== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-155-24052
 
| Well ID: 34-155-24052
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.1535748, -80.61334206 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.153517280, -80.61354578 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Trumbull County, Ohio|Trumbull]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Trumbull_County,_Ohio|Trumbull]]
 +
|-
 +
| Municipality: [[Hubbard,_Ohio|Hubbard]]
 
|-
 
|-
 
| Operator Name: [[PAC DRILLING LLC]]
 
| Operator Name: [[PAC DRILLING LLC]]
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: FILICKY
 
|-
 
|-
| First Permit Date:  
+
| License Status: Producing
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2012-07-16
 
|-
 
|-
 
| Spud Date: 2012-01-16
 
| Spud Date: 2012-01-16
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor: [[G & H DRLG]]
|-
 
| Configuration: Vertical
 
 
|-
 
|-
| Well Status: Producing
+
| Final Drill Date: 2012-01-21
 
|-
 
|-
| Violations: 0
+
| Well Total Depth: 5354 ft
 
|-
 
|-
| Latitude: 41.1535748
+
| Configuration: Vertical
 
|-
 
|-
| Longitude: -80.61334206
+
| Latitude: 41.153517280
 
|-
 
|-
 +
| Longitude: -80.61354578
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Well Status
!scope="col" | GAS QUANTITY
+
!scope="col" style="width: 15%;text-align: center"| Well Status Date
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Comment
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-0
+
| APP
| style="text-align:right;" | 15805.0
+
| 2012-01-05
 +
| Proposed Formations:CLINTON/MEDINA, Issued Date:1/5/2012, Expired Date:1/4/2014 12:00:00 PM, Drilling unit acres:41.45, Proposed Well Type:OG, Proposed Well Class:POOL
 +
|-
 +
| Reached Total Depth
 +
| 2012-01-21
 
|  
 
|  
 +
|-
 +
| Completion Report Received
 +
| 2012-06-21
 
|  
 
|  
 +
|-
 +
| Construction Permit Expires
 +
| 2013-01-04
 
|  
 
|  
| style="text-align:right;" | 965.0
+
|-
 +
| Record Last Modified
 +
| 2017-10-24
 
|  
 
|  
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
| 2012-07-16
 +
| style="text-align: right;" | 5026
 +
| style="text-align: right;" | 5030
 +
| style="text-align: right;" | 5
 +
|-
 +
| 2012-07-16
 +
| style="text-align: right;" | 5042
 +
| style="text-align: right;" | 5044
 +
| style="text-align: right;" | 3
 +
|-
 +
| 2012-07-16
 +
| style="text-align: right;" | 5053
 +
| style="text-align: right;" | 5085
 +
| style="text-align: right;" | 33
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Perfs Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
| 2013-0
+
| 2012-01-26
| style="text-align:right;" | 15536.0
+
| H2O
|  
+
| style="text-align: right;" | 20
|
+
| style="text-align: right;" | 136093 Gal
|  
+
| style="text-align: right;" | 50000
| style="text-align:right;" | 723.0
+
| [[Universal Well Services Inc.]]
 
|  
 
|  
 
|-
 
|-
 +
| 2012-01-26
 +
| H2O
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 136093 Gal
 +
| style="text-align: right;" | 0
 +
| [[Universal Well Services Inc.]]
 +
| 500 sacks of sand
 +
No problems were encountered.
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblStimulation Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
| 2012
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 15805
 +
| style="text-align: right;" | 965
 +
| style="text-align: right;" | 296
 +
|-
 +
| 2013
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 15536
 +
| style="text-align: right;" | 723
 +
| style="text-align: right;" | 365
 +
|-
 +
| 2014
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 13280
 +
| style="text-align: right;" | 495
 +
| style="text-align: right;" | 360
 +
|-
 +
| 2015
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 10981
 +
| style="text-align: right;" | 288
 +
| style="text-align: right;" | 360
 +
|-
 +
| 2016
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 7754
 +
| style="text-align: right;" | 255
 +
| style="text-align: right;" | 359
 +
|-
 +
| 2017
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 6509
 +
| style="text-align: right;" | 249
 +
| style="text-align: right;" | 359
 +
|-
 +
| 2018
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 6341
 +
| style="text-align: right;" | 339
 +
| style="text-align: right;" | 359
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Production Table - Oil and Gas Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Oil and Gas Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
| 2012
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 104
 +
| style="text-align: right;" | 296
 +
|-
 +
| 2013
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 37
 +
| style="text-align: right;" | 365
 +
|-
 +
| 2014
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 14
 +
| style="text-align: right;" | 360
 +
|-
 +
| 2015
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 41
 +
| style="text-align: right;" | 360
 +
|-
 +
| 2016
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 359
 +
|-
 +
| 2017
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 359
 
|-
 
|-
| 2014-0
+
| 2018
| style="text-align:right;" | 13280.0
+
| [[PAC DRILLING LLC]]
| style="text-align:right;" | 360.0
+
| Brine
|  
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 359
| style="text-align:right;" | 495.0
 
| style="text-align:right;" | 360.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - Production Table - Brine Data
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
|publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date =  2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
  | date = 2019-05-07
 +
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
!scope="col" | VIOLATION CODE
+
|-
!scope="col" | VIOLATION COMMENT
+
| 0152402007
 +
| 2018-05-21
 +
| UrbanProduction Wells
 +
| Violations Noted
 +
| At the time of this inspection, the well was equipped with a plunger lift assembly.  The annulus and flow line valves were open.  A domestic gas supply was plumbed off of the wellhead with an open ball valve, a regulator, 3 inch drip tank and gas meter.  There was identification posted at the well.  No fencing was installed around the well, due to a pre-site waiver.  The diked tank battery has two storage tanks and a separator.  The 50 BBL poly tank had a leak at the hammer union on the dump line.  The leak needs repaired.  The pick-up lines have plugs and locks.  The 210 BBL tank was missing the required urban safety equipment and needs installed per 1501:9-9--e).  There was an identification sign posted at the tank battery.  The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e).  A locked chain link fence surrounds the tank battery.  The 210 BBL tank extends more than 3 foot above the fencing.  Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9--site inspection.  Install the required gate with a lock at the access road entrance per 1501:9-9--9-
 +
|-
 +
| 0186385100
 +
| 2019-02-04
 +
| UrbanProduction Wells
 +
| No Violations
 +
| I conducted a compliance notice follow-up inspection for compliance notice 152402007, requiring multiple compliance issues involving urban requirments.  At the time of this inspection, the  hammer union on the dump line of the 50 BBL poly tank has been repaired.  The 210 BBL tank was still missing the required urban safety equipment and needs installed per 1501:9-9-05E(4)(b-e).  There was an identification sign posted at the tank battery that has been amended with the required information per 1501:9-9-05(E)(1)(a-e).  A locked chain link fence surrounds the tank battery.  The 210 BBL tank extends more than 3 foot above the fencing.  Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05E(4)(f).  There was no landscaping around the tank battery, however the tank battery was located in a wooded area.  No gate has been installed at the entrance.  The gate was not waived during the pre-site inspection.  Install the required gate with a lock at the access road entrance per 1501:9-9-05E(2), and post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f).
 +
 
 +
PAC needs to:
 +
1) Install the required urban safety equipment on the 210 BBL production tank and needs installed per 1501:9-9-05E(4)(b-e).
 +
2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05E(4)(f).
 +
3) Install the landscaping around the tank battery.
 +
4)  Install the required gate with a lock at the access road entrance per 1501:9-9-05E(2), and post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f).
 +
|-
 +
| 0295248186
 +
| 2012-01-22
 +
| Urban Drill / Deepen /  Reopen
 +
| No Violations
 +
| The production casing was successfully cemented with 200 sacks of Unitropic cement.  The cement operation and site conditions were acceptable.
 +
|-
 +
| 0308464393
 +
| 2012-01-17
 +
| Urban Drill / Deepen /  Reopen
 +
| No Violations
 +
| The installation and cementing of surface casing was witnessed.  Cement operation and site conditions were acceptable.
 +
|-
 +
| 0722122340
 +
| 2015-09-04
 +
| Production Wells
 +
| No Violations
 +
| I was on location for a status check.  During my inspection, I found the well in production.  The well is equipped with plunger lift assembly.  The tank battery consists of a 210 barrel production tank, a 50 barrel, poly brine tank, and a vertical, mechanical separator.  There is dike around the tank battery.  An identification sign is posted.  There is no urban safety equipment on the production tank.  There are locked, chain link fences surrounding the well and tank battery.  The lease road is in stable condition.  I called and spoke with PAC Drilling.  I instructed PAC to immediately install the proper urban safety equipment on the production tank.  Follow-up inspections will be conducted.
 +
|-
 +
| 0756822428
 +
| 2012-02-02
 +
| Urban Drill / Deepen /  Reopen
 +
| No Violations
 +
| The contractor was mixing two truck loads of dust into the drilling pits.  All conditions were acceptable.
 
|-
 
|-
 
| 1330528435
 
| 1330528435
 
| 2012-01-10
 
| 2012-01-10
|  
+
| Urban Drill / Deepen /  Reopen
 +
| No Violations
 
| The well location was under construction and the blow pit had been excavated.  All conditions were acceptable.
 
| The well location was under construction and the blow pit had been excavated.  All conditions were acceptable.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1346865092
 
| 1346865092
 
| 2012-09-05
 
| 2012-09-05
|  
+
| UrbanPreliminary Restoration
 +
| No Violations
 
| I completed an Urban Preliminary Restoration inspection.  My inspection found the well surrounded by a chain link fence and equipped with a plunger lift unit (rabbit).  The tank battery was surrounded by a chain link fence and contained one 210 barrel storage tanks, one 50 barrel brine storage tank, the proper identification posted, and a separator.  The production equipment had the proper spacing, the pit were closed, and all the debris removed.  The site has been graded and seeded to prevent erosion and sedimentation.  Inspection passed.
 
| I completed an Urban Preliminary Restoration inspection.  My inspection found the well surrounded by a chain link fence and equipped with a plunger lift unit (rabbit).  The tank battery was surrounded by a chain link fence and contained one 210 barrel storage tanks, one 50 barrel brine storage tank, the proper identification posted, and a separator.  The production equipment had the proper spacing, the pit were closed, and all the debris removed.  The site has been graded and seeded to prevent erosion and sedimentation.  Inspection passed.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1393018518
 
| 1393018518
 
| 2012-01-17
 
| 2012-01-17
|  
+
| Urban Drill / Deepen /  Reopen
 +
| No Violations
 
| The blowout preventer held 400 PSI for 15 minutes without loss and passed test.
 
| The blowout preventer held 400 PSI for 15 minutes without loss and passed test.
|
 
|
 
|
 
 
|-
 
|-
 +
| 1734047941
 +
| 2017-03-13
 +
| UrbanProduction Wells
 +
| No Violations
 +
--up lines have plugs, but are missing locks.  The 210 bbl. storage tank is missing the required urban safety equipment.  There is an identification sign posted at the tank battery.  The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. 
 +
 +
PAC needs to:
 +
1)  Correct the identification sign to be in compliance with 1501:9-9--e) at the tank battery with:
 +
Well owners address and phone number
 +
Property street address or nearest address to the access road entrance.
 +
2)  Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-
 +
3)  Install the require gate with a lock at the access road entrance per 1501:9-9-
 +
4)  Post the proper identification sign on the access road gate per 1501:9-9-
 +
5)  Install locks on all pick-up lines or remove the handles per 1501:9-9-
 +
6)  Install urban safety equipment on the production tank as required by 1501:9-9--e):
 +
Activated charcoal filters.
 +
Functioning low-pressure relief valve.
 +
Tank hatch lids sh
 
|-
 
|-
| 295248186
+
|}
| 2012-01-22
+
==== Violations Commited ====
|  
+
{| class="wikitable sortable" width="95%"
| The production casing was successfully cemented with 200 sacks of Unitropic cement.  The cement operation and site conditions were acceptable.
+
!scope="col" style="text-align: center"| Inspection ID
|  
+
!scope="col" style="text-align: center"| Violation ID
|  
+
!scope="col" style="text-align: center"| Violation Date
|  
+
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 
|-
 
|-
 +
| 0152402007
 +
| US-OH-114546
 +
| 2018-05-25
 +
| 9-05E1
 +
| ID (a-i)
 
|-
 
|-
| 308464393
+
| 0152402007
| 2012-01-17
+
| US-OH-114547
|
+
| 2018-05-25
| The installation and cementing of surface casing was witnessed.  Cement operation and site conditions were acceptable.
+
| 9-05E2
|  
+
| FENCING (a-d)
|  
 
|  
 
 
|-
 
|-
 +
| 0152402007
 +
| US-OH-114548
 +
| 2018-05-25
 +
| 9-05E4
 +
| TANKS (a-i)
 
|-
 
|-
| -756822428
+
| 0152402007
| 2012-02-02
+
| US-OH-114549
|  
+
| 2018-05-25
| The contractor was mixing two truck loads of dust into the drilling pits.  All conditions were acceptable.
+
| 9-9-05(A)9
|
+
| No SPCC dike/or failure to keep dike free of water or oil
|
 
|
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 18:56, 24 July 2019

Well Details

Well ID: 34-155-24052
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: FILICKY
License Status: Producing
License Date: 2012-07-16
Spud Date: 2012-01-16
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2012-01-21
Well Total Depth: 5354 ft
Configuration: Vertical
Latitude: 41.153517280
Longitude: -80.61354578

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-01-05 Proposed Formations:CLINTON/MEDINA, Issued Date:1/5/2012, Expired Date:1/4/2014 12:00:00 PM, Drilling unit acres:41.45, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2012-01-21
Completion Report Received 2012-06-21
Construction Permit Expires 2013-01-04
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-07-16 5026 5030 5
2012-07-16 5042 5044 3
2012-07-16 5053 5085 33

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-01-26 H2O 20 136093 Gal 50000 Universal Well Services Inc.
2012-01-26 H2O 20 136093 Gal 0 Universal Well Services Inc. 500 sacks of sand

No problems were encountered.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 PAC DRILLING LLC 15805 965 296
2013 PAC DRILLING LLC 15536 723 365
2014 PAC DRILLING LLC 13280 495 360
2015 PAC DRILLING LLC 10981 288 360
2016 PAC DRILLING LLC 7754 255 359
2017 PAC DRILLING LLC 6509 249 359
2018 PAC DRILLING LLC 6341 339 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 PAC DRILLING LLC Brine 104 296
2013 PAC DRILLING LLC Brine 37 365
2014 PAC DRILLING LLC Brine 14 360
2015 PAC DRILLING LLC Brine 41 360
2016 PAC DRILLING LLC Brine 0 359
2017 PAC DRILLING LLC Brine 0 359
2018 PAC DRILLING LLC Brine 0 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0152402007 2018-05-21 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. A domestic gas supply was plumbed off of the wellhead with an open ball valve, a regulator, 3 inch drip tank and gas meter. There was identification posted at the well. No fencing was installed around the well, due to a pre-site waiver. The diked tank battery has two storage tanks and a separator. The 50 BBL poly tank had a leak at the hammer union on the dump line. The leak needs repaired. The pick-up lines have plugs and locks. The 210 BBL tank was missing the required urban safety equipment and needs installed per 1501:9-9--e). There was an identification sign posted at the tank battery. The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e). A locked chain link fence surrounds the tank battery. The 210 BBL tank extends more than 3 foot above the fencing. Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9--site inspection. Install the required gate with a lock at the access road entrance per 1501:9-9--9-
0186385100 2019-02-04 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 152402007, requiring multiple compliance issues involving urban requirments. At the time of this inspection, the hammer union on the dump line of the 50 BBL poly tank has been repaired. The 210 BBL tank was still missing the required urban safety equipment and needs installed per 1501:9-9-05E(4)(b-e). There was an identification sign posted at the tank battery that has been amended with the required information per 1501:9-9-05(E)(1)(a-e). A locked chain link fence surrounds the tank battery. The 210 BBL tank extends more than 3 foot above the fencing. Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05E(4)(f). There was no landscaping around the tank battery, however the tank battery was located in a wooded area. No gate has been installed at the entrance. The gate was not waived during the pre-site inspection. Install the required gate with a lock at the access road entrance per 1501:9-9-05E(2), and post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f).

PAC needs to: 1) Install the required urban safety equipment on the 210 BBL production tank and needs installed per 1501:9-9-05E(4)(b-e). 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05E(4)(f). 3) Install the landscaping around the tank battery. 4) Install the required gate with a lock at the access road entrance per 1501:9-9-05E(2), and post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f).

0295248186 2012-01-22 Urban Drill / Deepen / Reopen No Violations The production casing was successfully cemented with 200 sacks of Unitropic cement. The cement operation and site conditions were acceptable.
0308464393 2012-01-17 Urban Drill / Deepen / Reopen No Violations The installation and cementing of surface casing was witnessed. Cement operation and site conditions were acceptable.
0722122340 2015-09-04 Production Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with plunger lift assembly. The tank battery consists of a 210 barrel production tank, a 50 barrel, poly brine tank, and a vertical, mechanical separator. There is dike around the tank battery. An identification sign is posted. There is no urban safety equipment on the production tank. There are locked, chain link fences surrounding the well and tank battery. The lease road is in stable condition. I called and spoke with PAC Drilling. I instructed PAC to immediately install the proper urban safety equipment on the production tank. Follow-up inspections will be conducted.
0756822428 2012-02-02 Urban Drill / Deepen / Reopen No Violations The contractor was mixing two truck loads of dust into the drilling pits. All conditions were acceptable.
1330528435 2012-01-10 Urban Drill / Deepen / Reopen No Violations The well location was under construction and the blow pit had been excavated. All conditions were acceptable.
1346865092 2012-09-05 UrbanPreliminary Restoration No Violations I completed an Urban Preliminary Restoration inspection. My inspection found the well surrounded by a chain link fence and equipped with a plunger lift unit (rabbit). The tank battery was surrounded by a chain link fence and contained one 210 barrel storage tanks, one 50 barrel brine storage tank, the proper identification posted, and a separator. The production equipment had the proper spacing, the pit were closed, and all the debris removed. The site has been graded and seeded to prevent erosion and sedimentation. Inspection passed.
1393018518 2012-01-17 Urban Drill / Deepen / Reopen No Violations The blowout preventer held 400 PSI for 15 minutes without loss and passed test.
1734047941 2017-03-13 UrbanProduction Wells No Violations

--up lines have plugs, but are missing locks. The 210 bbl. storage tank is missing the required urban safety equipment. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9- 3) Install the require gate with a lock at the access road entrance per 1501:9-9- 4) Post the proper identification sign on the access road gate per 1501:9-9- 5) Install locks on all pick-up lines or remove the handles per 1501:9-9- 6) Install urban safety equipment on the production tank as required by 1501:9-9--e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids sh

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0152402007 US-OH-114546 2018-05-25 9-05E1 ID (a-i)
0152402007 US-OH-114547 2018-05-25 9-05E2 FENCING (a-d)
0152402007 US-OH-114548 2018-05-25 9-05E4 TANKS (a-i)
0152402007 US-OH-114549 2018-05-25 9-9-05(A)9 No SPCC dike/or failure to keep dike free of water or oil