Well ID: 34-059-24335 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40,"lon":-81.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Wills Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-000824 | |
Farm/Lease Name: SHUGERT DADDY WLS GR | |
License Status: Producing | |
License Date: 2014-03-19 | |
Spud Date: 2014-05-08 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2014-05-27 | |
Well Total Depth: 16735.00 ft | |
Configuration: Horizontal | |
Latitude: 40.000000 | |
Longitude: -81.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-02-24 | Proposed Formations:POINT PLEASANT, Issued Date:2/24/2014, Expired Date:2/24/2016 12:00:00 PM, Drilling unit acres:737.332, Proposed Well Type:OG, Proposed Well Class:EDPW |
APP | 2014-03-19 | Proposed Formations:POINT PLEASANT, Issued Date:3/19/2014, Expired Date:3/18/2016 12:00:00 PM, Drilling unit acres:466.807, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2014-05-27 | |
Correction to Well | 2014-07-11 | CHANGE TO TARGET AND TAKE-PONT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
Completion Report Received | 2015-07-08 | |
Change of Owner | 2015-08-19 | Operator changed from 9193, AMERICAN ENERGY UTICA LLC to 9520, ASCENT RESOURCES UTICA LLC |
Construction Permit Expires | 2016-03-18 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 07/30/2014 | 08/18/2014 | 7150 | 12,032,400.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | H075%, H010%, Slickwater, WF115, WF120 | Schlumberger | Corrosion Inhibitor, Bactericide (Myacide GA25), Scale Inhibitor, AntiFoam Agent, Acid, Breaker, Gelling Agent, Friction Reducer, Iron Control Agent, | Dodecamethylcyclohexasiloxane | 540-97-6 | 0 | 0 | 0 |
Ethanol, 2,2',2-nitrilotris-,
1,1',1-tris(dihydrogen phosphate), sodium salt |
68171-29-9 | 0.01316 | 0.00194 | 0 | ||||
Acetic acid | 64-19-7 | 0 | 0 | 0 | ||||
Vinylidene chloride/methylacrylate copolymer | 25038-72-6 | 0.00529 | 0.00078 | 0 | ||||
Water (Including Mix Water Supplied by Client)* | NA | 0 | 85.2288 | 0 | ||||
Ethane-1,2-diol | 107-21-1 | 0.00165 | 0.00024 | 0 | ||||
Crystalline silica | 14808-60-7 | 98.0819 | 14.4879 | 0 | ||||
Magnesium silicate hydrate (talc) | 14807-96-6 | 0.00016 | 0.00002000 | 0 | ||||
Octamethylcyclotetrasiloxane | 556-67-2 | 0.00001000 | 0 | 0 | ||||
Dimethyl siloxanes and silicones | 63148-62-9 | 0.00006000 | 0.00001000 | 0 | ||||
poly(tetrafluoroethylene) | 9002-84-0 | 0.00007000 | 0.00001000 | 0 | ||||
Acrylamide, 2-acrylamido-2-methylpropanesulfonic
acid, sodium salt polymer |
38193-60-1 | 0.06754 | 0.00998 | 0 | ||||
Guar gum | 9000-30-0 | 0.59475 | 0.08785 | 0 | ||||
Alcohols, C14-15, ethoxylated (7EO) | 68951-67-7 | 0.00097 | 0.00014 | 0 | ||||
Glycerol | 56-81-5 | 0.02358 | 0.00348 | 0 | ||||
Trisodium ortho phosphate | 7601-54-9 | 0.00579 | 0.00085 | 0 | ||||
Diammonium peroxidisulphate | 7727-54-0 | 0.05431 | 0.00802 | 0 | ||||
Alkenes, C>10 a- | 64743-02-8 | 0.00043 | 0.00006000 | 0 | ||||
Crosslinked PO/EO-block polymer | 68123-18-2 | 0.02133 | 0.00315 | 0 | ||||
Polymer of 2-acrylamido-2-methylpropanesulfonic
acid sodium salt and methyl acrylate |
136793-29-8 | 0.00724 | 0.00107 | 0 | ||||
2-ethylhexan-1-ol | 104-76-7 | 0.00009000 | 0.00001000 | 0 | ||||
Cholinium chloride | 67-48-1 | 0.04321 | 0.00638 | 0 | ||||
Propan-2-ol | 67-63-0 | 0.0711 | 0.0105 | 0 | ||||
Siloxanes and Silicones, di-Me,
reaction products with silica |
67762-90-7 | 0.00001000 | 0 | 0 | ||||
Urea | 57-13-6 | 0.00444 | 0.00066 | 0 | ||||
Alcohol, C11-14, ethoxylated | 78330-21-9 | 0.00709 | 0.00105 | 0 | ||||
Methanol | 67-56-1 | 0.00345 | 0.00051 | 0 | ||||
Polypropylene glycol | 25322-69-4 | 0.00109 | 0.00016 | 0 | ||||
Potassium oleate | 143-18-0 | 0.00005000 | 0.00001000 | 0 | ||||
Sodium sulfate | 7757-82-6 | 0.00104 | 0.00015 | 0 | ||||
Dioctyl sulfosuccinate sodium salt | 577-11-7 | 0.00332 | 0.00049 | 0 | ||||
Decamethyl cyclopentasiloxane | 541-02-6 | 0 | 0 | 0 | ||||
Fatty acids, tall-oil | 61790-12-3 | 0.00254 | 0.00037 | 0 | ||||
Methyl oxirane polymer with oxirane | 9003-11-6 | 0.00703 | 0.00104 | 0 | ||||
Propylene glycol | 57-55-6 | 0.00071 | 0.00011 | 0 | ||||
Acetic acid, potassium salt | 127-08-2 | 0.00001000 | 0 | 0 | ||||
Copper(II) sulfate | 7758-98-7 | 0 | 0 | 0 | ||||
Non-crystalline silica | 7631-86-9 | 0.00254 | 0.00038 | 0 | ||||
Hydrogen chloride | 7647-01-0 | 0.78915 | 0.11657 | 0 | ||||
Alkyl (c10-c14) alcohols, ethoxylated | 66455-15-0 | 0.0071 | 0.00105 | 0 | ||||
Tetrasodium ethylenediaminetetraacetate | 64-02-8 | 0.00012 | 0.00002000 | 0 | ||||
Oleic acid | 112-80-1 | 0.00004000 | 0.00001000 | 0 | ||||
Glutaraldehyde | 111-30-8 | 0.0349 | 0.00515 | 0 | ||||
2-propenamid | 79-06-1 | 0.00022 | 0.00003000 | 0 | ||||
Thiourea, polymer with formaldehyde and 1-phenylethanone | 68527-49-1 | 0.00209 | 0.00031 | 0 | ||||
Ammonium sulfate | 7783-20-2 | 0.0915 | 0.01352 | 0 | ||||
Sodium erythorbate | 6381-77-7 | 0.05038 | 0.00744 | 0 | ||||
Prop-2-yn-1-ol | 107-19-7 | 0.00065 | 0.0001 | 0 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | AMERICAN ENERGY UTICA LLC | 186941 | 57650 | 96 |
2015 | ASCENT RESOURCES UTICA LLC | 373490 | 112080 | 342 |
2016 | ASCENT RESOURCES UTICA LLC | 387010 | 77921 | 365 |
2017 | ASCENT RESOURCES UTICA LLC | 245441 | 40602 | 344 |
2018 | ASCENT RESOURCES UTICA LLC | 192107 | 30586 | 365 |
2019 | ASCENT RESOURCES UTICA LLC | 36385 | 5286 | 87 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | AMERICAN ENERGY UTICA LLC | Brine | 15700 | 96 |
2015 | ASCENT RESOURCES UTICA LLC | Brine | 15857 | 342 |
2016 | ASCENT RESOURCES UTICA LLC | Brine | 7280 | 365 |
2017 | ASCENT RESOURCES UTICA LLC | Brine | 4927 | 344 |
2018 | ASCENT RESOURCES UTICA LLC | Brine | 2630 | 365 |
2019 | ASCENT RESOURCES UTICA LLC | Brine | 543 | 87 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1510413715 | 2018-5-16 0:00: | PW | No Violations | 0.20 |
-206205361 | 2016-10-25 0:00 | PW | No Violations | 0.50 |
-2093670151 | 2016-2-9 0:00:0 | PW | No Violations | 1.50 |
-42588021 | 2020-6-15 0:00: | PW | No Violations | 1.00 |
0206205361 | 2016-10-25 | Production Wells | No Violations | On the day inspection I witnessed the production equipment included a GP Unit, a line heater, a vapor recovery system, 2- NGL tanks, a compressor unit, a heater treater, a stabilizer unit, a vertical vent scrubber, a combustor unit and a total of 12-500 barrel tanks all within containment and shared with the 1H and the 5H. The well was equipped with a plunger lift system with valves in the open position. Gauges present read 220 pounds per square inch on the tubing and 230 pounds per square inch on the casing with annular pressure monitoring in place. Identification was present and production records were current. |
0748639818 | 2018-07-20 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with valves in the open position. Gauges were present on all casing strings. The production equipment consisted of one indirect line heater, three gas production units, one vertical heater treater, one compressor, one vapor recovery tower, one vertical vent scrubber, one combustor and twelve 400-barrel tanks. |
1205655088 | 2015-04-15 | Production Wells | No Violations | On the day inspection accompanied ODNR Inspector Matt Fulk, I witnessed the production equipment included currently flowing with 1250psi on the tubing and 1950psi on the casing. |
1359293280 | 2014-09-29 | Production Wells | No Violations | I walked through the production facility with Kevin Eshbaugh the Production Forman. There are three wells on pad that are producing. The reason for my visit was based on a complaint # 4818. There was no vibration coming from the pad. |
1394640925 | 2014-03-12 | Drill / Deepen / Reopen | No Violations | On the day of my inspection, I witnessed Express Energy Services break circulation with fresh water then displace two hundred and ninety sacks of Class A cement with a weight of 15.6 and a yield of 1.18, I witnessed fourteen barrels of cement returns back to the cellar. |
1398783147 | 2014-04-29 | Drill / Deepen / Reopen | No Violations | On the day of my site inspection I witnessed the Nomac Rig #137 tripping the drill string string in and out of the well bore to free up the tool that was hung at a depth of 12,000, the pad appeared to be stable, there was no erosion and vegetation was established. |
1399985240 | 2014-05-09 | Drill / Deepen / Reopen | No Violations | On the day of my inspection, I witnessed O-Tex Pumping, LLC circulate the hole with fresh water then mix and displace 980 sacks of Premium H 2% cement back to surface with forty seven barrels of cement returns to surface, I also witnessed O-Tex bump the plug ,( the floats held ) before releasing the pressure. |
1510413715 | 2018-05-16 | Production Wells | No Violations | The purpose of my inspection was a follow up on complaint numbered 5834. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of twelve 400 barrel tanks, three line heaters, and three gas production units, one heater treater, one compressor, vertical vent scrubber, and a combustor. At the entry of the lease road I could not hear any noises coming from the pad. Upon entry of the pad the compressor can be heard operating. |
1579184010 | 2020-1-16 0:00: | PW | No Violations | 0.50 |
1599838713 | 2020-9-11 0:00: | PW | No Violations | 1.00 |
1608556276 | 2019-02-12 | Production Wells | No Violations | The purpose of my inspection was a follow up on complaint numbered 5834. The complaint was made due to the noises coming from a compressor. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present the 13.375-inch diameter surface casing had 0 pounds per square inch and the 9.625-inch diameter intermediate had 535 pounds per square inch. The production equipment consisted of twelve 400-barrel tanks, three gas production units, one heater treater, vertical vent scrubber, and a combustor. The compressor that was the cause of the complaint has been removed. |
1710305603 | 2017-03-08 | Production Wells | No Violations | On the day inspection I witnessed the production equipment included a GP Unit, a line heater, a vapor recovery system, 2- NGL tanks, a compressor unit, a heater treater, a stabilizer unit, a vertical vent scrubber, a combustor unit and a total of 12-400 barrel tanks all within containment and shared with the 1H and the 5H. The well was equipped with a plunger lift system with valves in the open position. Gauges present read 200 pounds per square inch on the tubing and 250 pounds per square inch on the casing with annular pressure monitoring in place. Identification was present and production records were current. |
1740494021 | 2015-01-06 | Preliminary Restoration | No Violations | On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A. |
2093670151 | 2016-02-09 | Production Wells | No Violations | On the day inspection following up on complaint ID 5246, I witnessed the production equipment included currently online with 1100psi on the tubing and 1200psi on the casing. Further inspection revealed no violations with production |
748639818 | 2018-7-20 0:00: | PW | No Violations | 0.30 |