{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.55,"lon":-82.45,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Hocking | |
Municipality: Falls Township | |
Operator Name: JEANIE ENTERPRISES LLC | |
Well Pad ID: | |
Farm/Lease Name: ROBERTSON JOSEPHINE W | |
License Status: Active Injection | |
License Date: 1980-07-25 | |
Spud Date: 1979-08-11 | |
Spud Drilling Contractor: BEVERLY DRLG | |
Final Drill Date: 1979-08-16 | |
Well Total Depth: 2608.00 ft | |
Configuration: Vertical | |
Latitude: 39.550000 | |
Longitude: -82.450000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1979-06-05 | 133 QUAKER STATE OIL REF CORP GeoDate 6/5/79 |
Original Spud | 1979-08-11 | CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80 |
Completed | 1979-08-16 | CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80 |
Reached Total Depth | 1979-08-16 | CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80 |
Conversion to Injector | 1980-07-25 | |
First Injection | 1980-11-05 | CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80 |
Annulus Pressure Monitoring Approved | 1986-09-09 | CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80 |
CO | 1991-09-16 | 456 SCHMELZER MARK GeoDate 6/5/79 |
Last Compliance Report | 1999-01-25 | CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80 |
Change of Owner | 2007-08-30 | Operator changed from 456, SCHMELZER MARK to 8268, JEANIE ENTERPISES LLC |
Record Last Modified | 2017-10-19 | CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-04-28 | 2427 | 2456 | 1 |
2427 | 2456 | 1 | |
2427 | 2456 | 1 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1764 Bbl | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1988 | QUAKER STATE OIL REF CORP | 0.00 | 0.00 | 0 |
1991 | QUAKER STATE OIL REF CORP | 0.00 | 0.00 | 365 |
2004 | SCHMELZER MARK | 0.00 | 0.00 | 365 |
2005 | SCHMELZER MARK | 0.00 | 0.00 | 365 |
2006 | SCHMELZER MARK | 0.00 | 0.00 | 365 |
2008 | JEANIE ENTERPRISES LLC | 0.00 | 0.00 | 365 |
2009 | JEANIE ENTERPRISES LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1988 | QUAKER STATE OIL REF CORP | Brine | 380 | 0 |
1991 | QUAKER STATE OIL REF CORP | Brine | 80 | 365 |
2004 | SCHMELZER MARK | Brine | 0 | 365 |
2005 | SCHMELZER MARK | Brine | 0 | 365 |
2006 | SCHMELZER MARK | Brine | 0 | 365 |
2008 | JEANIE ENTERPRISES LLC | Brine | 0 | 365 |
2009 | JEANIE ENTERPRISES LLC | Brine | 180 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1035524058 | 2009-6-16 0:00: | SW | No Violations | |
-1064307432 | 2018-3-26 0:00: | SW | No Violations | 1.20 |
-1151851519 | 2018-8-7 0:00:0 | SW | No Violations | 0.90 |
-1227268402 | 2009-10-7 0:00: | SW | No Violations | |
-1231390251 | 2008-3-7 0:00:0 | SW | No Violations | |
-1250056787 | 2019-11-27 0:00 | SW | No Violations | 6.10 |
-1314429500 | 2009-3-3 0:00:0 | SW | No Violations | |
-1316048722 | 2009-9-2 0:00:0 | SW | No Violations | |
-1369593729 | 2017-5-23 0:00: | SW | No Violations | 3.50 |
-1381422042 | 2011-3-31 0:00: | SW | No Violations | |
-1411064742 | 2012-6-18 0:00: | SW | No Violations | 1.00 |
-1509815397 | 2012-8-20 0:00: | SW | No Violations | 1.50 |
-1517342329 | 2018-8-14 0:00: | SW | No Violations | 3.20 |
-1563744727 | 2017-4-26 0:00: | SW | No Violations | 6.00 |
-1583357363 | 2012-1-16 0:00: | AM | No Violations | 0.50 |
-1588795722 | 2012-12-5 0:00: | SW | No Violations | 1.00 |
-1694141788 | 2003-1-29 0:00: | SW | No Violations | |
-174569852 | 2013-6-27 0:00: | SW | No Violations | 2.00 |
-1776428409 | 2011-8-31 0:00: | SW | No Violations | |
-1786451260 | 2011-3-31 0:00: | SW | No Violations | |
-1796908120 | 2012-6-13 0:00: | SW | No Violations | 1.00 |
-1888650687 | 2005-4-6 0:00:0 | SW | No Violations | |
-1938055957 | 2012-2-23 0:00: | SW | No Violations | |
-1956406417 | 2009-6-10 0:00: | AM | No Violations | |
-1964127281 | 2018-11-8 0:00: | SW | No Violations | 1.50 |
-2080505699 | 2015-4-2 0:00:0 | SW | No Violations | 6.00 |
-2081099343 | 2008-3-14 0:00: | SW | No Violations | |
-2091956777 | 2016-2-3 0:00:0 | SW | No Violations | 2.50 |
-2115776822 | 2013-4-10 0:00: | SW | No Violations | 3.00 |
-259096746 | 2010-12-28 0:00 | SW | No Violations | 0.50 |
-267787825 | 2008-9-8 0:00:0 | SW | No Violations | |
-330363311 | 2005-3-3 0:00:0 | SW | No Violations | |
-33185135 | 2019-11-21 0:00 | SW | No Violations | 3.00 |
-407543686 | 2017-3-28 0:00: | SW | No Violations | 3.50 |
-472394746 | 2005-6-9 0:00:0 | SW | No Violations | |
-519295457 | 2003-6-19 0:00: | SW | No Violations | |
-525601398 | 2012-1-17 0:00: | SW | No Violations | 2.50 |
-565489822 | 2012-6-18 0:00: | SW | No Violations | |
-574483130 | 2008-10-30 0:00 | SW | No Violations | |
-576223882 | 2007-6-20 0:00: | SW | No Violations | |
-632427697 | 2013-1-10 0:00: | SW | No Violations | 1.00 |
-650841418 | 2015-6-18 0:00: | SW | No Violations | 1.50 |
-682616630 | 2020-5-14 0:00: | SW | No Violations | 3.50 |
-688348716 | 2008-3-20 0:00: | SW | No Violations | |
-774978176 | 2015-3-24 0:00: | SW | No Violations | 1.00 |
-780999638 | 2003-12-9 0:00: | SW | No Violations | |
-818713486 | 2009-6-2 0:00:0 | SW | No Violations | |
-822760495 | 2007-10-30 0:00 | SW | No Violations | |
-83402969 | 2013-7-2 0:00:0 | SW | No Violations | 4.00 |
-858432577 | 2008-3-13 0:00: | SW | No Violations | |
-885834854 | 2020-3-19 0:00: | SW | No Violations | 2.00 |
-889993238 | 2012-1-25 0:00: | SW | No Violations | 1.00 |
-902937421 | 2006-9-21 0:00: | SW | No Violations | |
-933669370 | 2012-6-20 0:00: | SW | No Violations | 1.00 |
-966382051 | 2017-4-19 0:00: | SW | No Violations | |
-987799875 | 2003-7-24 0:00: | SW | No Violations | |
-994351388 | 2012-1-17 0:00: | SW | No Violations | |
00000UIC60 | 1987-01-05 | Salt Water Injection Well | No Violations | 1501:9-3-07(H) |
00000UIC61 | 1987-01-05 | Salt Water Injection Well | No Violations | 1501:9-3-04(A) |
00000UIC62 | 1987-01-05 | Salt Water Injection Well | No Violations | 1501:9-3-05(B)(7) |
0006591978 | 2011-12-15 | Salt Water Injection Well | No Violations | Accompanied Jon Scott on inspection. |
001269i210 | 2000-12-18 | Production Wells | No Violations | FOLLOW - UP ON NOV , IN - COMPLIANCE . |
001269i513 | 2001-11-13 | Salt Water Injection Well | No Violations | No violations. |
001269i698 | 2002-01-16 | Salt Water Injection Well | No Violations | No violations. |
0026429069 | 2019-01-15 | Salt Water Injection Well | No Violations | Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification posted. Annulus was frozen. |
005609i211 | 2001-06-04 | Salt Water Injection Well | No Violations | |
0083402969 | 2013-07-02 | Salt Water Injection Well | No Violations | I accompanied Jon Scott for a line test. The test passed, see Jons report dated 07/02/2013 for results. |
01269i1074 | 2002-05-22 | Salt Water Injection Well | No Violations | Follow-up on NOV, In-Compliance. Unable to check pressures on well , do not have tools to remove plugs in valves. |
01269i1398 | 2002-09-24 | Salt Water Injection Well | No Violations | No violations at this time. |
0136248629 | 2013-06-28 | Salt Water Injection Well | No Violations | The dike is being rebuilt today, the plumbing where the leak was is also being repaired. |
0161051084 | 2004-12-14 | Salt Water Injection Well | No Violations | No violations. |
0171417511 | 2016-05-03 | Salt Water Injection Well | No Violations | Inspected the containment area, tanks, injection pressure and annulus pressure. Accompanied by the UIC Supervisor. |
0174569852 | 2013-06-27 | Salt Water Injection Well | No Violations | Danny Baker has pumped out the dike. The dike was then removed to allow for the placement of a dike that will be liquid tight. They are plumbing the pump to eliminate the brine leak. |
0236826559 | 2008-03-06 | Salt Water Injection Well | Violations Noted | An inspection revealed that one of the two 100 bbl saltwater drop tanks (located on Reed Road) was corroded and leaking at the bottom. A large trench located at a lower elevation serves as a catch basin. Fluid inside this trench was observed draining into a nearby creek. Quantabs (high range) showed 10 units near the source of the leak and location where the fluid drains into the creek. A new 100 bbl tank was observed at the entrance to the lease road. Contacted the owner, Jeanie Schmeltzer and pumper for the company. They were informed to resolve this issue immediately. The company states that they will have a water truck pump the trench today. And the fluid inside the leaking tank will be transferred over to the injection well. The pumper states that they found this leak on the 3/5/2008. A new 100 bbl tank was observed on-site. Dennis Deavers with OEPA was informed of the inspection results. |
0259096746 | 2010-12-28 | Salt Water Injection Well | No Violations | An inspection revealed no violations. The meter showed no change as 224481 bbls were observed. Snow cover at time of inspection. |
0267787825 | 2008-09-08 | Salt Water Injection Well | Violations Noted | An inspection revealed no identification at the storage tanks. The identification card placed at the well was found to contain only the previous companies name. No additional information was observed. Identification was not observed at the storage tanks. Contamination and pollution was observed at the unloading pad. The company was contacted by telephone and informed of the inspection results. |
0291345184 | 2013-04-10 | Surface Facility Construction | No Violations | Injection line test. Attempted to test injection line two times. A leak was found on a 2 union. The leak was not able to be repaired during the inspection. The line test will be rescheduled after repairs are made. No injection until the line is tested and passed. Inspector Kip Thompson accompanied me on the test. |
0330363311 | 2005-03-03 | Salt Water Injection Well | No Violations | No violations. |
0379760063 | 2013-07-11 | Salt Water Injection Well | No Violations | Danny Baker has rebuilt the dike and repaired the plumbing on the pump. The leaks have been fixed and the dike has been rebuilt with clay from Logan clay. This satisfies the compliance notice. |
0384859649 | 2015-09-17 | Salt Water Injection Well | No Violations | Witnessed a mini test on the annulus. Tested at 410 psi for 15 minutes with a loss of 5 psi. A small leak was observed on a 1/4 ball valve on the annulus during the test. Danny Baker said they will replace the valve. |
0407543686 | 2017-03-28 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted on the tank and well site. The containment dike is free of fluids. |
0441784917 | 2017-05-25 | Salt Water Injection Well | Violations Noted | Salt water injection well inspection. The well had 23 psi on the injection tubing and 0 psi on the annulus. The well will need a mechanical integrity test to determine if the well has mechanical integrity. |
0472394746 | 2005-06-09 | Salt Water Injection Well | No Violations | No violations |
0479843378 | 2008-02-11 | Salt Water Injection Well | Violations Noted | An inspection revealed that a 210 bbl storage tank has overflowed onto the ground surface. The impacted areas ranged from 1-2 ft sections outside the concrete dike placed around the storage tanks,and a 10x20ft section around the unloading pad. An earthen impoundment was also found to be impacted. A 5x3 ft section of oil was observed. This source of water containment does not lead to a creek or stream. Equipment (mini excavator) and cleanup supplies were observed on-site. Also noted was that new identification would be needed at the well head. The company, Jeanie Enterprises, and the pumper, Mr. Danny Baker, were both contacted and informed of inspection results. Mr. Baker states that they have been working on cleanup and have taken oily soils to the landfill and will provide run tickets. He was informed that the impoundment will also need to be addressed along with the areas outside the dike. |
0488943911 | 2013-01-10 | Salt Water Injection Well | No Violations | Inspected salt water injection well injection tubing pressure and annulus pressure. Good identification at well head. Steel injection line has been installed in an open ditch. Currently waiting on company to test the injection line from the tank battery to the well. Injection operations are shut down waiting on the line test and the replacement of the brine pump. Accompanied by Andy Thomas MRI 2. |
0519295457 | 2003-06-19 | Salt Water Injection Well | No Violations | No violations. |
0525601398 | 2012-01-17 | Salt Water Injection Well | No Violations | When I arrived at the tank battery, the injection pump was running. I immediately called Danny Baker and told him that an injection line test needed to be administered, and witnessed by the state before he could run the pump. This test was supposed to have taken place in the summer of 2011. I was then joined by Jon Scott south region UIC inspector. When Danny Baker arrived with his crew, two attempts were made to test the flow line. Both had failed. Inspector Kip Thompson was also present on this inspection. |
0543640086 | 2012-06-13 | Salt Water Injection Well | Violations Noted | Concrete containment at the tank battery was full of fluid. The vault was also full and had appeared to had flown over. Mr. Danny Baker was called immediately. He stated that he would be out promptly to take care of the situation. He also stated that the problem was due to a tank overflow. We agreed that absobant material would be used to soak fluid up and then material would be shoveled out an hauled to an approved landfill. I checked back later on the same day and the vault had been pumped out. |
0565489822 | 2012-06-18 | Salt Water Injection Well | No Violations | Follow up with Andy Thomas MRI 2 at dike. Oil spill in dike has been cleaned up. Dike is free of oil. No oil on the ground near the concrete vault. Brine contaminated soil has not been removed. |
0574483130 | 2008-10-30 | Salt Water Injection Well | No Violations | A follow-up inspection revealed that the violations have been resolved. |
0576223882 | 2007-06-20 | Salt Water Injection Well | No Violations | A follow-up inspection revealed non-compliance. |
0584529606 | 2011-12-15 | Salt Water Injection Well | No Violations | Accompanied by Andy Thomas MRI. New identification at wellhead has fallen on the ground. |
0632427697 | 2013-01-10 | Salt Water Injection Well | No Violations | Checked injection and annulus pressures at the well. A trench had been dug and new injection line had been laid in it. We are still awaiting an injection line test. Well was not injecting at the time of inspection. Accompanied by Jon Scott. |
0650841418 | 2015-06-18 | Salt Water Injection Well | Violations Noted | Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification was not legible on the tanks and was not seen at the well site. Post identification at the surface facility and the well. The annulus pressure was on vacuum. Must maintain a positive pressure on the annulus. A mini test needs to be scheduled with the inspector. A call was placed to the company regarding the violations on 6-18-15. |
0688348716 | 2008-03-20 | Salt Water Injection Well | No Violations | A follow-up inspection revealed non-compliance. More work needed around the drop tank location. |
0705372691 | 2013-06-26 | Salt Water Injection Well | Violations Noted | I conducted a inspection of the lift pump station. This pump lifts brine to flow to their injection well. The fittings on the pump are leaking, the brine is being collected in a pit. The pit is not liquid tight allowing brine to leach thru. I sampled the brine using high range chloride titrators. I sampled two areas both samples registered 2400 PPM chlorides. Mark Smeltzer shut the pump off at 1322 hours. I asked the pump not be used until the leak is corrected and the dike is made liquid tight. The pumping station is located on reed road. |
0729392706 | 2018-05-15 | Salt Water Injection Well | No Violations | Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. |
0748798232 | 2015-09-23 | Surface Facility Construction | No Violations | Surface facility inspection with UIC section Geologist. |
0754870566 | 2004-09-24 | Salt Water Injection Well | No Violations | No violations. |
0774978176 | 2015-03-24 | Salt Water Injection Well | No Violations | UIC inspection, there is some oil and water in the dike. I called Danny Baker to have the dike pumped out. The injection well has 12 PSI on the injection side, the annulus has 0 pressure. I have contacted Jeanie Enterprises to perform a mini test. |
0780999638 | 2003-12-09 | Salt Water Injection Well | No Violations | No violations. |
0794724910 | 2017-04-18 | Salt Water Injection Well | No Violations | Compliance notice follow-up. Danny Baker with Baker Enterprises is removing the brine contaminated soil. The soil was removed and I sampled the remaining soil to determine if contained any chlorides. I tested the soil using quantabs to determine the quantity of the chlorides. The soil that was removed was stocked piled on site and a dike was placed around the soil. This soil will be taken to a landfill on 4-19-17. |
0818713486 | 2009-06-02 | Salt Water Injection Well | Violations Noted | An inspection of the SWIW and related storage tanks was conducted with Mr. Jeff Fry. During the inspection, an old bare area with exposed flowline were observed below the storage tanks located in a low lying area near the creek. Note: Timber has been removed from this locaton, but signs of stressed vegetation were noted. It was also noted that general housekeeping would be needed at the unloading pad/concrete vault location. Old oil found around the concrete vault and appeared to be breaking down. Old filters along with a drum containing oily debris, which may have leaked would need to be placed inside dike to avoid leakage. At the time of the inspection, the meter showed 224,481 bbls. Left voice mail message for the pumper, Mr. Danny Baker with Jeanie Enterprises on 6/2/2009 at 2:12 pm, in regards to the inspection. Mr. Baker returned call on 6/3/2009 and confirmed line break over the hill last year. Mr. Baker was instructed to place lime, seed and mulch on the impacted area. Perform general housekeeping and recommended filters and drum placed inside dike. |
0822760495 | 2007-10-30 | Salt Water Injection Well | No Violations | No violations were noted. |
0849615643 | 2009-10-01 | Salt Water Injection Well | Violations Noted | An inspection of the saltwater drop or pump station to Roberston (SWIW #1) was conducted. The facility contains only one (1) 100 bbl. The second 100 bbl that contained a hole and was leaking has now been removed. Currently, the existing 100 bbl contains a leak (approx 1 drip every 10 sec) on bottom at valve with swage before connection to PVC elbow fitting. A rag has been placed around the leak. High Range Quantabs exceeded 10 units of Cl-. Note: 8.4 units equals 6545 ppm (mg/L) of Cl-. The attached line is 2 Sch 40 PVC pipe routed to pump house (inlet). A leak was also observed at this location (inlet to pump). 1 drip approx every 60 seconds. The outlet is 2 steel from pump house uphill to SWIW. Old oil observed a pump house with wood chips placed around location. The oil came derives from a rotted steel line that had been repaired. Wash from rainfall events drains from location (pump house and tank) to creek approx 30 and 10 away respectively. The earthen dike around 100bbl tank contains a trench. The pumper, Mr. Danny Baker arrived at location during inspection. He was instructed of deficiencies and made attempt to stop leaks. Mr. Baker states cleanup, dike and water diversion will be done next week. |
0855206324 | 2013-09-03 | Salt Water Injection Well | No Violations | UIC inspection, the injection well was not in use. The well was being worked on, the filter canister was being repaired. |
0858432577 | 2008-03-13 | Salt Water Injection Well | No Violations | A follow-up inspection regarding the leak from a saltwater drop tank (Reed Road) revealed non-compliance. The fluid inside the trench showed 3.8 units on Quantabs (High Range), but was not discharging into the creek. More fluid will need to be pumped from this trench. An elbow fitting, on a steel flow line, that crosses the creek was observed to contain a small leak. Quantab showed maximum of 10 units. The company was contacted and informed of the inspection results. |
0889993238 | 2012-01-25 | Salt Water Injection Well | No Violations | I witnessed the injection line test with inspectors Jon Scott and Kip Thompson. The line held 840 pounds of pressure for 15 minutes. |
0891579285 | 2017-04-20 | Salt Water Injection Well | No Violations | Danny Baker with Baker Oil Field Services has emptied the 100 barrel tank and moved the tank to allow removal of the brine contaminated soil that was under the tank. The dike will be rebuilt using a liner. |
0902937421 | 2006-09-21 | Salt Water Injection Well | No Violations | A follow-up inspection was conducted at the facility owned by Mr. Mark Schmelzer on 9/21/2006. During the inspection, it was noted that the previously noted violations have been resolved. |
0933669370 | 2012-06-20 | Salt Water Injection Well | No Violations | Inspected transfer pump facility off of Reed Rd. A new piece of pipe had been installed where the old one had been leaking. No leak detected. |
0934148653 | 2008-02-25 | Salt Water Injection Well | No Violations | A follow-up inspection revealed that company has been performing cleanup. However, more work will be needed. |
0963089080 | 2014-07-30 | Salt Water Injection Well | No Violations | Saltwater injection well inspection. The injection pressure was 28 PSI, the annulus pressure was 0 PSI. I have contacted Danny Baker to conduct a mini test to ensure casing integrity. |
0966382051 | 2017-04-19 | Salt Water Injection Well | No Violations | Danny Baker with Baker Oil Field Services is removing brine contaminated soil from the below the dike and the soil inside the dike. The tank will be moved to allow removal of soil under the tank. The steel production lines are being replaced and a new Murphy switch is being installed. The contaminated soil will be disposed of at Kilbargers landfill. I used low range and high range quantabs to determine the amount of soil that needed to be removed. |
0987799875 | 2003-07-24 | Salt Water Injection Well | No Violations | No violations |
0994351388 | 2012-01-17 | Salt Water Injection Well | No Violations | 1-16-12 Received call from Andy Thomas MRI, that a brine tank had flowed over and into the dike. 1-17-12 made arrangements to meet at tank battery. The tanks had been recently wiped down and the dike had been cleaned out. The spill was contained with in the dike. The injection line from the pump to the injection well has been worked on recently and I requested that they test the line to show mechanical integrity. Two attempts were made to test the injection line. Both attempts were unsuccessful. The pumper requested that they shut down the injection and make repairs to the line on the 1-18-12 then re-test on 1-19-12. |
1035524058 | 2009-06-16 | Salt Water Injection Well | No Violations | An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50 x 50 area. Note: Company employee states that line broke in Fall 2008. |
1046961243 | 2003-03-04 | Salt Water Injection Well | No Violations | Follow-up on NOV, Non-Compliance, company has not rewrote ID or hung electric line. |
1052748940 | 2003-05-06 | Salt Water Injection Well | No Violations | Follow-up on NOV, In-Compliance. |
1064307432 | 2018-03-26 | Salt Water Injection Well | No Violations | The salt water injection well had 0 psi on the injection tubing, The annulus was on vacuum. I have contacted Jeanie Enterprises to have mechanical integrity test performed to prove the there is no communication between the tubing and the annulus. I called Mr. Mark Schmeltzer at 0923 hours. I was unable to leave a message. I then called Mr. Danny Baker at 0935 hours and told Mr. Baker that a mechanical integrity test would be required to prove there was no communication. |
1075413650 | 2004-01-27 | Salt Water Injection Well | No Violations | No violations. |
1078149911 | 2004-02-26 | Salt Water Injection Well | No Violations | No violations. |
1092938833 | 2004-08-19 | Salt Water Injection Well | Violations Noted | An inspection of the well revealed ID needs rewrote at well and tank battery, oily soil around storage tanks needs cleaned up. NEW LAT & LONG |
1096616651 | 2018-01-24 | Salt Water Injection Well | Violations Noted | The salt water injection wells annulus was on vacuum and the injection tubing was also on vacuum. I have issued a compliance notice to have the well tested to ensure that there is no communication between the annulus and the injection tubing. I called Jeanie Enterprises and informed them of the violation and they agreed to perform a MIT test as soon as possible. |
1129194392 | 2017-05-31 | Salt Water Injection Well | No Violations | Compliance notice follow-up. The well was pressure tested today at 471 PSI for 15 minutes with no loss. The well passed the mechanical integrity test. |
1131146540 | 2016-11-14 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The 1/4 inch annulus valve handle was slightly open. The annulus had zero pressure. |
1151851519 | 2018-08-07 | Salt Water Injection Well | No Violations | Inspected the containment area, tanks, injection pressure and annulus pressure. Identification is posted at the well and facility. |
1154697983 | 2006-07-25 | Salt Water Injection Well | Violations Noted | An inspection was conducted at the facility owned by Mr. Mark Schmelzer on 7/25/2006. During the inspection, it was noted that the injection line had a small pinhole leak in the injection line. As a result, brine was being discharged directly onto the ground surface. Also noted was that the surrounding area contained dead vegetation. Mrs. Gene Schmelzer was immediately contacted by telephone @11:15am on 7/25/2006. She was informed to correct this problem immediately. In regards to the SWIW inspection, it was found that a ID will be needed at the well. The ID the storage tanks contains the wrong area code. The dike needs to be pumped and the oily soil and material needs to be removed from the lease. On 7/28/2006, a follow-up inspection was conducted to ensure that the leaking fitting has been replaced. During the inspection, it was noted that the fitting was replaced and straw had been applied to the surrounding area. |
1154992731 | 2006-07-28 | Salt Water Injection Well | No Violations | During the insspection conducted on 7/28/2006, it was noted that the leaking injection fitting was replaced. Straw was applied to the surrounding area. |
1168620032 | 2007-01-10 | Salt Water Injection Well | No Violations | No violations were noted during the inspection. |
1173076558 | 2009-07-07 | Surface Facility Construction | No Violations | A follow-up inspection revealed compliance. |
1206865706 | 2016-03-21 | Salt Water Injection Well | No Violations | Inspected the containment area, tanks, injection pump, injection pressure, and annulus pressure. Identification posted on the tank. Containment is free of fluids. |
1207012412 | 2008-03-31 | Salt Water Injection Well | No Violations | A follow-up inspection conducted on saltwater drop tanks revealed that the trench has been filled, area graded and 100 bbl tanks removed. The elbow fitting that contained a small leak has been repaired. The company is removing abandoned steel flow lines and re-routing a section of the active flow line to the SWIW. Seed and mulch will be applied to the area. Contamination and pollution has been taken to the landfill. The wells tied into the drop tanks (saltwater) have been shut-down, until new tanks are installed and a dike has been constructed. |
1211473626 | 2008-05-21 | Salt Water Injection Well | No Violations | No violations |
1221052423 | 2007-04-24 | Salt Water Injection Well | Violations Noted | An inspection revealed that a new 1/4 inch valve is needed on the injection side of the well. |
1227268402 | 2009-10-07 | Salt Water Injection Well | No Violations | A follow-up inspection revealed non-compliance. |
1231390251 | 2008-03-07 | Salt Water Injection Well | No Violations | A follow-up inspection was conducted at the Robertson SWIW. More cleanup will be needed inside the earthen impoundment located near the storage tanks. |
1237234076 | 2017-10-19 | Salt Water Injection Well | Violations Noted | My inspection revealed the injection facility has a oil stain next to the brine vault. The stain is approximately 2 feet by 2 feet. I contacted Mr. Danny Baker to have the oil stain removed. |
1257863060 | 2009-11-10 | Salt Water Injection Well | No Violations | A follow-up inspection revealed compliance. The earthen dike has been addressed, leaks stopped and location graded. |
1259912222 | 2010-06-24 | Salt Water Injection Well | No Violations | An inspection revealed no violations. |
1268765138 | 2010-03-16 | Salt Water Injection Well | No Violations | An inspection revealed no violations at this time. The bbl counter at storage tank(s) location showed 224481. |
1269i1074 | 2002-5-22 0:00: | SW | No Violations | |
1269i11751 | 2001-03-27 | Salt Water Injection Well | No Violations | No violations |
1269i11751146 | 2001-3-27 0:00: | SW | No Violations | |
1269i1398 | 2002-9-24 0:00: | SW | No Violations | |
1269i210 | 2000-12-18 0:00 | PW | No Violations | |
1269i513 | 2001-11-13 0:00 | SW | No Violations | |
1269i698 | 2002-1-16 0:00: | SW | No Violations | |
1269i87457 | 2002-03-19 | Salt Water Injection Well | No Violations | An inspection of the well revealed that the pump is leaking brine, the pump needs repaired or replaced. |
1269i87457142 | 2002-3-19 0:00: | SW | No Violations | |
1285691603 | 2010-09-27 | Salt Water Injection Well | No Violations | An inspection revealed no violations. The barrel counter at storage tank location showed 224,481. Note: The gauge utilized for this inspection will require calibration. |
1314429500 | 2009-03-03 | Salt Water Injection Well | No Violations | An inspection revealed no violations at this time. |
1316048722 | 2009-09-02 | Salt Water Injection Well | No Violations | An inspection revealed that general housekeeping has been performed at the tank battery location. The meter at the tank battery location showed 224481 bbl. Vegetative growth also observed, in patches, at the line break location. |
1334681705 | 2012-04-16 | Salt Water Injection Well | Violations Noted | Conducted an inspection on transfer pump facility off of Reed Rd. North of Logan. GPS coordinates N 39.56988, W 82.43575. Due to lack of vegetation, it was suspected that there had been a brine spill. Quantab results from a puddle of water in the vegetation kill area showed that the chloride content was too high for the Quantab to quantify. Mr. Danny Baker was notified by a phone call, and instructed to remediate soil where the vegetation was killed and build a containment dike around the pump because Mr. Baker had suspected it was leaking. He was also advised of other potential plumbing risks associated with the pump. Mr. Baker stated that he would be out there the following day with a piece of equipment to remediate situation. |
1346582948 | 2008-03-06 | Salt Water Injection Well | No Violations | Witnessed a water truck pump out the trench containing brine. The company is transferring brine from the leaking tank to the Robertson SWIW. More fluid will need to be pumped out of the trench and tank will need to repaired or replaced. |
1354714952 | 2012-12-04 | Salt Water Injection Well | No Violations | The purpose of the inspection was to witness and injection line test. The company was not ready to perform the test when I arrived. They had detected a leak and were looking for it. Accompanied by Andrew Adgate and Steve riley. |
1358743542 | 2009-12-03 | Salt Water Injection Well | No Violations | An inspection revealed no violations at this time. The meter at the tank battery location showed 224481 bbl. |
136248629 | 2013-6-28 0:00: | SW | No Violations | 3.00 |
1369593729 | 2017-05-23 | Salt Water Injection Well | No Violations | Danny Baker has continued to remove brine contaminated soil. 33 tons of soil has been taken to a approved landfill for disposal. I checked the soil and found approximately 980 PPM chlorides remain. The soil will be removed until the chloride content is at or below 250 PPM. |
1372851473 | 2013-07-02 | Salt Water Injection Well | No Violations | Injection line pressure test. Tested steel line from surface facility to the well at 795 psi for 15 minutes with no loss in pressure. Inspector Kip Thompson witnessed Danny Baker open the master valve on the well head after the test. The gauge at the surface facility dropped from 795 psi to 20 psi when the master valve was opened. |
1378604987 | 2008-02-26 | Salt Water Injection Well | No Violations | A follow-up inspection revealed non-compliance. |
1381422042 | 2011-03-31 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # -1786451260 Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break. |
1403721816 | 2004-04-01 | Salt Water Injection Well | No Violations | No violations. |
1407509652 | 2014-08-08 | Salt Water Injection Well | No Violations | UIC inspection, I requested a MIT test to ensure their was no communication between the injection zone and the annulus. The test was held for 15 minutes for 305 PSI with no loss. |
1411064742 | 2012-06-18 | Salt Water Injection Well | No Violations | Accompanied by inspector Jon Scott. Observed what clean up had been performed. Bags filled with contaminated soil were still loaded on a roll back truck. Clean up had also been performed around vault where it had overflowed. |
1413903286 | 2014-10-21 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The containment vault lid was off. The fluid level in the vault was low. A new sump pump appears to have been installed. New identification was posted at the well. |
1422457871 | 2015-01-28 | Salt Water Injection Well | No Violations | UIC inspection, the injection pressure was 11 PSI. The annulus pressure was 2 PSI. |
1435168223 | 2015-06-24 | Salt Water Injection Well | No Violations | Compliance notice follow up. Mechanical Integrity Test. Tested annulus at 760 psi. At 15 minutes test pressure was 740 psi. Test passed. Identification is posted. Inspected the injection pressure. |
1442344801 | 2015-09-14 | Salt Water Injection Well | Violations Noted | Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification on tanks did not have API number. Identification at well was complete. Annulus was on vacuum and injection tubing was at zero pressure. I called Danny Baker and told him that they will need to test the annulus and that they need to post a complete identification at the facility. |
1454207791 | 2009-10-14 | Salt Water Injection Well | No Violations | A follow-up inspection revealed that the leaks have been addressed. Work has been done on earthen dike, but not completed. The location will also be graded. |
1455912811 | 2016-02-18 | Salt Water Injection Well | No Violations | Injection line test. Injection line was pressure tested at 1040 psi for 15 minutes with no loss. Witnessed the test and the release of pressure after opening the injection tubing master valve. Test passed. |
1472491286 | 2016-08-29 | Salt Water Injection Well | No Violations | Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification posted on the tank. |
1492182530 | 2017-04-14 | Salt Water Injection Well | Violations Noted | My inspection revealed a area of ground below the dike that was covered with straw. The 100 barrel tank that holds salt water had run over and spilled salt water down hill. The spill is approximately 22 feet by 31 feet. I used high range and low range quantabs to check for salinity. I used 3 quantabs and found a average reading of 2200 PPM. I met Danny Baker on site and he agreed to clean up the soil that was contaminated with brine. I called Emergency Response and reported the spill. |
1509815397 | 2012-08-20 | Salt Water Injection Well | No Violations | Well and tank battery are in compliance. |
1511436599 | 2014-01-09 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection line, Injection pressure, and annulus pressure. Identification posted on tank with-in the containment dike. Activity around the surface facility includes removal of a portion of fencing near the road, removal of debris and brush from inside remaining fenced area. New rolls of plastic pipe are on location. |
1517342329 | 2018-08-14 | Salt Water Injection Well | No Violations | Surface facility inspection with ODNR DOGRM UIC Geologist. |
1519320400 | 2018-02-22 | Salt Water Injection Well | No Violations | My inspection revealed the pollution and contamination has been removed. This satisfies the compliance notice. |
1554414865 | 2014-03-11 | Salt Water Injection Well | No Violations | UIC inspection. I checked the injection well, the injection pressure was 0. The annulus pressure was 0. I contacted Danny Baker to conduct a 300 PSI mini test to ensure the annulus would hold pressure. |
1563744727 | 2017-04-26 | Salt Water Injection Well | No Violations | Mr. Danny Baker on site removing contaminated soil from the dike. The 100 barrel tank has been removed to allow removal of contaminated soil that is below the tank. Approximately 2.5 feet of soil has been removed and taken to the landfill. I have tested the soil at this level and found chloride content to be approximately 1600 PPM. I told Mr. Baker soil would need removed until the chloride content was below 250 PPM. |
1583357363 | 2012-01-16 | Administrative Inspection | No Violations | I received a phone call from Walter Borne at 10:25 am. He stated that the tank battery for this well was overflowing. I then placed a phone call to Danny Baker who is an employee of Jeanie Enterprises and told him what was going on. He said that he would go straight there and take care of it. |
1588795722 | 2012-12-05 | Salt Water Injection Well | No Violations | There was nobody on site when I arrived. Called Danny Baker and he was on his way. One section of pipe still needed replaced on the injection line. |
1589454858 | 2020-5-13 0:00: | SW | No Violations | 3.50 |
1594209925 | 2020-7-6 0:00:0 | SW | No Violations | 3.50 |
161051084 | 2004-12-14 0:00 | SW | No Violations | |
1642470419 | 2004-05-27 | Salt Water Injection Well | No Violations | No violations |
1665678183 | 2012-01-25 | Salt Water Injection Well | No Violations | Test 2 steel injection line from the pump (in tank dike) to the salt water injection well. Tested at 850 pounds per square inch for 15 minutes with no loss. Opened master valve on injection tubing and witnessed pressure drop. Test passed. |
1694141788 | 2003-01-29 | Salt Water Injection Well | Violations Noted | An inspection of the well revealed the ID needs REWOTE at the well and tanks, an electric line running along tank battery needs HUNG back up. |
171417511 | 2016-5-3 0:00:0 | SW | No Violations | 3.50 |
1776428409 | 2011-08-31 | Salt Water Injection Well | No Violations | Faded Identification at well. |
1786451260 | 2011-03-31 | Salt Water Injection Well | Violations Noted | Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break. |
1796908120 | 2012-06-13 | Salt Water Injection Well | No Violations | I conducted an inspection on the transfer pump facility on Reed Rd with Jon Scott Inspector 3 South region. We found that there was a flow line leak at the pump at an elbow. It dripped once every 30 seconds. Mr. Danny Baker was notified of this immediately. He stated that he would be out to fix it promptly. |
1805235116 | 2018-03-20 | Salt Water Injection Well | No Violations | The salt water injection well had 0 psi on the injection tubing and 4 psi on the annulus. The dike was reasonably free of fluids. Legible identification was posted. |
1880257932 | 2007-08-13 | Salt Water Injection Well | No Violations | A follow-up inspection revealed that the well is in-compliance. |
1888650687 | 2005-04-06 | Salt Water Injection Well | No Violations | No violations. |
1930017565 | 2020-6-30 0:00: | SW | No Violations | 6.60 |
1938055957 | 2012-02-23 | Salt Water Injection Well | No Violations | Injection pump operating during inspection. |
1939052819 | 2012-06-14 | Salt Water Injection Well | No Violations | Checked on clean-up efforts performed by Mr. Danny Baker and company. Fluid had been absorbed and material bagged up and placed on a roll back truck. |
1941229516 | 2014-03-13 | Salt Water Injection Well | No Violations | Compliance notice follow-up. The pit has been rebuilt and the leaking pump has been rebuilt. This satisfies the compliance notice. |
1956406417 | 2009-06-10 | Administrative Inspection | No Violations | The pumper for Jeanie Enterprises called at 3:20 PM and stated that 10 lb with lime, seed and mulch applied to line break location. |
1964127281 | 2018-11-08 | Salt Water Injection Well | No Violations | On Site with UIC Supervisor. Inspected the containment area, tanks, injection pump, vault, injection pressure and annulus pressure. Identification is posted. Containment area is free of fluids. The vault is full of fluid. I called Danny Baker and told him the vault was full. Danny told me that he will pump it into the tank for disposal. We also discussed the need to keep positive pressure on the annulus. Danny told me that he will schedule a test soon. |
2013704891 | 2012-04-17 | Salt Water Injection Well | No Violations | Witnessed remedial work performed by Mr. Danny Baker on the transfer pump facility off of Reed Rd., Logan. |
2032038049 | 2008-03-26 | Salt Water Injection Well | No Violations | A follow-up inspection revealed that the cleanup has been performed around the storage tank location. The company will be providing a run ticket for contaminated soil. The previously noted violations have been resolved. |
2080505699 | 2015-04-02 | Salt Water Injection Well | No Violations | UIC inspection. Baker Oilfield Services on site to perform a mini test. The test was held at 310 PSI for 15 minutes. Their was no loss in pressure for the duration of the test. |
2081099343 | 2008-03-14 | Salt Water Injection Well | No Violations | A follow-up inspection revealed non-compliance. C&P still observed at the storage tanks. |
2082007621 | 2008-03-21 | Salt Water Injection Well | No Violations | A follow-up inspection revealed that cleanup has been performed around the unloading pad. It was noted that more work will be required around the earthen impoundment . |
2091956777 | 2016-02-03 | Salt Water Injection Well | No Violations | Inspected the containment area, tanks, injection pump, injection line, injection pressure and annulus pressure. A section of the injection line has been recently replaced. I called Danny Baker and asked about this replacement. Danny told me that the line was replaced as an upgrade to the facility. I told Danny that the line must be tested. A test is scheduled for the week of 2-8-16. |
2100817012 | 2012-11-27 | Salt Water Injection Well | No Violations | There was a small amount of contamination inside the containment dike, and some general housekeeping needs performed on site. Left a message on Mr. Danny Bakers phone to make him aware of this. Everything else is in compliance. Spoke with Mr. Baker later on on Wednesday 11/28/12 at 8:47 am and he agreed to cleaning the site up. He stated that he had plans to do so anyway. |
2103857190 | 2017-12-19 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well is in compliance. The brine spill has been cleaned. This satisfies the compliance notice. |
2115776822 | 2013-04-10 | Salt Water Injection Well | No Violations | UIC training with Jon Scott, see Jon Scotts report for details. |
2125323217 | 2019-5-14 0:00: | SW | No Violations | 4.50 |
2145792277 | 2003-10-27 | Salt Water Injection Well | No Violations | No violations |
236826559 | 2008-3-6 0:00:0 | SW | No Violations | |
26429069 | 2019-1-15 0:00: | SW | No Violations | 2.00 |
291345184 | 2013-4-10 0:00: | SC | No Violations | 4.00 |
379760063 | 2013-7-11 0:00: | SW | No Violations | 1.00 |
384859649 | 2015-9-17 0:00: | SW | No Violations | 3.00 |
441784917 | 2017-5-25 0:00: | SW | No Violations | |
454710540 | 2020-6-29 0:00: | SC | No Violations | 0.50 |
479843378 | 2008-2-11 0:00: | SW | No Violations | |
488943911 | 2013-1-10 0:00: | SW | No Violations | 1.00 |
543640086 | 2012-6-13 0:00: | SW | No Violations | 2.00 |
5609i211 | 2001-6-4 0:00:0 | SW | No Violations | |
584529606 | 2011-12-15 0:00 | SW | No Violations | |
6591978 | 2011-12-15 0:00 | SW | No Violations | 1.50 |
667774724 | 2019-7-10 0:00: | SW | No Violations | 1.20 |
705372691 | 2013-6-26 0:00: | SW | No Violations | 4.00 |
729392706 | 2018-5-15 0:00: | SW | No Violations | 0.70 |
748798232 | 2015-9-23 0:00: | SC | No Violations | 2.00 |
754870566 | 2004-9-24 0:00: | SW | No Violations | |
794724910 | 2017-4-18 0:00: | SW | No Violations | 4.00 |
849615643 | 2009-10-1 0:00: | SW | No Violations | |
855206324 | 2013-9-3 0:00:0 | SW | No Violations | 2.00 |
891579285 | 2017-4-20 0:00: | SW | No Violations | 2.00 |
934148653 | 2008-2-25 0:00: | SW | No Violations | |
963089080 | 2014-7-30 0:00: | SW | No Violations | 2.00 |
iTOMK00007 | 2000-08-01 | Salt Water Injection Well | No Violations | SWIW#1 |
iTOMK000077 | 2000-8-1 0:00:0 | SW | No Violations | |
iTOMK00009 | 2000-11-15 | Salt Water Injection Well | Violations Noted | |
iTOMK000098 | 2000-11-15 0:00 | SW | No Violations | |
UIC60 | 1987-1-5 0:00:0 | SW | No Violations | |
UIC61 | 1987-1-5 0:00:0 | SW | No Violations | |
UIC62 | 1987-1-5 0:00:0 | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0236826559 | US-OH-122366 | 2008-03-26 | Pollution/Contamination | |
0236826559 | US-OH-122367 | 2008-03-27 | Pits not liquid tight/Improper construction or use | |
0236826559 | US-OH-122368 | 2008-03-26 | Tanks not liquid tight/Improper burial | |
0236826559 | US-OH-122369 | 2008-03-27 | Failure to repair pits/Unlawful use of pits | |
0267787825 | US-OH-122764 | 2008-10-06 | Contamination at surface facility (permit before 6-1-82) | |
0267787825 | US-OH-122765 | 2008-09-29 | Permit not displayed | |
0441784917 | US-OH-124758 | 2017-06-15 | 9-3-05[C] | Failure to pass required test |
0479843378 | US-OH-125233 | 2008-02-22 | Contamination at surface facility (permit after 6-1-82) | |
0479843378 | US-OH-125234 | 2008-02-22 | Permit not displayed | |
0543640086 | US-OH-125959 | 2012-06-21 | Pollution/Contamination | |
0650841418 | US-OH-127377 | 2015-07-17 | Failure to monitor annulus pressure | |
0705372691 | US-OH-127963 | 2014-04-10 | Pollution/Contamination | |
0705372691 | US-OH-127964 | 2014-04-10 | Pits not liquid tight/Improper construction or use | |
0818713486 | US-OH-129326 | 2009-06-08 | Pollution/Contamination | |
0818713486 | US-OH-129327 | 2009-06-08 | Contamination at surface facility (permit before 6-1-82) | |
0849615643 | US-OH-129666 | 2009-11-10 | Inadequate pipeline strength | |
0849615643 | US-OH-129667 | 2009-11-10 | Leaking brine pipeline | |
0849615643 | US-OH-129668 | 2009-11-10 | Pollution/Contamination | |
0849615643 | US-OH-129669 | 2009-11-10 | Pits not liquid tight/Improper construction or use | |
1092938833 | US-OH-102177 | 2004-08-19 | Failure to legibly identify well | |
1092938833 | US-OH-102178 | 2004-08-19 | Pollution/Contamination | |
1092938833 | US-OH-102179 | 2004-08-19 | Failure to meet safety/distance requriements | |
1096616651 | US-OH-102311 | 2018-03-05 | 9-3-05[C] | Failure to pass required test |
1154697983 | US-OH-104050 | 2006-08-04 | Failure to legibly identify well | |
1154697983 | US-OH-104051 | 2006-08-04 | Pollution/Contamination | |
1154697983 | US-OH-104052 | 2006-08-04 | Contamination at surface facility (permit before 6-1-82) | |
1221052423 | US-OH-105959 | 2007-05-09 | Violation of injection tubing/fitting requirements | |
1237234076 | US-OH-106338 | 2018-03-27 | 9-3-05(A)6 | Contamination at surface facility (permit after 6-1-82) |
1334681705 | US-OH-109630 | 2012-04-17 | Equipment pressure rated below operating pressure | |
1334681705 | US-OH-109631 | 2012-04-17 | Pollution/Contamination | |
1442344801 | US-OH-112855 | 2015-10-08 | Failure to monitor annulus pressure | |
1492182530 | US-OH-113917 | 2017-06-19 | 9-3-05(B)7 | Contamination at surface facility (permit before 6-1-82) |
1694141788 | US-OH-116793 | 2003-01-30 | Failure to legibly identify well | |
1694141788 | US-OH-116794 | 2003-01-30 | Failure to meet safety/distance requriements | |
1786451260 | US-OH-117808 | 2011-04-06 | Mechanical failure/contamination | |
iTOMK00009 | US-OH-131639 | Violation of injection tubing/fitting requirements |