X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20518

Well Details

Well ID: 37-081-20518
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Gamble Township
Operator Name: ARD OPR LLC
Well Pad ID: 147969
Farm/Lease Name: CLEARVIEW HUNTING CLUB
License Status: INACTIVE
Spud Date:
Permit Date: 2011-02-07
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.409381
Longitude: -76.933306

For data sources see[1][2][3]

Well History

Date Event
2011-02-07 New Permit Application
2011-03-01 Performed Spud Operation
2011-06-28 Drilling Completion
2011-07-19 Perforation
2012-03-08 DEVIATED
2015-02-10 PARTIALLY PLUGGED
2019-07-01 Inactive Well Request Granted

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-29 2011-07-29 7,331

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Poly CFR40G 1020 Frac Tech Services (FTS) Friction Reducer Cationic water-soluble polymer emulsion 100.00 0.08
CI-150 (Corrosion Inhibitor) Frac Tech Services (FTS) Corrosion Inhibitor N,N-Dimethylformamide 68-12-2 10.00 0.00010000
Isopropanol 67-63-0 60.00 0.00057000
Aromatic Aldehyde 10.00 0.00010000
Quaternary Ammonium Compound 10.00 0.00010000
Organic Amineresin Salt 30.00 0.00029000
FE 100L (Iron Chelator) Frac Tech Services (FTS) Iron Control Citric acid 77-92-9 55.00 0.00153000
Sand (Proppant) Frac Tech Services (FTS) Proppant
Quartz 14808-60-7 99.90 11.25
Poly CS-39 Frac Tech Services (FTS) Clay Stabilizer Chloride 16887-00-6 30.00 0.05
Proprietary poly electrolyte 40.00 0.06
Water 7732-18-5 60.00 0.10
Proprietary inorganic chemical 20.00 0.03
ICI-3240 Frac Tech Services (FTS) Biocide Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione 533-74-4 24.00 0.00557000
Sodium hydroxide 1310-73-2 4.00 0.00093000
Acid, Hydrochloric (7.5) Frac Tech Services (FTS) Solvent Hydrochloric acid 7647-01-0 7.50 0.04
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100.00 87.89
CS-500 SI Frac Tech Services (FTS) Scale Inhibitor Ethylene glycol 107-21-1 10.00 0.00137000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2011 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2017 ARD OPR LLC 0.00 0 0.00 0 0.00 0
2019 ARD OPR LLC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 ANADARKO E&P ONSHORE LLC Drill Cuttings 888.82 Tons LANDFILL 100955

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1975767 Primary Facility 2011-05-25 Drilling/Alteration No Violations Noted
2018140 Primary Facility 2011-11-08 Routine/Complete Inspection No Violations Noted
2062858 Primary Facility 2012-04-25 Routine/Complete Inspection No Violations Noted
2198915 Primary Facility 2013-08-26 Routine/Complete Inspection No Violations Noted
2206918 Primary Facility 2013-09-24 Routine/Complete Inspection No Violations Noted
2236983 Primary Facility 2014-01-14 Incident- Response to Accident or Event No Violations Noted Violations pending for 081-20517 (6H) well. produced water spill to the pad.
2465513 Primary Facility 2016-03-16 Routine/Complete Inspection No Violations Noted At the time of the inspection, three wells were in production while the fourth (081-20518) was granted inactive status on 10/29/2013. The well site is currently well vegetated and shows no signs of erosion. The well site remains at the originally constructed size and has not been restored as indicated in the permitted plans. The requirement under Section 3216 (c) of the Oil and Gas Act requires that "within nine months after completion of drilling of a well, the owner or operator shall restore the well site."

The approved plans call for a portion of the well site to be scarified and production facilities are installed where the site is to be scarified. I recommend re-permitting the site to incorporate a feasible restoration of the site. No Violations Noted

2524917 Primary Facility 2016-10-03 Routine/Complete Inspection No Violations Noted Remarks Arrived @ 14:30. Weather: windy and cloudy. There were 3 producing wells and 1 plugged well in a linear array on location. Lease operator Kevin Barr and automation tech Matt Musgrave were onsite when I arrived. Water injection and plunger systems were in use on the three production wells to limit salt build-up. The water injection plumbing was covered in silver insulation material, gas and water were plumbed to the GPUs.

A-4H plugged, 1 annulus shut-in. Candy cane vent was monitored for combustible gas. No combustible gas was detected (Altair 5X gas meter, calibrated 10/3/16

2698669 Primary Facility 2018-02-27 Routine/Complete Inspection No Violations Noted Weather was 38° and sunny at time of inspection. Well is plugged with a candycane style vent and a well tag attached with the correct API number listed on it. There was 0% combustible gas detected on the vent or anywhere around the well at time of inspection. No violations were noted at time of inspection.
2854736 Primary Facility 2019-03-18 Routine/Complete Inspection No Violations Noted Weather fair @ 39°F. Four wells on location and three wells staged for production. Well 081-20518 is granted regulatory inactive status. Three GPUs within polyurethane/foam containment. No leaks detected. No violations noted.

For data sources see[8]