34-035-22050

Well Details

Well ID: 34-035-22050
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: PANZICA
License Status: Producing
License Date: 2008-07-07
Spud Date: 2008-08-07
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-08-09
Well Total Depth: 3495.00 ft
Configuration: Vertical
Latitude: 41.540000
Longitude: -81.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-07 Proposed Formations:CLINTON, Issued Date:7/7/2008, Expired Date:7/7/2009 6:00:00 AM, Drilling unit acres:20.05, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-08-09
Change of Owner 2008-10-29 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 7447, GREAT PLAINS EXPLORATION LLC
Completion Report Received 2008-10-29
Correction to Well 2009-05-29 UNIT SIZE REVISED TO 20.557 ACRES.
Construction Permit Expires 2009-07-07
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-12-02 3326 3348 20
3326 3348 20
3326 3348 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 586 Mscf 100000 FRAC ALSO USED 270 BBLS OF WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 GREAT PLAINS EXPLORATION LLC 148624.00 0.00 365
2010 GREAT PLAINS EXPLORATION LLC 45755.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 24680.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 17355.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 12272.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 11504.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 7581.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 263.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 GREAT PLAINS EXPLORATION LLC Brine 160 365
2010 GREAT PLAINS EXPLORATION LLC Brine 160 365
2011 GREAT PLAINS EXPLORATION LLC Brine 0 365
2012 GREAT PLAINS EXPLORATION LLC Brine 0 366
2013 GREAT PLAINS EXPLORATION LLC Brine 0 365
2014 GREAT PLAINS EXPLORATION LLC Brine 0 365
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1131798055 2015-2-20 0:00: UP No Violations 0.50
-1208016469 2012-1-11 0:00: UL No Violations 1.00
-1350085612 2017-9-5 0:00:0 UP No Violations 0.50
-1376485229 2008-8-12 0:00: DD No Violations
-1584648627 2008-8-28 0:00: DD No Violations
-1908999113 2008-10-14 0:00 DD No Violations
-410348822 2008-8-7 0:00:0 DD No Violations
-517715061 2009-4-27 0:00: PW No Violations
-566902847 2013-1-8 0:00:0 UP No Violations
-606466269 2008-8-7 0:00:0 DD No Violations
0199321499 2018-05-30 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and secure and the unit identification was no longer readable and had not been updated to reflect the change of ownership that had occurred in 2015. At the time of this inspection, I observed the following: the load line valves and gate were locked but the ID signage remained missing. I had previously contacted the company about the defficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
0410348822 2008-08-07 Drill / Deepen / Reopen No Violations drilling at 2750 will drill into the newburgh around noon today.
0517715061 2009-04-27 Production Wells No Violations no violation
0566902847 2013-01-08 UrbanProduction Wells No Violations The producing unit is comprised of a two-tank battery (2 140-barrel, 1 20-barrel) with mechanical separator and wellhead valve assembly with mechanical plunger lift. The tank battery is enclosed in an 8-foot chain-link enclosure. The wellhead is in a 6-foot chain-link enclosure. The well is currently producting. The secondary containment is adequate. Unit identification is present and legible at the tank battery. The unit gates and loadouts are locked. I did not observe any leaks, spills, or other signs of contamination .HB 278 saftey equipment is present.
0606466269 2008-08-07 Drill / Deepen / Reopen No Violations drilling at 2870 no gas in newburgh
1131798055 2015-02-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead mechanical plunger lift and tank battery enclosures are locked and secure. System fittings and connections are secure and free from signs of leakage or problems. Load-outs are plugged, locked and secure. ID signage is in poor condition and needs replaced. Access to the unit is shared with the adjacent commercial office complex. At the time of this inspection, there is 12 to 14 inches of snow cover which obscures some surficial features.
1208016469 2012-01-11 UrbanPreliminary Restoration No Violations On 01/11/2012, DNR Inspector Richard Skidmore completed an urban production well inspection status check for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1218716162 2008-08-12 Drill / Deepen / Reopen No Violations rig moveing off to portage cty.
1350085612 2017-09-05 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
1367983773 2008-08-03 Drill / Deepen / Reopen No Violations surface cementing 8 5/8 casing.
1376485229 2008-08-12 Drill / Deepen / Reopen No Violations checked site no violation
1456955725 2016-03-02 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system in a chain-link enclosure. A tank battery comprised of two 100-barrel steel tanks, a mechanical separator in separate chain-link enclosure. The battery enclosure gate was locked and secure. The wellhead enclosure gate was open and unsecure. The surface casing nipple was exposed but not gauged as required by permit condition. Fittings and connections were bull-plugged and secure with locks. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The well ID was missing. The owner must remedy the following by 04/04/2016: replace the missing signage. Lock the well enclosure. Place a gauge at the surface casing nipple as required by permit condition. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1493855692 2017-12-07 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and secure and the unit identification was no longer readable and had not been updated to reflect the change of ownership that had occurred over 12 months prior. At the time of this inspection, I observed the following: the load line valves and gate were locked but the ID signage remained missing. I had previously contacted the company about the defficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
1545131372 2008-10-01 Drill / Deepen / Reopen No Violations company working on tank battery
1570384516 2009-11-30 Production Wells No Violations No violation
1584648627 2008-08-28 Drill / Deepen / Reopen No Violations Fence is around well head,well shut in.
1636376429 2009-01-05 Preliminary Restoration No Violations Well in parking lot no grass disturbed
1739105614 2008-09-17 Drill / Deepen / Reopen Violations Noted Tank battery to close to building to the north. Company in process of finding a spot to put the tank battery.VERBLE NOV
1793764171 2017-03-13 UrbanProduction Wells No Violations I inspected this production well as a follow-up to a previous inspection and associated Compliance Notice issued for the following deficiencies; missing locks on the enclosure gates and missing identification. At the time of this inspection the noted issues remained. I contacted John Magnussen with David Oil. He reported that they are addressing the issues as they are able.
1908999113 2008-10-14 Drill / Deepen / Reopen No Violations field checking location
1944647578 2008-08-04 Drill / Deepen / Reopen No Violations surface 8.5 cementing on 08-03-08 drilling shale depth 650.
1982871453 2008-08-02 Drill / Deepen / Reopen No Violations Cemented conductor

Company used fire hydrant for fresh water(city water).Company had to get a permit from City of Cleveland Department of water.

199321499 2018-5-30 0:00: UP No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1456955725 US-OH-113238 2016-04-27 ID (a-i)
1456955725 US-OH-113239 2016-04-27 LOCKS
1739105614 US-OH-117263 2008-11-20 Failure to meet setback requirements

For data sources see[9]