{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.7113887326,"lon":-81.4621544324,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1977-03-17 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 4 | |
Latitude: 39.7113887326 | |
Longitude: -81.4621544324 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1113519381 | 2011-01-05 | Inspection revealed no change in status of well it still remains idle& incapable of producing.
Mote: Sulfur odor detected at wellhead, suspect hole in casing and possibly H2S may be present. Talked to company rep 1/12/11 concerning outstanding violations at well he stated that they would plug/plug back this well later on in the year. |
||||
-1151881590 | 2014-06-16 | I am onsite to follow up on Chiefs Order 2014-127. My inspection finds the well has not been repaired and the 4.5" casing is still open to atmosphere. The well is not capable of controlling the flow of gas and oil. The well is not equipped in a manner that would allow it to be produced and there are no pipelines attached to the well. | ||||
-1493074441 | 2013-12-12 | The status of the well has not changed. The well has not been repaired and is still not capable of preventing the escape of gas or oil. | ||||
-1751817200 | 2012-11-26 | Stopped at the location to see if Stonebridge has moved a service rig in to begin plug back operations. The well is equipped with 4.5" casing, and is not in production. | ||||
-269068064 | 2007-02-15 | No change in status of well (still idle venting trace amounts of H2S) have tried to contact well owner with no results left messages on John Snieders phone with no return calls noted so a Chief's Order is requested to plug/plugback said well. | 9-9-05(A)10 | |||
-269068064 | 2007-02-15 | No change in status of well (still idle venting trace amounts of H2S) have tried to contact well owner with no results left messages on John Snieders phone with no return calls noted so a Chief's Order is requested to plug/plugback said well. | NONE | |||
-280445812 | 2014-01-16 | My inspection today finds the 4.5" casing has still not been repaired. The well is open to atmosphere and a small amount of gas is escaping the well. I noticed a slight sulfur smell. I will contact the company about repairing the well. | ||||
-622441750 | 2014-02-05 | I called John Snyder with Stonebridge Operating and left a message for him to call me back. I left my contact information on the message. | ||||
-800615410 | 2014-08-28 | Attended Board of review hearing in Columbus and decision was agreed upon that Stonebridge would plug well within a sixty day time frame. | ||||
1134139438 | 2014-02-25 | My inspection finds the well has still not been repaired. The casing is still open to atmosphere. The well is incapable of production. The company has filled production for 2011 and 2012 even though previous inspections have determined the well was not capable of production. Photos were taken. A Chiefs Order has been prepared. | ||||
1255797599 | 2009-10-16 | Inspection revealed that well is still incapable of producing, production tank has been removed since my last inspection there is a slight odor coming from wellhead area(H2S) Sulphur odor. | ||||
1278971006 | 2014-08-18 | My inspection finds the well has not been repaired. The 4.5" casing is still broken off at the surface. | ||||
1381948376 | 2013-10-08 | My inspection today finds the 4.5" casing has failed at the surface. The casing has broken off at the top of the well head. The well is not equipped to prevent the escape of gas and oil. The casing is defective. I spoke to Charles Buckalou, well tender for Stonebridge, and made him aware of the condition of the well. | ||||
1884876641 | 2006-09-22 | Upon inspecting well site found well to be idle last production reported on said well was back in 1993,well is equipped 8" surface casing and 4.5" production casing with swedge and valve on top all valves are closed suspect H2S has broken in on casing, well has 1-100 bbl tank on sight that is full of holes also there is a separator on site not hooked up. | 9-9-05(A)10 | |||
1884876641 | 2006-09-22 | Upon inspecting well site found well to be idle last production reported on said well was back in 1993,well is equipped 8" surface casing and 4.5" production casing with swedge and valve on top all valves are closed suspect H2S has broken in on casing, well has 1-100 bbl tank on sight that is full of holes also there is a separator on site not hooked up. | NONE | |||
325656336 | 2014-02-28 | I called Mr. John Snyder of Stonebridge Operating at 11:17 am. I discussed the outstanding violations against the well with Mr. Snyder. Mr. Snyder stated that he was planning to get a permit to plug the well. He also stated that the proper identification would be in place by 3/7/14. | ||||
416547355 | 2014-06-18 | |||||
491539565 | 2013-07-11 | I called and spoke to Mr. John Snyder. I told him that the plug back permit for the well would be expiring soon and that something needed to be done with the well. Mr. Snyder stated that he intended to begin work on the well in the next two months weather permitting. | ||||
861916681 | 2014-02-05 | Mr. John Snyder returned my call at 4:54 pm. I told Mr. Snyder that due to the fact the well has been out of compliance for eight years and the casing has broken off at the surface, the company must make repairs or plug the well immediately. He stated that he would begin the permit process to plug or plug back. |