34-167-28142

Well Details

Well ID: 34-167-28142
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Adams Township
Operator Name: ENERGY CONTRACTORS INC
Well Pad ID:
Farm/Lease Name: GRIFFEN LAURA A
License Status: Plugged and Abandoned
License Date: 2017-07-19
Spud Date: 1985-06-15
Spud Drilling Contractor: CT DRILLING
Final Drill Date: 1985-06-21
Well Total Depth: 6113.00 ft
Configuration: Vertical
Latitude: 39.550000
Longitude: -81.520000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1985-05-14 122 TIGER OIL INC GeoDate 5/14/85
Oil and Gas 1985-05-14 Issued Date 5/14/85 Expired Date 11/10/85 Acres 0050000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 06113 Proposed Drill Depth 06113
Original Spud 1985-06-15 CHG FTG 8-24-85
Completed 1985-06-21 CHG FTG 8-24-85
Reached Total Depth 1985-06-21 CHG FTG 8-24-85
Completion Report Received 1985-09-18 CHG FTG 8-24-85
CO 1994-02-25 2070 HALWELL COMPANY GeoDate 5/14/85
Change of Owner 2000-12-27 Operator changed from 2070, HALWELL COMPANY to 2680, ENERGY CONTRACTORS INC
Change of Owner 2000-12-27 Operator changed from 2680, ENERGY CONTRACTORS INC to 4540, PEOPLES PETROLEUM CORP.
APP 2001-04-18 Proposed Formations:CLINTON, Issued Date:4/18/2001, Expired Date:4/18/2002 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:HAD, Proposed Well Class:
APP 2005-10-25 Proposed Formations:CLINTON, Issued Date:10/25/2005, Expired Date:10/25/2006 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:HAD, Proposed Well Class:
Change of Owner 2006-04-07 Operator changed from 4540, PEOPLES PETROLEUM CORP. to 2680, ENERGY CONTRACTORS INC
APP 2006-06-12 Proposed Formations:GORDON-THIRTY FOOT, Issued Date:6/12/2006, Expired Date:6/12/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:HAD, Proposed Well Class:
APP 2008-04-24 Proposed Formations:CLINTON, Issued Date:4/24/2008, Expired Date:4/24/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:HAD, Proposed Well Class:
APP 2017-07-19 Proposed Formations:CLINTON, Issued Date:7/19/2017, Expired Date:7/19/2019 12:00:00 PM, Drilling unit acres:50, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-11-20 CHG FTG 8-24-85
Record Last Modified 2018-11-05 CHG FTG 8-24-85
Construction Permit Expires 2019-07-19 CHG FTG 8-24-85

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5991 6028 15
5991 6028 15
5991 6028 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 0
H2O 0 500 Bbl 0
ACID 0 500 Gal 30000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 TIGER OIL INC 3921.00 0.00 145
1986 TIGER OIL INC 14145.00 0.00 365
1987 TIGER OIL INC 2907.00 0.00 365
1993 TIGER OIL INC 0.00 0.00 0
1994 TIGER OIL INC 360.00 0.00 365
1995 ENERGY CONTRACTORS INC 0.00 0.00 365
1996 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
1997 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
1998 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2000 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2001 PEOPLES PETROLEUM CORP. 0.00 0.00 0
2002 PEOPLES PETROLEUM CORP. 0.00 0.00 0
2003 PEOPLES PETROLEUM CORP. 0.00 0.00 0
2004 PEOPLES PETROLEUM CORP. 0.00 0.00 0
2008 NORTHWOOD ENERGY CORP 0.00 0.00 0
2009 NORTHWOOD ENERGY CORP 0.00 0.00 0
2010 NORTHWOOD ENERGY CORP 0.00 0.00 0
2016 ENERGY CONTRACTORS INC 0.00 0.00 0
2017 ENERGY CONTRACTORS INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 TIGER OIL INC Brine 0 145
1986 TIGER OIL INC Brine 0 365
1987 TIGER OIL INC Brine 0 365
1993 TIGER OIL INC Brine 0 0
1994 TIGER OIL INC Brine 0 365
1995 ENERGY CONTRACTORS INC Brine 0 365
1996 STONEBRIDGE OPERATING CO LLC Brine 0 0
1997 STONEBRIDGE OPERATING CO LLC Brine 0 0
1998 ENERGY CONTRACTORS INC Brine 0 365
2000 STONEBRIDGE OPERATING CO LLC Brine 0 0
2001 PEOPLES PETROLEUM CORP. Brine 0 0
2002 PEOPLES PETROLEUM CORP. Brine 0 0
2003 PEOPLES PETROLEUM CORP. Brine 0 0
2004 PEOPLES PETROLEUM CORP. Brine 0 0
2008 NORTHWOOD ENERGY CORP Brine 0 0
2009 NORTHWOOD ENERGY CORP Brine 72 0
2010 NORTHWOOD ENERGY CORP Brine 0 0
2016 ENERGY CONTRACTORS INC Brine 0 0
2017 ENERGY CONTRACTORS INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1255546588 2008-3-12 0:00: PW No Violations
-1473621454 2015-1-16 0:00: PW No Violations 1.50
-191011890 2017-11-17 0:00 PB No Violations 2.70
-1960768901 2014-6-10 0:00: PW No Violations 1.00
-2033544190 2014-3-31 0:00: PW No Violations 2.00
-26020942 2017-7-5 0:00:0 PW No Violations 1.00
0000PL1533 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0026020942 2017-07-05 Production Wells No Violations The inspection this day revealed that this well is equipped with a 8 5/8 inch diameter surface casing, 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. The valves on the wellhead are closed at the time of inspection. The tank battery is equipped with a 100 barrel steel tank and a horizontal separator. There has been no resolution to the issues on this well and the well is idle at the time of inspection.
0191011890 2017-11-17 Plug / Plug Back No Violations I went to cover a plug job for inspector Sefcik. Upon arrival they pulled the 4.5 inch out to see what they were dealing with. They pulled out 3 range 4 joints, about 130. The pipe pulled apart in the 4.5 at a collar and a very rusty and scaly thread was on bottom. This would indicate that the pipe has been unscrewed for a very long time. They decided the first thing they would try would be to use a steel nipple and try to screw back into the collar that is there. We then decided that if that was successful they would perforate the 4.5 in the lime and set the lime plug. Then cut the pipe above the tight spot approximately 2300-2400 feet, then pump a rip plug. Then plug the rest of the way out.
0441550199 2016-06-14 Production Wells No Violations The purpose of my inspection today is a compliance notice follow up. The well is equipped with 8.625 inch surface casing, 4.5 inch production casing, and 1.5 inch tubing. The well is idle. The production equipment consists of one horizontal separator and one 100 bbl. tank. The 100 bbl. tank is leaking oil and there is a contaminated spot on the ground beside the tank that is 6 ft. by 3 ft. The well and production equipment is overgrown with vegetation. No changes to the well have been made since the inspection by ODNR Inspector Lynn Parkins on 1/16/15. Pictures were taken of the well and the production equipment to assist this inspection.
1136211834 2020-6-10 0:00: FR No Violations 0.50
1255546588 2008-03-12 Production Wells Violations Noted Inspection this day found casing well with valves shut. Tank has very poor IDs that barely say Tiger Oil and permit no., good dike, no meter, meter housing open. No one has been to this well for long time, dont see how landowner could be using gas.
1473621454 2015-01-16 Production Wells No Violations Upon inspection, it was observed that no effort has been made to bring this well into compliance since my last inspection on 6/10/2014. I spoke with a representative from Energy Contractors/Tiger Oil and he stated that they sold this well to Northwood a few years ago. I explained to him that the well still shows on their bond and they are responsible for it. He stated that he would contact Northwood Energy and ask why the bond transfer was never completed and also stated that Energy Contractors would plug the well if necessary.
1474212508 2020-6-30 0:00: PW No Violations 0.80
1534350406 2018-08-15 Plug / Plug Back No Violations The well has been plugged. The violation has been resolved. The inspector did not file a plug report as required and he is no longer employed by the Division.
1800655951 2008-03-12 Production Wells No Violations FOLLOW UP TO NOV # -1255546588 Inspection this day found casing well with valves shut. Tank has very poor IDs that barely say Tiger Oil and permit no., good dike, no meter, meter housing open. No one has been to this well for long time, dont see how landowner could be using gas.
1960768901 2014-06-10 Production Wells No Violations There has been no change at this well location since the last inspection by Inspector Andy Thomas on 3/31/14. I called Energy Contractors Inc. and they answered the phone as Tiger Oil, which is the operator name listed on the tank battery. I left the secretary my phone number and she said the owner would contact me as soon as possible to discuss plans for this well.
1966134910 2017-08-14 Production Wells No Violations The inspection this day revealed that this well is equipped with a 8 5/8 inch diameter surface casing, 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. The valves on the wellhead are closed at the time of inspection and there are no lines connected to the wellhead. The tank battery for this well consists of a 100 barrel steel tank and a horizontal separator. There are two tanks near the wellhead but only one of the tanks has the matching permit number for this well. There has been no resolution to the issues on this well and the well is idle and has no identification at the time of inspection.
2033544190 2014-03-31 Production Wells No Violations Well is not equipped for production. It has a 4.5 in. well head with 1.5 in. tubing in it. There is a valve with a swage and a tee on it. The valve is closed and there is no plug in the tee. The valves on the annular connections. There are no production lines connected to the well. The 100 barrel tank on the site is leaking. It has contaminated an area 2.5 ft. by 3 ft. I called the phone number supplied by RBDMS and left a message explaining what I saw and for them to call me.
2039004298 2017-06-29 Production Wells No Violations The inspection this day revealed that this well is equipped with 8 5/8 inch diameter surface casing and 4 1/2 inch diameter production tubing. The valves are closed on the wellhead at the time of inspection. There are no lines attached to the wellhead and no plugs are in place where the lines should be. The tank battery is equipped with two (2) 100 barrel steel tanks with no identification and a horizontal separator that has been overgrown with brush. There has been no resolution to the issues on this well and the well is idle at the time of inspection.
441550199 2016-6-14 0:00: PW No Violations 3.00
PL1533 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1255546588 US-OH-106884 2008-03-20 Failure to legibly identify well
1255546588 US-OH-106885 2008-03-20 Well shall be plugged

For data sources see[9]

References