If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31082 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.889942,"lon":-79.645017,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: West Franklin Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 147121 | |
Farm/Lease Name: FLEEGER UNIT 1M-107.6 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-07-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.889942 | |
Longitude: -79.645017 |
Date | Event |
---|---|
2012-07-25 | New Permit Application |
2012-09-07 | Performed Spud Operation |
2012-09-19 | Drilling Completion |
2013-07-16 | Perforation |
2014-04-10 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-07-18 | 2013-07-18 | 5,976 | 95,216 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Nitrogen per MSCF | Nabors Completion and Production Services | Nitrogen Materials | Nitrogen | 7727-37-9 | 100 | 28.9126 | 0 |
PA Specific 40/70 mesh Sand | Nabors Completion and Production Services | Sand - Bulk - Pennsylvania | Iron Oxide | 1309-37-1 | 0.1 | 0.013859 | 0 | |
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 13.8449 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.013859 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.152446 | 0 | ||||
HCL Acid (0%-7.5%) | Nabors Completion and Production Services | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 7.5 | 0.019608 | 0 | |
Water | 7732-18-5 | 92.5 | 0.241831 | 0 | ||||
WFR-3B | Nabors Completion and Production Services | Friction Reducer | Hydrotreated light distillates, non-aromatic, BTEX free | 64742-47-8 | 30 | 0.029088 | 0 | |
Ethoxylated alcohols | 68002-97-1 | 15 | 0.014544 | 0 | ||||
Ethoxylated oleylamine | 26635-93-8 | 5 | 0.004848 | 0 | ||||
PA Specific 30/50 mesh Sand | Nabors Completion and Production Services | Sand - Bulk - Pennsylvania | Crystalline Silica, quartz | 14808-60-7 | 99.9 | 8.50219 | 0 | |
Aluminum Oxide | 1344-28-1 | 1.1 | 0.093618 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.008511 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.008511 | 0 | ||||
Water | SNYDER BROTHERS INC | Water | Water | 7732-18-5 | 100 | 48.2051 | 0 | |
KR-153SL | Nabors Completion and Production Services | Biocides | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.001109 | 0 | |
Polyethlyene-Glycol | 25322-68-3 | 50 | 0.002773 | 0 | ||||
Other Ingredients | Nabors Completion and Production Services | Other Ingredients | Polymer | Proprietary | 1 | 0.001305 | 0 | |
Proprietary | Proprietary | 100 | 0.130474 | 0 | ||||
Monoethanolamine | Proprietary | 100 | 0.001305 | 0 | ||||
Water | 7732-18-5 | 48 | 0.000481 | 0 | ||||
Alkyl Phosphate Ether | Proprietary | 1 | 0.001305 | 0 | ||||
Solvent | Proprietary | 1 | 0.001305 | 0 | ||||
Proprietary | Proprietary | 15 | 0.000765 | 0 | ||||
Anionic Polyacrylamide | 910644-97-2 | 40 | 0.038784 | 0 | ||||
Dioxane | 123-91-1 | 1 | 0.00001000 | 0 | ||||
Propylene glycol | 57-55-6 | 15 | 0.014544 | 0 | ||||
Proprietary | Proprietary | 50 | 0.002549 | 0 | ||||
Demineralized Water | 7732-18-5 | 50 | 0.000549 | 0 | ||||
ammonium, (2-Hydroxyethyl)trimethyl-, chloride | 67-48-1 | 80 | 0.000878 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 13 | 0.00013 | 0 | ||||
Proprietary | Proprietary | 2 | 0.001939 | 0 | ||||
Proprietary | Proprietary | 1 | 0.001305 | 0 | ||||
Water | 7732-18-5 | 60 | 0.003059 | 0 | ||||
Water | 7732-18-5 | 40 | 0.038784 | 0 | ||||
Water | 7732-18-5 | 50 | 0.065237 | 0 | ||||
Ammonium salts | Proprietary | 100 | 0.026095 | 0 | ||||
Polymer | Proprietary | 10 | 0.013047 | 0 | ||||
Phosphoric Acid | 7664-38-2 | 100 | 0.001305 | 0 | ||||
Water | 7732-18-5 | 80 | 0.004436 | 0 | ||||
ICP-1000 | Nabors Completion and Production Services | Iron Control Additives | Anionic Copolymer | Proprietary | 50 | 0.005603 | 0 | |
Propylene glycol | 57-55-6 | 50 | 0.005603 | 0 | ||||
Acid Inhibitor 2 (AI-2) | Nabors Completion and Production Services | Acid Corrosion Inhibitors | Ethoxylated Nonylphenol | 68412-54-4 | 13 | 0.00013 | 0 | |
Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 10 | 0.0001 | 0 | ||||
Isopropyl Alcohol | 67-63-0 | 40 | 0.000401 | 0 | ||||
Glycol Ethers | 111-46-6 | 40 | 0.000401 | 0 | ||||
Propargyl Alcohol | 107-19-7 | 40 | 0.000401 | 0 | ||||
Super 100 NE | Nabors Completion and Production Services | Surfactants & Foamers | Isopropyl Alcohol | 67-63-0 | 40 | 0.052189 | 0 | |
N-Cocoamidopropyl-N,N-dimethyl-N-2-hydroxypropylsulfobetaine |
68139-30-0 | 15 | 0.019571 | 0 | ||||
Methanol | 67-56-1 | 15 | 0.019571 | 0 | ||||
Glycol Ether | 111-76-2 | 5 | 0.006524 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 30,346.00 | 131 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 42,589.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 25,172.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 22,211.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 20,723.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 14,828.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 12,403.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Drill Cuttings | 105.00 Tons | ON SITE ENCAPSULATION | |
2013 | SNYDER BROS INC | Fracing Fluid Waste | 1,220.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW006 |
2013 | SNYDER BROS INC | Produced Fluid | 177.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | SNYDER BROS INC | Produced Fluid | 120.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW006 |
2013 | SNYDER BROS INC | Produced Fluid | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2014 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2015 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2016 | SNYDER BROS INC | Produced Fluid | 60.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2019 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2098847 | Primary Facility | 2012-09-11 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the drill rig was onsite and was properly placed on containment. The drill pit located onsite appeared to be in sound condition with the required 2 feet of freeboard. The E&S plan was also onsite and all BMPs appeared to be in sound condition and installed per the approved plan. No accelerated erosion or sedimentation observed in relation to the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the site stability in maintained. |
2100951 | Primary Facility | 2012-09-19 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well appeared to be drilled however was not stimulated or equipped for production. The drill pit located onsite appeared to be in sound condition with the required 2 feet of freeboard. The E&S plan was also onsite and all BMPs appeared to be in sound condition and installed per the approved plan. No accelerated erosion or sedimentation observed in relation to the well pad or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the site stability in maintained. |
2134702 | Primary Facility | 2013-01-30 | Drilling/Alteration | No Violations Noted | Well shut in on 4 1/2” x 2” swage. Pit lined and freeboard maintained. |
2170513 | Primary Facility | 2013-05-24 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it contained fluids and drill cuttings. Drill pit had more than the required two feet of lined freeboard. Drill pit liner appeared to be intact. E&S controls ahd been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. |
2178222 | Primary Facility | 2013-06-26 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it contained fluids and drill cuttings. Drill pit had more than the required two feet of lined freeboard. Drill pit liner appeared to be intact. E&S controls ahd been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. The Department recommends that the operator inspect the access road and its erosion controls for any necessary maintenance or repairs after the recent storm events. |
2196968 | Primary Facility | 2013-08-13 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks were located and they appeared to be in sound condition. E&S controls had been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. |
2212599 | Primary Facility | 2013-10-15 | Site Restoration | No Violations Noted | Well appeared to be equipped for production. Brine tanks were located and they appeared to be in sound condition. E&S controls had been properly implmented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. Site had been seeded, mulched and the vegetation had begun to take hold. There were several areas on the fill slope where the seed has not yet germinated. The operator should monitor this area and if necessary re-seed and mulch. |
2365829 | Primary Facility | 2015-04-30 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2765081 | Primary Facility | 2018-08-20 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and two grounded 100 bbl fiberglass fluid collection tanks look ok. |
For data sources see[8]