If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-073-22219 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.49,"lon":-82.39,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Hocking | |
Municipality: Green Township | |
Operator Name: HOCKING HILLS ENERGY AND WELL | |
Well Pad ID: | |
Farm/Lease Name: LOGAN SAND & GRAVEL CO | |
License Status: Producing | |
License Date: 1994-01-21 | |
Spud Date: 1979-12-26 | |
Spud Drilling Contractor: MIDWEST | |
Final Drill Date: 1979-12-30 | |
Well Total Depth: 2906.00 ft | |
Configuration: Vertical | |
Latitude: 39.490000 | |
Longitude: -82.390000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1979-11-07 | 2810 CHIEFTAIN ENERGY CORP GeoDate 11/7/79 |
Original Spud | 1979-12-26 | |
Completed | 1979-12-30 | |
Reached Total Depth | 1979-12-30 | |
Annular Disposal Well | 1994-01-21 | |
CO | 1994-07-07 | 4074 OIL ENTERPRISES GeoDate 11/7/79 |
CO | 1997-02-18 | 5755 CHIEFTAIN ENERGY CORP. GeoDate 11/7/79 |
Revocation | 2009-08-05 | |
Last Compliance Report | 2009-12-10 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-12-23 | 2751 | 2766 | 1 |
2751 | 2766 | 1 | |
2751 | 2766 | 1 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1350 Bbl | 50000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1110180352 | 2004-9-28 0:00: | AD | No Violations | |
-1153719454 | 2009-10-26 0:00 | AD | No Violations | |
-1190738113 | 2020-5-12 0:00: | AD | No Violations | 1.50 |
-1237211278 | 2018-5-4 0:00:0 | AD | No Violations | |
-1558167378 | 2009-12-10 0:00 | AD | No Violations | |
-1565561756 | 2020-7-9 0:00:0 | AD | No Violations | 0.50 |
-1895269874 | 2009-11-5 0:00: | AD | No Violations | |
-2000572575 | 2004-11-26 0:00 | AD | No Violations | |
-2007154601 | 2004-7-13 0:00: | AD | No Violations | |
-2027517892 | 2020-5-14 0:00: | AD | No Violations | 1.00 |
-2047931317 | 2009-9-8 0:00:0 | AD | No Violations | |
-218371379 | 2004-5-4 0:00:0 | AD | No Violations | |
-32575504 | 2004-6-8 0:00:0 | AD | No Violations | |
-34364649 | 2020-6-29 0:00: | AD | No Violations | 0.50 |
-351081296 | 2003-5-29 0:00: | AD | No Violations | |
-459406982 | 2007-3-1 0:00:0 | PW | No Violations | |
-647860795 | 2004-6-10 0:00: | AD | No Violations | |
-702759094 | 2009-11-12 0:00 | AD | No Violations | |
-828072389 | 2009-10-7 0:00: | AD | No Violations | |
-891381556 | 2004-6-2 0:00:0 | AD | No Violations | |
0032575504 | 2004-06-08 | Annular Disposal | No Violations | Non-compliance. |
0099529558 | 2006-10-18 | Annular Disposal | No Violations | No violations were noted. |
0218371379 | 2004-05-04 | Annular Disposal | Violations Noted | An inspection of the well revealed flow line had been leaking and company did not clean up oily soil along lease rd, oily soil in dike at tank battery. |
0244179378 | 2019-01-07 | Production Wells | No Violations | My inspection revealed that the well was equipped with a pumping unit and electric motor. This well produces into a shared tank battery with API permit number 2218. The tank battery consists of (1) 100 barrel tank with a knockout tank, (1) 1000 gallon plastic tank, and separator inside an earthen dike. I observed identification at the well and tank battery. The dike was full of water during the inspection. I observed the power line to the well was laying on the ground. The well owner shall pull the power lines off the ground surface with enough clearance so that it wont be in reach. I left my card at the tank battery advising the well owner to drain the water from the dike and to pull the power lines off the ground. I contacted Doug Kitchen on 1/8/2019 and advised him to drain the water from the dike and pull the power lines off the ground. Time of inspection: 1:10 PM. Weather: 45 degrees F, Overcast |
0249650400 | 2019-04-29 | Annular Disposal | Violations Noted | Our records indicate that the Division has not received the Annular Disposal Annual Report (Form 205) that was due on April 15th for 2018, Please submit the Form 205 to the Division by 5/29/2019. |
0258160004 | 2016-05-04 | Annular Disposal | Violations Noted | Our records indicate that the Division has not received the Annular Disposal Annual Report (Form 205) that was due on April 15th for 2015, despite a letter that was sent March 9, 2016 with a deadline of April 15, 2016 to submit the reports requested.Reports received 5/13/2016 |
0262978571 | 2004-06-08 | Annular Disposal | No Violations | Non-compliance. |
0277682018 | 2004-07-28 | Annular Disposal | No Violations | Non-Compliance, met Doug Kitchen at site, expalined the clean up that is needed on the lease. |
0351081296 | 2003-05-29 | Annular Disposal | No Violations | Follow-up, Non-Compliance, company still has some leveling and seeding to do, kill area still below production tank. Spoke with Doug Kitchen will have work done by 6/2/03. |
0368421645 | 2009-11-13 | Annular Disposal | No Violations | Witnessed the removal of contaminated soil that had been excavated from impacted areas on 11/12/2009. Observed the placement of soils onto Kilbarger Truck for hauling to landfill. A total of three trips were taken to EPA Approved Landfill. Received 2 run tickets from EPA approved Landfill today, which showed 21.63 tons and 29.49 tons respectively. The third ticket will provided at a later date. New soil, lime, seed and mulch applied to the impacted areas. |
0459406982 | 2007-03-01 | Production Wells | No Violations | No violations were noted. |
0469117952 | 2004-05-13 | Annular Disposal | Violations Noted | An inspection of the well revealed the flow line running across a hay field, the landowner wants the flow line buried or moved along wood line. |
0647860795 | 2004-06-10 | Annular Disposal | No Violations | Non-compliance, met with JoeHoerst, Dave Hodges, and Doug Kitchen and his attorney to review violations at well site. |
0702759094 | 2009-11-12 | Annular Disposal | No Violations | Witnessed the excavation of contaminated soils from impacted areas at well location. During the cleanup, two lines were observed leaking underground. Approx 2 below ground along lease road, a 2 plastic line was found leaking brine and oil. This line had been clipped while digging. Filled 4 oz sample bottle in 1 minute. Chieftain Energy Contractor, Mr. Ron McBride states this is the old AD line that had been abandoned. Pulled up line and leaks were no longer observed. High Range and Low Range Quantabs revealed unacceptable Cl- values at test intervals. Dug down approximately 6.5 to remove contamination and pollution and find acceptable soil. Overall depth of soil removed 4- 6.5. Overall impacted area along lease road measured 46 x 5. The second line was 2 steel with elbow found 2 below ground inside the dike around well head. I drip every 10 seconds. The fitting was replaced with a plug. Overall depth of soil removed inside dike was 2- 3. The dike measured 20 x 9. Soil will be hauled to EPA approved landfill tomorrow. |
0807689039 | 2015-04-10 | Annular Disposal | No Violations | Annular Disposaal test. The test was held at 245 PSI for 1 hour with no loss. The test passed. |
0828072389 | 2009-10-07 | Annular Disposal | No Violations | A follow-up inspection revealed that annular disposal has been disconnected. Two lines with valves observed to have been connected to annulus with valves open. The tank battery is shared with Logan Sand #4. One (1) 100 bbl tank with knock-out, a 1000 gal polyeurothane tank, separator and drip. Chieftain Contractor, Mr. Ron Mcbride has been previously instructed to disconnect both wells. Mr. Mcbride also stated that they were going to test. High Range Quantabs placed in fluid along lease road revealed 3.4 and 4.0 units in two separate areas, but located directly across from line and well. Fluid along road at location approx 25 x 5. Brine disposal line contains valve and observed closed. The line has been placed inside earthen dike around well head at time of inspection. Nearby locations away from higher values showed 1.6 units. |
0891381556 | 2004-06-02 | Annular Disposal | No Violations | Follow-up on NOV, Non-Compliance,not all C&P soils along lease rd have been cleaned up. Notified Doug Kitchen of vioaltions. |
1091450571 | 2004-07-27 | Annular Disposal | No Violations | Follow-up on NOV, non-compliance, spoke with Doug Kitchen, he will be working on site later today, working for Murphy Oil at this time, gas line leaking. |
1110180352 | 2004-09-28 | Annular Disposal | No Violations | Follow-up, Non-Compliance, Doug Kiycken and Joe Hoerst on inspection. |
1153719454 | 2009-10-26 | Annular Disposal | No Violations | An inspection revealed that the AD line has now been connected to the well. The P&C from observed discharge on 10/23/2009 has been covered up with dirt. High Range Quantabs placed in fluid outside dike along lease road revealed 9.6 units which exceeds 6545 ppm (mg/L) Cl- for 8.4 units. Checked tank battery located off Skinner Rd (on top of hill) and found that valve on bottom of 100 bbl is still open. |
1159735326 | 2020-6-9 0:00:0 | AD | No Violations | |
1237211278 | 2018-05-04 | Annular Disposal | Violations Noted | Our records indicate that the Division has not received the 2017 Annular Disposal Well Annual Report (Form 205) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. reports received 6/27/2018. |
1256837408 | 2009-10-23 | Annular Disposal | Violations Noted | An inspection was conducted to check status of AD connection. Note: Rainfall event today. The 2 black plastic AD line was disconnected and placed inside earthen dike around well head. The valve was 3/4 open allowing brine and oil to be released onto ground surface. Fresh oil pooled on surface to include oily gravel. The fluid inside dike exceeded maximum High Range Quantab units (10). Note: 8.4 units and equal to 6545 ppm (mg/L) Cl-. Quantabs placed outside the dike ranged from 1079 to 1283 ppm (mg/L) Cl-. Samples were obtained from this inspection. The 2 line is routed from the tank battery for Permit 2211 and 2212 located off Skinner Road approx 1/2 mile away. The valve on the 100 bbl saltwater tank battery was observed open. Report continuted on next page. On 10/23/2009, an unauthorized dishcarge of brine and oil onto ground surface was observed from a 2 AD line. Fresh oil and brine observed on ground surface inside dike. Brine also observed outside the dike along lease road. The burial of contaminated |
1257188614 | 2009-10-23 | Annular Disposal | No Violations | 10/23/09 Report Cont: South Region Oil & Gas Supervisor, Mr. Robert Stonerock was notified. At 4:20 pm, a message was left for Mr. Ron McBride on his cell phone regarding well status. Called Mr. Doug Kitchen on his cell phone at 4:23pm, but unable to leave message. At 4:24 pm, I called Mr. Kitchen at his office. He was informed of oil and brine discharge from AD line and to close valve immediately. Mr. Kitchen states he was unaware that valve was open and that Chad is sitting right here and would get it taken care of tonight or Monday. Mr. Kitchen was then instructed to shut off discharge now. Mr. Kitchen responded by saying that he meant that cleanup would be done on Monday and would send Chad to location. Confirmed that discharge derives from tank battery for Permit 2212 and 2211(uphill from location). Informed Mr. Kitchen that AD connection for Permit# 2218 not authorized and to disconnect. He states they will have dozer, would pressure up, change well heads around, and test next week. Waited at location for 1 hour and observed no personnel. |
1260316119 | 2009-12-07 | Annular Disposal | No Violations | AD test on well, had to test several times before well passed test. |
1548942332 | 2019-01-31 | Production Wells | No Violations | My inspection revealed that the power line has not been pulled off the ground. I issued a compliance notice to Hocking Hills Energy and Well Service on 1/9/2019 for general safety. During that inspection I observed that the dike was full of water. I advised Doug Kitchen to drain the water from the dike. My inspection this date revealed that the dike was full of water but has turned to ice. I contacted Doug Kitchen at 1:13 PM and advised him to pull the power lines off the ground. Mr. Kitchen informed me that the power is not on but that they will be picked up and put on their post next week. Time of inspection: -2 degrees F, Sunny |
1550763050 | 2019-02-21 | Production Wells | No Violations | I conducted a follow-up inspection to check if Doug Kitchen pulled the electric service lines off the ground. My inspection revealed that the electric lines have been pulled off the ground for this well as well as the electric lines on top of the hill. The landowner Tim Jubach has complained about the electric lines hanging from trees and vegetation throughout the property. Doug Kitchen has agreed to set poles and get the electric lines off the trees. The violation will be resolved when the electric lines are pulled from the trees and vegetation. Time of inspection: 9:00 AM. Weather: 35 degrees F, Sunny |
1558167378 | 2009-12-10 | Annular Disposal | No Violations | A follow-up inspection was conducted with Mr. Robert Stonerock, South Region Oil & Gas Supervisor. Reviewed and discussed location and source of illegal brine disposal onto ground surface as previously noted. Furthermore, reviewed cleanup that had been performed on-site since this time. This case will be reviewed by management for further legal action therefore, the Notice of Violation will be left open. Note: light snow cover at time of inspection. |
1561986327 | 2019-7-1 0:00:0 | PW | No Violations | 0.50 |
1571917080 | 2019-10-18 0:00 | PW | No Violations | 0.20 |
1581737402 | 2020-2-14 0:00: | PW | No Violations | 1.70 |
1582222719 | 2020-2-20 0:00: | PW | No Violations | 0.20 |
1895269874 | 2009-11-05 | Annular Disposal | No Violations | A follow-up inspection was conducted with Dan Goins. The well status remains the same as AD remains connected to the well. Called Mr. Doug Kitchen at his office at 9:31 am. Instructed Mr. Kitchen to remove connection today. He states that Mr. Ron McBride is on his way. Mr. Mcbride arrived at location and disconnected the AD line at the well. The valve is closed. Mr. McBride states that he will also close the valve at 100 bbl on the hill and that its empty. Mr. McBride was asked about the AD line from location on hill (near ERP). He states that both him and Doug believe there is a potential for 100 bbl to drain to both Permit 2218 and Permit 2219. Further states they are unsure of setup because it was like this when they bought the wells. Explained to Mr. McBride the areas that will require P&C removal (P&C had been buried). |
2000572575 | 2004-11-26 | Annular Disposal | No Violations | Follow-up on NOV, In-Compliance. |
2000579079 | 2004-07-20 | Annular Disposal | No Violations | Follow-up on NOV, Non-Complaince, met with Ronnie McBride at site, showed him where to start clean up. |
2007154601 | 2004-07-13 | Annular Disposal | No Violations | AD test on well, well passed test. |
2047931317 | 2009-09-08 | Annular Disposal | No Violations | A follow-up inspection to Revocation Order revealed that annular disposal has not been disconnected or tested. |
244179378 | 2019-1-7 0:00:0 | PW | No Violations | 1.30 |
249650400 | 2019-4-29 0:00: | AD | No Violations | |
258160004 | 2016-5-4 0:00:0 | AD | No Violations | |
262978571 | 2004-6-8 0:00:0 | AD | No Violations | |
277682018 | 2004-7-28 0:00: | AD | No Violations | |
368421645 | 2009-11-13 0:00 | AD | No Violations | |
469117952 | 2004-5-13 0:00: | AD | No Violations | |
807689039 | 2015-4-10 0:00: | AD | No Violations | 4.00 |
99529558 | 2006-10-18 0:00 | AD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0218371379 | US-OH-122171 | 2004-05-05 | Well operation causing pollution and contamination | |
0218371379 | US-OH-122172 | 2004-05-05 | Failure to keep SPCC dike/pit free of brine and other wastes | |
0249650400 | US-OH-122569 | 2019-05-09 | Failure to file Annular Disposal Report | |
0258160004 | US-OH-122659 | 2017-05-22 | 9-3-11(F)2 | Failure to file Annular Disposal Report |
0469117952 | US-OH-125086 | 2004-05-17 | Failure to properly bury pipelines | |
1237211278 | US-OH-106336 | 2018-08-03 | Failure to file Annular Disposal Report | |
1256837408 | US-OH-106922 | 2009-10-29 | Well operation causing pollution and contamination | |
1256837408 | US-OH-106923 | 2009-10-29 | Leaking brine pipeline | |
1256837408 | US-OH-106924 | 2009-10-29 | Brine disposal system not liquid tight | |
1256837408 | US-OH-106925 | 2009-10-29 | Well not equipped to prevent escape of oil and/or gas | |
1256837408 | US-OH-106926 | 2009-11-02 | Failure to legibly identify well | |
1256837408 | US-OH-106927 | 2009-10-29 | Unlawful method of storage or disposal of brine or other wastes | |
1256837408 | US-OH-106928 | 2009-10-29 | Failure to keep SPCC dike/pit free of brine and other wastes | |
1256837408 | US-OH-106929 | 2009-10-29 | Unlawful use of pit for temporary storage of brine or other wastes | |
1256837408 | US-OH-106930 | 2009-10-29 | Use of pit of dike for ultimate disposal of brine or other wastes |
For data sources see[9]