If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-167-28142 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.55,"lon":-81.52,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Adams Township | |
Operator Name: ENERGY CONTRACTORS INC | |
Well Pad ID: | |
Farm/Lease Name: GRIFFEN LAURA A | |
License Status: Plugged and Abandoned | |
License Date: 2017-07-19 | |
Spud Date: 1985-06-15 | |
Spud Drilling Contractor: CT DRILLING | |
Final Drill Date: 1985-06-21 | |
Well Total Depth: 6113.00 ft | |
Configuration: Vertical | |
Latitude: 39.550000 | |
Longitude: -81.520000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1985-05-14 | 122 TIGER OIL INC GeoDate 5/14/85 |
Oil and Gas | 1985-05-14 | Issued Date 5/14/85 Expired Date 11/10/85 Acres 0050000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 06113 Proposed Drill Depth 06113 |
Original Spud | 1985-06-15 | CHG FTG 8-24-85 |
Completed | 1985-06-21 | CHG FTG 8-24-85 |
Reached Total Depth | 1985-06-21 | CHG FTG 8-24-85 |
Completion Report Received | 1985-09-18 | CHG FTG 8-24-85 |
CO | 1994-02-25 | 2070 HALWELL COMPANY GeoDate 5/14/85 |
Change of Owner | 2000-12-27 | Operator changed from 2070, HALWELL COMPANY to 2680, ENERGY CONTRACTORS INC |
Change of Owner | 2000-12-27 | Operator changed from 2680, ENERGY CONTRACTORS INC to 4540, PEOPLES PETROLEUM CORP. |
APP | 2001-04-18 | Proposed Formations:CLINTON, Issued Date:4/18/2001, Expired Date:4/18/2002 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:HAD, Proposed Well Class: |
APP | 2005-10-25 | Proposed Formations:CLINTON, Issued Date:10/25/2005, Expired Date:10/25/2006 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:HAD, Proposed Well Class: |
Change of Owner | 2006-04-07 | Operator changed from 4540, PEOPLES PETROLEUM CORP. to 2680, ENERGY CONTRACTORS INC |
APP | 2006-06-12 | Proposed Formations:GORDON-THIRTY FOOT, Issued Date:6/12/2006, Expired Date:6/12/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:HAD, Proposed Well Class: |
APP | 2008-04-24 | Proposed Formations:CLINTON, Issued Date:4/24/2008, Expired Date:4/24/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:HAD, Proposed Well Class: |
APP | 2017-07-19 | Proposed Formations:CLINTON, Issued Date:7/19/2017, Expired Date:7/19/2019 12:00:00 PM, Drilling unit acres:50, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2017-11-20 | CHG FTG 8-24-85 |
Record Last Modified | 2018-11-05 | CHG FTG 8-24-85 |
Construction Permit Expires | 2019-07-19 | CHG FTG 8-24-85 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5991 | 6028 | 15 |
5991 | 6028 | 15 | |
5991 | 6028 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1200 Bbl | 0 | |||
H2O | 0 | 500 Bbl | 0 | |||
ACID | 0 | 500 Gal | 30000 | FRAC;H2O,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | TIGER OIL INC | 3921.00 | 0.00 | 145 |
1986 | TIGER OIL INC | 14145.00 | 0.00 | 365 |
1987 | TIGER OIL INC | 2907.00 | 0.00 | 365 |
1993 | TIGER OIL INC | 0.00 | 0.00 | 0 |
1994 | TIGER OIL INC | 360.00 | 0.00 | 365 |
1995 | ENERGY CONTRACTORS INC | 0.00 | 0.00 | 365 |
1996 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
1997 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
1998 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2000 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2001 | PEOPLES PETROLEUM CORP. | 0.00 | 0.00 | 0 |
2002 | PEOPLES PETROLEUM CORP. | 0.00 | 0.00 | 0 |
2003 | PEOPLES PETROLEUM CORP. | 0.00 | 0.00 | 0 |
2004 | PEOPLES PETROLEUM CORP. | 0.00 | 0.00 | 0 |
2008 | NORTHWOOD ENERGY CORP | 0.00 | 0.00 | 0 |
2009 | NORTHWOOD ENERGY CORP | 0.00 | 0.00 | 0 |
2010 | NORTHWOOD ENERGY CORP | 0.00 | 0.00 | 0 |
2016 | ENERGY CONTRACTORS INC | 0.00 | 0.00 | 0 |
2017 | ENERGY CONTRACTORS INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | TIGER OIL INC | Brine | 0 | 145 |
1986 | TIGER OIL INC | Brine | 0 | 365 |
1987 | TIGER OIL INC | Brine | 0 | 365 |
1993 | TIGER OIL INC | Brine | 0 | 0 |
1994 | TIGER OIL INC | Brine | 0 | 365 |
1995 | ENERGY CONTRACTORS INC | Brine | 0 | 365 |
1996 | STONEBRIDGE OPERATING CO LLC | Brine | 0 | 0 |
1997 | STONEBRIDGE OPERATING CO LLC | Brine | 0 | 0 |
1998 | ENERGY CONTRACTORS INC | Brine | 0 | 365 |
2000 | STONEBRIDGE OPERATING CO LLC | Brine | 0 | 0 |
2001 | PEOPLES PETROLEUM CORP. | Brine | 0 | 0 |
2002 | PEOPLES PETROLEUM CORP. | Brine | 0 | 0 |
2003 | PEOPLES PETROLEUM CORP. | Brine | 0 | 0 |
2004 | PEOPLES PETROLEUM CORP. | Brine | 0 | 0 |
2008 | NORTHWOOD ENERGY CORP | Brine | 0 | 0 |
2009 | NORTHWOOD ENERGY CORP | Brine | 72 | 0 |
2010 | NORTHWOOD ENERGY CORP | Brine | 0 | 0 |
2016 | ENERGY CONTRACTORS INC | Brine | 0 | 0 |
2017 | ENERGY CONTRACTORS INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1255546588 | 2008-3-12 0:00: | PW | No Violations | |
-1473621454 | 2015-1-16 0:00: | PW | No Violations | 1.50 |
-191011890 | 2017-11-17 0:00 | PB | No Violations | 2.70 |
-1960768901 | 2014-6-10 0:00: | PW | No Violations | 1.00 |
-2033544190 | 2014-3-31 0:00: | PW | No Violations | 2.00 |
-26020942 | 2017-7-5 0:00:0 | PW | No Violations | 1.00 |
0000PL1533 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0026020942 | 2017-07-05 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a 8 5/8 inch diameter surface casing, 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. The valves on the wellhead are closed at the time of inspection. The tank battery is equipped with a 100 barrel steel tank and a horizontal separator. There has been no resolution to the issues on this well and the well is idle at the time of inspection. |
0191011890 | 2017-11-17 | Plug / Plug Back | No Violations | I went to cover a plug job for inspector Sefcik. Upon arrival they pulled the 4.5 inch out to see what they were dealing with. They pulled out 3 range 4 joints, about 130. The pipe pulled apart in the 4.5 at a collar and a very rusty and scaly thread was on bottom. This would indicate that the pipe has been unscrewed for a very long time. They decided the first thing they would try would be to use a steel nipple and try to screw back into the collar that is there. We then decided that if that was successful they would perforate the 4.5 in the lime and set the lime plug. Then cut the pipe above the tight spot approximately 2300-2400 feet, then pump a rip plug. Then plug the rest of the way out. |
0441550199 | 2016-06-14 | Production Wells | No Violations | The purpose of my inspection today is a compliance notice follow up. The well is equipped with 8.625 inch surface casing, 4.5 inch production casing, and 1.5 inch tubing. The well is idle. The production equipment consists of one horizontal separator and one 100 bbl. tank. The 100 bbl. tank is leaking oil and there is a contaminated spot on the ground beside the tank that is 6 ft. by 3 ft. The well and production equipment is overgrown with vegetation. No changes to the well have been made since the inspection by ODNR Inspector Lynn Parkins on 1/16/15. Pictures were taken of the well and the production equipment to assist this inspection. |
1136211834 | 2020-6-10 0:00: | FR | No Violations | 0.50 |
1255546588 | 2008-03-12 | Production Wells | Violations Noted | Inspection this day found casing well with valves shut. Tank has very poor IDs that barely say Tiger Oil and permit no., good dike, no meter, meter housing open. No one has been to this well for long time, dont see how landowner could be using gas. |
1473621454 | 2015-01-16 | Production Wells | No Violations | Upon inspection, it was observed that no effort has been made to bring this well into compliance since my last inspection on 6/10/2014. I spoke with a representative from Energy Contractors/Tiger Oil and he stated that they sold this well to Northwood a few years ago. I explained to him that the well still shows on their bond and they are responsible for it. He stated that he would contact Northwood Energy and ask why the bond transfer was never completed and also stated that Energy Contractors would plug the well if necessary. |
1474212508 | 2020-6-30 0:00: | PW | No Violations | 0.80 |
1534350406 | 2018-08-15 | Plug / Plug Back | No Violations | The well has been plugged. The violation has been resolved. The inspector did not file a plug report as required and he is no longer employed by the Division. |
1800655951 | 2008-03-12 | Production Wells | No Violations | FOLLOW UP TO NOV # -1255546588 Inspection this day found casing well with valves shut. Tank has very poor IDs that barely say Tiger Oil and permit no., good dike, no meter, meter housing open. No one has been to this well for long time, dont see how landowner could be using gas. |
1960768901 | 2014-06-10 | Production Wells | No Violations | There has been no change at this well location since the last inspection by Inspector Andy Thomas on 3/31/14. I called Energy Contractors Inc. and they answered the phone as Tiger Oil, which is the operator name listed on the tank battery. I left the secretary my phone number and she said the owner would contact me as soon as possible to discuss plans for this well. |
1966134910 | 2017-08-14 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a 8 5/8 inch diameter surface casing, 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. The valves on the wellhead are closed at the time of inspection and there are no lines connected to the wellhead. The tank battery for this well consists of a 100 barrel steel tank and a horizontal separator. There are two tanks near the wellhead but only one of the tanks has the matching permit number for this well. There has been no resolution to the issues on this well and the well is idle and has no identification at the time of inspection. |
2033544190 | 2014-03-31 | Production Wells | No Violations | Well is not equipped for production. It has a 4.5 in. well head with 1.5 in. tubing in it. There is a valve with a swage and a tee on it. The valve is closed and there is no plug in the tee. The valves on the annular connections. There are no production lines connected to the well. The 100 barrel tank on the site is leaking. It has contaminated an area 2.5 ft. by 3 ft. I called the phone number supplied by RBDMS and left a message explaining what I saw and for them to call me. |
2039004298 | 2017-06-29 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with 8 5/8 inch diameter surface casing and 4 1/2 inch diameter production tubing. The valves are closed on the wellhead at the time of inspection. There are no lines attached to the wellhead and no plugs are in place where the lines should be. The tank battery is equipped with two (2) 100 barrel steel tanks with no identification and a horizontal separator that has been overgrown with brush. There has been no resolution to the issues on this well and the well is idle at the time of inspection. |
441550199 | 2016-6-14 0:00: | PW | No Violations | 3.00 |
PL1533 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1255546588 | US-OH-106884 | 2008-03-20 | Failure to legibly identify well | |
1255546588 | US-OH-106885 | 2008-03-20 | Well shall be plugged |
For data sources see[9]