If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-151-21886 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
County: Stark | |
Municipality: | |
Operator Name: ARVILLA OILFIELD SERVICES LLC | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1968-08-15 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Final Restoration | |
Violations: 0 | |
Latitude: 40.68768036 | |
Longitude: -81.28426984 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1994-0 | 0.0 | 195.0 | ||||
1995-0 | 0.0 | 297.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
1022265140 | 2007-06-27 | The system was not running at the time of the inspection. There were no violations at the wellhead or at the brine pits. | Field Visit or Inspection | |||
-102874261 | 2006-08-30 | The system was running at the time of the inspection. There were no violations at the wellhead or at the tank battery. | ||||
-103631658 | 2005-03-22 | The system was running at the time of the inspection. NO VIOLATIONS. | ||||
1038823789 | 2010-05-13 | There was no decommissioning activity observed at the site today. | ||||
1054684784 | 2003-06-03 | Inspected facility and injection well. NO VIOLATIONS. Did not check injection or annulus pressure. | ||||
1068692654 | 2003-11-12 | System was running. NO VIOLATIONS. | ||||
1074196774 | 2009-05-28 | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The injection line is disconnected from the wellhead. The clean up of the facility that was requested of Arvilla has not been completed. | ||||
-1110881596 | 2010-06-04 | There was no activity on the site today. Plugging will begin on 6-7-10. | ||||
-11274908 | 2010-06-14 | The well is still flowing back. Tubing pressure is 100 psi. Arvilla will kill the well so that they can unseat the packer. | ||||
1192046293 | 2007-10-10 | I met with Tom Tomastik, Jeff Fry, Bob McVicker (Mac Oilfield Services), John McCall, Becky Smith (Arvilla) and Ken Parsons (Arvilla) at the facility. Bob McVicker is evaluating the facility for potential purchase by John McCall. A brine leak was observed on the hillside located north-northeast of the injection well head. It is probably coming from a leak in the lower brine pit. Arvilla will drain the lower brine pit, repair the leak, and remove all brine contaminated soil for landfill disposal. | ||||
1196720586 | 2007-12-03 | Arvilla is hauling brine and sludge out of the lower pit for disposal. SUNPRO is supervising the sludge removal. The brine is going to one of Arvilla's injection wells in the southern region. The sludge is going to American Landfill in Waynesburg. I met with Kerry of Sunpro and with Ken Parsons and John Herstine of Arvilla. Sludge removal will continue tomorrow. | ||||
1196971818 | 2007-12-05 | There was no activity at the site today. The lower pit level has been lowered since the last inspection on 12-3-2007. | ||||
1234382308 | 2009-02-10 | I met with Jim and Brenda Hawkins (J-Hawk Water Service), John Herstine (Arvilla), and Kevin Reaman (KU Resources) at the site to discuss the Phase I Site Assessment of the property and the potential purchase of the property by J-Hawk Water Service. During the meeting, John Herstine stated that Arvilla has not repaired the leak in the lower pit. They have only lowered the level of the brine to below the level of the leak. J-Hawk will purchase the property in as is condition if the deal is agreed. | ||||
1256323233 | 2009-10-23 | I met on the location today with Matt Johnson and Dave Michels of Arvilla. This well will be plugged and abandoned and the facility will be decommissioned. | ||||
1256734370 | 2009-10-27 | Arvilla has equipment on the location, moving tanks and making room for the service rig. I met with Matt Johnson and John Herstine on the site and discussed their plan of operation. | ||||
-1261705232 | 2008-03-10 | I received a call from Tom Tomastik regarding a reported leak (from Bob McVicker) at the injection well. I met with John Herstine (Arvilla), cell # 740-584-1787, at the site. The filter canister located near the wellhead was leaking fresh water. The leak had sprayed out 3 feet from the canister. John repaired the leaking gasket and shut in the filter canister. This facility is not in operation. The repair work at the lower pit has not been completed. | ||||
1264182971 | 2010-01-21 | The injection pump, the pump shed, and the concrete unloading pad have been removed. | ||||
1267121384 | 2007-10-30 | The access gates to the injection well and to the brine pits were closed and locked. The requested repair on the seepage on the hillside located below the lower brine pit has not been done. A Cat (D-4) bulldozer is parked near the seepage area. | ||||
1277495084 | 2010-06-25 | Formation Cementing pumped the Berea/8-5/8 and surface plugs. Arvilla's service rig rigged down. | ||||
1281578401 | 2010-08-10 | I met with John Herstine (Arvilla) and discussed the final restoration of the site. I called Matt Johnson (Arvilla) regarding the completion of the final restoration. | ||||
1283307250 | 2010-08-31 | There was no activity on the site at the time of the inspection. | ||||
1288i124 | 2001-10-29 | Injection : 950 ; Annulus : 760 ; No violations at this time . | ||||
1288i262 | 2002-01-18 | Injection : 1120 ; Annulus : 750 ; Last inspection on 10 / 29 / 01 . No violations at this time . | ||||
1288i286 | 2002-02-20 | Injection : 970 ; Annulus : 750 ; Last inspection : 01 / 18 / 02 . No violations at this tme . | ||||
1288i33 | 2001-09-13 | injection :1130 ; annulus: 610 ; No violations at this time . Last inspection on June 18th , 2001. | ||||
1288i374 | 2002-03-19 | Injection : 1170 ; Annulus : 1300 ; Last inspection on 02 / 20 / 02 . No violations at this time . | ||||
1288i517 | 2002-04-23 | Injection : 1000 ; Annulus : 1060 ; Last inspection on 03 / 19 / 02 . No violations at this time . | ||||
-129536685 | 2010-01-29 | There was no activity on the site. Arvilla was not working here today. | ||||
1297908827 | 2010-09-02 | I met with Darrell Satterfield (Select Energy) on the location. The service rig has been moved to the upper pit area and will be driven back to West Virginia next week. Select is closing the plugging pit today and will fill in around the 8-5/8 dia casing and tack weld a plate on top. | ||||
1344510107 | 2010-10-26 | This well was plugged and abandoned on 6-25-2010. The entire facility has been decommissioned. The N.O.V. is RESOLVED. | ||||
-1371596962 | 2007-12-18 | The injection pump was not running at the time of the inspection. The lower brine pit has been pumped down to expose the transfer line connection for repairs. Arvilla has mobilized their equipment on the location for the necessary repairs and site remediation. | ||||
1372060957 | 2010-10-05 | I met on the location with Kyle (consultant), Wolfgang (Sunpro), Greg, Roger, and John McCall to review the reclamation. The upper pits and pit liners have been removed and the location is graded. It will be seeded on Thursday. The old Quaker State tank has been emptied and is being cut up for scrap. | ||||
-1423041013 | 2010-03-29 | This facility is being decommissioned. The injection well will be plugged in the spring of 2010. | ||||
-1427678883 | 2010-08-24 | Met with Select Energy Services personnel (Hal McSpadden, Steve Enos, Darrell Satterfield) and discussed The Final Restoration of the site. | ||||
-1446316802 | 2010-09-09 | This well was plugged and abandoned on 6-25-2010. The plugging pit is closed and the former wellhead area has been backfilled and graded. The Final Restoration of the site is still in progress. | ||||
1539650122 | 2005-11-09 | The system was running at the time of the inspection. NO VIOLATIONS. | ||||
-1583749761 | 2009-11-13 | Arvilla ran a new on/off tool into the well with tubing. The packer was not disturbed and is still set at 4484'. An MIT was conducted today. Starting pressure 1410 psi at 0924 hrs; ending pressure 1390 psi at 0944 hrs. MIT PASSED. | ||||
1733558993 | 2010-06-18 | The service rig finished pulling the 2-3/8 dia tubing. The wellhead is packed off. A cement bond log will be run on Monday. | ||||
-1779184963 | 2010-06-24 | Timco hit an obstruction in the 4-1/2 dia casing at 3136' while going into the hole to shoot off the casing. Arvilla ran into the hole with there tools and the obstruction was still there. Timco went back in the hole and shot at 3073'. Formation Cementing pumped a shale plug from 3040' up to 2790'. | ||||
1808909078 | 2005-02-04 | The system was running at the time of the inspection. NO VIOLATIONS. | ||||
-1867514074 | 2010-10-08 | Sunpro has removed all of the metal from the site. The 2 roll off boxes containing oil stained soils and other site decommissioning debris will be removed later today. Arvilla's service rig and an empty 300-barrel frac tank are still on the upper location and need to be removed. | ||||
1877425154 | 2008-06-12 | The injection system was not running at the time of the inspection. The clean up of the facility that had been requested has not been completed. | ||||
1892667310 | 2009-11-03 | Arvilla's service rig was on the location today. I talked to Dave Michels, Arvilla's rig operator. He said that he will inform me when they are going to run in with the new packer and when they will attempt to do a MIT. | ||||
1897731392 | 2010-10-26 | Arvilla's service rig and the empty 300-barrel frac tank have been removed. Grass is starting to emerge on the former upper pit area. The former wellhead area has been rough graded. The property owner, John McCall, is satisfied with Arvilla's reclamation on his property. I will not pass the Final Restoration until vegetation is established on the former upper pit area. | ||||
191111569 | 2002-10-18 | Routine inspection revealed no violations at this time . | ||||
-1949270532 | 2010-09-29 | I met with Hal McSpadden (Select Energy) and Kyle Combest (environmental consultant) at the site. Kyle will be overseeing the Final Restoration at the site. Sunpro is cleaning out the upper pits today. The liners will be pulled out and taken to American Landfill in Waynesburg for disposal. | ||||
1978693952 | 2007-09-26 | The injection pump was not running at the time of the inspection. There were no violations at the wellhead or at the brine pits. This facility is up for sale. | ||||
2000912134 | 2013-07-12 | No indication of well equipment, or tank battery. Access road still in use for other producing wells and tank batteries. | ||||
-2045226942 | 2010-06-08 | The injection well has 110 psi on the injection tubing and is flowing back into a 500 bbl frac tank. The service rig crew is monitoring the flow back. | ||||
-2059684469 | 2004-01-06 | Repairing the 2 dia. flowline that was encased inside the 4 dia. flowline. Met with Bill Westphal of Belden & Blake. | ||||
-213329329 | 2009-09-04 | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The injection line is disconnected from the wellhead. The clean up of the facility that was requested of Arvilla has not been completed. | ||||
2146417780 | 2010-06-22 | Formation Cementing pumped the combined Newburg and packer isolation plug thru tubing.. | ||||
226102839 | 2004-09-21 | NO VIOLATIONS. The system was running at the time of the inspection. | ||||
258997434 | 2008-12-18 | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The clean up of the facility that was requested has not been completed. A Chief's Order has been issued to Arvilla. | ||||
320714008 | 2007-03-13 | The system was running at the time of the inspection. There were no violations at the wellhead or at the brine pits. | ||||
-325803043 | 2010-06-17 | Unseated the 2-3/8 dia tubing from the packer and started pulling the tubing. The rig chain broke. Will repair the chain and continue pulling the tubing tomorrow. | ||||
333630213 | 2008-03-21 | The facility was not running at the time of the inspection and is shut down until the lower brine pit is repaired. | ||||
-368206360 | 2010-06-21 | Ran a cement bond log and located the top of cement at 3748'. | ||||
-373378910 | 2006-05-23 | The system was running at the time of the inspection. There were no violations at the wellhead or at the lined brine pits. | ||||
-376786703 | 2006-03-02 | The injection pump was running at the time of the inspection. No Violations at WH or at pits. | ||||
379426048 | 2008-09-25 | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The clean up of the facility that was requested has not been completed. A Chief's Order has been issued to Arvilla. | ||||
449625893 | 2010-06-23 | The service rig crew will change out pipe trailers, dig out the 8-5/8 dia wellhead, and screw on the 4-1/2 dia casing pulling sub. | ||||
-458872098 | 2004-06-25 | The system was running at the time of the inspection. NO VIOLATIONS. | ||||
-467665008 | 2005-06-28 | NO VIOLATIONS. The disposal facility was running at the time of the inspection. | ||||
-529066071 | 2004-03-25 | The system was not running at the time of the inspection. The injection pump was being repaired. | ||||
547911037 | 2010-08-17 | There was no activity on the site today. | ||||
575910565 | 2010-06-10 | There was no activity on the site at the time of the inspection. | ||||
-582267085 | 2010-10-07 | The former upper pit area is seeded and mulched. The Quaker State stock tank has been cut up. The decommissioning of the facility will be completed tomorrow. | ||||
-665696982 | 2002-10-18 | Routine inspection revealed no violations at this time . | ||||
-668955777 | 2008-01-30 | There was no evidence of seepage along the hillside below the lower brine pit. The soil in the drainage ditch that is located below the former seep appears to be excavated out. Arvilla's trucks are no longer on the site. I will call Ken Parsons (Arvilla) regarding the status of the site. | ||||
713579936 | 2007-11-21 | The brine leak has not been repaired. The hillside was not seeping brine and there was no ponded brine in the drainage ditch. The upper pit is lowered to approximately 5 feet. The lower pit is lowered to approximately 3 feet. I informed John McCall and Tom Tomastik. Tom Tomastik will contact Arvilla in West Virginia regarding the remediation. | ||||
-834607999 | 2010-06-29 | The casing trailer is being moved off of the location today. | ||||
894362062 | 2009-04-01 | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The injection line is disconnected from the wellhead. A MIT was conducted last month by Jim Hawkins to evaluate the well for possible purchase. The MIT failed. The clean up of the facility that was requested of Arvilla has not been completed. A Chief's Order has been issued to Arvilla. | ||||
900444640 | 2010-01-04 | Arvilla's service rig, 2 bull dozers, and a backhoe are on the location. A plugging pit has been dug and lined. Nobody was working at the site at the time of my inspection. | ||||
943833021 | 2009-11-06 | The service rig was not working today. I called Matt Johnson. The tubing has been tripped out of the hole. Holes were found in the 4th joint of tubing from the top. The bad joint of tubing will be replaced and the tubing will be tripped back into the hole on 11-9-09 and pressure tested every 500'. An MIT may be conducted on 11-10-09. |
For data sources see[2]