PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
1098606969 2013-09-04 Upon inspection I found pits filled and a the well was equipped with a pumping unit. It was pumping at time of arrival. Artex removed the highwall and created a nice slope at the wellhead. There area still does not meet preliminary restoration requirements.
1352012261 2012-11-04 Warren rig 7 is drilling and setting conductor pipe to 100'of 13.37536lb/ft in a 105' of 17.5open hole. Circulation was established.
1352221121 2012-11-05 I was on location to witness the cementing of the 9 5/8 surface casing. The Warren rig #2 drilled a 12 1/4" hole to a TD of 762'. The casing shoe depth was 689'. Centralizers were not run on the surface casing and the insert was at a depth of 647'. The pipe was pressure tested and chart was recorded by Artex. The manifold valves were leaking however surface job had good returns and was successful.
1352491438 2012-11-05 Warren rig 7 was setting surface pipe to 689'of 9.625casing in a 12.25open hole. Formation Cementing is on location to cement casing in place. Good circulation and returns. Artex tried to test on insert after landing plug to 800 psi. The cementers manifold was leaking. Tried testing several times. Cement did not drop back.
1352914734 2012-11-09 Warren rig 7 is setting 720lb/ft range 3 casing in a 8.875open hole. This string is casing of a potential loss circulation zone. There was a Back-off collar at 2126'. There are float shoe at 2901' and baffle insert at 2858'. There has been 3 centralizes ran at the bottom 3 joints. Universal services were in to cement pipe in place in the well bore. Circulation was established. Top of cement should be at 2250'.The casing was tested upon landing the plug at the insert. Test pressure was at 780 psi. Test passed.
1354643580 2012-12-04 Jason Ritchie from Artex called and said they were going to perf well at 1:00pm. I arrived on location to witness Artex perf job at 12:50pm and Gray Wireline on site. They had just finished perforating the well. Service company then ran 2" tubing downhole in preparation for acid job. Treatment for well will be tomorrow morning. The perforated intervals were 6249.8-6343.7 with 79 holes.
2029906639 2013-06-03 I accompanied Joe Schneider and Frank Riggle in the field to review the restoration work at all of Artex's most recently drilled wells. The pit was filled and an active pumping unit at this location. They will be moving equipment in about 10 days to work on the access road and well location.
700093694 2013-10-22 Preliminary restoration is passed in accordance to 1509.072.
878854413 2013-04-10 Upon inspection I found pits filled and a the well was equipped with a pumping unit. It was pumping at time of arrival. The road and location had not yet been restored so I called Frank, with Artex, and he said they were still waiting for the area to dry out. They also need to grade the highwall. He said he would call me here soon when they move onto location for restoration work.