{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.68,"lon":-81.28,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Sandy Township | |
Operator Name: ARVILLA OILFIELD SERVICES LLC | |
Well Pad ID: | |
Farm/Lease Name: MCCALL J {SWIW # 2) | |
License Status: Final Restoration | |
License Date: 2009-11-09 | |
Spud Date: 1968-08-15 | |
Spud Drilling Contractor: H & M DRILLING | |
Final Drill Date: 1968-08-21 | |
Well Total Depth: 5079.00 ft | |
Configuration: Vertical | |
Latitude: 40.680000 | |
Longitude: -81.280000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1968-08-15 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
Completed | 1968-08-21 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
Reached Total Depth | 1968-08-21 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
Conversion to Injector | 1972-01-28 | |
CO | 1972-02-13 | 133 QUAKER STATE OIL REF CORP GeoDate 2/13/72 |
Unknown | 1972-02-13 | Issued Date 1/28/72 Expired Date 1/27/73 Acres 0000000 Tool Type Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000 |
First Injection | 1972-05-26 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
CO | 1995-10-18 | 182 BELDEN & BLAKE CO GeoDate 2/13/72 |
Annulus Pressure Monitoring Approved | 1996-03-25 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
Change of Owner | 2004-07-14 | Operator changed from 4930, CANTON OIL & GAS COMPANY to 7666, ARVILLA OILFIELD SERVICES LLC |
APP | 2009-11-09 | Proposed Formations:QUEENSTON, Issued Date:11/9/2009, Expired Date:11/9/2010 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Last Compliance Report | 2009-11-16 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
Plugged/Abandoned | 2010-06-25 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
Construction Permit Expires | 2010-11-09 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
Record Last Modified | 2013-08-06 | NO EVIDENCE THAT CLINTON EVER PLUGGED. CONVERTED TO S.W.D.W. 2/10/1972 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-08 | 4549 | 4619 | 1 |
4914 | 5013 | 18 | |
1999-08-11 | 4914 | 5013 | 18 |
4549 | 4619 | 1 | |
4549 | 4619 | 1 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 57490 Gal | 75000 | FRACTURED WITH 57490 GALLONS OF WATER AND 75000 LBS OF 20/40 SAND. | ||
ACID | 15 | 1000 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1994 | QUAKER STATE OIL REF CORP | 0.00 | 195.00 | 365 |
1995 | BELDEN & BLAKE CORPORATION | 0.00 | 297.00 | 366 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1994 | QUAKER STATE OIL REF CORP | Brine | 775 | 365 |
1995 | BELDEN & BLAKE CORPORATION | Brine | 0 | 366 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-102874261 | 2006-8-30 0:00: | SW | No Violations | |
-103631658 | 2005-3-22 0:00: | SW | No Violations | |
-1110881596 | 2010-6-4 0:00:0 | SW | No Violations | |
-11274908 | 2010-6-14 0:00: | SW | No Violations | |
-1261705232 | 2008-3-10 0:00: | SW | No Violations | |
-129536685 | 2010-1-29 0:00: | PB | No Violations | |
-1371596962 | 2007-12-18 0:00 | SW | No Violations | |
-1423041013 | 2010-3-29 0:00: | SW | No Violations | |
-1427678883 | 2010-8-24 0:00: | SW | No Violations | |
-1446316802 | 2010-9-9 0:00:0 | FR | No Violations | |
-1583749761 | 2009-11-13 0:00 | SW | No Violations | |
-1779184963 | 2010-6-24 0:00: | PB | No Violations | |
-1867514074 | 2010-10-8 0:00: | FR | No Violations | |
-1949270532 | 2010-9-29 0:00: | FR | No Violations | |
-2045226942 | 2010-6-8 0:00:0 | SW | No Violations | |
-2059684469 | 2004-1-6 0:00:0 | SW | No Violations | |
-213329329 | 2009-9-4 0:00:0 | SW | No Violations | |
-325803043 | 2010-6-17 0:00: | PB | No Violations | |
-368206360 | 2010-6-21 0:00: | PB | No Violations | |
-373378910 | 2006-5-23 0:00: | SW | No Violations | |
-376786703 | 2006-3-2 0:00:0 | SW | No Violations | |
-458872098 | 2004-6-25 0:00: | SW | No Violations | |
-467665008 | 2005-6-28 0:00: | SW | No Violations | |
-529066071 | 2004-3-25 0:00: | SW | No Violations | |
-582267085 | 2010-10-7 0:00: | FR | No Violations | |
-665696982 | 2002-10-18 0:00 | SW | No Violations | |
-668955777 | 2008-1-30 0:00: | SW | No Violations | |
-834607999 | 2010-6-29 0:00: | FR | No Violations | |
0001288i33 | 2001-09-13 | Salt Water Injection Well | No Violations | injection :1130 ; annulus: 610 ; No violations at this time . Last inspection on June 18th , 2001. |
0011274908 | 2010-06-14 | Salt Water Injection Well | No Violations | The well is still flowing back. Tubing pressure is 100 psi. Arvilla will kill the well so that they can unseat the packer. |
001288i124 | 2001-10-29 | Salt Water Injection Well | No Violations | Injection : 950 ; Annulus : 760 ; No violations at this time . |
001288i262 | 2002-01-18 | Salt Water Injection Well | No Violations | Injection : 1120 ; Annulus : 750 ; Last inspection on 10 / 29 / 01 . No violations at this time . |
001288i286 | 2002-02-20 | Salt Water Injection Well | No Violations | Injection : 970 ; Annulus : 750 ; Last inspection : 01 / 18 / 02 . No violations at this tme . |
001288i374 | 2002-03-19 | Salt Water Injection Well | No Violations | Injection : 1170 ; Annulus : 1300 ; Last inspection on 02 / 20 / 02 . No violations at this time . |
001288i517 | 2002-04-23 | Salt Water Injection Well | No Violations | Injection : 1000 ; Annulus : 1060 ; Last inspection on 03 / 19 / 02 . No violations at this time . |
0102874261 | 2006-08-30 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. There were no violations at the wellhead or at the tank battery. |
0103631658 | 2005-03-22 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. NO VIOLATIONS. |
0129536685 | 2010-01-29 | Plug / Plug Back | No Violations | There was no activity on the site. Arvilla was not working here today. |
0191111569 | 2002-10-18 | Salt Water Injection Well | No Violations | Routine inspection revealed no violations at this time . |
0213329329 | 2009-09-04 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The injection line is disconnected from the wellhead. The clean up of the facility that was requested of Arvilla has not been completed. |
0226102839 | 2004-09-21 | Salt Water Injection Well | No Violations | NO VIOLATIONS. The system was running at the time of the inspection. |
0258997434 | 2008-12-18 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The clean up of the facility that was requested has not been completed. A Chiefs Order has been issued to Arvilla. |
0320714008 | 2007-03-13 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. There were no violations at the wellhead or at the brine pits. |
0325803043 | 2010-06-17 | Plug / Plug Back | No Violations | Unseated the 2-3/8 dia tubing from the packer and started pulling the tubing. The rig chain broke. Will repair the chain and continue pulling the tubing tomorrow. |
0333630213 | 2008-03-21 | Salt Water Injection Well | No Violations | The facility was not running at the time of the inspection and is shut down until the lower brine pit is repaired. |
0368206360 | 2010-06-21 | Plug / Plug Back | No Violations | Ran a cement bond log and located the top of cement at 3748. |
0373378910 | 2006-05-23 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. There were no violations at the wellhead or at the lined brine pits. |
0376786703 | 2006-03-02 | Salt Water Injection Well | No Violations | The injection pump was running at the time of the inspection. No Violations at WH or at pits. |
0379426048 | 2008-09-25 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The clean up of the facility that was requested has not been completed. A Chiefs Order has been issued to Arvilla. |
0449625893 | 2010-06-23 | Plug / Plug Back | No Violations | The service rig crew will change out pipe trailers, dig out the 8-5/8 dia wellhead, and screw on the 4-1/2 dia casing pulling sub. |
0458872098 | 2004-06-25 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. NO VIOLATIONS. |
0467665008 | 2005-06-28 | Salt Water Injection Well | No Violations | NO VIOLATIONS. The disposal facility was running at the time of the inspection. |
0529066071 | 2004-03-25 | Salt Water Injection Well | No Violations | The system was not running at the time of the inspection. The injection pump was being repaired. |
0547911037 | 2010-08-17 | Final Restoration | No Violations | There was no activity on the site today. |
0575910565 | 2010-06-10 | Salt Water Injection Well | No Violations | There was no activity on the site at the time of the inspection. |
0582267085 | 2010-10-07 | Final Restoration | No Violations | The former upper pit area is seeded and mulched. The Quaker State stock tank has been cut up. The decommissioning of the facility will be completed tomorrow. |
0665696982 | 2002-10-18 | Salt Water Injection Well | No Violations | Routine inspection revealed no violations at this time . |
0668955777 | 2008-01-30 | Salt Water Injection Well | No Violations | There was no evidence of seepage along the hillside below the lower brine pit. The soil in the drainage ditch that is located below the former seep appears to be excavated out. Arvillas trucks are no longer on the site. I will call Ken Parsons (Arvilla) regarding the status of the site. |
0713579936 | 2007-11-21 | Salt Water Injection Well | No Violations | The brine leak has not been repaired. The hillside was not seeping brine and there was no ponded brine in the drainage ditch. The upper pit is lowered to approximately 5 feet. The lower pit is lowered to approximately 3 feet. I informed John McCall and Tom Tomastik. Tom Tomastik will contact Arvilla in West Virginia regarding the remediation. |
0834607999 | 2010-06-29 | Final Restoration | No Violations | The casing trailer is being moved off of the location today. |
0894362062 | 2009-04-01 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The injection line is disconnected from the wellhead. A MIT was conducted last month by Jim Hawkins to evaluate the well for possible purchase. The MIT failed. The clean up of the facility that was requested of Arvilla has not been completed. A Chiefs Order has been issued to Arvilla. |
0900444640 | 2010-01-04 | Plug / Plug Back | No Violations | Arvillas service rig, 2 bull dozers, and a backhoe are on the location. A plugging pit has been dug and lined. Nobody was working at the site at the time of my inspection. |
0943833021 | 2009-11-06 | Salt Water Injection Well | No Violations | The service rig was not working today. I called Matt Johnson. The tubing has been tripped out of the hole. Holes were found in the 4th joint of tubing from the top. The bad joint of tubing will be replaced and the tubing will be tripped back into the hole on 11-9-09 and pressure tested every 500. An MIT may be conducted on 11-10-09. |
1022265140 | 2007-06-27 | Salt Water Injection Well | No Violations | The system was not running at the time of the inspection. There were no violations at the wellhead or at the brine pits. |
1038823789 | 2010-05-13 | Salt Water Injection Well | No Violations | There was no decommissioning activity observed at the site today. |
1054684784 | 2003-06-03 | Salt Water Injection Well | No Violations | Inspected facility and injection well. NO VIOLATIONS. Did not check injection or annulus pressure. |
1068692654 | 2003-11-12 | Salt Water Injection Well | No Violations | System was running. NO VIOLATIONS. |
1074196774 | 2009-05-28 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. The site is closed and is not in operation. The injection line is disconnected from the wellhead. The clean up of the facility that was requested of Arvilla has not been completed. |
1110881596 | 2010-06-04 | Salt Water Injection Well | No Violations | There was no activity on the site today. Plugging will begin on 6-7-10. |
1192046293 | 2007-10-10 | Salt Water Injection Well | Violations Noted | I met with Tom Tomastik, Jeff Fry, Bob McVicker (Mac Oilfield Services), John McCall, Becky Smith (Arvilla) and Ken Parsons (Arvilla) at the facility. Bob McVicker is evaluating the facility for potential purchase by John McCall. A brine leak was observed on the hillside located north-northeast of the injection well head. It is probably coming from a leak in the lower brine pit. Arvilla will drain the lower brine pit, repair the leak, and remove all brine contaminated soil for landfill disposal. |
1196720586 | 2007-12-03 | Salt Water Injection Well | No Violations | Arvilla is hauling brine and sludge out of the lower pit for disposal. SUNPRO is supervising the sludge removal. The brine is going to one of Arvillas injection wells in the southern region. The sludge is going to American Landfill in Waynesburg. I met with Kerry of Sunpro and with Ken Parsons and John Herstine of Arvilla. Sludge removal will continue tomorrow. |
1196971818 | 2007-12-05 | Salt Water Injection Well | No Violations | There was no activity at the site today. The lower pit level has been lowered since the last inspection on 12-3-2007. |
1234382308 | 2009-02-10 | Salt Water Injection Well | No Violations | I met with Jim and Brenda Hawkins (J-Hawk Water Service), John Herstine (Arvilla), and Kevin Reaman (KU Resources) at the site to discuss the Phase I Site Assessment of the property and the potential purchase of the property by J-Hawk Water Service. During the meeting, John Herstine stated that Arvilla has not repaired the leak in the lower pit. They have only lowered the level of the brine to below the level of the leak. J-Hawk will purchase the property in as is condition if the deal is agreed. |
1256323233 | 2009-10-23 | Salt Water Injection Well | No Violations | I met on the location today with Matt Johnson and Dave Michels of Arvilla. This well will be plugged and abandoned and the facility will be decommissioned. |
1256734370 | 2009-10-27 | Salt Water Injection Well | No Violations | Arvilla has equipment on the location, moving tanks and making room for the service rig. I met with Matt Johnson and John Herstine on the site and discussed their plan of operation. |
1261705232 | 2008-03-10 | Salt Water Injection Well | No Violations | I received a call from Tom Tomastik regarding a reported leak (from Bob McVicker) at the injection well. I met with John Herstine (Arvilla), cell # 740-584-1787, at the site. The filter canister located near the wellhead was leaking fresh water. The leak had sprayed out 3 feet from the canister. John repaired the leaking gasket and shut in the filter canister. This facility is not in operation. The repair work at the lower pit has not been completed. |
1264182971 | 2010-01-21 | Plug / Plug Back | No Violations | The injection pump, the pump shed, and the concrete unloading pad have been removed. |
1267121384 | 2007-10-30 | Salt Water Injection Well | No Violations | The access gates to the injection well and to the brine pits were closed and locked. The requested repair on the seepage on the hillside located below the lower brine pit has not been done. A Cat (D-4) bulldozer is parked near the seepage area. |
1277495084 | 2010-06-25 | Plug / Plug Back | No Violations | Formation Cementing pumped the Berea/8-5/8 and surface plugs. Arvillas service rig rigged down. |
1281578401 | 2010-08-10 | Final Restoration | No Violations | I met with John Herstine (Arvilla) and discussed the final restoration of the site. I called Matt Johnson (Arvilla) regarding the completion of the final restoration. |
1283307250 | 2010-08-31 | Final Restoration | No Violations | There was no activity on the site at the time of the inspection. |
1288i124 | 2001-10-29 0:00 | SW | No Violations | |
1288i262 | 2002-1-18 0:00: | SW | No Violations | 1.00 |
1288i286 | 2002-2-20 0:00: | SW | No Violations | 1.00 |
1288i33 | 2001-9-13 0:00: | SW | No Violations | |
1288i374 | 2002-3-19 0:00: | SW | No Violations | 1.00 |
1288i517 | 2002-4-23 0:00: | SW | No Violations | 1.00 |
1297908827 | 2010-09-02 | Final Restoration | No Violations | I met with Darrell Satterfield (Select Energy) on the location. The service rig has been moved to the upper pit area and will be driven back to West Virginia next week. Select is closing the plugging pit today and will fill in around the 8-5/8 dia casing and tack weld a plate on top. |
1344510107 | 2010-10-26 | Salt Water Injection Well | No Violations | This well was plugged and abandoned on 6-25-2010. The entire facility has been decommissioned. The N.O.V. is RESOLVED. |
1371596962 | 2007-12-18 | Salt Water Injection Well | No Violations | The injection pump was not running at the time of the inspection. The lower brine pit has been pumped down to expose the transfer line connection for repairs. Arvilla has mobilized their equipment on the location for the necessary repairs and site remediation. |
1372060957 | 2010-10-05 | Final Restoration | No Violations | I met on the location with Kyle (consultant), Wolfgang (Sunpro), Greg, Roger, and John McCall to review the reclamation. The upper pits and pit liners have been removed and the location is graded. It will be seeded on Thursday. The old Quaker State tank has been emptied and is being cut up for scrap. |
1423041013 | 2010-03-29 | Salt Water Injection Well | No Violations | This facility is being decommissioned. The injection well will be plugged in the spring of 2010. |
1427678883 | 2010-08-24 | Salt Water Injection Well | No Violations | Met with Select Energy Services personnel (Hal McSpadden, Steve Enos, Darrell Satterfield) and discussed The Final Restoration of the site. |
1446316802 | 2010-09-09 | Final Restoration | No Violations | This well was plugged and abandoned on 6-25-2010. The plugging pit is closed and the former wellhead area has been backfilled and graded. The Final Restoration of the site is still in progress. |
1539650122 | 2005-11-09 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. NO VIOLATIONS. |
1583749761 | 2009-11-13 | Salt Water Injection Well | No Violations | Arvilla ran a new on/off tool into the well with tubing. The packer was not disturbed and is still set at 4484. An MIT was conducted today. Starting pressure 1410 psi at 0924 hrs; ending pressure 1390 psi at 0944 hrs. MIT PASSED. |
1733558993 | 2010-06-18 | Plug / Plug Back | No Violations | The service rig finished pulling the 2-3/8 dia tubing. The wellhead is packed off. A cement bond log will be run on Monday. |
1779184963 | 2010-06-24 | Plug / Plug Back | No Violations | Timco hit an obstruction in the 4-1/2 dia casing at 3136 while going into the hole to shoot off the casing. Arvilla ran into the hole with there tools and the obstruction was still there. Timco went back in the hole and shot at 3073. Formation Cementing pumped a shale plug from 3040 up to 2790. |
1808909078 | 2005-02-04 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. NO VIOLATIONS. |
1867514074 | 2010-10-08 | Final Restoration | No Violations | Sunpro has removed all of the metal from the site. The 2 roll off boxes containing oil stained soils and other site decommissioning debris will be removed later today. Arvillas service rig and an empty 300-barrel frac tank are still on the upper location and need to be removed. |
1877425154 | 2008-06-12 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. The clean up of the facility that had been requested has not been completed. |
1892667310 | 2009-11-03 | Salt Water Injection Well | No Violations | Arvillas service rig was on the location today. I talked to Dave Michels, Arvillas rig operator. He said that he will inform me when they are going to run in with the new packer and when they will attempt to do a MIT. |
1897731392 | 2010-10-26 | Final Restoration | No Violations | Arvillas service rig and the empty 300-barrel frac tank have been removed. Grass is starting to emerge on the former upper pit area. The former wellhead area has been rough graded. The property owner, John McCall, is satisfied with Arvillas reclamation on his property. I will not pass the Final Restoration until vegetation is established on the former upper pit area. |
191111569 | 2002-10-18 0:00 | SW | No Violations | |
1949270532 | 2010-09-29 | Final Restoration | No Violations | I met with Hal McSpadden (Select Energy) and Kyle Combest (environmental consultant) at the site. Kyle will be overseeing the Final Restoration at the site. Sunpro is cleaning out the upper pits today. The liners will be pulled out and taken to American Landfill in Waynesburg for disposal. |
1978693952 | 2007-09-26 | Salt Water Injection Well | No Violations | The injection pump was not running at the time of the inspection. There were no violations at the wellhead or at the brine pits. This facility is up for sale. |
2000912134 | 2013-07-12 | Final Restoration | No Violations | No indication of well equipment, or tank battery. Access road still in use for other producing wells and tank batteries. |
2045226942 | 2010-06-08 | Salt Water Injection Well | No Violations | The injection well has 110 psi on the injection tubing and is flowing back into a 500 bbl frac tank. The service rig crew is monitoring the flow back. |
2059684469 | 2004-01-06 | Salt Water Injection Well | No Violations | Repairing the 2 dia. flowline that was encased inside the 4 dia. flowline. Met with Bill Westphal of Belden & Blake. |
2146417780 | 2010-06-22 | Plug / Plug Back | No Violations | Formation Cementing pumped the combined Newburg and packer isolation plug thru tubing.. |
226102839 | 2004-9-21 0:00: | SW | No Violations | |
258997434 | 2008-12-18 0:00 | SW | No Violations | |
320714008 | 2007-3-13 0:00: | SW | No Violations | |
333630213 | 2008-3-21 0:00: | SW | No Violations | |
379426048 | 2008-9-25 0:00: | SW | No Violations | |
449625893 | 2010-6-23 0:00: | PB | No Violations | |
547911037 | 2010-8-17 0:00: | FR | No Violations | |
575910565 | 2010-6-10 0:00: | SW | No Violations | |
713579936 | 2007-11-21 0:00 | SW | No Violations | |
894362062 | 2009-4-1 0:00:0 | SW | No Violations | |
900444640 | 2010-1-4 0:00:0 | PB | No Violations | |
943833021 | 2009-11-6 0:00: | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1192046293 | US-OH-105073 | 2007-10-10 | Pollution/Contamination | |
1192046293 | US-OH-105074 | 2007-10-10 | Pits not liquid tight/Improper construction or use |