If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-081-20518 | | Well ID: 37-081-20518 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.409381, -76.933306 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Regulatory Inactive Status | | License Status: Regulatory Inactive Status | ||
|- | |- | ||
− | | Spud Date: 03 | + | | Spud Date: 2011-03-01 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2011-02-07 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2011-07-29 | ||
+ | | 2011-07-29 | ||
+ | | style="text-align: right;" | 7331.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="19"| 1 | ||
+ | | rowspan="1"| Poly CFR40G 1020 | ||
+ | | rowspan="1"| Frac Tech Services (FTS) | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Cationic water-soluble polymer emulsion | ||
+ | | | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 0.08 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="5"| CI-150 (Corrosion Inhibitor) | ||
+ | | rowspan="5"| Frac Tech Services (FTS) | ||
+ | | rowspan="5"| Corrosion Inhibitor | ||
+ | | N,N-Dimethylformamide | ||
+ | | 68-12-2 | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00010000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Isopropanol | ||
+ | | 67-63-0 | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.00057000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Aromatic Aldehyde | ||
+ | | | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00010000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Quaternary Ammonium Compound | ||
+ | | | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00010000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Organic Amineresin Salt | ||
+ | | | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00029000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FE 100L (Iron Chelator) | ||
+ | | rowspan="1"| Frac Tech Services (FTS) | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Citric acid | ||
+ | | 77-92-9 | ||
+ | | style="text-align: right;" | 55.00 | ||
+ | | style="text-align: right;" | 0.00153000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Sand (Proppant) | ||
+ | | rowspan="2"| Frac Tech Services (FTS) | ||
+ | | rowspan="2"| Proppant | ||
+ | | | ||
+ | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 99.90 | ||
+ | | style="text-align: right;" | 11.25 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="5"| Poly CS-39 | ||
+ | | rowspan="5"| Frac Tech Services (FTS) | ||
+ | | rowspan="5"| Clay Stabilizer | ||
+ | | Chloride | ||
+ | | 16887-00-6 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.05 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Proprietary poly electrolyte | ||
+ | | | ||
+ | | style="text-align: right;" | 40.00 | ||
+ | | style="text-align: right;" | 0.06 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.10 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | | ||
+ | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Proprietary inorganic chemical | ||
+ | | | ||
+ | | style="text-align: right;" | 20.00 | ||
+ | | style="text-align: right;" | 0.03 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| ICI-3240 | ||
+ | | rowspan="2"| Frac Tech Services (FTS) | ||
+ | | rowspan="2"| Biocide | ||
+ | | Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione | ||
+ | | 533-74-4 | ||
+ | | style="text-align: right;" | 24.00 | ||
+ | | style="text-align: right;" | 0.00557000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Sodium hydroxide | ||
+ | | 1310-73-2 | ||
+ | | style="text-align: right;" | 4.00 | ||
+ | | style="text-align: right;" | 0.00093000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Acid, Hydrochloric (7.5) | ||
+ | | rowspan="1"| Frac Tech Services (FTS) | ||
+ | | rowspan="1"| Solvent | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 7.50 | ||
+ | | style="text-align: right;" | 0.04 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Anadarko | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 87.89 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| CS-500 SI | ||
+ | | rowspan="1"| Frac Tech Services (FTS) | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00137000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 181: | Line 368: | ||
| 1975767 | | 1975767 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2011-05-25 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 188: | Line 375: | ||
| 2018140 | | 2018140 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2011-11-08 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 195: | Line 382: | ||
| 2062858 | | 2062858 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2012-04-25 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 202: | Line 389: | ||
| 2198915 | | 2198915 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2013-08-26 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 209: | Line 396: | ||
| 2206918 | | 2206918 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-24 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 216: | Line 403: | ||
| 2236983 | | 2236983 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-14 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| No Violations Noted | | No Violations Noted | ||
Line 281: | Line 468: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-081-20518 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.409381,"lon":-76.933306,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Gamble Township | |
Operator Name: ARD OPR LLC | |
Well Pad ID: 147969 | |
Farm/Lease Name: CLEARVIEW HUNTING CLUB A 4H | |
License Status: Regulatory Inactive Status | |
Spud Date: 2011-03-01 | |
Permit Date: 2011-02-07 | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Latitude: 41.409381 | |
Longitude: -76.933306 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-07-29 | 2011-07-29 | 7331.00 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Poly CFR40G 1020 | Frac Tech Services (FTS) | Friction Reducer | Cationic water-soluble polymer emulsion | 100.00 | 0.08 | ||
CI-150 (Corrosion Inhibitor) | Frac Tech Services (FTS) | Corrosion Inhibitor | N,N-Dimethylformamide | 68-12-2 | 10.00 | 0.00010000 | ||
Isopropanol | 67-63-0 | 60.00 | 0.00057000 | |||||
Aromatic Aldehyde | 10.00 | 0.00010000 | ||||||
Quaternary Ammonium Compound | 10.00 | 0.00010000 | ||||||
Organic Amineresin Salt | 30.00 | 0.00029000 | ||||||
FE 100L (Iron Chelator) | Frac Tech Services (FTS) | Iron Control | Citric acid | 77-92-9 | 55.00 | 0.00153000 | ||
Sand (Proppant) | Frac Tech Services (FTS) | Proppant | ||||||
Quartz | 14808-60-7 | 99.90 | 11.25 | |||||
Poly CS-39 | Frac Tech Services (FTS) | Clay Stabilizer | Chloride | 16887-00-6 | 30.00 | 0.05 | ||
Proprietary poly electrolyte | 40.00 | 0.06 | ||||||
Water | 7732-18-5 | 60.00 | 0.10 | |||||
Proprietary inorganic chemical | 20.00 | 0.03 | ||||||
ICI-3240 | Frac Tech Services (FTS) | Biocide | Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione | 533-74-4 | 24.00 | 0.00557000 | ||
Sodium hydroxide | 1310-73-2 | 4.00 | 0.00093000 | |||||
Acid, Hydrochloric (7.5) | Frac Tech Services (FTS) | Solvent | Hydrochloric acid | 7647-01-0 | 7.50 | 0.04 | ||
Water | Anadarko | Carrier/Base Fluid | Water | 7732-18-5 | 100.00 | 87.89 | ||
CS-500 SI | Frac Tech Services (FTS) | Scale Inhibitor | Ethylene glycol | 107-21-1 | 10.00 | 0.00137000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | ARD OPR LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-S01 | Drill Cuttings (in Tons) | 888.82 Tons | LANDFILL | 100955 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1975767 | Primary Facility | 2011-05-25 | Drilling/Alteration | No Violations Noted | |
2018140 | Primary Facility | 2011-11-08 | Routine/Complete Inspection | No Violations Noted | |
2062858 | Primary Facility | 2012-04-25 | Routine/Complete Inspection | No Violations Noted | |
2198915 | Primary Facility | 2013-08-26 | Routine/Complete Inspection | No Violations Noted | |
2206918 | Primary Facility | 2013-09-24 | Routine/Complete Inspection | No Violations Noted | |
2236983 | Primary Facility | 2014-01-14 | Incident- Response to Accident or Event | No Violations Noted | Violations pending for 081-20517 (6H) well. produced water spill to the pad. |
2465513 | Primary Facility | 2016-03-16 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection, three wells were in production while the fourth (081-20518) was granted inactive status on 10/29/2013. The well site is currently well vegetated and shows no signs of erosion. The well site remains at the originally constructed size and has not been restored as indicated in the permitted plans. The requirement under Section 3216 (c) of the Oil and Gas Act requires that "within nine months after completion of drilling of a well, the owner or operator shall restore the well site."
The approved plans call for a portion of the well site to be scarified and production facilities are installed where the site is to be scarified. I recommend re-permitting the site to incorporate a feasible restoration of the site. No Violations Noted |
2524917 | Primary Facility | 2016-10-03 | Routine/Complete Inspection | No Violations Noted | Remarks Arrived @ 14:30. Weather: windy and cloudy. There were 3 producing wells and 1 plugged well in a linear array on location. Lease operator Kevin Barr and automation tech Matt Musgrave were onsite when I arrived. Water injection and plunger systems were in use on the three production wells to limit salt build-up. The water injection plumbing was covered in silver insulation material, gas and water were plumbed to the GPUs.
A-4H plugged, 1 annulus shut-in. Candy cane vent was monitored for combustible gas. No combustible gas was detected (Altair 5X gas meter, calibrated 10/3/16 |
2698669 | Primary Facility | 2018-02-27 | Routine/Complete Inspection | No Violations Noted | Weather was 38° and sunny at time of inspection. Well is plugged with a candycane style vent and a well tag attached with the correct API number listed on it. There was 0% combustible gas detected on the vent or anywhere around the well at time of inspection. No violations were noted at time of inspection. |
2854736 | Primary Facility | 2019-03-18 | Routine/Complete Inspection | No Violations Noted | Weather fair @ 39°F. Four wells on location and three wells staged for production. Well 081-20518 is granted regulatory inactive status. Three GPUs within polyurethane/foam containment. No leaks detected. No violations noted. |
For data sources see[7]