34-163-20614

Well Details

Well ID: 34-163-20614
Loading map...
County: Vinton
Municipality:
Operator Name: HOCKING HILLS ENERGY WELL SERV
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1981-06-22
Unconventional: No
Configuration: Vertical
Well Status: Final Restoration
Violations: 0
Latitude: 39.23682778
Longitude: -82.31947663

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1984-0 0.0 350.0
1985-0 0.0 160.0
1987-0 0.0 485.0
1988-0 0.0 316.0
1989-0 0.0 77.0
1990-0 0.0 450.0
1991-0 0.0 225.0
1992-0 0.0 196.0
1993-0 0.0 145.0
1994-0 0.0 106.0
1995-0 0.0 56.0
1996-0 0.0 20.0
1997-0 0.0 0.0
1998-0 0.0 0.0
1999-0 0.0 0.0
2000-0 0.0 0.0
2001-0 0.0 0.0
2002-0 0.0 0.0
2003-0 0.0 0.0
2004-0 0.0 0.0
2005-0 0.0 0.0
2006-0 0.0 0.0
2007-0 0.0 0.0
2008-0 0.0 0.0
2009-0 0.0 0.0
2010-0 0.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1045460274 2005-10-03 Non-Compliance, well still idle. Phone Call
-1045460274 2005-10-03 Non-Compliance, well still idle. Compliance Notice
-1045460274 2005-10-03 Non-Compliance, well still idle. Phone Call
-1045460274 2005-10-03 Non-Compliance, well still idle. Field Visit or Inspection
-1045460274 2005-10-03 Non-Compliance, well still idle. Compliance Notice
-1045460274 2005-10-03 Non-Compliance, well still idle. Compliance Notice
-1045460274 2005-10-03 Non-Compliance, well still idle. Phone Call
-1045460274 2005-10-03 Non-Compliance, well still idle. Compliance Notice
-1045460274 2005-10-03 Non-Compliance, well still idle. Compliance Notice
1104942620 2005-01-05 Follow-up on NOV, In-Compliance
-1123150468 2010-09-17 Attempts made to speak with Mr. Doug Kithen by telephone regarding plugging requirements were unsuccessful. Therefore, Mr. Ron McBride with Chieftain Energy was advised of requirements at 9:30 a.m.
-1141338772 2008-02-05 A follow-up inspection revealed that the leak from the flow line has not been repaired. The impacted area from this leak is approximately a 10x 15 area. Quantab (high range) reading reached a maximum unit of 10, which greatly exceeds the US EPA Secondary Drinking Water Standard of 250 milligrams per liter. Doug Kitchen was instructed to remove this soil from the site.
1202308848 2008-01-28 A follow-up inspection revealed non-compliance. The well is still idle and no identification was observed. Mr. Doug Kitchen states that the well has been pumping, but had to repair the production line. The broken line was located approximately 150 feet behind the tank battery. At the time of the inspection, the production line (black plastic) was found to be leaking. The leak is a slow constant drip. Mr. Kitchen was informed by telephone to repair this line immediately and remove contamination and pollution.
-1212923258 2004-10-07 Follow-up on NOV, non-compliance, violations not corrected, well still idle, spoke with Doug Kitchen on the phone, he is hoping Paul Grim will take over well.
1247957173 2014-04-10 This is a follow-up/ final restoration for a piece of equipment left at the well site. During my inspection I was unable to find anything. The violation was from 2011. The well is in-compliance and the final restoration meets 1509.072.
1269i1022 2002-05-06 Follow-up on NOV, In-Compliance.
1269i845 2002-03-06 An inspection of the well revealed there is No ID at the well or tank battery, oily soil around well head, oil and oily soil in dike of tank battery. Dike does not meet requirements, not large enough. Dike size is 30x40x1, will hold 195 bbls of fluid, dike has 3-100bbl, 1-200bbl tanks. NEED FULL ID AT THE WELL AND TANK BATTERY, CLEAN UP ALL OIL, AND OILY SOIL AT WELL AND DIKE OF TANK BATTERY. BUILD A DIKE TO HOLD AT LEAST 220BBLS OF FLUID.
1269i908 2002-03-26 Follow-up, Non-Compliance, met with Doug Kitchen.
1319630113 2011-10-24 An inspection of the final restoration revealed an electric pole with service boxes on it is present on site. Pole needs to be removed from site. Mr. Doug Kitchen from Chieftain energy was called on Tuesday 10/25/11 at 9:30 am and notified of the problem. Mr. Kitchen agreed to comply next week.
-1410153597 2008-10-03 An inspection revealed that valves are open at the well. Tanks empty at time of inspection.
-1575008394 2008-04-03 Met with complainant to discuss issues with associated well. A follow-up inspection revealed non-compliance at the tank battery. Chieftain Energy had been instructed to remove C&P. It was noted that C&P has been buried. The company was contacted by telephone and informed of inspection results.
-1721322875 2008-04-25 Informed Doug Kitchen to remove oily soil inside dike. Mr. Kitchen was also instructed that once the cleanup has been performed, the 100bbl tank will need to be evaluated for leaks.
-179469770 2008-02-19 A follow-up inspection revealed that the flow line has been repaired. C&P has been removed.
-1800544467 2006-01-11 Follow-up on NOV, IN-COMPLIANCE.
192803336 2008-04-02 A complaint was received alleging that oil has been released from a broken flowline. The owner, Chieftain Energy was contacted and informed of the complaint. An inspection revealed that the oil release was the result of a ruptured flowline. Contamination and pollution was not observed outside the dike. A valve had been closed on a frac tank. As a result, the plastic line ruptured due to pressure. Chieftain Energy had previously stated that this tank was not being utilized. The company was observed on-site performing cleanup. They were instructed to remove oily soil and evaluate 100bbl tank that may contain a small leak underneath and rebuild dike. (1) 100bbl tank was found to be only 40ft from the road. The company states that they will not be utilizing this tank. In addition, the area is limited due a right of way located behind the tank battery.
-2016051595 2008-05-01 An inspection revealed that cleanup has been performed. Met with the landowner to discuss inspection results and concerns.
2026373130 2008-03-18 A follow-up inspection was conducted, in response to landowner complaint alleging that a flow line is leaking. During the inspection, it was noted that a black plastic flow line had separated inside the dike. Small amount of C&P was observed. The line appeared to be routed to the top of a 100 bbl tank. Chieftain Energy was contacted by telephone and stated that the line was not being utilized, but would perform repair and cleanup.
-2037966068 2010-10-01 An inspection revealed that cement remains at the surface inside 4.5 casing. The casing has been cut below grade with no ID plate at time of inspection. Oil remains in the pit containing a liner and will be pumped by Chieftain Energy.
-2063555802 2004-05-26 An inspection of the well revealed the well is idle and has not been producing for several years. According to production records well has not produced since 1998.
-2118123817 2004-09-28 Met with Doug Kitchen and Joe Hoerst, Doug said work was not done, at this time have no plans to plug or produce well.
40269577 2005-10-17 Follow-up on NOV, Non-Compliance, no action to plug or produce.
-428575114 2004-07-19 Follow-up, Non-Compliance.
-45526981 2008-04-28 An inspection revealed non-compliance.
-52994372 2002-03-06 FOLLOW UP TO NOV # 1269i845 An inspection of the well revealed there is No ID at the well or tank battery, oily soil around well head, oil and oily soil in dike of tank battery. Dike does not meet requirements, not large enough. Dike size is 30x40x1, wi
578541966 2008-04-29 Met with Chieftain Energy to discuss related cleanup at tank battery location.
602946304 2010-09-29 Witnessed plugging activity with Mr. Robert Stonerock, South Region Oil & Gas Supervisor.
731034567 2011-10-24 FOLLOW UP TO NOV # 1319630113 An inspection of the final restoration revealed an electric pole with service boxes on it is present on site. Pole needs to be removed from site. Mr. Doug Kitchen from Chieftain energy was called on Tuesday 10/25/11 at 9:30 am and notified of the problem. Mr. Kitchen agreed to comply next week.
752225641 2007-10-17 A complaint was received by the Division of Mineral Resources Management alleging that this well was idle. An inspection revealed that the well does not appear to be producing and identification is incomplete. Production records indicate that the last year of production was 1996. Landowner has not received any monies for several years. No electric for the motor on the well. The well owner, Mr. Doug Kitchen, states that he has not been producing this well and to send him a NOV.
-889160327 2005-08-15 An inspection of the well revealed the well has been producing since 1996. Landowner has not received any monies for several years. No electric for motor on well.
939628894 2008-04-18 A follow-up inspection revealed non-compliance. C&P has not been removed.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.