Well ID: 34-073-22219 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.4921571,"lon":-82.39552386,"icon":""}]} |
County: Hocking | |
Municipality: | |
Operator Name: HOCKING HILLS ENERGY WELL SERV | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1979-12-26 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Producing | |
Violations: 0 | |
Latitude: 39.4921571 | |
Longitude: -82.39552386 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1984-0 | 1823.0 | 472.0 | ||||
1985-0 | 1649.0 | 312.0 | ||||
1986-0 | 169.0 | 46.0 | ||||
1987-0 | 0.0 | 0.0 | ||||
1988-0 | 650.0 | 119.0 | ||||
1989-0 | 820.0 | 111.0 | ||||
1990-0 | 896.0 | 117.0 | ||||
1991-0 | 1200.0 | 54.0 | ||||
1992-0 | 1176.0 | 52.0 | ||||
1995-0 | 550.0 | 47.0 | ||||
1996-0 | 550.0 | 47.0 | ||||
1997-0 | 1361.0 | 0.0 | ||||
1998-0 | 1361.0 | 0.0 | ||||
1999-0 | 1321.0 | 0.0 | ||||
2000-0 | 1202.0 | 0.0 | ||||
2001-0 | 1415.0 | 50.0 | ||||
2002-0 | 1375.0 | 56.0 | ||||
2003-0 | 1100.0 | 43.0 | ||||
2004-0 | 981.0 | 36.0 | ||||
2005-0 | 314.0 | 131.0 | ||||
2006-0 | 837.0 | 54.0 | ||||
2007-0 | 1095.0 | 37.0 | ||||
2008-0 | 1095.0 | 37.0 | ||||
2009-0 | 1095.0 | 37.0 | ||||
2010-0 | 1579.0 | 36.0 | ||||
2011-0 | 775.0 | 34.0 | ||||
2012-0 | 494.0 | 68.0 | ||||
2013-0 | 412.0 | 86.0 | ||||
2014-0 | 342.0 | 365.0 | 14.0 | 365.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
1091450571 | 2004-07-27 | Follow-up on NOV, non-compliance, spoke with Doug Kitchen, he will be working on site later today, working for Murphy Oil at this time, gas line leaking. | Compliance Notice | |||
1091450571 | 2004-07-27 | Follow-up on NOV, non-compliance, spoke with Doug Kitchen, he will be working on site later today, working for Murphy Oil at this time, gas line leaking. | Compliance Notice | |||
1091450571 | 2004-07-27 | Follow-up on NOV, non-compliance, spoke with Doug Kitchen, he will be working on site later today, working for Murphy Oil at this time, gas line leaking. | ||||
1091450571 | 2004-07-27 | Follow-up on NOV, non-compliance, spoke with Doug Kitchen, he will be working on site later today, working for Murphy Oil at this time, gas line leaking. | Field Visit or Inspection | |||
-1110180352 | 2004-09-28 | Follow-up, Non-Compliance, Doug Kiycken and Joe Hoerst on inspection. | ||||
-1153719454 | 2009-10-26 | An inspection revealed that the AD line has now been connected to the well. The P&C from observed discharge on 10/23/2009 has been covered up with dirt. High Range Quantabs placed in fluid outside dike along lease road revealed 9.6 units which exceeds 6545 ppm (mg/L) Cl- for 8.4 units. Checked tank battery located off Skinner Rd (on top of hill) and found that valve on bottom of 100 bbl is still open. | ||||
1256837408 | 2009-10-23 | An inspection was conducted to check status of AD connection. Note: Rainfall event today. The 2 black plastic AD line was disconnected and placed inside earthen dike around well head. The valve was 3/4 open allowing brine and oil to be released onto ground surface. Fresh oil pooled on surface to include oily gravel. The fluid inside dike exceeded maximum High Range Quantab units (10). Note: 8.4 units and equal to 6545 ppm (mg/L) Cl-. Quantabs placed outside the dike ranged from 1079 to 1283 ppm (mg/L) Cl-. Samples were obtained from this inspection. The 2 line is routed from the tank battery for Permit 2211 and 2212 located off Skinner Road approx 1/2 mile away. The valve on the 100 bbl saltwater tank battery was observed open. Report continuted on next page. On 10/23/2009, an unauthorized dishcarge of brine and oil onto ground surface was observed from a 2 AD line. Fresh oil and brine observed on ground surface inside dike. Brine also observed outside the dike along lease road. The burial of contaminated | ||||
1257188614 | 2009-10-23 | 10/23/09 Report Cont: South Region Oil & Gas Supervisor, Mr. Robert Stonerock was notified. At 4:20 pm, a message was left for Mr. Ron McBride on his cell phone regarding well status. Called Mr. Doug Kitchen on his cell phone at 4:23pm, but unable to leave message. At 4:24 pm, I called Mr. Kitchen at his office. He was informed of oil and brine discharge from AD line and to close valve immediately. Mr. Kitchen states he was unaware that valve was open and that Chad is sitting right here and would get it taken care of tonight or Monday. Mr. Kitchen was then instructed to shut off discharge now. Mr. Kitchen responded by saying that he meant that cleanup would be done on Monday and would send Chad to location. Confirmed that discharge derives from tank battery for Permit 2212 and 2211(uphill from location). Informed Mr. Kitchen that AD connection for Permit# 2218 not authorized and to disconnect. He states they will have dozer, would pressure up, change well heads around, and test next week. Waited at location for 1 hour and observed no personnel. | ||||
1260316119 | 2009-12-07 | AD test on well, had to test several times before well passed test. | ||||
-1558167378 | 2009-12-10 | A follow-up inspection was conducted with Mr. Robert Stonerock, South Region Oil & Gas Supervisor. Reviewed and discussed location and source of illegal brine disposal onto ground surface as previously noted. Furthermore, reviewed cleanup that had been performed on-site since this time. This case will be reviewed by management for further legal action therefore, the Notice of Violation will be left open. Note: light snow cover at time of inspection. | ||||
-1895269874 | 2009-11-05 | A follow-up inspection was conducted with Dan Goins. The well status remains the same as AD remains connected to the well. Called Mr. Doug Kitchen at his office at 9:31 am. Instructed Mr. Kitchen to remove connection today. He states that Mr. Ron McBride is on his way. Mr. Mcbride arrived at location and disconnected the AD line at the well. The valve is closed. Mr. McBride states that he will also close the valve at 100 bbl on the hill and that its empty. Mr. McBride was asked about the AD line from location on hill (near ERP). He states that both him and Doug believe there is a potential for 100 bbl to drain to both Permit 2218 and Permit 2219. Further states they are unsure of setup because it was like this when they bought the wells. Explained to Mr. McBride the areas that will require P&C removal (P&C had been buried). | ||||
-2000572575 | 2004-11-26 | Follow-up on NOV, In-Compliance. | ||||
2000579079 | 2004-07-20 | Follow-up on NOV, Non-Complaince, met with Ronnie McBride at site, showed him where to start clean up. | ||||
-2007154601 | 2004-07-13 | AD test on well, well passed test. | ||||
-2047931317 | 2009-09-08 | A follow-up inspection to Revocation Order revealed that annular disposal has not been disconnected or tested. | ||||
-218371379 | 2004-05-04 | An inspection of the well revealed flow line had been leaking and company did not clean up oily soil along lease rd, oily soil in dike at tank battery. | ||||
262978571 | 2004-06-08 | Non-compliance. | ||||
277682018 | 2004-07-28 | Non-Compliance, met Doug Kitchen at site, expalined the clean up that is needed on the lease. | ||||
-32575504 | 2004-06-08 | Non-compliance. | ||||
-351081296 | 2003-05-29 | Follow-up, Non-Compliance, company still has some leveling and seeding to do, kill area still below production tank. Spoke with Doug Kitchen will have work done by 6/2/03. | ||||
368421645 | 2009-11-13 | Witnessed the removal of contaminated soil that had been excavated from impacted areas on 11/12/2009. Observed the placement of soils onto Kilbarger Truck for hauling to landfill. A total of three trips were taken to EPA Approved Landfill. Received 2 run tickets from EPA approved Landfill today, which showed 21.63 tons and 29.49 tons respectively. The third ticket will provided at a later date. New soil, lime, seed and mulch applied to the impacted areas. | ||||
-459406982 | 2007-03-01 | No violations were noted. | ||||
469117952 | 2004-05-13 | An inspection of the well revealed the flow line running across a hay field, the landowner wants the flow line buried or moved along wood line. | ||||
-647860795 | 2004-06-10 | Non-compliance, met with JoeHoerst, Dave Hodges, and Doug Kitchen and his attorney to review violations at well site. | ||||
-702759094 | 2009-11-12 | Witnessed the excavation of contaminated soils from impacted areas at well location. During the cleanup, two lines were observed leaking underground. Approx 2' below ground along lease road, a 2 plastic line was found leaking brine and oil. This line had been clipped while digging. Filled 4 oz sample bottle in 1 minute. Chieftain Energy Contractor, Mr. Ron McBride states this is the old AD line that had been abandoned. Pulled up line and leaks were no longer observed. High Range and Low Range Quantabs revealed unacceptable Cl- values at test intervals. Dug down approximately 6.5' to remove contamination and pollution and find acceptable soil. Overall depth of soil removed 4'- 6.5'. Overall impacted area along lease road measured 46' x 5'. The second line was 2 steel with elbow found 2' below ground inside the dike around well head. I drip every 10 seconds. The fitting was replaced with a plug. Overall depth of soil removed inside dike was 2'- 3'. The dike measured 20' x 9'. Soil will be hauled to EPA approved landfill tomorrow. | ||||
807689039 | 2015-04-10 | Annular Disposaal test. The test was held at 245 PSI for 1 hour with no loss. The test passed. | ||||
-828072389 | 2009-10-07 | A follow-up inspection revealed that annular disposal has been disconnected. Two lines with valves observed to have been connected to annulus with valves open. The tank battery is shared with Logan Sand #4. One (1) 100 bbl tank with knock-out, a 1000 gal polyeurothane tank, separator and drip. Chieftain Contractor, Mr. Ron Mcbride has been previously instructed to disconnect both wells. Mr. Mcbride also stated that they were going to test. High Range Quantabs placed in fluid along lease road revealed 3.4 and 4.0 units in two separate areas, but located directly across from line and well. Fluid along road at location approx 25' x 5'. Brine disposal line contains valve and observed closed. The line has been placed inside earthen dike around well head at time of inspection. Nearby locations away from higher values showed 1.6 units. | ||||
-891381556 | 2004-06-02 | Follow-up on NOV, Non-Compliance,not all C&P soils along lease rd have been cleaned up. Notified Doug Kitchen of vioaltions. | ||||
99529558 | 2006-10-18 | No violations were noted. |