Well Details

Well ID: 34-073-22161
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Falls Township
Operator Name: JEANIE ENTERPRISES LLC
Well Pad ID:
Farm/Lease Name: ROBERTSON JOSEPHINE W
License Status: Active Injection
License Date: 1980-07-25
Spud Date: 1979-08-11
Spud Drilling Contractor: BEVERLY DRLG
Final Drill Date: 1979-08-16
Well Total Depth: 2608.00 ft
Configuration: Vertical
Latitude: 39.550000
Longitude: -82.450000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-06-05 133 QUAKER STATE OIL REF CORP GeoDate 6/5/79
Original Spud 1979-08-11 CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80
Completed 1979-08-16 CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80
Reached Total Depth 1979-08-16 CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80
Conversion to Injector 1980-07-25
First Injection 1980-11-05 CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80
Annulus Pressure Monitoring Approved 1986-09-09 CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80
CO 1991-09-16 456 SCHMELZER MARK GeoDate 6/5/79
Last Compliance Report 1999-01-25 CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80
Change of Owner 2007-08-30 Operator changed from 456, SCHMELZER MARK to 8268, JEANIE ENTERPISES LLC
Record Last Modified 2017-10-19 CONVERTED FROM OIL & GAS TO SWD IN 1980 CONVERT TO SWDW #1 7-25-80

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-04-28 2427 2456 1
2427 2456 1
2427 2456 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1764 Bbl 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 QUAKER STATE OIL REF CORP 0.00 0.00 0
1991 QUAKER STATE OIL REF CORP 0.00 0.00 365
2004 SCHMELZER MARK 0.00 0.00 365
2005 SCHMELZER MARK 0.00 0.00 365
2006 SCHMELZER MARK 0.00 0.00 365
2008 JEANIE ENTERPRISES LLC 0.00 0.00 365
2009 JEANIE ENTERPRISES LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 QUAKER STATE OIL REF CORP Brine 380 0
1991 QUAKER STATE OIL REF CORP Brine 80 365
2004 SCHMELZER MARK Brine 0 365
2005 SCHMELZER MARK Brine 0 365
2006 SCHMELZER MARK Brine 0 365
2008 JEANIE ENTERPRISES LLC Brine 0 365
2009 JEANIE ENTERPRISES LLC Brine 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1035524058 2009-6-16 0:00: SW No Violations
-1064307432 2018-3-26 0:00: SW No Violations 1.20
-1151851519 2018-8-7 0:00:0 SW No Violations 0.90
-1227268402 2009-10-7 0:00: SW No Violations
-1231390251 2008-3-7 0:00:0 SW No Violations
-1250056787 2019-11-27 0:00 SW No Violations 6.10
-1314429500 2009-3-3 0:00:0 SW No Violations
-1316048722 2009-9-2 0:00:0 SW No Violations
-1369593729 2017-5-23 0:00: SW No Violations 3.50
-1381422042 2011-3-31 0:00: SW No Violations
-1411064742 2012-6-18 0:00: SW No Violations 1.00
-1509815397 2012-8-20 0:00: SW No Violations 1.50
-1517342329 2018-8-14 0:00: SW No Violations 3.20
-1563744727 2017-4-26 0:00: SW No Violations 6.00
-1583357363 2012-1-16 0:00: AM No Violations 0.50
-1588795722 2012-12-5 0:00: SW No Violations 1.00
-1694141788 2003-1-29 0:00: SW No Violations
-174569852 2013-6-27 0:00: SW No Violations 2.00
-1776428409 2011-8-31 0:00: SW No Violations
-1786451260 2011-3-31 0:00: SW No Violations
-1796908120 2012-6-13 0:00: SW No Violations 1.00
-1888650687 2005-4-6 0:00:0 SW No Violations
-1938055957 2012-2-23 0:00: SW No Violations
-1956406417 2009-6-10 0:00: AM No Violations
-1964127281 2018-11-8 0:00: SW No Violations 1.50
-2080505699 2015-4-2 0:00:0 SW No Violations 6.00
-2081099343 2008-3-14 0:00: SW No Violations
-2091956777 2016-2-3 0:00:0 SW No Violations 2.50
-2115776822 2013-4-10 0:00: SW No Violations 3.00
-259096746 2010-12-28 0:00 SW No Violations 0.50
-267787825 2008-9-8 0:00:0 SW No Violations
-330363311 2005-3-3 0:00:0 SW No Violations
-33185135 2019-11-21 0:00 SW No Violations 3.00
-407543686 2017-3-28 0:00: SW No Violations 3.50
-472394746 2005-6-9 0:00:0 SW No Violations
-519295457 2003-6-19 0:00: SW No Violations
-525601398 2012-1-17 0:00: SW No Violations 2.50
-565489822 2012-6-18 0:00: SW No Violations
-574483130 2008-10-30 0:00 SW No Violations
-576223882 2007-6-20 0:00: SW No Violations
-632427697 2013-1-10 0:00: SW No Violations 1.00
-650841418 2015-6-18 0:00: SW No Violations 1.50
-682616630 2020-5-14 0:00: SW No Violations 3.50
-688348716 2008-3-20 0:00: SW No Violations
-774978176 2015-3-24 0:00: SW No Violations 1.00
-780999638 2003-12-9 0:00: SW No Violations
-818713486 2009-6-2 0:00:0 SW No Violations
-822760495 2007-10-30 0:00 SW No Violations
-83402969 2013-7-2 0:00:0 SW No Violations 4.00
-858432577 2008-3-13 0:00: SW No Violations
-885834854 2020-3-19 0:00: SW No Violations 2.00
-889993238 2012-1-25 0:00: SW No Violations 1.00
-902937421 2006-9-21 0:00: SW No Violations
-933669370 2012-6-20 0:00: SW No Violations 1.00
-966382051 2017-4-19 0:00: SW No Violations
-987799875 2003-7-24 0:00: SW No Violations
-994351388 2012-1-17 0:00: SW No Violations
00000UIC60 1987-01-05 Salt Water Injection Well No Violations 1501:9-3-07(H)
00000UIC61 1987-01-05 Salt Water Injection Well No Violations 1501:9-3-04(A)
00000UIC62 1987-01-05 Salt Water Injection Well No Violations 1501:9-3-05(B)(7)
0006591978 2011-12-15 Salt Water Injection Well No Violations Accompanied Jon Scott on inspection.
001269i210 2000-12-18 Production Wells No Violations FOLLOW - UP ON NOV , IN - COMPLIANCE .
001269i513 2001-11-13 Salt Water Injection Well No Violations No violations.
001269i698 2002-01-16 Salt Water Injection Well No Violations No violations.
0026429069 2019-01-15 Salt Water Injection Well No Violations Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification posted. Annulus was frozen.
005609i211 2001-06-04 Salt Water Injection Well No Violations
0083402969 2013-07-02 Salt Water Injection Well No Violations I accompanied Jon Scott for a line test. The test passed, see Jons report dated 07/02/2013 for results.
01269i1074 2002-05-22 Salt Water Injection Well No Violations Follow-up on NOV, In-Compliance. Unable to check pressures on well , do not have tools to remove plugs in valves.
01269i1398 2002-09-24 Salt Water Injection Well No Violations No violations at this time.
0136248629 2013-06-28 Salt Water Injection Well No Violations The dike is being rebuilt today, the plumbing where the leak was is also being repaired.
0161051084 2004-12-14 Salt Water Injection Well No Violations No violations.
0171417511 2016-05-03 Salt Water Injection Well No Violations Inspected the containment area, tanks, injection pressure and annulus pressure. Accompanied by the UIC Supervisor.
0174569852 2013-06-27 Salt Water Injection Well No Violations Danny Baker has pumped out the dike. The dike was then removed to allow for the placement of a dike that will be liquid tight. They are plumbing the pump to eliminate the brine leak.
0236826559 2008-03-06 Salt Water Injection Well Violations Noted An inspection revealed that one of the two 100 bbl saltwater drop tanks (located on Reed Road) was corroded and leaking at the bottom. A large trench located at a lower elevation serves as a catch basin. Fluid inside this trench was observed draining into a nearby creek. Quantabs (high range) showed 10 units near the source of the leak and location where the fluid drains into the creek. A new 100 bbl tank was observed at the entrance to the lease road. Contacted the owner, Jeanie Schmeltzer and pumper for the company. They were informed to resolve this issue immediately. The company states that they will have a water truck pump the trench today. And the fluid inside the leaking tank will be transferred over to the injection well. The pumper states that they found this leak on the 3/5/2008. A new 100 bbl tank was observed on-site. Dennis Deavers with OEPA was informed of the inspection results.
0259096746 2010-12-28 Salt Water Injection Well No Violations An inspection revealed no violations. The meter showed no change as 224481 bbls were observed. Snow cover at time of inspection.
0267787825 2008-09-08 Salt Water Injection Well Violations Noted An inspection revealed no identification at the storage tanks. The identification card placed at the well was found to contain only the previous companies name. No additional information was observed. Identification was not observed at the storage tanks. Contamination and pollution was observed at the unloading pad. The company was contacted by telephone and informed of the inspection results.
0291345184 2013-04-10 Surface Facility Construction No Violations Injection line test. Attempted to test injection line two times. A leak was found on a 2 union. The leak was not able to be repaired during the inspection. The line test will be rescheduled after repairs are made. No injection until the line is tested and passed. Inspector Kip Thompson accompanied me on the test.
0330363311 2005-03-03 Salt Water Injection Well No Violations No violations.
0379760063 2013-07-11 Salt Water Injection Well No Violations Danny Baker has rebuilt the dike and repaired the plumbing on the pump. The leaks have been fixed and the dike has been rebuilt with clay from Logan clay. This satisfies the compliance notice.
0384859649 2015-09-17 Salt Water Injection Well No Violations Witnessed a mini test on the annulus. Tested at 410 psi for 15 minutes with a loss of 5 psi. A small leak was observed on a 1/4 ball valve on the annulus during the test. Danny Baker said they will replace the valve.
0407543686 2017-03-28 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted on the tank and well site. The containment dike is free of fluids.
0441784917 2017-05-25 Salt Water Injection Well Violations Noted Salt water injection well inspection. The well had 23 psi on the injection tubing and 0 psi on the annulus. The well will need a mechanical integrity test to determine if the well has mechanical integrity.
0472394746 2005-06-09 Salt Water Injection Well No Violations No violations
0479843378 2008-02-11 Salt Water Injection Well Violations Noted An inspection revealed that a 210 bbl storage tank has overflowed onto the ground surface. The impacted areas ranged from 1-2 ft sections outside the concrete dike placed around the storage tanks,and a 10x20ft section around the unloading pad. An earthen impoundment was also found to be impacted. A 5x3 ft section of oil was observed. This source of water containment does not lead to a creek or stream. Equipment (mini excavator) and cleanup supplies were observed on-site. Also noted was that new identification would be needed at the well head. The company, Jeanie Enterprises, and the pumper, Mr. Danny Baker, were both contacted and informed of inspection results. Mr. Baker states that they have been working on cleanup and have taken oily soils to the landfill and will provide run tickets. He was informed that the impoundment will also need to be addressed along with the areas outside the dike.
0488943911 2013-01-10 Salt Water Injection Well No Violations Inspected salt water injection well injection tubing pressure and annulus pressure. Good identification at well head. Steel injection line has been installed in an open ditch. Currently waiting on company to test the injection line from the tank battery to the well. Injection operations are shut down waiting on the line test and the replacement of the brine pump. Accompanied by Andy Thomas MRI 2.
0519295457 2003-06-19 Salt Water Injection Well No Violations No violations.
0525601398 2012-01-17 Salt Water Injection Well No Violations When I arrived at the tank battery, the injection pump was running. I immediately called Danny Baker and told him that an injection line test needed to be administered, and witnessed by the state before he could run the pump. This test was supposed to have taken place in the summer of 2011. I was then joined by Jon Scott south region UIC inspector. When Danny Baker arrived with his crew, two attempts were made to test the flow line. Both had failed. Inspector Kip Thompson was also present on this inspection.
0543640086 2012-06-13 Salt Water Injection Well Violations Noted Concrete containment at the tank battery was full of fluid. The vault was also full and had appeared to had flown over. Mr. Danny Baker was called immediately. He stated that he would be out promptly to take care of the situation. He also stated that the problem was due to a tank overflow. We agreed that absobant material would be used to soak fluid up and then material would be shoveled out an hauled to an approved landfill. I checked back later on the same day and the vault had been pumped out.
0565489822 2012-06-18 Salt Water Injection Well No Violations Follow up with Andy Thomas MRI 2 at dike. Oil spill in dike has been cleaned up. Dike is free of oil. No oil on the ground near the concrete vault. Brine contaminated soil has not been removed.
0574483130 2008-10-30 Salt Water Injection Well No Violations A follow-up inspection revealed that the violations have been resolved.
0576223882 2007-06-20 Salt Water Injection Well No Violations A follow-up inspection revealed non-compliance.
0584529606 2011-12-15 Salt Water Injection Well No Violations Accompanied by Andy Thomas MRI. New identification at wellhead has fallen on the ground.
0632427697 2013-01-10 Salt Water Injection Well No Violations Checked injection and annulus pressures at the well. A trench had been dug and new injection line had been laid in it. We are still awaiting an injection line test. Well was not injecting at the time of inspection. Accompanied by Jon Scott.
0650841418 2015-06-18 Salt Water Injection Well Violations Noted Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification was not legible on the tanks and was not seen at the well site. Post identification at the surface facility and the well. The annulus pressure was on vacuum. Must maintain a positive pressure on the annulus. A mini test needs to be scheduled with the inspector. A call was placed to the company regarding the violations on 6-18-15.
0688348716 2008-03-20 Salt Water Injection Well No Violations A follow-up inspection revealed non-compliance. More work needed around the drop tank location.
0705372691 2013-06-26 Salt Water Injection Well Violations Noted I conducted a inspection of the lift pump station. This pump lifts brine to flow to their injection well. The fittings on the pump are leaking, the brine is being collected in a pit. The pit is not liquid tight allowing brine to leach thru. I sampled the brine using high range chloride titrators. I sampled two areas both samples registered 2400 PPM chlorides. Mark Smeltzer shut the pump off at 1322 hours. I asked the pump not be used until the leak is corrected and the dike is made liquid tight. The pumping station is located on reed road.
0729392706 2018-05-15 Salt Water Injection Well No Violations Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification is posted.
0748798232 2015-09-23 Surface Facility Construction No Violations Surface facility inspection with UIC section Geologist.
0754870566 2004-09-24 Salt Water Injection Well No Violations No violations.
0774978176 2015-03-24 Salt Water Injection Well No Violations UIC inspection, there is some oil and water in the dike. I called Danny Baker to have the dike pumped out. The injection well has 12 PSI on the injection side, the annulus has 0 pressure. I have contacted Jeanie Enterprises to perform a mini test.
0780999638 2003-12-09 Salt Water Injection Well No Violations No violations.
0794724910 2017-04-18 Salt Water Injection Well No Violations Compliance notice follow-up. Danny Baker with Baker Enterprises is removing the brine contaminated soil. The soil was removed and I sampled the remaining soil to determine if contained any chlorides. I tested the soil using quantabs to determine the quantity of the chlorides. The soil that was removed was stocked piled on site and a dike was placed around the soil. This soil will be taken to a landfill on 4-19-17.
0818713486 2009-06-02 Salt Water Injection Well Violations Noted An inspection of the SWIW and related storage tanks was conducted with Mr. Jeff Fry. During the inspection, an old bare area with exposed flowline were observed below the storage tanks located in a low lying area near the creek. Note: Timber has been removed from this locaton, but signs of stressed vegetation were noted. It was also noted that general housekeeping would be needed at the unloading pad/concrete vault location. Old oil found around the concrete vault and appeared to be breaking down. Old filters along with a drum containing oily debris, which may have leaked would need to be placed inside dike to avoid leakage. At the time of the inspection, the meter showed 224,481 bbls. Left voice mail message for the pumper, Mr. Danny Baker with Jeanie Enterprises on 6/2/2009 at 2:12 pm, in regards to the inspection. Mr. Baker returned call on 6/3/2009 and confirmed line break over the hill last year. Mr. Baker was instructed to place lime, seed and mulch on the impacted area. Perform general housekeeping and recommended filters and drum placed inside dike.
0822760495 2007-10-30 Salt Water Injection Well No Violations No violations were noted.
0849615643 2009-10-01 Salt Water Injection Well Violations Noted An inspection of the saltwater drop or pump station to Roberston (SWIW #1) was conducted. The facility contains only one (1) 100 bbl. The second 100 bbl that contained a hole and was leaking has now been removed. Currently, the existing 100 bbl contains a leak (approx 1 drip every 10 sec) on bottom at valve with swage before connection to PVC elbow fitting. A rag has been placed around the leak. High Range Quantabs exceeded 10 units of Cl-. Note: 8.4 units equals 6545 ppm (mg/L) of Cl-. The attached line is 2 Sch 40 PVC pipe routed to pump house (inlet). A leak was also observed at this location (inlet to pump). 1 drip approx every 60 seconds. The outlet is 2 steel from pump house uphill to SWIW. Old oil observed a pump house with wood chips placed around location. The oil came derives from a rotted steel line that had been repaired. Wash from rainfall events drains from location (pump house and tank) to creek approx 30 and 10 away respectively. The earthen dike around 100bbl tank contains a trench. The pumper, Mr. Danny Baker arrived at location during inspection. He was instructed of deficiencies and made attempt to stop leaks. Mr. Baker states cleanup, dike and water diversion will be done next week.
0855206324 2013-09-03 Salt Water Injection Well No Violations UIC inspection, the injection well was not in use. The well was being worked on, the filter canister was being repaired.
0858432577 2008-03-13 Salt Water Injection Well No Violations A follow-up inspection regarding the leak from a saltwater drop tank (Reed Road) revealed non-compliance. The fluid inside the trench showed 3.8 units on Quantabs (High Range), but was not discharging into the creek. More fluid will need to be pumped from this trench. An elbow fitting, on a steel flow line, that crosses the creek was observed to contain a small leak. Quantab showed maximum of 10 units. The company was contacted and informed of the inspection results.
0889993238 2012-01-25 Salt Water Injection Well No Violations I witnessed the injection line test with inspectors Jon Scott and Kip Thompson. The line held 840 pounds of pressure for 15 minutes.
0891579285 2017-04-20 Salt Water Injection Well No Violations Danny Baker with Baker Oil Field Services has emptied the 100 barrel tank and moved the tank to allow removal of the brine contaminated soil that was under the tank. The dike will be rebuilt using a liner.
0902937421 2006-09-21 Salt Water Injection Well No Violations A follow-up inspection was conducted at the facility owned by Mr. Mark Schmelzer on 9/21/2006. During the inspection, it was noted that the previously noted violations have been resolved.
0933669370 2012-06-20 Salt Water Injection Well No Violations Inspected transfer pump facility off of Reed Rd. A new piece of pipe had been installed where the old one had been leaking. No leak detected.
0934148653 2008-02-25 Salt Water Injection Well No Violations A follow-up inspection revealed that company has been performing cleanup. However, more work will be needed.
0963089080 2014-07-30 Salt Water Injection Well No Violations Saltwater injection well inspection. The injection pressure was 28 PSI, the annulus pressure was 0 PSI. I have contacted Danny Baker to conduct a mini test to ensure casing integrity.
0966382051 2017-04-19 Salt Water Injection Well No Violations Danny Baker with Baker Oil Field Services is removing brine contaminated soil from the below the dike and the soil inside the dike. The tank will be moved to allow removal of soil under the tank. The steel production lines are being replaced and a new Murphy switch is being installed. The contaminated soil will be disposed of at Kilbargers landfill. I used low range and high range quantabs to determine the amount of soil that needed to be removed.
0987799875 2003-07-24 Salt Water Injection Well No Violations No violations
0994351388 2012-01-17 Salt Water Injection Well No Violations 1-16-12 Received call from Andy Thomas MRI, that a brine tank had flowed over and into the dike. 1-17-12 made arrangements to meet at tank battery. The tanks had been recently wiped down and the dike had been cleaned out. The spill was contained with in the dike. The injection line from the pump to the injection well has been worked on recently and I requested that they test the line to show mechanical integrity. Two attempts were made to test the injection line. Both attempts were unsuccessful. The pumper requested that they shut down the injection and make repairs to the line on the 1-18-12 then re-test on 1-19-12.
1035524058 2009-06-16 Salt Water Injection Well No Violations An inspection of the impacted area from line break location revealed the application of lime, seed and mulch to a 50 x 50 area. Note: Company employee states that line broke in Fall 2008.
1046961243 2003-03-04 Salt Water Injection Well No Violations Follow-up on NOV, Non-Compliance, company has not rewrote ID or hung electric line.
1052748940 2003-05-06 Salt Water Injection Well No Violations Follow-up on NOV, In-Compliance.
1064307432 2018-03-26 Salt Water Injection Well No Violations The salt water injection well had 0 psi on the injection tubing, The annulus was on vacuum. I have contacted Jeanie Enterprises to have mechanical integrity test performed to prove the there is no communication between the tubing and the annulus. I called Mr. Mark Schmeltzer at 0923 hours. I was unable to leave a message. I then called Mr. Danny Baker at 0935 hours and told Mr. Baker that a mechanical integrity test would be required to prove there was no communication.
1075413650 2004-01-27 Salt Water Injection Well No Violations No violations.
1078149911 2004-02-26 Salt Water Injection Well No Violations No violations.
1092938833 2004-08-19 Salt Water Injection Well Violations Noted An inspection of the well revealed ID needs rewrote at well and tank battery, oily soil around storage tanks needs cleaned up. NEW LAT & LONG
1096616651 2018-01-24 Salt Water Injection Well Violations Noted The salt water injection wells annulus was on vacuum and the injection tubing was also on vacuum. I have issued a compliance notice to have the well tested to ensure that there is no communication between the annulus and the injection tubing. I called Jeanie Enterprises and informed them of the violation and they agreed to perform a MIT test as soon as possible.
1129194392 2017-05-31 Salt Water Injection Well No Violations Compliance notice follow-up. The well was pressure tested today at 471 PSI for 15 minutes with no loss. The well passed the mechanical integrity test.
1131146540 2016-11-14 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The 1/4 inch annulus valve handle was slightly open. The annulus had zero pressure.
1151851519 2018-08-07 Salt Water Injection Well No Violations Inspected the containment area, tanks, injection pressure and annulus pressure. Identification is posted at the well and facility.
1154697983 2006-07-25 Salt Water Injection Well Violations Noted An inspection was conducted at the facility owned by Mr. Mark Schmelzer on 7/25/2006. During the inspection, it was noted that the injection line had a small pinhole leak in the injection line. As a result, brine was being discharged directly onto the ground surface. Also noted was that the surrounding area contained dead vegetation. Mrs. Gene Schmelzer was immediately contacted by telephone @11:15am on 7/25/2006. She was informed to correct this problem immediately. In regards to the SWIW inspection, it was found that a ID will be needed at the well. The ID the storage tanks contains the wrong area code. The dike needs to be pumped and the oily soil and material needs to be removed from the lease. On 7/28/2006, a follow-up inspection was conducted to ensure that the leaking fitting has been replaced. During the inspection, it was noted that the fitting was replaced and straw had been applied to the surrounding area.
1154992731 2006-07-28 Salt Water Injection Well No Violations During the insspection conducted on 7/28/2006, it was noted that the leaking injection fitting was replaced. Straw was applied to the surrounding area.
1168620032 2007-01-10 Salt Water Injection Well No Violations No violations were noted during the inspection.
1173076558 2009-07-07 Surface Facility Construction No Violations A follow-up inspection revealed compliance.
1206865706 2016-03-21 Salt Water Injection Well No Violations Inspected the containment area, tanks, injection pump, injection pressure, and annulus pressure. Identification posted on the tank. Containment is free of fluids.
1207012412 2008-03-31 Salt Water Injection Well No Violations A follow-up inspection conducted on saltwater drop tanks revealed that the trench has been filled, area graded and 100 bbl tanks removed. The elbow fitting that contained a small leak has been repaired. The company is removing abandoned steel flow lines and re-routing a section of the active flow line to the SWIW. Seed and mulch will be applied to the area. Contamination and pollution has been taken to the landfill. The wells tied into the drop tanks (saltwater) have been shut-down, until new tanks are installed and a dike has been constructed.
1211473626 2008-05-21 Salt Water Injection Well No Violations No violations
1221052423 2007-04-24 Salt Water Injection Well Violations Noted An inspection revealed that a new 1/4 inch valve is needed on the injection side of the well.
1227268402 2009-10-07 Salt Water Injection Well No Violations A follow-up inspection revealed non-compliance.
1231390251 2008-03-07 Salt Water Injection Well No Violations A follow-up inspection was conducted at the Robertson SWIW. More cleanup will be needed inside the earthen impoundment located near the storage tanks.
1237234076 2017-10-19 Salt Water Injection Well Violations Noted My inspection revealed the injection facility has a oil stain next to the brine vault. The stain is approximately 2 feet by 2 feet. I contacted Mr. Danny Baker to have the oil stain removed.
1257863060 2009-11-10 Salt Water Injection Well No Violations A follow-up inspection revealed compliance. The earthen dike has been addressed, leaks stopped and location graded.
1259912222 2010-06-24 Salt Water Injection Well No Violations An inspection revealed no violations.
1268765138 2010-03-16 Salt Water Injection Well No Violations An inspection revealed no violations at this time. The bbl counter at storage tank(s) location showed 224481.
1269i1074 2002-5-22 0:00: SW No Violations
1269i11751 2001-03-27 Salt Water Injection Well No Violations No violations
1269i11751146 2001-3-27 0:00: SW No Violations
1269i1398 2002-9-24 0:00: SW No Violations
1269i210 2000-12-18 0:00 PW No Violations
1269i513 2001-11-13 0:00 SW No Violations
1269i698 2002-1-16 0:00: SW No Violations
1269i87457 2002-03-19 Salt Water Injection Well No Violations An inspection of the well revealed that the pump is leaking brine, the pump needs repaired or replaced.
1269i87457142 2002-3-19 0:00: SW No Violations
1285691603 2010-09-27 Salt Water Injection Well No Violations An inspection revealed no violations. The barrel counter at storage tank location showed 224,481. Note: The gauge utilized for this inspection will require calibration.
1314429500 2009-03-03 Salt Water Injection Well No Violations An inspection revealed no violations at this time.
1316048722 2009-09-02 Salt Water Injection Well No Violations An inspection revealed that general housekeeping has been performed at the tank battery location. The meter at the tank battery location showed 224481 bbl. Vegetative growth also observed, in patches, at the line break location.
1334681705 2012-04-16 Salt Water Injection Well Violations Noted Conducted an inspection on transfer pump facility off of Reed Rd. North of Logan. GPS coordinates N 39.56988, W 82.43575. Due to lack of vegetation, it was suspected that there had been a brine spill. Quantab results from a puddle of water in the vegetation kill area showed that the chloride content was too high for the Quantab to quantify. Mr. Danny Baker was notified by a phone call, and instructed to remediate soil where the vegetation was killed and build a containment dike around the pump because Mr. Baker had suspected it was leaking. He was also advised of other potential plumbing risks associated with the pump. Mr. Baker stated that he would be out there the following day with a piece of equipment to remediate situation.
1346582948 2008-03-06 Salt Water Injection Well No Violations Witnessed a water truck pump out the trench containing brine. The company is transferring brine from the leaking tank to the Robertson SWIW. More fluid will need to be pumped out of the trench and tank will need to repaired or replaced.
1354714952 2012-12-04 Salt Water Injection Well No Violations The purpose of the inspection was to witness and injection line test. The company was not ready to perform the test when I arrived. They had detected a leak and were looking for it. Accompanied by Andrew Adgate and Steve riley.
1358743542 2009-12-03 Salt Water Injection Well No Violations An inspection revealed no violations at this time. The meter at the tank battery location showed 224481 bbl.
136248629 2013-6-28 0:00: SW No Violations 3.00
1369593729 2017-05-23 Salt Water Injection Well No Violations Danny Baker has continued to remove brine contaminated soil. 33 tons of soil has been taken to a approved landfill for disposal. I checked the soil and found approximately 980 PPM chlorides remain. The soil will be removed until the chloride content is at or below 250 PPM.
1372851473 2013-07-02 Salt Water Injection Well No Violations Injection line pressure test. Tested steel line from surface facility to the well at 795 psi for 15 minutes with no loss in pressure. Inspector Kip Thompson witnessed Danny Baker open the master valve on the well head after the test. The gauge at the surface facility dropped from 795 psi to 20 psi when the master valve was opened.
1378604987 2008-02-26 Salt Water Injection Well No Violations A follow-up inspection revealed non-compliance.
1381422042 2011-03-31 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -1786451260 Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break.
1403721816 2004-04-01 Salt Water Injection Well No Violations No violations.
1407509652 2014-08-08 Salt Water Injection Well No Violations UIC inspection, I requested a MIT test to ensure their was no communication between the injection zone and the annulus. The test was held for 15 minutes for 305 PSI with no loss.
1411064742 2012-06-18 Salt Water Injection Well No Violations Accompanied by inspector Jon Scott. Observed what clean up had been performed. Bags filled with contaminated soil were still loaded on a roll back truck. Clean up had also been performed around vault where it had overflowed.
1413903286 2014-10-21 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The containment vault lid was off. The fluid level in the vault was low. A new sump pump appears to have been installed. New identification was posted at the well.
1422457871 2015-01-28 Salt Water Injection Well No Violations UIC inspection, the injection pressure was 11 PSI. The annulus pressure was 2 PSI.
1435168223 2015-06-24 Salt Water Injection Well No Violations Compliance notice follow up. Mechanical Integrity Test. Tested annulus at 760 psi. At 15 minutes test pressure was 740 psi. Test passed. Identification is posted. Inspected the injection pressure.
1442344801 2015-09-14 Salt Water Injection Well Violations Noted Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification on tanks did not have API number. Identification at well was complete. Annulus was on vacuum and injection tubing was at zero pressure. I called Danny Baker and told him that they will need to test the annulus and that they need to post a complete identification at the facility.
1454207791 2009-10-14 Salt Water Injection Well No Violations A follow-up inspection revealed that the leaks have been addressed. Work has been done on earthen dike, but not completed. The location will also be graded.
1455912811 2016-02-18 Salt Water Injection Well No Violations Injection line test. Injection line was pressure tested at 1040 psi for 15 minutes with no loss. Witnessed the test and the release of pressure after opening the injection tubing master valve. Test passed.
1472491286 2016-08-29 Salt Water Injection Well No Violations Inspected the containment area, tanks, injection pump, injection pressure and annulus pressure. Identification posted on the tank.
1492182530 2017-04-14 Salt Water Injection Well Violations Noted My inspection revealed a area of ground below the dike that was covered with straw. The 100 barrel tank that holds salt water had run over and spilled salt water down hill. The spill is approximately 22 feet by 31 feet. I used high range and low range quantabs to check for salinity. I used 3 quantabs and found a average reading of 2200 PPM. I met Danny Baker on site and he agreed to clean up the soil that was contaminated with brine. I called Emergency Response and reported the spill.
1509815397 2012-08-20 Salt Water Injection Well No Violations Well and tank battery are in compliance.
1511436599 2014-01-09 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection line, Injection pressure, and annulus pressure. Identification posted on tank with-in the containment dike. Activity around the surface facility includes removal of a portion of fencing near the road, removal of debris and brush from inside remaining fenced area. New rolls of plastic pipe are on location.
1517342329 2018-08-14 Salt Water Injection Well No Violations Surface facility inspection with ODNR DOGRM UIC Geologist.
1519320400 2018-02-22 Salt Water Injection Well No Violations My inspection revealed the pollution and contamination has been removed. This satisfies the compliance notice.
1554414865 2014-03-11 Salt Water Injection Well No Violations UIC inspection. I checked the injection well, the injection pressure was 0. The annulus pressure was 0. I contacted Danny Baker to conduct a 300 PSI mini test to ensure the annulus would hold pressure.
1563744727 2017-04-26 Salt Water Injection Well No Violations Mr. Danny Baker on site removing contaminated soil from the dike. The 100 barrel tank has been removed to allow removal of contaminated soil that is below the tank. Approximately 2.5 feet of soil has been removed and taken to the landfill. I have tested the soil at this level and found chloride content to be approximately 1600 PPM. I told Mr. Baker soil would need removed until the chloride content was below 250 PPM.
1583357363 2012-01-16 Administrative Inspection No Violations I received a phone call from Walter Borne at 10:25 am. He stated that the tank battery for this well was overflowing. I then placed a phone call to Danny Baker who is an employee of Jeanie Enterprises and told him what was going on. He said that he would go straight there and take care of it.
1588795722 2012-12-05 Salt Water Injection Well No Violations There was nobody on site when I arrived. Called Danny Baker and he was on his way. One section of pipe still needed replaced on the injection line.
1589454858 2020-5-13 0:00: SW No Violations 3.50
1594209925 2020-7-6 0:00:0 SW No Violations 3.50
161051084 2004-12-14 0:00 SW No Violations
1642470419 2004-05-27 Salt Water Injection Well No Violations No violations
1665678183 2012-01-25 Salt Water Injection Well No Violations Test 2 steel injection line from the pump (in tank dike) to the salt water injection well. Tested at 850 pounds per square inch for 15 minutes with no loss. Opened master valve on injection tubing and witnessed pressure drop. Test passed.
1694141788 2003-01-29 Salt Water Injection Well Violations Noted An inspection of the well revealed the ID needs REWOTE at the well and tanks, an electric line running along tank battery needs HUNG back up.
171417511 2016-5-3 0:00:0 SW No Violations 3.50
1776428409 2011-08-31 Salt Water Injection Well No Violations Faded Identification at well.
1786451260 2011-03-31 Salt Water Injection Well Violations Noted Identification faded at well head. No identification at tank battery. Refresh well identification. 2inch steel injection line from tank battery to injection well is separated on hillside. Repair injection line and schedule a line test with Inspector Jon Scott. Call 740-624-4963. Clean up all contaminated soil associated with the line break.
1796908120 2012-06-13 Salt Water Injection Well No Violations I conducted an inspection on the transfer pump facility on Reed Rd with Jon Scott Inspector 3 South region. We found that there was a flow line leak at the pump at an elbow. It dripped once every 30 seconds. Mr. Danny Baker was notified of this immediately. He stated that he would be out to fix it promptly.
1805235116 2018-03-20 Salt Water Injection Well No Violations The salt water injection well had 0 psi on the injection tubing and 4 psi on the annulus. The dike was reasonably free of fluids. Legible identification was posted.
1880257932 2007-08-13 Salt Water Injection Well No Violations A follow-up inspection revealed that the well is in-compliance.
1888650687 2005-04-06 Salt Water Injection Well No Violations No violations.
1930017565 2020-6-30 0:00: SW No Violations 6.60
1938055957 2012-02-23 Salt Water Injection Well No Violations Injection pump operating during inspection.
1939052819 2012-06-14 Salt Water Injection Well No Violations Checked on clean-up efforts performed by Mr. Danny Baker and company. Fluid had been absorbed and material bagged up and placed on a roll back truck.
1941229516 2014-03-13 Salt Water Injection Well No Violations Compliance notice follow-up. The pit has been rebuilt and the leaking pump has been rebuilt. This satisfies the compliance notice.
1956406417 2009-06-10 Administrative Inspection No Violations The pumper for Jeanie Enterprises called at 3:20 PM and stated that 10 lb with lime, seed and mulch applied to line break location.
1964127281 2018-11-08 Salt Water Injection Well No Violations On Site with UIC Supervisor. Inspected the containment area, tanks, injection pump, vault, injection pressure and annulus pressure. Identification is posted. Containment area is free of fluids. The vault is full of fluid. I called Danny Baker and told him the vault was full. Danny told me that he will pump it into the tank for disposal. We also discussed the need to keep positive pressure on the annulus. Danny told me that he will schedule a test soon.
2013704891 2012-04-17 Salt Water Injection Well No Violations Witnessed remedial work performed by Mr. Danny Baker on the transfer pump facility off of Reed Rd., Logan.
2032038049 2008-03-26 Salt Water Injection Well No Violations A follow-up inspection revealed that the cleanup has been performed around the storage tank location. The company will be providing a run ticket for contaminated soil. The previously noted violations have been resolved.
2080505699 2015-04-02 Salt Water Injection Well No Violations UIC inspection. Baker Oilfield Services on site to perform a mini test. The test was held at 310 PSI for 15 minutes. Their was no loss in pressure for the duration of the test.
2081099343 2008-03-14 Salt Water Injection Well No Violations A follow-up inspection revealed non-compliance. C&P still observed at the storage tanks.
2082007621 2008-03-21 Salt Water Injection Well No Violations A follow-up inspection revealed that cleanup has been performed around the unloading pad. It was noted that more work will be required around the earthen impoundment .
2091956777 2016-02-03 Salt Water Injection Well No Violations Inspected the containment area, tanks, injection pump, injection line, injection pressure and annulus pressure. A section of the injection line has been recently replaced. I called Danny Baker and asked about this replacement. Danny told me that the line was replaced as an upgrade to the facility. I told Danny that the line must be tested. A test is scheduled for the week of 2-8-16.
2100817012 2012-11-27 Salt Water Injection Well No Violations There was a small amount of contamination inside the containment dike, and some general housekeeping needs performed on site. Left a message on Mr. Danny Bakers phone to make him aware of this. Everything else is in compliance. Spoke with Mr. Baker later on on Wednesday 11/28/12 at 8:47 am and he agreed to cleaning the site up. He stated that he had plans to do so anyway.
2103857190 2017-12-19 Salt Water Injection Well No Violations My inspection revealed the salt water injection well is in compliance. The brine spill has been cleaned. This satisfies the compliance notice.
2115776822 2013-04-10 Salt Water Injection Well No Violations UIC training with Jon Scott, see Jon Scotts report for details.
2125323217 2019-5-14 0:00: SW No Violations 4.50
2145792277 2003-10-27 Salt Water Injection Well No Violations No violations
236826559 2008-3-6 0:00:0 SW No Violations
26429069 2019-1-15 0:00: SW No Violations 2.00
291345184 2013-4-10 0:00: SC No Violations 4.00
379760063 2013-7-11 0:00: SW No Violations 1.00
384859649 2015-9-17 0:00: SW No Violations 3.00
441784917 2017-5-25 0:00: SW No Violations
454710540 2020-6-29 0:00: SC No Violations 0.50
479843378 2008-2-11 0:00: SW No Violations
488943911 2013-1-10 0:00: SW No Violations 1.00
543640086 2012-6-13 0:00: SW No Violations 2.00
5609i211 2001-6-4 0:00:0 SW No Violations
584529606 2011-12-15 0:00 SW No Violations
6591978 2011-12-15 0:00 SW No Violations 1.50
667774724 2019-7-10 0:00: SW No Violations 1.20
705372691 2013-6-26 0:00: SW No Violations 4.00
729392706 2018-5-15 0:00: SW No Violations 0.70
748798232 2015-9-23 0:00: SC No Violations 2.00
754870566 2004-9-24 0:00: SW No Violations
794724910 2017-4-18 0:00: SW No Violations 4.00
849615643 2009-10-1 0:00: SW No Violations
855206324 2013-9-3 0:00:0 SW No Violations 2.00
891579285 2017-4-20 0:00: SW No Violations 2.00
934148653 2008-2-25 0:00: SW No Violations
963089080 2014-7-30 0:00: SW No Violations 2.00
iTOMK00007 2000-08-01 Salt Water Injection Well No Violations SWIW#1
iTOMK000077 2000-8-1 0:00:0 SW No Violations
iTOMK00009 2000-11-15 Salt Water Injection Well Violations Noted
iTOMK000098 2000-11-15 0:00 SW No Violations
UIC60 1987-1-5 0:00:0 SW No Violations
UIC61 1987-1-5 0:00:0 SW No Violations
UIC62 1987-1-5 0:00:0 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0236826559 US-OH-122366 2008-03-26 Pollution/Contamination
0236826559 US-OH-122367 2008-03-27 Pits not liquid tight/Improper construction or use
0236826559 US-OH-122368 2008-03-26 Tanks not liquid tight/Improper burial
0236826559 US-OH-122369 2008-03-27 Failure to repair pits/Unlawful use of pits
0267787825 US-OH-122764 2008-10-06 Contamination at surface facility (permit before 6-1-82)
0267787825 US-OH-122765 2008-09-29 Permit not displayed
0441784917 US-OH-124758 2017-06-15 9-3-05[C] Failure to pass required test
0479843378 US-OH-125233 2008-02-22 Contamination at surface facility (permit after 6-1-82)
0479843378 US-OH-125234 2008-02-22 Permit not displayed
0543640086 US-OH-125959 2012-06-21 Pollution/Contamination
0650841418 US-OH-127377 2015-07-17 Failure to monitor annulus pressure
0705372691 US-OH-127963 2014-04-10 Pollution/Contamination
0705372691 US-OH-127964 2014-04-10 Pits not liquid tight/Improper construction or use
0818713486 US-OH-129326 2009-06-08 Pollution/Contamination
0818713486 US-OH-129327 2009-06-08 Contamination at surface facility (permit before 6-1-82)
0849615643 US-OH-129666 2009-11-10 Inadequate pipeline strength
0849615643 US-OH-129667 2009-11-10 Leaking brine pipeline
0849615643 US-OH-129668 2009-11-10 Pollution/Contamination
0849615643 US-OH-129669 2009-11-10 Pits not liquid tight/Improper construction or use
1092938833 US-OH-102177 2004-08-19 Failure to legibly identify well
1092938833 US-OH-102178 2004-08-19 Pollution/Contamination
1092938833 US-OH-102179 2004-08-19 Failure to meet safety/distance requriements
1096616651 US-OH-102311 2018-03-05 9-3-05[C] Failure to pass required test
1154697983 US-OH-104050 2006-08-04 Failure to legibly identify well
1154697983 US-OH-104051 2006-08-04 Pollution/Contamination
1154697983 US-OH-104052 2006-08-04 Contamination at surface facility (permit before 6-1-82)
1221052423 US-OH-105959 2007-05-09 Violation of injection tubing/fitting requirements
1237234076 US-OH-106338 2018-03-27 9-3-05(A)6 Contamination at surface facility (permit after 6-1-82)
1334681705 US-OH-109630 2012-04-17 Equipment pressure rated below operating pressure
1334681705 US-OH-109631 2012-04-17 Pollution/Contamination
1442344801 US-OH-112855 2015-10-08 Failure to monitor annulus pressure
1492182530 US-OH-113917 2017-06-19 9-3-05(B)7 Contamination at surface facility (permit before 6-1-82)
1694141788 US-OH-116793 2003-01-30 Failure to legibly identify well
1694141788 US-OH-116794 2003-01-30 Failure to meet safety/distance requriements
1786451260 US-OH-117808 2011-04-06 Mechanical failure/contamination
iTOMK00009 US-OH-131639 Violation of injection tubing/fitting requirements

For data sources see[9]