would be out to fix it promptly. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1880257932 | | 1880257932 | ||
| 2007-08-13 | | 2007-08-13 | ||
− | | | + | | |
| A follow-up inspection revealed that the well is in-compliance. | | A follow-up inspection revealed that the well is in-compliance. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1888650687 | ||
+ | | 2005-04-06 | ||
+ | | | ||
+ | | No violations. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1938055957 | ||
+ | | 2012-02-23 | ||
+ | | | ||
+ | | Injection pump operating during inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1939052819 | | 1939052819 | ||
| 2012-06-14 | | 2012-06-14 | ||
− | | | + | | |
| Checked on clean-up efforts performed by Mr. Danny Baker and company. Fluid had been absorbed and material bagged up and placed on a roll back truck. | | Checked on clean-up efforts performed by Mr. Danny Baker and company. Fluid had been absorbed and material bagged up and placed on a roll back truck. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1941229516 | | 1941229516 | ||
| 2014-03-13 | | 2014-03-13 | ||
− | | | + | | |
| Compliance notice follow-up. The pit has been rebuilt and the leaking pump has been rebuilt. This satisfies the compliance notice. | | Compliance notice follow-up. The pit has been rebuilt and the leaking pump has been rebuilt. This satisfies the compliance notice. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1956406417 | ||
+ | | 2009-06-10 | ||
+ | | | ||
+ | | The pumper for Jeanie Enterprises called at 3:20 PM and stated that 10 lb with lime, seed and mulch applied to line break location. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 2013704891 | | 2013704891 | ||
| 2012-04-17 | | 2012-04-17 | ||
− | | | + | | |
| Witnessed remedial work performed by Mr. Danny Baker on the transfer pump facility off of Reed Rd., Logan. | | Witnessed remedial work performed by Mr. Danny Baker on the transfer pump facility off of Reed Rd., Logan. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2032038049 | | 2032038049 | ||
| 2008-03-26 | | 2008-03-26 | ||
− | | | + | | |
| A follow-up inspection revealed that the cleanup has been performed around the storage tank location. The company will be providing a run ticket for contaminated soil. The previously noted violations have been resolved. | | A follow-up inspection revealed that the cleanup has been performed around the storage tank location. The company will be providing a run ticket for contaminated soil. The previously noted violations have been resolved. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -2080505699 | ||
+ | | 2015-04-02 | ||
+ | | | ||
+ | | UIC inspection. Baker Oilfield Services on site to perform a mini test. The test was held at 310 PSI for 15 minutes. Their was no loss in pressure for the duration of the test. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -2081099343 | ||
+ | | 2008-03-14 | ||
+ | | | ||
+ | | A follow-up inspection revealed non-compliance. C&P still observed at the storage tanks. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 2082007621 | | 2082007621 | ||
| 2008-03-21 | | 2008-03-21 | ||
− | | | + | | |
| A follow-up inspection revealed that cleanup has been performed around the unloading pad. It was noted that more work will be required around the earthen impoundment . | | A follow-up inspection revealed that cleanup has been performed around the unloading pad. It was noted that more work will be required around the earthen impoundment . | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2100817012 | | 2100817012 | ||
| 2012-11-27 | | 2012-11-27 | ||
− | | | + | | |
| There was a small amount of contamination inside the containment dike, and some general housekeeping needs performed on site. Left a message on Mr. Danny Baker's phone to make him aware of this. Everything else is in compliance. Spoke with Mr. Baker later on on Wednesday 11/28/12 at 8:47 am and he agreed to cleaning the site up. He stated that he had plans to do so anyway. | | There was a small amount of contamination inside the containment dike, and some general housekeeping needs performed on site. Left a message on Mr. Danny Baker's phone to make him aware of this. Everything else is in compliance. Spoke with Mr. Baker later on on Wednesday 11/28/12 at 8:47 am and he agreed to cleaning the site up. He stated that he had plans to do so anyway. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -2115776822 | ||
+ | | 2013-04-10 | ||
+ | | | ||
+ | | UIC training with Jon Scott, see Jon Scotts report for details. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 2145792277 | | 2145792277 | ||
| 2003-10-27 | | 2003-10-27 | ||
− | | | + | | |
| No violations | | No violations | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 236826559 | | 236826559 | ||
| 2008-03-06 | | 2008-03-06 | ||
− | | | + | | |
| An inspection revealed that one of the two 100 bbl saltwater drop tanks (located on Reed Road) was corroded and leaking at the bottom. A large trench located at a lower elevation serves as a catch basin. Fluid inside this trench was observed draining into a nearby creek. Quantabs (high range) showed 10 units near the source of the leak and location where the fluid drains into the creek. A new 100 bbl tank was observed at the entrance to the lease road. Contacted the owner, Jeanie Schmeltzer and pumper for the company. They were informed to resolve this issue immediately. The company states that they will have a water truck pump the trench today. And the fluid inside the leaking tank will be transferred over to the injection well. The pumper states that they found this leak on the 3/5/2008. A new 100 bbl tank was observed on-site. Dennis Deavers with OEPA was informed of the inspection results. | | An inspection revealed that one of the two 100 bbl saltwater drop tanks (located on Reed Road) was corroded and leaking at the bottom. A large trench located at a lower elevation serves as a catch basin. Fluid inside this trench was observed draining into a nearby creek. Quantabs (high range) showed 10 units near the source of the leak and location where the fluid drains into the creek. A new 100 bbl tank was observed at the entrance to the lease road. Contacted the owner, Jeanie Schmeltzer and pumper for the company. They were informed to resolve this issue immediately. The company states that they will have a water truck pump the trench today. And the fluid inside the leaking tank will be transferred over to the injection well. The pumper states that they found this leak on the 3/5/2008. A new 100 bbl tank was observed on-site. Dennis Deavers with OEPA was informed of the inspection results. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -259096746 |
− | | | + | | 2010-12-28 |
− | | | + | | |
− | | An inspection revealed | + | | An inspection revealed no violations. The meter showed no change as 224481 bbls were observed. Snow cover at time of inspection. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -267787825 |
− | | 2008- | + | | 2008-09-08 |
− | | | + | | |
− | | An inspection revealed | + | | An inspection revealed no identification at the storage tanks. The identification card placed at the well was found to contain only the previous companies name. No additional information was observed. Identification was not observed at the storage tanks. Contamination and pollution was observed at the unloading pad. The company was contacted by telephone and informed of the inspection results. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | 291345184 |
− | | | + | | 2013-04-10 |
− | | | + | | |
− | | | + | | Injection line test. Attempted to test injection line two times. A leak was found on a 2 union. The leak was not able to be repaired during the inspection. The line test will be rescheduled after repairs are made. No injection until the line is tested and passed. Inspector Kip Thompson accompanied me on the test. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -330363311 |
− | | | + | | 2005-03-03 |
− | | | + | | |
− | | | + | | No violations. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 379760063 | | 379760063 | ||
| 2013-07-11 | | 2013-07-11 | ||
− | | | + | | |
| Danny Baker has rebuilt the dike and repaired the plumbing on the pump. The leaks have been fixed and the dike has been rebuilt with clay from Logan clay. This satisfies the compliance notice. | | Danny Baker has rebuilt the dike and repaired the plumbing on the pump. The leaks have been fixed and the dike has been rebuilt with clay from Logan clay. This satisfies the compliance notice. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -472394746 |
− | | | + | | 2005-06-09 |
− | | | + | | |
− | | | + | | No violations |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 479843378 | | 479843378 | ||
| 2008-02-11 | | 2008-02-11 | ||
− | | | + | | |
| An inspection revealed that a 210 bbl storage tank has overflowed onto the ground surface. The impacted areas ranged from 1-2 ft sections outside the concrete dike placed around the storage tanks,and a 10x20ft section around the unloading pad. An earthen impoundment was also found to be impacted. A 5x3 ft section of oil was observed. This source of water containment does not lead to a creek or stream. Equipment (mini excavator) and cleanup supplies were observed on-site. Also noted was that new identification would be needed at the well head. The company, Jeanie Enterprises, and the pumper, Mr. Danny Baker, were both contacted and informed of inspection results. Mr. Baker states that they have been working on cleanup and have taken oily soils to the landfill and will provide run tickets. He was informed that the impoundment will also need to be addressed along with the areas outside the dike. | | An inspection revealed that a 210 bbl storage tank has overflowed onto the ground surface. The impacted areas ranged from 1-2 ft sections outside the concrete dike placed around the storage tanks,and a 10x20ft section around the unloading pad. An earthen impoundment was also found to be impacted. A 5x3 ft section of oil was observed. This source of water containment does not lead to a creek or stream. Equipment (mini excavator) and cleanup supplies were observed on-site. Also noted was that new identification would be needed at the well head. The company, Jeanie Enterprises, and the pumper, Mr. Danny Baker, were both contacted and informed of inspection results. Mr. Baker states that they have been working on cleanup and have taken oily soils to the landfill and will provide run tickets. He was informed that the impoundment will also need to be addressed along with the areas outside the dike. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 488943911 | | 488943911 | ||
| 2013-01-10 | | 2013-01-10 | ||
− | | | + | | |
| Inspected salt water injection well injection tubing pressure and annulus pressure. Good identification at well head. Steel injection line has been installed in an open ditch. Currently waiting on company to test the injection line from the tank battery to the well. Injection operations are shut down waiting on the line test and the replacement of the brine pump. Accompanied by Andy Thomas MRI 2. | | Inspected salt water injection well injection tubing pressure and annulus pressure. Good identification at well head. Steel injection line has been installed in an open ditch. Currently waiting on company to test the injection line from the tank battery to the well. Injection operations are shut down waiting on the line test and the replacement of the brine pump. Accompanied by Andy Thomas MRI 2. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -519295457 | ||
+ | | 2003-06-19 | ||
+ | | | ||
+ | | No violations. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -525601398 | ||
+ | | 2012-01-17 | ||
+ | | | ||
+ | | When I arrived at the tank battery, the injection pump was running. I immediately called Danny Baker and told him that an injection line test needed to be administered, and witnessed by the state before he could run the pump. This test was supposed to have taken place in the summer of 2011. I was then joined by Jon Scott south region UIC inspector. When Danny Baker arrived with his crew, two attempts were made to test the flow line. Both had failed. Inspector Kip Thompson was also present on this inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 543640086 | | 543640086 | ||
| 2012-06-13 | | 2012-06-13 | ||
− | | | + | | |
| Concrete containment at the tank battery was full of fluid. The vault was also full and had appeared to had flown over. Mr. Danny Baker was called immediately. He stated that he would be out promptly to take care of the situation. He also stated that the problem was due to a tank overflow. We agreed that absobant material would be used to soak fluid up and then material would be shoveled out an hauled to an approved landfill. I checked back later on the same day and the vault had been pumped out. | | Concrete containment at the tank battery was full of fluid. The vault was also full and had appeared to had flown over. Mr. Danny Baker was called immediately. He stated that he would be out promptly to take care of the situation. He also stated that the problem was due to a tank overflow. We agreed that absobant material would be used to soak fluid up and then material would be shoveled out an hauled to an approved landfill. I checked back later on the same day and the vault had been pumped out. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 5609i211 | | 5609i211 | ||
| 2001-06-04 | | 2001-06-04 | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -565489822 | ||
+ | | 2012-06-18 | ||
+ | | | ||
+ | | Follow up with Andy Thomas MRI 2 at dike. Oil spill in dike has been cleaned up. Dike is free of oil. No oil on the ground near the concrete vault. Brine contaminated soil has not been removed. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -574483130 | ||
+ | | 2008-10-30 | ||
+ | | | ||
+ | | A follow-up inspection revealed that the violations have been resolved. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -576223882 | ||
+ | | 2007-06-20 | ||
+ | | | ||
+ | | A follow-up inspection revealed non-compliance. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 584529606 | | 584529606 | ||
| 2011-12-15 | | 2011-12-15 | ||
− | | | + | | |
| Accompanied by Andy Thomas MRI. New identification at wellhead has fallen on the ground. | | Accompanied by Andy Thomas MRI. New identification at wellhead has fallen on the ground. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -632427697 | ||
+ | | 2013-01-10 | ||
+ | | | ||
+ | | Checked injection and annulus pressures at the well. A trench had been dug and new injection line had been laid in it. We are still awaiting an injection line test. Well was not injecting at the time of inspection. Accompanied by Jon Scott. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 6591978 | | 6591978 | ||
| 2011-12-15 | | 2011-12-15 | ||
− | | | + | | |
| Accompanied Jon Scott on inspection. | | Accompanied Jon Scott on inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -688348716 |
− | | | + | | 2008-03-20 |
− | | | + | | |
− | | | + | | A follow-up inspection revealed non-compliance. More work needed around the drop tank location. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 705372691 | | 705372691 | ||
| 2013-06-26 | | 2013-06-26 | ||
− | | | + | | |
| I conducted a inspection of the lift pump station. This pump lifts brine to flow to their injection well. The fittings on the pump are leaking, the brine is being collected in a pit. The pit is not liquid tight allowing brine to leach thru. I sampled the brine using high range chloride titrators. I sampled two areas both samples registered 2400 PPM chlorides. Mark Smeltzer shut the pump off at 1322 hours. I asked the pump not be used until the leak is corrected and the dike is made liquid tight. The pumping station is located on reed road. | | I conducted a inspection of the lift pump station. This pump lifts brine to flow to their injection well. The fittings on the pump are leaking, the brine is being collected in a pit. The pit is not liquid tight allowing brine to leach thru. I sampled the brine using high range chloride titrators. I sampled two areas both samples registered 2400 PPM chlorides. Mark Smeltzer shut the pump off at 1322 hours. I asked the pump not be used until the leak is corrected and the dike is made liquid tight. The pumping station is located on reed road. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 754870566 | | 754870566 | ||
| 2004-09-24 | | 2004-09-24 | ||
− | | | + | | |
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -774978176 | ||
+ | | 2015-03-24 | ||
+ | | | ||
+ | | UIC inspection, there is some oil and water in the dike. I called Danny Baker to have the dike pumped out. The injection well has 12 PSI on the injection side, the annulus has 0 pressure. I have contacted Jeanie Enterprises to perform a mini test. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -780999638 | ||
+ | | 2003-12-09 | ||
+ | | | ||
+ | | No violations. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -818713486 | ||
+ | | 2009-06-02 | ||
+ | | | ||
+ | | An inspection of the SWIW and related storage tanks was conducted with Mr. Jeff Fry. During the inspection, an old bare area with exposed flowline were observed below the storage tanks located in a low lying area near the creek. Note: Timber has been removed from this locaton, but signs of stressed vegetation were noted. It was also noted that general housekeeping would be needed at the unloading pad/concrete vault location. Old oil found around the concrete vault and appeared to be breaking down. Old filters along with a drum containing oily debris, which may have leaked would need to be placed inside dike to avoid leakage. At the time of the inspection, the meter showed 224,481 bbls. Left voice mail message for the pumper, Mr. Danny Baker with Jeanie Enterprises on 6/2/2009 at 2:12 pm, in regards to the inspection. Mr. Baker returned call on 6/3/2009 and confirmed line break over the hill last year. Mr. Baker was instructed to place lime, seed and mulch on the impacted area. Perform general housekeeping and recommended filters and drum placed inside dike. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -822760495 | ||
+ | | 2007-10-30 | ||
+ | | | ||
+ | | No violations were noted. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
− | | | + | | -83402969 |
− | | | + | | 2013-07-02 |
− | | | + | | |
− | | | + | | I accompanied Jon Scott for a line test. The test passed, see Jons report dated 07/02/2013 for results. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 849615643 | | 849615643 | ||
| 2009-10-01 | | 2009-10-01 | ||
− | | | + | | |
− | | An inspection of the saltwater drop or pump station to Roberston (SWIW #1) was conducted. The facility contains only one (1) 100 bbl. The second 100 bbl that contained a hole and was leaking has now been removed. Currently, the existing 100 bbl contains a leak (approx 1 drip every 10 sec) on bottom at valve with swage before connection to PVC elbow fitting. A rag has been placed around the leak. High Range Quantabs exceeded 10 units of Cl-. Note: 8.4 units equals 6545 ppm (mg/L) of Cl-. The attached line is 2 | + | | An inspection of the saltwater drop or pump station to Roberston (SWIW #1) was conducted. The facility contains only one (1) 100 bbl. The second 100 bbl that contained a hole and was leaking has now been removed. Currently, the existing 100 bbl contains a leak (approx 1 drip every 10 sec) on bottom at valve with swage before connection to PVC elbow fitting. A rag has been placed around the leak. High Range Quantabs exceeded 10 units of Cl-. Note: 8.4 units equals 6545 ppm (mg/L) of Cl-. The attached line is 2 Sch 40 PVC pipe routed to pump house (inlet). A leak was also observed at this location (inlet to pump). 1 drip approx every 60 seconds. The outlet is 2 steel from pump house uphill to SWIW. Old oil observed a pump house with wood chips placed around location. The oil came derives from a rotted steel line that had been repaired. Wash from rainfall events drains from location (pump house and tank) to creek approx 30' and 10' away respectively. The earthen dike around 100bbl tank contains a trench. The pumper, Mr. Danny Baker arrived at location during inspection. He was instructed of deficiencies and made attempt to stop leaks. Mr. Baker states cleanup, dike and water diversion will be done next week. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 855206324 | | 855206324 | ||
| 2013-09-03 | | 2013-09-03 | ||
− | | | + | | |
| UIC inspection, the injection well was not in use. The well was being worked on, the filter canister was being repaired. | | UIC inspection, the injection well was not in use. The well was being worked on, the filter canister was being repaired. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -858432577 | ||
+ | | 2008-03-13 | ||
+ | | | ||
+ | | A follow-up inspection regarding the leak from a saltwater drop tank (Reed Road) revealed non-compliance. The fluid inside the trench showed 3.8 units on Quantabs (High Range), but was not discharging into the creek. More fluid will need to be pumped from this trench. An elbow fitting, on a steel flow line, that crosses the creek was observed to contain a small leak. Quantab showed maximum of 10 units. The company was contacted and informed of the inspection results. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -889993238 | ||
+ | | 2012-01-25 | ||
+ | | | ||
+ | | I witnessed the injection line test with inspectors Jon Scott and Kip Thompson. The line held 840 pounds of pressure for 15 minutes. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -902937421 | ||
+ | | 2006-09-21 | ||
+ | | | ||
+ | | A follow-up inspection was conducted at the facility owned by Mr. Mark Schmelzer on 9/21/2006. During the inspection, it was noted that the previously noted violations have been resolved. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -933669370 | ||
+ | | 2012-06-20 | ||
+ | | | ||
+ | | Inspected transfer pump facility off of Reed Rd. A new piece of pipe had been installed where the old one had been leaking. No leak detected. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 934148653 | | 934148653 | ||
| 2008-02-25 | | 2008-02-25 | ||
− | | | + | | |
| A follow-up inspection revealed that company has been performing cleanup. However, more work will be needed. | | A follow-up inspection revealed that company has been performing cleanup. However, more work will be needed. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 963089080 | | 963089080 | ||
| 2014-07-30 | | 2014-07-30 | ||
− | | | + | | |
| Saltwater injection well inspection. The injection pressure was 28 PSI, the annulus pressure was 0 PSI. I have contacted Danny Baker to conduct a mini test to ensure casing integrity. | | Saltwater injection well inspection. The injection pressure was 28 PSI, the annulus pressure was 0 PSI. I have contacted Danny Baker to conduct a mini test to ensure casing integrity. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -987799875 |
− | | | + | | 2003-07-24 |
− | | | + | | |
− | | | + | | No violations |
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -994351388 | ||
+ | | 2012-01-17 | ||
+ | | | ||
+ | | 1-16-12 Received call from Andy Thomas MRI, that a brine tank had flowed over and into the dike. 1-17-12 made arrangements to meet at tank battery. The tanks had been recently wiped down and the dike had been cleaned out. The spill was contained with in the dike. The injection line from the pump to the injection well has been worked on recently and I requested that they test the line to show mechanical integrity. Two attempts were made to test the injection line. Both attempts were unsuccessful. The pumper requested that they shut down the injection and make repairs to the line on the 1-18-12 then re-test on 1-19-12. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| iTOMK000077 | | iTOMK000077 | ||
| 2000-08-01 | | 2000-08-01 | ||
− | | | + | | |
| SWIW#1 | | SWIW#1 | ||
− | | | + | | |
− | | | + | | |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
|- | |- | ||
| iTOMK000098 | | iTOMK000098 | ||
| 2000-11-15 | | 2000-11-15 | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| UIC60 | | UIC60 | ||
| 1987-01-05 | | 1987-01-05 | ||
− | | | + | | |
| 1501:9-3-07(H) | | 1501:9-3-07(H) | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| UIC61 | | UIC61 | ||
| 1987-01-05 | | 1987-01-05 | ||
− | | | + | | |
| 1501:9-3-04(A) | | 1501:9-3-04(A) | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| UIC62 | | UIC62 | ||
| 1987-01-05 | | 1987-01-05 | ||
− | | | + | | |
| 1501:9-3-05(B)(7) | | 1501:9-3-05(B)(7) | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Ohio Department of Natural Resources RBDMS | ||
+ | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
+ | | date = 2015-06-19 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection | ||
+ | | accessdate = 2015-06-20 }}</ref> | ||
+ | == References == | ||
+ | {{reflist}} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] |
Well ID: 34-073-22161 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.55619356,"lon":-82.45354214,"icon":""}]} |
County: Hocking | |
Municipality: | |
Operator Name: JEANIE ENTERPISES LLC | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1979-08-11 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Active Injection | |
Violations: 0 | |
Latitude: 39.55619356 | |
Longitude: -82.45354214 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1988-0 | 0.0 | 0.0 | ||||
1991-0 | 0.0 | 0.0 | ||||
2004-0 | 0.0 | 0.0 | ||||
2005-0 | 0.0 | 0.0 | ||||
2006-0 | 0.0 | 0.0 | ||||
2008-0 | 0.0 | 0.0 | ||||
2009-0 | 0.0 | 0.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Compliance Notice | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Compliance Notice | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Phone Call | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Compliance Notice | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Compliance Notice | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Field Visit or Inspection | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Compliance Notice | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Compliance Notice | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Compliance Notice | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Phone Call | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Phone Call | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Phone Call | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Field Visit or Inspection | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | ||||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Phone Call | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | Field Visit or Inspection | |||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | ||||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | ||||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | ||||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | ||||
-1035524058 | 2009-06-16 | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50' x 50' area. Note: Company employee states that line broke in Fall 2008. | ||||
1046961243 | 2003-03-04 | Follow-up on NOV, Non-Compliance, company has not rewrote ID or hung electric line. | ||||
1052748940 | 2003-05-06 | Follow-up on NOV, In-Compliance. | ||||
1075413650 | 2004-01-27 | No violations. | ||||
1078149911 | 2004-02-26 | No violations. | ||||
1092938833 | 2004-08-19 | An inspection of the well revealed ID needs rewrote at well and tank battery, oily soil around storage tanks needs cleaned up. NEW LAT & LONG | ||||
1154697983 | 2006-07-25 | An inspection was conducted at the facility owned by Mr. Mark Schmelzer on 7/25/2006. During the inspection, it was noted that the injection line had a small pinhole leak in the injection line. As a result, brine was being discharged directly onto the ground surface. Also noted was that the surrounding area contained dead vegetation. Mrs. Gene Schmelzer was immediately contacted by telephone @11:15am on 7/25/2006. She was informed to correct this problem immediately. In regards to the SWIW inspection, it was found that a ID will be needed at the well. The ID the storage tanks contains the wrong area code. The dike needs to be pumped and the oily soil and material needs to be removed from the lease. On 7/28/2006, a follow-up inspection was conducted to ensure that the leaking fitting has been replaced. During the inspection, it was noted that the fitting was replaced and straw had been applied to the surrounding area. | ||||
1154992731 | 2006-07-28 | During the insspection conducted on 7/28/2006, it was noted that the leaking injection fitting was replaced. Straw was applied to the surrounding area. | ||||
1168620032 | 2007-01-10 | No violations were noted during the inspection. | ||||
1173076558 | 2009-07-07 | A follow-up inspection revealed compliance. | ||||
1207012412 | 2008-03-31 | A follow-up inspection conducted on saltwater drop tanks revealed that the trench has been filled, area graded and 100 bbl tanks removed. The elbow fitting that contained a small leak has been repaired. The company is removing abandoned steel flow lines and re-routing a section of the active flow line to the SWIW. Seed and mulch will be applied to the area. Contamination and pollution has been taken to the landfill. The wells tied into the drop tanks (saltwater) have been shut-down, until new tanks are installed and a dike has been constructed. | ||||
1211473626 | 2008-05-21 | No violations | ||||
1221052423 | 2007-04-24 | An inspection revealed that a new 1/4 inch valve is needed on the injection side of the well. | ||||
-1227268402 | 2009-10-07 | A follow-up inspection revealed non-compliance. | ||||
-1231390251 | 2008-03-07 | A follow-up inspection was conducted at the Robertson SWIW. More cleanup will be needed inside the earthen impoundment located near the storage tanks. | ||||
1257863060 | 2009-11-10 | A follow-up inspection revealed compliance. The earthen dike has been addressed, leaks stopped and location graded. | ||||
1259912222 | 2010-06-24 | An inspection revealed no violations. | ||||
1268765138 | 2010-03-16 | An inspection revealed no violations at this time. The bbl counter at storage tank(s) location showed 224481. | ||||
1269i1074 | 2002-05-22 | Follow-up on NOV, In-Compliance. Unable to check pressures on well , do not have tools to remove plugs in valves. | ||||
1269i11751146 | 2001-03-27 | No violations | ||||
1269i1398 | 2002-09-24 | No violations at this time. | ||||
1269i210 | 2000-12-18 | FOLLOW - UP ON NOV , IN - COMPLIANCE . | ||||
1269i513 | 2001-11-13 | No violations. | ||||
1269i698 | 2002-01-16 | No violations. | ||||
1269i87457142 | 2002-03-19 | An inspection of the well revealed that the pump is leaking brine, the pump needs repaired or replaced. | ||||
1285691603 | 2010-09-27 | An inspection revealed no violations. The barrel counter at storage tank location showed 224,481. Note: The gauge utilized for this inspection will require calibration. | ||||
-1314429500 | 2009-03-03 | An inspection revealed no violations at this time. | ||||
-1316048722 | 2009-09-02 | An inspection revealed that general housekeeping has been performed at the tank battery location. The meter at the tank battery location showed 224481 bbl. Vegetative growth also observed, in patches, at the line break location. | ||||
1334681705 | 2012-04-16 | Conducted an inspection on transfer pump facility off of Reed Rd. North of Logan. GPS coordinates N 39.56988, W 82.43575. Due to lack of vegetation, it was suspected that there had been a brine spill. Quantab results from a puddle of water in the vegetation kill area showed that the chloride content was too high for the Quantab to quantify. Mr. Danny Baker was notified by a phone call, and instructed to remediate soil where the vegetation was killed and build a containment dike around the pump because Mr. Baker had suspected it was leaking. He was also advised of other potential plumbing risks associated with the pump. Mr. Baker stated that he would be out there the following day with a piece of equipment to remediate situation. | ||||
1346582948 | 2008-03-06 | Witnessed a water truck pump out the trench containing brine. The company is transferring brine from the leaking tank to the Robertson SWIW. More fluid will need to be pumped out of the trench and tank will need to repaired or replaced. | ||||
1354714952 | 2012-12-04 | The purpose of the inspection was to witness and injection line test. The company was not ready to perform the test when I arrived. They had detected a leak and were looking for it. Accompanied by Andrew Adgate and Steve riley. | ||||
1358743542 | 2009-12-03 | An inspection revealed no violations at this time. The meter at the tank battery location showed 224481 bbl. | ||||
136248629 | 2013-06-28 | The dike is being rebuilt today, the plumbing where the leak was is also being repaired. | ||||
1372851473 | 2013-07-02 | Injection line pressure test. Tested steel line from surface facility to the well at 795 psi for 15 minutes with no loss in pressure. Inspector Kip Thompson witnessed Danny Baker open the master valve on the well head after the test. The gauge at the surface facility dropped from 795 psi to 20 psi when the master valve was opened. | ||||
1378604987 | 2008-02-26 | A follow-up inspection revealed non-compliance. | ||||
-1381422042 | 2011-03-31 | FOLLOW UP TO NOV # -1786451260 Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break. | ||||
1403721816 | 2004-04-01 | No violations. | ||||
1407509652 | 2014-08-08 | UIC inspection, I requested a MIT test to ensure their was no communication between the injection zone and the annulus. The test was held for 15 minutes for 305 PSI with no loss. | ||||
-1411064742 | 2012-06-18 | Accompanied by inspector Jon Scott. Observed what clean up had been performed. Bags filled with contaminated soil were still loaded on a roll back truck. Clean up had also been performed around vault where it had overflowed. | ||||
1413903286 | 2014-10-21 | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The containment vault lid was off. The fluid level in the vault was low. A new sump pump appears to have been installed. New identification was posted at the well. | ||||
1422457871 | 2015-01-28 | UIC inspection, the injection pressure was 11 PSI. The annulus pressure was 2 PSI. | ||||
1454207791 | 2009-10-14 | A follow-up inspection revealed that the leaks have been addressed. Work has been done on earthen dike, but not completed. The location will also be graded. | ||||
-1509815397 | 2012-08-20 | Well and tank battery are in compliance. | ||||
1511436599 | 2014-01-09 | Inspected the containment dike, tanks, injection line, Injection pressure, and annulus pressure. Identification posted on tank with-in the containment dike. Activity around the surface facility includes removal of a portion of fencing near the road, removal of debris and brush from inside remaining fenced area. New rolls of plastic pipe are on location. | ||||
1554414865 | 2014-03-11 | UIC inspection. I checked the injection well, the injection pressure was 0. The annulus pressure was 0. I contacted Danny Baker to conduct a 300 PSI mini test to ensure the annulus would hold pressure. | ||||
-1583357363 | 2012-01-16 | I received a phone call from Walter Borne at 10:25 am. He stated that the tank battery for this well was overflowing. I then placed a phone call to Danny Baker who is an employee of Jeanie Enterprises and told him what was going on. He said that he would go straight there and take care of it. | ||||
-1588795722 | 2012-12-05 | There was nobody on site when I arrived. Called Danny Baker and he was on his way. One section of pipe still needed replaced on the injection line. | ||||
161051084 | 2004-12-14 | No violations. | ||||
1642470419 | 2004-05-27 | No violations | ||||
1665678183 | 2012-01-25 | Test 2 steel injection line from the pump (in tank dike) to the salt water injection well. Tested at 850 pounds per square inch for 15 minutes with no loss. Opened master valve on injection tubing and witnessed pressure drop. Test passed. | ||||
-1694141788 | 2003-01-29 | An inspection of the well revealed the ID needs REWOTE at the well and tanks, an electric line running along tank battery needs HUNG back up. | ||||
-174569852 | 2013-06-27 | Danny Baker has pumped out the dike. The dike was then removed to allow for the placement of a dike that will be liquid tight. They are plumbing the pump to eliminate the brine leak. | ||||
-1776428409 | 2011-08-31 | Faded Identification at well. | ||||
-1786451260 | 2011-03-31 | Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break. | ||||
-1796908120 | 2012-06-13 | I conducted an inspection on the transfer pump facility on Reed Rd with Jon Scott Inspector 3 South region. We found that there was a flow line leak at the pump at an elbow. It dripped once every 30 seconds. Mr. Danny Baker was notified of this immediately. He stated that he would be out to fix it promptly. | ||||
1880257932 | 2007-08-13 | A follow-up inspection revealed that the well is in-compliance. | ||||
-1888650687 | 2005-04-06 | No violations. | ||||
-1938055957 | 2012-02-23 | Injection pump operating during inspection. | ||||
1939052819 | 2012-06-14 | Checked on clean-up efforts performed by Mr. Danny Baker and company. Fluid had been absorbed and material bagged up and placed on a roll back truck. | ||||
1941229516 | 2014-03-13 | Compliance notice follow-up. The pit has been rebuilt and the leaking pump has been rebuilt. This satisfies the compliance notice. | ||||
-1956406417 | 2009-06-10 | The pumper for Jeanie Enterprises called at 3:20 PM and stated that 10 lb with lime, seed and mulch applied to line break location. | ||||
2013704891 | 2012-04-17 | Witnessed remedial work performed by Mr. Danny Baker on the transfer pump facility off of Reed Rd., Logan. | ||||
2032038049 | 2008-03-26 | A follow-up inspection revealed that the cleanup has been performed around the storage tank location. The company will be providing a run ticket for contaminated soil. The previously noted violations have been resolved. | ||||
-2080505699 | 2015-04-02 | UIC inspection. Baker Oilfield Services on site to perform a mini test. The test was held at 310 PSI for 15 minutes. Their was no loss in pressure for the duration of the test. | ||||
-2081099343 | 2008-03-14 | A follow-up inspection revealed non-compliance. C&P still observed at the storage tanks. | ||||
2082007621 | 2008-03-21 | A follow-up inspection revealed that cleanup has been performed around the unloading pad. It was noted that more work will be required around the earthen impoundment . | ||||
2100817012 | 2012-11-27 | There was a small amount of contamination inside the containment dike, and some general housekeeping needs performed on site. Left a message on Mr. Danny Baker's phone to make him aware of this. Everything else is in compliance. Spoke with Mr. Baker later on on Wednesday 11/28/12 at 8:47 am and he agreed to cleaning the site up. He stated that he had plans to do so anyway. | ||||
-2115776822 | 2013-04-10 | UIC training with Jon Scott, see Jon Scotts report for details. | ||||
2145792277 | 2003-10-27 | No violations | ||||
236826559 | 2008-03-06 | An inspection revealed that one of the two 100 bbl saltwater drop tanks (located on Reed Road) was corroded and leaking at the bottom. A large trench located at a lower elevation serves as a catch basin. Fluid inside this trench was observed draining into a nearby creek. Quantabs (high range) showed 10 units near the source of the leak and location where the fluid drains into the creek. A new 100 bbl tank was observed at the entrance to the lease road. Contacted the owner, Jeanie Schmeltzer and pumper for the company. They were informed to resolve this issue immediately. The company states that they will have a water truck pump the trench today. And the fluid inside the leaking tank will be transferred over to the injection well. The pumper states that they found this leak on the 3/5/2008. A new 100 bbl tank was observed on-site. Dennis Deavers with OEPA was informed of the inspection results. | ||||
-259096746 | 2010-12-28 | An inspection revealed no violations. The meter showed no change as 224481 bbls were observed. Snow cover at time of inspection. | ||||
-267787825 | 2008-09-08 | An inspection revealed no identification at the storage tanks. The identification card placed at the well was found to contain only the previous companies name. No additional information was observed. Identification was not observed at the storage tanks. Contamination and pollution was observed at the unloading pad. The company was contacted by telephone and informed of the inspection results. | ||||
291345184 | 2013-04-10 | Injection line test. Attempted to test injection line two times. A leak was found on a 2 union. The leak was not able to be repaired during the inspection. The line test will be rescheduled after repairs are made. No injection until the line is tested and passed. Inspector Kip Thompson accompanied me on the test. | ||||
-330363311 | 2005-03-03 | No violations. | ||||
379760063 | 2013-07-11 | Danny Baker has rebuilt the dike and repaired the plumbing on the pump. The leaks have been fixed and the dike has been rebuilt with clay from Logan clay. This satisfies the compliance notice. | ||||
-472394746 | 2005-06-09 | No violations | ||||
479843378 | 2008-02-11 | An inspection revealed that a 210 bbl storage tank has overflowed onto the ground surface. The impacted areas ranged from 1-2 ft sections outside the concrete dike placed around the storage tanks,and a 10x20ft section around the unloading pad. An earthen impoundment was also found to be impacted. A 5x3 ft section of oil was observed. This source of water containment does not lead to a creek or stream. Equipment (mini excavator) and cleanup supplies were observed on-site. Also noted was that new identification would be needed at the well head. The company, Jeanie Enterprises, and the pumper, Mr. Danny Baker, were both contacted and informed of inspection results. Mr. Baker states that they have been working on cleanup and have taken oily soils to the landfill and will provide run tickets. He was informed that the impoundment will also need to be addressed along with the areas outside the dike. | ||||
488943911 | 2013-01-10 | Inspected salt water injection well injection tubing pressure and annulus pressure. Good identification at well head. Steel injection line has been installed in an open ditch. Currently waiting on company to test the injection line from the tank battery to the well. Injection operations are shut down waiting on the line test and the replacement of the brine pump. Accompanied by Andy Thomas MRI 2. | ||||
-519295457 | 2003-06-19 | No violations. | ||||
-525601398 | 2012-01-17 | When I arrived at the tank battery, the injection pump was running. I immediately called Danny Baker and told him that an injection line test needed to be administered, and witnessed by the state before he could run the pump. This test was supposed to have taken place in the summer of 2011. I was then joined by Jon Scott south region UIC inspector. When Danny Baker arrived with his crew, two attempts were made to test the flow line. Both had failed. Inspector Kip Thompson was also present on this inspection. | ||||
543640086 | 2012-06-13 | Concrete containment at the tank battery was full of fluid. The vault was also full and had appeared to had flown over. Mr. Danny Baker was called immediately. He stated that he would be out promptly to take care of the situation. He also stated that the problem was due to a tank overflow. We agreed that absobant material would be used to soak fluid up and then material would be shoveled out an hauled to an approved landfill. I checked back later on the same day and the vault had been pumped out. | ||||
5609i211 | 2001-06-04 | |||||
-565489822 | 2012-06-18 | Follow up with Andy Thomas MRI 2 at dike. Oil spill in dike has been cleaned up. Dike is free of oil. No oil on the ground near the concrete vault. Brine contaminated soil has not been removed. | ||||
-574483130 | 2008-10-30 | A follow-up inspection revealed that the violations have been resolved. | ||||
-576223882 | 2007-06-20 | A follow-up inspection revealed non-compliance. | ||||
584529606 | 2011-12-15 | Accompanied by Andy Thomas MRI. New identification at wellhead has fallen on the ground. | ||||
-632427697 | 2013-01-10 | Checked injection and annulus pressures at the well. A trench had been dug and new injection line had been laid in it. We are still awaiting an injection line test. Well was not injecting at the time of inspection. Accompanied by Jon Scott. | ||||
6591978 | 2011-12-15 | Accompanied Jon Scott on inspection. | ||||
-688348716 | 2008-03-20 | A follow-up inspection revealed non-compliance. More work needed around the drop tank location. | ||||
705372691 | 2013-06-26 | I conducted a inspection of the lift pump station. This pump lifts brine to flow to their injection well. The fittings on the pump are leaking, the brine is being collected in a pit. The pit is not liquid tight allowing brine to leach thru. I sampled the brine using high range chloride titrators. I sampled two areas both samples registered 2400 PPM chlorides. Mark Smeltzer shut the pump off at 1322 hours. I asked the pump not be used until the leak is corrected and the dike is made liquid tight. The pumping station is located on reed road. | ||||
754870566 | 2004-09-24 | No violations. | ||||
-774978176 | 2015-03-24 | UIC inspection, there is some oil and water in the dike. I called Danny Baker to have the dike pumped out. The injection well has 12 PSI on the injection side, the annulus has 0 pressure. I have contacted Jeanie Enterprises to perform a mini test. | ||||
-780999638 | 2003-12-09 | No violations. | ||||
-818713486 | 2009-06-02 | An inspection of the SWIW and related storage tanks was conducted with Mr. Jeff Fry. During the inspection, an old bare area with exposed flowline were observed below the storage tanks located in a low lying area near the creek. Note: Timber has been removed from this locaton, but signs of stressed vegetation were noted. It was also noted that general housekeeping would be needed at the unloading pad/concrete vault location. Old oil found around the concrete vault and appeared to be breaking down. Old filters along with a drum containing oily debris, which may have leaked would need to be placed inside dike to avoid leakage. At the time of the inspection, the meter showed 224,481 bbls. Left voice mail message for the pumper, Mr. Danny Baker with Jeanie Enterprises on 6/2/2009 at 2:12 pm, in regards to the inspection. Mr. Baker returned call on 6/3/2009 and confirmed line break over the hill last year. Mr. Baker was instructed to place lime, seed and mulch on the impacted area. Perform general housekeeping and recommended filters and drum placed inside dike. | ||||
-822760495 | 2007-10-30 | No violations were noted. | ||||
-83402969 | 2013-07-02 | I accompanied Jon Scott for a line test. The test passed, see Jons report dated 07/02/2013 for results. | ||||
849615643 | 2009-10-01 | An inspection of the saltwater drop or pump station to Roberston (SWIW #1) was conducted. The facility contains only one (1) 100 bbl. The second 100 bbl that contained a hole and was leaking has now been removed. Currently, the existing 100 bbl contains a leak (approx 1 drip every 10 sec) on bottom at valve with swage before connection to PVC elbow fitting. A rag has been placed around the leak. High Range Quantabs exceeded 10 units of Cl-. Note: 8.4 units equals 6545 ppm (mg/L) of Cl-. The attached line is 2 Sch 40 PVC pipe routed to pump house (inlet). A leak was also observed at this location (inlet to pump). 1 drip approx every 60 seconds. The outlet is 2 steel from pump house uphill to SWIW. Old oil observed a pump house with wood chips placed around location. The oil came derives from a rotted steel line that had been repaired. Wash from rainfall events drains from location (pump house and tank) to creek approx 30' and 10' away respectively. The earthen dike around 100bbl tank contains a trench. The pumper, Mr. Danny Baker arrived at location during inspection. He was instructed of deficiencies and made attempt to stop leaks. Mr. Baker states cleanup, dike and water diversion will be done next week. | ||||
855206324 | 2013-09-03 | UIC inspection, the injection well was not in use. The well was being worked on, the filter canister was being repaired. | ||||
-858432577 | 2008-03-13 | A follow-up inspection regarding the leak from a saltwater drop tank (Reed Road) revealed non-compliance. The fluid inside the trench showed 3.8 units on Quantabs (High Range), but was not discharging into the creek. More fluid will need to be pumped from this trench. An elbow fitting, on a steel flow line, that crosses the creek was observed to contain a small leak. Quantab showed maximum of 10 units. The company was contacted and informed of the inspection results. | ||||
-889993238 | 2012-01-25 | I witnessed the injection line test with inspectors Jon Scott and Kip Thompson. The line held 840 pounds of pressure for 15 minutes. | ||||
-902937421 | 2006-09-21 | A follow-up inspection was conducted at the facility owned by Mr. Mark Schmelzer on 9/21/2006. During the inspection, it was noted that the previously noted violations have been resolved. | ||||
-933669370 | 2012-06-20 | Inspected transfer pump facility off of Reed Rd. A new piece of pipe had been installed where the old one had been leaking. No leak detected. | ||||
934148653 | 2008-02-25 | A follow-up inspection revealed that company has been performing cleanup. However, more work will be needed. | ||||
963089080 | 2014-07-30 | Saltwater injection well inspection. The injection pressure was 28 PSI, the annulus pressure was 0 PSI. I have contacted Danny Baker to conduct a mini test to ensure casing integrity. | ||||
-987799875 | 2003-07-24 | No violations | ||||
-994351388 | 2012-01-17 | 1-16-12 Received call from Andy Thomas MRI, that a brine tank had flowed over and into the dike. 1-17-12 made arrangements to meet at tank battery. The tanks had been recently wiped down and the dike had been cleaned out. The spill was contained with in the dike. The injection line from the pump to the injection well has been worked on recently and I requested that they test the line to show mechanical integrity. Two attempts were made to test the injection line. Both attempts were unsuccessful. The pumper requested that they shut down the injection and make repairs to the line on the 1-18-12 then re-test on 1-19-12. | ||||
iTOMK000077 | 2000-08-01 | SWIW#1 | ||||
iTOMK000098 | 2000-11-15 | |||||
UIC60 | 1987-01-05 | 1501:9-3-07(H) | ||||
UIC61 | 1987-01-05 | 1501:9-3-04(A) | ||||
UIC62 | 1987-01-05 | 1501:9-3-05(B)(7) |
For data sources see[2]