If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31082 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.889941,"lon":-79.645016,"icon":""}]} |
County: Armstrong | |
Municipality: West Franklin Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 147121 | |
Farm/Lease Name: FLEEGER UNIT 1M-107.6 | |
First Permit Date: 2012-07-25 | |
Last Permit Date: 2012-07-25 | |
Spud Date: 2012-09-07 | |
Unconventional: Yes | |
Horizontal: No | |
Well Status: ACTIVE | |
Violations: 0 | |
Latitude: 40.889941 | |
Longitude: -79.645016 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2012-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-2 | 30346.0 | 131.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-1 | 24956.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-2 | 17633.0 | 182.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-02 | 2259.0 | 28.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-01 | 2319.0 | 30.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-03 | 2212.0 | 30.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2012-2 | DRILL CUTTINGS | 105.0 | Tons | ON SITE ENCAPSULATION | ON SITE DISPOSAL PURSUANT TO 25 PA CODE 78.62 | PA | ||
2013-1 | FRACING FLUID WASTE | 1.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW006 | CAES WATER TRMT & RECYCLING FAC | CLARION | PA |
2013-2 | PRODUCED FLUID | 120.0 | Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW006 | CAES WATER TRMT & RECYCLING FAC | CLARION | PA |
2013-2 | PRODUCED FLUID | 90.0 | Bbl | INJECTION DISPOSAL WELL | 34-155-21438 | KLEESE #1 (SWIW #18) | VIENNA | OH |
2013-2 | PRODUCED FLUID | 93.0 | Bbl | INJECTION DISPOSAL WELL | 34-155-23732 | KLEESE #4 (SWIW #24) | VIENNA | OH |
2013-2 | PRODUCED FLUID | 177.0 | Bbl | INJECTION DISPOSAL WELL | 155-23223 | NATALE #2 (SWIW #29) | VIENNA | OH |
2014-1 | PRODUCED FLUID | 93.0 | Bbl | INJECTION DISPOSAL WELL | 34-155-21447 | KLEESE #2 (SWIW #19) | VIENNA | OH |
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
2098847 | 2012-09-11 | No Violations Noted | At the time of inspection the drill rig was onsite and was properly placed on containment. The drill pit located onsite appeared to be in sound condition with the required 2 feet of freeboard. The E&S plan was also onsite and all BMPs appeared to be in sound condition and installed per the approved plan. No accelerated erosion or sedimentation observed in relation to the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the site stability in maintained. | |||
2100951 | 2012-09-19 | No Violations Noted | At the time of inspection the well appeared to be drilled however was not stimulated or equipped for production. The drill pit located onsite appeared to be in sound condition with the required 2 feet of freeboard. The E&S plan was also onsite and all BMPs appeared to be in sound condition and installed per the approved plan. No accelerated erosion or sedimentation observed in relation to the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the site stability in maintained. | |||
2134702 | 2013-01-30 | No Violations Noted | Well shut in on 4 1/2ï¾” x 2ï¾” swage. Pit lined and freeboard maintained.
Small expression of gas at base of wellhead. |
|||
2170513 | 2013-05-24 | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it contained fluids and drill cuttings. Drill pit had more than the required two feet of lined freeboard. Drill pit liner appeared to be intact. E&S controls ahd been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. | |||
2178222 | 2013-06-26 | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it contained fluids and drill cuttings. Drill pit had more than the required two feet of lined freeboard. Drill pit liner appeared to be intact. E&S controls ahd been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. The Department recommends that the operator inspect the access road and its erosion controls for any necessary maintenance or repairs after the recent storm events. | |||
2196968 | 2013-08-13 | No Violations Noted | Well appeared to be equipped for production. Brine tanks were located and they appeared to be in sound condition. E&S controls had been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. | |||
2212599 | 2013-10-15 | No Violations Noted | Well appeared to be equipped for production. Brine tanks were located and they appeared to be in sound condition. E&S controls had been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. Site had been seeded, mulched and the vegetation had begun to take hold. There were several areas on the fill slope where the seed has not yet germinated. The operator should monitor this area and if necessary re-seed and mulch. | |||
2365829 | 2015-04-30 | No Violations Noted | Well appeared to be equipped for production |
For data sources see[3]